Home / Suncorp Group / Determination 930925

Determination 930925

Insurer declined the claim for underpinning a brick pier destabilised by storm, saying there was no damage and an exclusion applied

FirmSuncorp Group
Decided2023-08-31
ProductGeneral Insurance · Home building and contents
OutcomeFor the complainant
Amount awarded$20,735
Non-financial loss$3,500
Amount claimed$20,735
SourceAFCA PDF

Summary

A storm destabilised a brick pier at the complainant's home and the insurer declined the underpinning cost. AFCA found the claim covered, ordered payment of $20,735 plus interest and $3,500 non-financial loss, and reimbursement of expert report costs.

Destabilisation of the pier is damage caused by a storm, and the insurer did not prove any exclusion applied.

Issues

Subjects and remedies

home or building damagenatural disasterpay claimpay compensationpay interestpay non financial loss

Related

All Suncorp Group determinations · Find similar determinations

Text of the determination

Determination Case number 930925 Financial firm AAI Limited Determination | Case number: 930925 Page 1 of 21 Case number: 930925 17 August 2023 1 Determination overview 1.1 Complaint The complainant held a home and contents insurance policy with the financial firm (insurer). The complainant’s property was damaged in a storm on 7 and 8 March 2022. She lodged a claim with the insurer who partially accepted the claim. The only issue remaining in dispute between the parties is whether the insurer is liable to pay for the cost of reinstating a brick pier which the complainant says was damaged as a result of the storm. The insurer has declined this aspect of the claim because it says there is no evidence that the brick pier was damaged by the storm. Further, if the brick pier has been destabilised, it was as a result of a soil batter being washed away which is excluded under the policy. The complainant disagrees with the insurer’s decision and seeks that her claim be accepted. 1.2 Issues and key findings Can the insurer decline the claim? No. From that available evidence I accept that the destabilisation to the brick pier is damage that was caused by a storm. The insurer has not proven any exclusion applies to decline the claim. Is the complainant entitled to compensation? Yes. The insurer mismanaged the claim and caused the complainant unnecessary stress and inconvenience. The insurer should pay $3,500 in non-financial loss compensation. Why is the outcome fair? The outcome is fair because the policy covers loss or damage caused by a storm. I do not accept the insurer’s argument that destabilisation of a brick pier does not amount to damage covered under the terms and conditions of the policy. No exclusions apply to decline the claim. On that basis, it is only fair the insurer pay the claim plus interest. 1.3 Determination This determination is in favour of the complainant. Within 14 days of the complainant accepting this determination, the insurer is to pay the complainant:  $20,735 for building repairs plus interest in accordance with section 57 of the Insurance Contracts Act (1984) from the date the complainant paid the invoice until the date the insurer reimburses the complainant  $3,500 for non-financial loss compensation. Determination | Case number: 930925 Page 2 of 21 The insurer is also to reimburse the complainant the cost of any expert reports obtained by her that have not previously been reimbursed, within 14 days of being provided with proof that these invoices have been paid by the complainant. Determination | Case number: 930925 Page 3 of 21 2 Reasons for determination 2.1 Can the insurer decline the claim? No. From that available evidence I accept that the destabilisation to the brick pier is damage that was caused by a storm. The insurer has not proven any exclusion applies to decline the claim. Complainant must establish a valid claim It is established insurance law that the complainant carries the initial onus to show on the balance of probabilities that she has suffered a loss caused by a risk insured under the policy. The policy is an insured events policy which covers listed insured events, including loss or damage caused by a storm. If the complainant establishes a valid claim, the onus shifts to the insurer to establish an exclusion applies. The standard of proof is the balance of probabilities. See section 3.2 below for relevant definitions and extracts from the policy. Circumstances of the claim The complainant owns a property which is built on a slope. On 8 March 2022, there was a storm in the Sydney area. It is not in dispute that given the amount of rain during the storm, the complainant suffered damage to her property. This included damage to a soil batter, internal damage to the rumpus room and entrance area and contents damage. The complainant says, but the insurer disputes, that there is also damage to the brick piers underneath the house. The insurer conducted a make safe immediately following the storm. This involved constructing timber bracing underneath the house to stabilise the pier. It was not intended that this would be a long-term solution. Since that time, there has been a protracted dispute between the parties about what damage is covered. The complainant engaged AG (geotechnical engineer) to inspect the property on 14 March 2022. AG said that the soil batter under the house had washed away because of the volume of water that washed down it during the storm event on 8 March 2022. AG recommended