Home / Hollard / Determination 975018

Determination 975018

Claim denied for cracking said to be caused by excluded earth movement rather than earthquake

FirmHollard
Decided2023-12-20
ProductGeneral Insurance · Home building and contents
OutcomeFor the complainant in part
Amount awarded—
Non-financial loss—
Amount claimed—
SourceAFCA PDF

Summary

Complainants claimed for cracking to their home after an earthquake and the insurer denied it as excluded earth movement. AFCA found the western and rear cracking was covered, the eastern cracking was not, and ordered a scope of works and cash settlement with 10% uplift.

The insurer bore the onus of proving the earth movement exclusion and failed to show the earthquake was not the proximate cause of the more significant western and rear cracking.

Issues

Subjects and remedies

home or building damagenatural disasterpay claim

Related

All Hollard determinations · Find similar determinations

Text of the determination

Determination Case number 975018 Financial firm The Hollard Insurance Company Pty Ltd Determination | Case number: 975018 Page 1 of 7 Case number: 975018 12 December 2023 1 Determination overview 1.1 Complaint The complainants have claimed under their home insurance policy for damage they say was caused by an earthquake event on 21 September 2021. The financial firm (the insurer) has denied the claim as they say the damage was not caused by the earthquake and was instead caused by unrelated earth movement over time which is excluded under the policy. 1.2 Issues and key findings Is the insurer entitled to deny the claim? No, whilst the cracking on the eastern side of the home was likely caused by earth movement excluded under the policy, the more significant cracking to the western side and rear of the building was most likely caused by the earthquake. The insurer is liable to repair the damage consisting of cracking to the western side and rear corner of the property (detailed later in this determination as the covered cracking). Why is the outcome fair? The insurer has limited its policy cover so damage caused by earth movements other than earthquake are not covered. The insurer bears the proof of establishing the limitation is applicable. T he complainant‟s engineer has put convincing arguments as to why an earthquake event of the intensity involved did cause a significant portion, though not all, of the cracking to the home. They also effectively called in to question whether the insurer‟s engineer‟s alternative list of causes would have been sufficient to cause all of the damage. 1.3 Determination This determination is substantially in favour of the complainants. Within 14 days of notification of the complainant‟s acceptance of this determination the insurer must:  arrange for a builder/engineer to attend, assess and prepare a scope of works (SOW) required to repair the covered cracking;  on receipt of the SOW provide a copy to the complainant; and  then cash settle the claim based on the SOW and quote obtained including a 10% uplift for transfer of risk and contingencies. Determination | Case number: 975018 Page 2 of 7 2 Reasons for determination 2.1 Is the insurer entitled to deny the claim? No, whilst the cracking on the eastern side of the home was likely caused by earth movement excluded under the policy, the more significant cracking to the western side and rear of the building was most likely caused by the earthquake. The insurer is liable to repair the damage consisting of cracking to the western side and rear corner of the property (detailed later in this determination as the covered cracking). Policy covers accidental loss and damage and not otherwise excluded The initial onus is on the complainant to establish on the balance of probabilities (that is more likely than not) that the loss or damage falls within the terms of the policy. This is known as a valid (or prima facie) claim. Once the complainant has established a valid claim, the onus shifts onto the insurer to establish, on balance, the application of a policy exclusion or that it is otherwise entitled to deny the claim under the policy. Insurer must show the proximate cause of the damage is excluded The complainant‟s policy provides cover for accidental da mage. Both parties accept that there has been damage and that it has been accidental. I am satisfied that the complainants have established a valid claim under the policy. The onus therefore shifts to the insurer to show that it is entitled to deny the claim. The insurer refers to exclusions for:  Settling, shrinkage or any movement of earth; and  Rust, corrosion, gradual deterioration, depreciation, wear or tear. There is an exception to the exclusion regarding earth movement, where the damage occurred within 72 hours of, and as a result of, an earthquake. To deny the claim, the insurer must show that the proximate cause of the damage falls within the exclusion clause it is relying upon. The evidence from both sides is that the damage resulted from earth movement. To be successful the insurer needs to establish that the proximate cause of that movement was something other than the earthquake. This is a question of fact depending on the circumstances. The proximate cause is not necessarily the first, or last or sole cause of the loss. It is the effective, dominant or operative cause of the loss. The circumstances of the claim At the time of the claim the complainants‟ home was approximately 4 years old, the build having been completed sometime in 2017. It is of double story brick veneer construction, with basement walls of 300mm thick, filled block concrete blocks, and a first and second floor of timber frame construction with internal plasterboards and external brick veneer and a concrete slab floor. There is also an alfresco area with a double brick wall. All external walls are rendered. There was an earthquake event on 22 September 2021, the centre of which was located some 120 kilometres from the complainant‟s property and 10 kilometres below the s urface. It Determination | Case number: 975018 Page 3 of 7 measured 5.9 on the Richter Scale and the authorities estimated the impact in the area of complainant‟s property at IV on the Modified Mercalli Sc ale (MMI). That scale is used to rate the level of felt and measured impacts of an earthquake for a particular location. The complainants‟ lodged their claim on 26 November 2021. There is both external and internal cracking to the home building. In particular there are:  cracks at both ends of the west facing double brick alfresco wall which are 2-3mm wide at the rear boundary and 1mm wide at the other end;  cracks to the west facing brick veneer façade at ground floor level;  some render cracking on the eastern wall of the house: and  minor