a structural engineer be engaged to determine the best way to repair the unstable brick pier. Following this, the insurer’s assessor reviewed AG’s report and engaged it s own engineer, MCS, to attend and determine the cause and extent of damage. MCS attended the property and provided a report dated 26 April 2022. MCS noted a range of damage and said in his opinion, the soil batter was too steep and coupled with the significant rainfall this caused the damage. He also noted that the make safe works that had been conducted were only a temporary measure and recommended that a geotechnical engineer urgently be appointed. MCS advised the complainant not to live at the property because of his concerns that it was unsafe. After receiving MCS’ report, the insurer’s assessor formed the view that the brick pier was not damaged and on that basis it was the complainant’s responsibility to reinstate the soil batter Determination | Case number: 930925 Page 4 of 21 to stabilise the brick pier. The insurer made no arrangements for a geotechnical engineer to be appointed as recommended by its own expert. The complainant then engaged a structural engineer (NBCE) who prepared a report dated 5 August 2022. He said that the brick pier appeared partially undermined and recommended a geotechnical engineer attend to provide advice about the best way to repair the property. The complainant then engaged SR, a geotechnical engineer, who prepared a report dated 28 October 2022. This report attached a scope of works to repair damage to the undermined brick pier and also to the soil batter. See section 3.3 below for excerpts of the relevant expert and assessor reports. The complainant then obtained a quote to carry out the underpinning work, which she says is what is required to repair the damage to the brick pier. She has not sought any costs associated with reinstating the soil batter because she acknowledges this is not covered under the terms and conditions of the policy. Insurer says piers have not been damaged There is no dispute the complainant has made a valid claim under the policy because her property has been damaged by storm. The insurer also does not dispute that the washing away of the soil batter (from the severe storm event) had led to the destabilisation of the brick pier. The policy covers the complainant for loss or damage to her building caused by an insured event, in this case a storm. The insurer does not dispute that the brick pier forms part of the building. The crux of the insurer’s argument is that just because the brick pie r has been destabilised does not mean that it has been damaged. The insurer relies on the expert reports which it says confirms this. The insurer also says that even if the brick pier began exhibiting damage this would be excluded because the damage was not directly caused by a storm but caused by a lack of stabilisation, which is not an insured event under the policy. Insurer cannot decline the claim I have reviewed the expert reports and policy in its entirety. The policy covers loss or damage caused by a storm. Damage is not defined in the policy. The Oxford dictionary definition of damage is physical harm caused to something that makes it less attractive, useful, or valuable Further, damage has been typically understood to occur in insurance when the item’s value or usefulness has been impaired. It is not in dispute from reviewing all the expert reports that the pier has been destabilised because of the storm. In my view, destabilisation of the brick pier is equivalent to it being damaged. This is because the pier is less useful because of the damage caused to it during the storm. Determination | Case number: 930925 Page 5 of 21 The complainant’s experts say that the brick p ier and side wall have been destabilised because of the volume of water that flowed across the soil batter which resulted in a landslide. At no point has the complainant sought the cost of having the soil batter reinstated. The complainant’s argument is th at the storm caused the brick pier to be destabilised and therefore damaged, because of the landslide/subsidence of the soil batter. The policy covers storm damage. This includes damage caused to a building where damage has been caused by a landslide or subsidence proved to have occurred within 72 hours of, and directly because of, a storm, unless it occurred because of erosion or a structural or design fault. The insurer’s assessor makes reference to the soil batter being too steep, which he says i s a design fault. He provides no reasoning to support this assertion or references to any codes applicable at the time of construction or renovation. The batter had been in place for 26 years prior to the storm event. There is no dispute the damage to the property occurred within 72 hours of the storm. There is also no dispute that the brick pier had been destabilised directly as a result of the storm. This is because the volume of water that ran down the soil batter washed the soil away. For the reasons outlined above, I consider that destabilisation amounts to damage. The complainant has paid for the cost of underpinning the brick pier and side wall to ensure its stability. The insurer has not proven any exclusion applies to decline the claim. On that basis, the insurer is liable for the cost of the underpinning works in the amount of $20,735 plus interest. 