interior cracks. The expert evidence on causation Both parties relied on engineer‟s reports on the issue of causation and the engineers provided a number of follow up reports adding to their views or commenting on the views of the other party‟s engineer. Both also had builder‟s reports and it was the builders who were the first to attend the property. The insurer‟s engineer concluded that the cracking was not caused by the earthquake They relied on the MMI estimate of IV, which means light shaking which is not expected to cause structural damage to buildings. They also did a floor level survey that found variation in the slab floor level in the home of 32mm with a general pattern of relative settlement towards the internal central region of the house. They noted that the area has moderately reactive clay soils which could expand and contract with changes in moisture content. They considered the location and pattern of the cracking was consistent with damage caused by differential foundation movements due to reactive soils combined with long term deflection of the supporting structure, i.e. the central settlement of the slab. They also noted that there was evidence at the property of previous repairs of cracks which suggested cracking had occurred prior to the earthquake. This was also observed by the insurer‟s builder. They considered that the damage had been caused by a combination of:  Long term differential footing movements associated with variation in moisture content of the reactive clay soil;  Long term deflection of supporting structure (suspended slab and steel beams) within the central region of the house;  Absence of articulation joints within brick walls;  Long term brick growth; and  Long term movement of cementious rendering and underlying brickwork due to different thermal expansion rates. The complainant provided evidence from their builder that after the earthquake some patching of cracks had been done on a temporary basis on 23 November 2021 to prevent further separation. The complainant‟s engineer said that long term movement of footings should be ruled out as a cause as there had not been significant variation in soil moisture content in recent years and that failed footings would produce vertical cracks rising from the ground up which was not evident here. They considered that settling of the slab in the centre of the house would not produce major cracks in brick veneer walls because the bricks are supported by the basement walls and the footings and are not supported by the floor joists. They argued that if central sagging were to Determination | Case number: 975018 Page 4 of 7 blame there would be more cracks in the internal stud walls. In their view variat ion in floor heights of 10-30mm were possible as variation from the building process rather than subsequent movement. They provided evidence that contrary to the insurer‟s engineer‟s report, there were articulation joints in the walls. They considered brick growth would not be a significant force in the 4 years the building had been in place. In relation to differential expansion rates of cement render they were of the view that whilst it can cause cracks but not cracks of the size found on the west façade of the house. They state it is fairly common to get brick cracks in an earthquake of MMI IV. They also explained that the fact that the west façade sat on two different footings of different depth, the garage footing at the front and the shallower strip footing at the rear, it was more vulnerable to cracking. They considered that the footings reacted differently to the shockwaves from the earthquake and “like two ocean waves running into each other” this released forces upward causing the crack in the brick veneer area above where the strip footings meet with the basement wall. The complainant‟s engineer placed particular emphasis on this last point relating to differential footings as explaining how an earthquake of the size involved could cause the significant cracking at both ends of the western façade. Assessment of evidence on causation and conclusions I accept that the MMI rating of IV for an earthquake event would in the majority of cases mean that there is unlikely to be structural damage caused to buildings. However I also acknowledge that this can be impacted by many local factors. The i nsurer‟s engineer stated that these factors, such as local geology and the structure of the building, can lead to considerable variations in damage caused even within a single neighbourhood. The issue of whether there was any pre-existing cracking is contested. The complainant provided strong evidence that the builder who attended the property in November 2021 did some temporary repairs. Counter to this the insurer‟s builder and engineer both considered that some of that cracking and repairs looked older and that some of the repairs had opened up by the time of the builder‟s visit to the property in December 2021 and the engineers in February 2022. I accept that there was some pre-existing cracking. I accept the evidence that some of the cracking looked ol der. I don‟t consider it likely that cracks caused by an earthquake in September and patched in November would reopen so quickly. Nevertheless, I don‟t accept that the sources of movement identified by the insurer‟s engineer were sufficient to cause all of the cracking at the property and in particular the wider cracking on the western façade. All of the potential causes they identified were long term, yet the building was only 4 years old. Long term differential footing movements caused by variation in soil moisture content can generate movement and cause cracking. But a table provided by the insurer‟s engineer put those movements where the soil is moderately reactive as having a timeframe of greater than 20 years and less than 40 years. The engineer noted that that is for normal variations in moisture content and that it can be quicker where those variations are abnormal. The engineer provided a range of possible reasons for abnormal variation in soil moisture content, but only provided arguments for variation caused by the drying effects of tree roots in the vicinity. They stated that there were numerous trees and shrubs in close proximity to the building. This claim does not appear to be supported by the aerial and other photos of the property which show relatively modest tree cover, particularly in comparison to other houses in the area. Determination | Case number: 975018 Page 5 of 7 I prefer the evidence of the complainants‟ engineer that the impact of „long term brick growth‟ is unlikely to be significant in a 4 year old building. Similarly, I agree with them that „long term movement‟ in cementous render and brickwork would not be sufficient, in