2.2 Is the complainant entitled to compensation? Yes. The insurer mismanaged the claim and caused the complainant unnecessary stress and inconvenience. The insurer should pay $3,500 in non-financial loss compensation. AFCA may award non-financial loss compensation in certain circumstances Under paragraph D.3 of the AFCA Rules, AFCA may award compensation for non-financial loss (capped at $5,400) where the insurer’s actions have caused an unusual amount of physical inconvenience, time taken to resolve the situation or interference with the complainant’s expectation of enjoyment or peace of mind. File indicates insurer mismanaged claim I have reviewed the entire file, including the contact notes from the insurer. The complainant made a claim for contents, internal damage and for damage to the building following the storm event. The insurer initially conducted make safe works and appointed an engineer, but then took no action in appointing further experts after that time. In my view, the insurer’s assessment of its own expert report was incorrect. MCS indicated that there were issues with the brick pier, that the property was potentially unstable and recommended that the complainant not live at the property. He also recommended an urgent geotechnical investigation take place. The insurer did not arrange a geotechnical report, but rather left this to the complainant. In addition to the dispute about the brick pier, the insurer continued to decline the complainant’s contents claim and her claim for internal damage. The insurer also refused to pay for temporary accommodation despite its own expert advising the complainant not to live at the property. Determination | Case number: 930925 Page 6 of 21 The reasons behind not accepting the contents claim and internal damage were that the insurer said the complainant had not completed works at the property following a claim in 2020. This was also incorrect. The complainant completed the recommended works in February 2022, before the storm event. The insurer also attempted to decline the claim on the basis that loose and compacted soil was not covered as part of the building under the policy. However, at no point did the complainant request that the insurer cover the cost of reinstating the soil batter. The complainant says , and I accept, that the insurer’s conduct has caused her significant stress and inconvenience. She said that she was forced to live in a property which the insurer’s expert said was unsafe, was denied temporary accommodation for her and her family and had to pay to repair damage to her property which should have been covered by the policy. Insurer should pay $3,500 compensation The insurer has maintained its position until this complaint was lodged at AFCA. It was only shortly prior to this determination being issued that the insurer accepted the complainant’s claim for contents and internal damage, despite having no reason to decline this aspect of the claim. Having reviewed the available evidence, I accept the complainant’s submissions. I also note from my review of the file that the insurer did not adequately assess the complainant’s claim under the terms of the policy and provide satisfactory reasons or evidence to support its assertions. I acknowledge that this would have caused undue stress and inconvenience to the complainant. On that basis, the insurer is to pay $3,500 in non-financial loss compensation. 2.3 Why is the outcome fair? The outcome is fair because the policy covers loss or damage caused by a storm. I do not accept the insurer’s argument that destabilisation of a brick pier does not amount to damage covered under the terms and conditions of the policy. No exclusions apply to decline the claim. On that basis, it is only fair the insurer pay the claim plus interest. Determination | Case number: 930925 Page 7 of 21 3 Supporting information 3.1 The AFCA process AFCA’s approach is based on fairness AFCA has determined this complaint based on what is fair in all the circumstances, having regard to:  the legal principles  applicable industry codes or guidance  good industry practice  previous decisions of AFCA or its predecessor schemes (which are not binding). The respective parties have completed a full exchange of the relevant information, and each party has had the opportunity to address any issues raised. We have reviewed and considered all of the information the parties have provided. While the parties have raised a number of issues in their submissions, we have restricted this determination to the issues that are relevant to the outcome. We assess complaints on available information and circumstances AFCA is not a court of law. We do not have the power to take or test evidence on oath, or to require third parties to give evidence. When we assess complaints, we consider:  available documents  the recollections of the parties  all relevant circumstances. We give more weight to documents created at the time the events occurred. If there are no relevant documents, we will decide what most likely occurred based on the available information. If there are conflicting recollections and these are evenly weighted, we may find that a claim cannot be established. Determination | Case number: 930925 Page 8 of 21 3.2 Relevant terms of the policy Page 18: What we cover as the building We cover The building that you own or are responsible for and use primarily for domestic purposes and described as ‘The building’ on your certificate of insurance (if it shows a description of ‘The building’) including the following at the insured address: Page 19: What we don’t cover as th e building We don’t cover Building does not include: …  loose or compacted soil, sand, lawn, grass, artificial grass, gravel (including on roads, driveways and tracks), pebbles, rocks or granular rubber; Page 20: We don’t cover things that happen because t he building is not in good condition or because any building extensions, alterations or renovations are not complete. We do not cover any part of the building that is not in good condition or that has wear, tear or deterioration and we do not cover some losses where building extensions, alterations or renovations are not complete. Pages 25 to 31: We do not cover: Defects, faults, workmanship • loss or damage caused by, connected with or arising from, or liability caused by, connected with or arising from inherent defects, faulty design, structural defects, structural fault or faulty/poor workmanship (e.g. structural posts, beams or load bearing walls have been removed without taking into account structural engineering requirements), if you knew or should have reasonably Determination | Case number: 930925 Page 9 of 21 known about it (e.g. because the defect or fault was able to be observed by you or because it was identified in a pre-purchase building inspection report); • any loss or damage to the part of the building with an inherent defect, faulty design, structural defect or faulty/poor workmanship, whether or not you knew or should reasonably have known about it. For details about ‘How we deal with defects, faults and poor workmanship’ as part of the repair or rebuilding process see page 83. Page 38: What you are covered for- Insured Events Loss or damage to the building We cover We cover loss or damage to your building at the insured address caused by an insured event in the period of insurance. The insured events we cover are set out on pages 39 to 52. Page 41: Storm We Cover Loss or damage caused by a storm. We don’t cover • loss or damage caused by flood; • loss or damage caused by erosion, vibration, subsidence, landslip, landslide, mudslide, collapse, shrinkage or any other earth movement, but we will cover loss or damage to the building caused by a landslide or subsidence proved to have occurred within 72 hours of, and directly because of, a storm and not because of erosion, structural fault or design fault; • loss or damage to retaining walls, sea walls, revetments, garden borders and free standing outdoor walls; Determination | Case number: 930925 Page 10 of 21 3.3 Relevant expert reports Record Key points Complainant’s expert (AG ) Geotechnical Engineer Report 21 March 2022  Conducted a site inspection on 14 March 2022 We understand that during the recent prolonged and intense rain fall, surface run - off had been entering the subfloor area and had resulted in washout of a soil batter immediately behind the brick wall at the rear of the lower level of the residence (Image 1). This washout has eroded th e batter adjacent to a brick pier and has undermined a portion of the brick wall along the western side of the dwelling (Image 2).  At the time of inspection a temporary timber brace had been constructed but this is not permanent and will not prevent further damage.  Severe rainfall event between 22 February 2022 and 9 March 2022. This led to a peak saturation of upslope soil and the inability of soil to absorb the subsequent rainfall. As a result a large volume of slope wash travelled down the slope.  Subsidence has been caused by groundwater on the exposed and unsupported soil batter. Slope wash entering from the sides of the house may have contributed to the batter failure.  Recommends a structural engineer provide details on deleting the unstable pier or alternatively the pier could be demolished and reconstructed but this may also require underpinning works.  Recommends the soil batter should be covered in fabric and met al mesh to provide long term stability and a drain should be constructed at the bas e of the brick wall. Insurer asse ssor report 29 March 2022  Attended property after event and receiving report of AG.  Confirmed complainant is not seeking damage to pool room be paid as this was already cash settled under previous claim. Complainant undert ook external repairs (drainage) but had not completed internal repairs as yet. I have advised [complainant] that I will request another make safe on the area based of the engineers report. After the review of the damage I have advised [complainant] that I will need to appoint and engineer to determine the extent of damage. I have advised that if there is no damage to the pier Determination | Case number: 930925 Page 11 of 21 Record Key points then we would not replace it. I have advised that as per the PDS, there is no coverage for compacted soil and [insurer] will not repack the soil. I have advised that the engineer will determine the cause of the damage and if the water has seeped through the bedrock causing the soil to collapse. I have advised that the only building item I can see affected by the event is the ne wly installed p ump. [Complainant] understood. I have advised that once the engineers report is submitted we can review the claim further. Things to consider when making a claims decision; - If there is no damage to the pier is there a repair we could co mplete to mitigate any future loss. Insurer’s expert (MCS) Engineer 26 April 2022 Executive summary 2.1 MCS notes that in past alterations and additions the rear of the lower - level rooms has been moved to the north. That is the existing original batter slope behind the original wall was excavated. 