such a young building, to contribute significantly to the creation of such wide cracks as appear in the western façade. The floor survey done by the insu rer‟s engineer provided useful evidence. It found variation of 30mm with it being generally lower in the centre of the house. This might support the argument that the house was impacted by earth movement from non-earthquake sources. The complainant‟s engin eer considered 30mm of variation might be within normal range whilst the insurer pointed to building standards that it should be no more than 20mm. I am persuaded by the arguments of the complainant‟s engineer that the external walls the subject of cracking are supported by the footings. If earth movement generated sagging of the central part of the house had caused the major cracking in the western façade, there would also be cracking in the internal walls closer to the site of the sagging. There are no such cracks reported. Finally, in relation to the absence of articulation joints as a possible contributor to the damage, the two engineers now agree that there are articulation joints but that they have been rendered over. The insured‟s engineer states th at the rendering over of them can restrict their intended function and lead to cracking in the render. This appears true in the present case as there are render cracks reported at their locations in the structure. T he complainant‟s engineer has provided an explanation, being the differential footings under the two ends of the western side of the house, about how the earthquake forces involved could cause the significant cracking in the that façade. The insurer‟s engineer did not effectively respond to that explanation other than by asserting that if braced to standards a building should not be impacted by an earthquake event of the intensity involved. Whilst as noted I accept there was some pre-existing cracking from other causes, I consider it more likely that the more significant cracks have been caused by the earthquake and thus the insurer is liable for the repair of those cracks. Settlement of the cracking damage As the two parties have taken absolute positions, that either all the damage was caused by the earthquake or none was, there is a lack of evidence addressing each of the cracks separately. This creates challenges when seeking to delineate which cracks are more likely generated by the earthquake and which by excluded sources of earth movement. In undertaking that task I have remained conscious that the burden of proof is on the insurer to establish the exclusion The complainant‟s case is convincing as regards the western façade of the house and the alfresco wall. This extends to damage associated with separation of the range hood in the alfresco, the vertical cracking to the wall at the southwest corner (Photographs 5 and 6 in the insurer‟s engineer‟s report dated 3 March 20 22) and the cracking to the southern side of the basement (photograph 15, 16, 17 and 18 of that same report). I am satisfied that the insurer is liable for the repairing of all of that cracking (the covered cracking). No information is available on the cost of those repairs. It is fair in the circumstances that within 14 days of notification of the complainant‟s acceptance of this determination the insurer: Determination | Case number: 975018 Page 6 of 7  arrange for a builder/engineer to attend, assess and prepare a scope of works (SOW) required to repair the covered cracking;  on receipt of the SOW provide a copy to the complainant; and  the insurer can then cash settle the claim based on the SOW and quote obtained including a 10% uplift for transfer of risk and contingencies. I consider the cracking on the eastern side of the house, which is more hairline cracking to the render and does show signs of prior repairs to be more consistent with the longer term causes identified by the insurer‟s engineer, noting also that no argumen t was made about differential footings on that eastern side. I am satisfied the insurer is not liable for this damage. 2.2 Why is the outcome fair? The insurer has limited its policy cover so damage caused by earth movements other than earthquake are not covered. It has effectively communicated that limitation in the policy documents provided to the complainant. Both parties have had the opportunity to put their case and the views of their experts and to consider and respond to the arguments and evidence, including expert evidence, put by the other. The insurer‟s engineer‟s case principally relies in the relatively low MMI rating of the event‟s impact in the area of the property and puts forward other potential causes of cracking all of which are long term but which if applicable would exclude the damage from cover. The complainant‟s engineer has put convincing arguments as to why an earthquake event of the intensity involved could cause a significant portion, though not all, of the cracking to the home. They also effectively called in to question whether the insurer‟s engineer‟s alternative list of causes would have been sufficient to cause all of the damage in the circumstances involved including the relatively low age of the house. On balance the insurer has not satisfied the burden of proof on it to prove the application of the exclusion to the covered cracking. Determination | Case number: 975018 Page 7 of 7 3 Supporting information 3.1 The AFCA process AFCA’s approach is based on fairness AFCA has determined this complaint based on what is fair in all the circumstances, having regard to:  the legal principles  applicable industry codes or guidance  good industry practice  previous decisions of AFCA or its predecessor schemes (which are not binding). The respective parties have completed a full exchange of the relevant information, and each party has had the opportunity to address any issues raised. We have reviewed and considered all of the information the parties have provided. While the parties have raised a number of issues in their submissions, we have restricted this determination to the issues that are relevant to the outcome. We assess complaints on available information and circumstances AFCA is not a court of law. We do not have the power to take or test evidence on oath, or to require third parties to give evidence. When we assess complaints, we consider:  available documents  the recollections of the parties  all relevant circumstances. We give more weight to documents created at the time the events occurred. If there are no relevant documents, we will decide what most likely occurred based on the available information. If there are conflicting recollections and these are evenly weighted, we may find that a claim cannot be established.

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.