2.2 Referring to the new rear wall, the drawings state r etaining wall if required by engineer. 2.3 We note no retaining wall was provided but rather the batter was made steeper. 2.4 MCS is of the opinion that the batter was too steep with the result that the batter face has fretted and destabilised. The significant rain event has contributed to the destabilisation. 2.5 Whilst temporary make safe works have been carried out in a w orkman like manner and to a high standard, they have not actually stabilised the Determination | Case number: 930925 Page 12 of 21 Record Key points founding material under the brick pier near the crest of the embankment. At the time of the inspection MCS did not detect any movement of the brick pier. 2.6 MCS is of the op inion that the pump would have been damaged. 2.7 MCS advised the Insured she should not live in the property. The Insured advised that she had already organized to stay with her partner.  Attended a site inspection with the insured. Access underneat h the house where it noted timber bracing had been applied to support the existing brick pier at the top of the batter. However, whilst the bracing stabilises the brick pier it does not stop the material under the footing of the pier from collapsing.  Notes that the bottom rooms have been extended and that an original rear wal l was demolished with a new slab and new rear wall constructed. The drawings he was provided with state that the rear wall may need a ret aining wall subject to engineer’s advice. There is no retaining wall present, but the batter steepened. Subject to further geotechnical advice, MCS is of the opinion that the batter is now too steep resulting in potential pockets of instability. We note that only limited engineering drawings are available.  He reviewed the Geotec hnical letter provided by the complainant. It is not detailed enough. On that basis, MCS recommends that a detailed geotechnical site investigation is required.  Mak e safe works have been carried out to a high standard but they do not actually support the existing potentially unstable batter. Subject to geotechnical advice it may be possible to temporarily support the beam that the pier supports but this would require investigative works. Proximate cause 8.1 Subject to geotechnical adv ice and investigation MCS is of the opinion that the adjusted batter slope behind the rear wall was Determination | Case number: 930925 Page 13 of 21 Record Key points unstable due to the batter slope being too steep 8.2 MCS also notes that the extreme rain event has added to the instability of the slope.  Recommended that as a matter of urgency a detailed geotechnical investigation be carried out then remedial works. They also advised the complainant to vacate the house. Insurer asse ssor report 7 June 2022 After receiving MCS report. After reviewing the above informa tion and documents, I have determined that the washe d away soild that may make the brick pier unstable, is not able to be covered due to the policy exclusion. The engineer has determined that there is no damage to the brick pier. The engineer believes that the pump installed for drainage would have been damaged due to the collapse of the soil slope under the house. As there is no damage to the brick pier, and the exclusion of soil, it is the customer’s responsibi lity to urgently r einstate the soil slope to stabilize the brick pier. Complainant’s expert NB CE (Engineers) R eport 5 August 2022  Property is a three storey house wit h concrete footings and brick piers supporting timber floor joists and load bearing masonry and stud walls Observations: Significant erosion of the existing batter in the subfloor. Significant build - up of water at the base of the batter behind the ground floor brick wall. The isolated brick pier footing appears to be Determination | Case number: 930925 Page 14 of 21 Record Key points partially undermined. The soil below the bri ck pier footing appears unsupported. The soil below the eastern and western walls supporting the brick wall appear to be u ndermined. The isolated bric k pier currently braced appears to be supporting floor joists only. The double storey stud wall adjacent to the stairs appear to be supported by a timber double joist. No cracking or damage was identified to the isolated brick pier. Our visual inspection could not identify any movement or cracking to the internal walls and finishes.  The undermining of the sup porting below the isolated pier is consistent with failure of the soil batter. Generally, soil batters require a minimum scope of 1:1 to be self - supporting. This slope appears to be steeper than 1:1 and therefore is unlikely to be self - supporting. Heavy ra infall can cause additional hydrostatic loads to the soil that can exacerbate batter failures. Evident at the property because of the partially expos ed footing below the brick pier. There is no visual indication that suggests cracking or failure to the bri ck pier, the proximity of the pier to the top of the existing batter does raise concerns. If the existing batter is not rectified, the supporting mater ial below the concrete footing may be further undermined as a result of future rainfall events. Based on our visual inspection the following repair options should be considered: E1. Detailed Geotechnical investigation to be undertaken to ascertain the stability of the existing batter. The geotechnical engineer should provide Determination | Case number: 930925 Page 15 of 21 Record Key points advice relating to the following items: • Probable cause of the batter failure and stabilisation measures that should be considered as part of the rectification measure. • Confirm if the site is in a landslip zone, and if the existing footings should be piers down to rock • Confirm the exist ing bearing capacity of the soil • Confirm the minimum edge distance the piers should be from the edge of the top of the batter E2. Subject to the advice provided by the Geotechnical Engineer the following options may be considered: Option 1 Stabilise the existing batter by installing shotcrete and mesh with soil anchors. Option 2 Re - frame the subfloor timber framing to remove all loads from all brick piers that are close to the zone of influence of the top of the batter. As a result of re - distributing the floor loads, the brick piers may be demolished. Option 3 Underpin all exist ing piers and walls down to a suitable bearing material. E3. In addition to the items outlined in section E2 above, we would also recommend constructing a new retaining wall in front of the existing engaged brick wall. A drainage cavity should be installe d between the new reinforced block wall and the Determination | Case number: 930925 Page 16 of 21 Record Key points existing brick wall. Complainant’s expert (SR ) Geotechnical Engineer Report 28 October 2022  Conducted site inspections of 4 July and 1 August 2022. Has also been provided with previous reports from other ex perts.  Hous e was built about 50 years ago. In 1995 renovations were undertaken to move the existing back brick wall dividing the existing garage to the underfloor of the house where the soil batter is now located.  After a claim in 2020, the insurer recomme nded the installation of a stormwater drain pipeline system and sump and pump to capture and get rid of stormwater from the backyard. These works were carried out on 9 February 2022.  Prior to the storm on 8 March 2022, the batter was in a good condition an d had been intact for 26 years.  Summarises previous reports obtained by parties .  Believes there are potential stability issues with the existing piers/footings. Location of property is in an area of the local council with the highest likelihood of instability. Slope is over 25 degrees inclination. Could not see any evidence of ground movement at the site.  The cau se of the damage to the piers was the landslide after the severe weather event. The ground is comprised of soil above weat hered rock materials.  The batter was damaged by the severe storm on 8 March 2022. Any further storms will continue to increase the ins tability if the batter and pier/footings are not remediated immediately.  Recommends the house not be occupied until remediation works are carried out.  Recommendation for remediation: 1. Construct new conc rete pillars/footings into the rock at the toe of the e xisting batter close to the existing brick wall. Ensure piers are constructed one at a time and no more than 600mm wide. Aft er this has been completed, the existing batter must be reprofiles for a permanent phase. Requ i res structural engineer. 2. Construct a concrete retaining wall at the front of the existing brick wall within the existing room and garage and backfill the void between the better and the brick wall under the subfloor to the same level of the existing piers. Requires stormwat er engineer to ensu re appropriate stormwater drainage behind retaining wall. Insurer Asse ssment report 22 November 2022  Desktop review of SR report I have since reviewed this report in length and can advise that the report has advised that the soil batter was incorrectly cut back in 1995 during Determination | Case number: 930925 Page 17 of 21 Record Key points renovations and that the brick pier has not been damaged directly by the event, however the foundation on which the brick pier is supported has failed. This has compromised the pier in the professional opinion of the attending Engin eer from SR. The following points were extracted from all reports on file which were considered during this review: - The report concludes that the exfiltration and hydrostatic load of the groundwater on the exposed and unsupported soils batter that has re sulted in the subsidence. Slope wash entering from the sides of the residence may have contributed to the batter failure. - Based on the visual inspection, the batter appears to be steeper than 1:1, therefore is unlikely to be self - supporting. Generally, s oil batters that consist of clay requires a minimum slope of 1:1 to be self supporting. - There is no visual indication that suggests cracking or failure to the brick pier, the proximity of the pier to the top of the existing batter does raise concerns. - No cracking or damage was identified to the isolated brick pier, - The undermining of the supporting below the isolated pier is consistent with failure of the soil batter, - It was confirmed and observed that the current foundations slope material is soi l/fill underlying by highly weathered weak rock materials, which cannot be rely on to permanently support the existing foundations - The soil/weak rock batter requires a minimum slope inclination of 1(V):2.5(H) to be self - supported permanently, based on our observations the batter appears to be steeper than 1(V):1(H), therefore the batter it is unlikely to be self - support.  Policy does not cover soil erosion and would recommend decline of brick pier. Although report indicates that the foundation mat erial Determination | Case number: 930925 Page 18 of 21 Record Key points on which the pier is located may have been compromised and exacerbated the batter’s failure, this appears to be as a result of defective workmanship when renovations were carried out in 1995. Because there is no damage to the brick pier, the policy does n ot respond. Insurer’s quote JLG 22 November 2022 SOW and quote to repair internal damage to downstairs area. $11,050.16 which includes a 16% builder’s margin. Complainant’s expert (C) Geotechnical engineer report 30 January 2023 It appears likely that the landsliding occurred due to saturation of the over - steep excavation within the sub - floor cavity. Whilst the previously formed batters were stable in a dry condition, they were formed over steep for long term stability when consid eration for seepage, breakage in piping or inflow from external sources is considered. Whilst groundwater seepage at the rock surface will have reduced the stability of the slope it appears very likely that surface stormwater flow during intense rainfall c ould have been directed into the sub - floor cavity on the western side of the house, which would have eroded and saturated the slope resulting in the sliding. This was a common mechanism of landsliding seen within the local area in March 2022. The external side walls of the sub - floor cavity are open with ground surface levels dropping down from the backyard along the side walls of the house, especially the western side, where the adjacent pool would concentrate surface flow towards this side of the house. As such, it is recommended that the sub - floor area be partially sealed/surface stormwater flow prevented from entry to this area as part of remediation works. The side walls of the house, where undermined, will need to be underpinned to bedrock to prevent a ny further slumping and potential settlement of the shallow founded brick footings. It is recommended that the underpinning extend to the low to medium strength bedrock surface Determination | Case number: 930925 Page 19 of 21 Record Key points (approximately 1.0m below the footing) as this material will not suffer any set tlement under the loading and will remain stable for the remnant design life of the house. This low to medium strength bedrock, where exposed across the base of the excavation, is stable and can be left exposed in a vertical cut whilst also being utilized as a foundation for any stabilising of the slope above. The continuity of this rock unit to the west will need to be confirmed by geotechnical inspection once the slide debris on the western side is removed, to ensure suitability of the stabilizing measur es. For design of slope stabilising measures this unit can be designed for 800kPa vertical bearing pressures even off the crest of the existing vertical excavation and where used for grouted rock bolts a grout/rock adhesion of around 200kPa is suitable in pull - out. The overlying extremely weathered sandstone and residual soils should be battered at 1.0V:1.5H for long term stability. Where a shotcrete support system is to be implemented then these units can be excavated at 70 – 80° in the temporary form pr ior to placement of the support system. The earth pressures on this shotcrete cover at a 75° batter would be based on ɤ ’ = 20kN/m³, Ka = 0.32. Geofabric wrapped strip drains must be laid down the soil batter before placement of steel or shotcrete at 1.50 m lateral separations. The strip drains must discharge to a stable/non erodible strip drain at the base of the slope, preferable with invert at/below the lower floor level slab crest, which is plumbed to the existing stormwater system (or a new system cons tructed). Where lateral support to the shotcrete is required then anchoring/dowels into the residual soils/weathered rock can be used. Where placed into soil, dowels should be galvanized for longevity Determination | Case number: 930925 Page 20 of 21 Record Key points and will need to gain stability only beyond a 45° infl uence line drawn up from the low to medium strength bedrock surface. A grout/soil adhesion of 100kPa is recommended in design. Complainant’s quote NB 31 January 2023 Methodology: i) Prop the subfloor framing as required to make safe ii) Underpin the external walls with mass concrete underpins down to base of excavation. Please refer to sketch Detail A below. iii) Remove timber braces currently bracing the brick pier iv) Scabble back existing batter to 1.0V:1.5H to remove all loose debris and rock. v) Geotechnical Engineer to Inspect the condition of the e xisting rock face to confirm if rock anchors will be required. vi) Install shotcrete wall in accordance with sketch Detail A with geofabric wrapped strip drainage down the soil batter adequate drainage to stabilise the existing slope vii) Demolish the undermined brick pier and construct a new mass concr ete footing to support a new post viii) Install a new galvanised post or uni pier to supplement the prick pier and support the floor bearer. ix) Inspect condition of existing drainage at the base of the w all and connect to the existing Determination | Case number: 930925 Page 21 of 21 Record Key points system. Complainant’s quote AU 22 February 2023 Sub floor Underpinning works as per engineer detail and directions including all material and labour completed 21 February 2 023. $20,735.00

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.