Home / Hollard / Determination 914775

Determination 914775

Insurer declined liability for ongoing water ingress to ground floor after storm repairs, which the complainant attributed to the insurer's repairers' nib wall

FirmHollard
Decided2023-10-16
ProductGeneral Insurance · Home building and contents
OutcomeFor the firm
Amount awarded—
Non-financial loss—
Amount claimed$52,120
SourceAFCA PDF

Summary

The complainant said the insurer's repairers' nib wall caused continuing water entry to his ground floor and sought rectification. AFCA found in favour of the insurer because the cause was the dwelling's design and inadequate drainage installed by the complainant.

The complainant did not show the insurer's repairs caused the water ingress, and the proximate cause was faulty design and defects, which the policy excludes.

Issues

Subjects and remedies

home or building damagenatural disasterno remedy

Related

All Hollard determinations · Find similar determinations

Text of the determination

Determination Case number 914775 Financial firm Hollard Insurance Partners Limited Determination | Case number: 914775 Page 2 of 11 Case number: 914775 16 October 2023 1 Determination overview 1.1 Complaint The complainant made a claim under a home and contents policy with the financial firm (the insurer) for damage to his home after a storm on or about 23 June 2020. The insurer accepted the claim. There was separate damage to the upper and lower levels of the property. Relevant to this complaint, water entered the ground floor damaging carpet, underlay, and furniture. While the insurer completed internal repairs, it required the complainant to complete exterior maintenance. This was to address defects identified in the construction of the complainant’s home and prevent further water entry. The complainant has lodged four complaints with AFCA since the original storm. The first and third complaints related to water tanks and upstairs repairs. Those complaints have been resolved. The second complaint related to water ingress to the ground floor. The insurer settled the complaint when it paid the complainant $10,000. The complainant says water continues to enter the property. He says repairs completed by the insurer’s repairers are the cause of this water entry (this complaint, the fourth complaint). The complainant says this is wrong and wants the insurer to accept liability and fix the cause of water ingress. 1.2 Issues and key findings Is the insurer’s assessment of its liability fair? The insurer is entitled to decline liability for damage to the insured property. It has established the repairs undertaken by its repairers are not the cause. Should the insurer remove the nib wall? No. The available information shows the waterproofing installed by the insurer ’s repairers is not causing the ongoing water ingress. Is the complainant entitled to compensation? The $10,000 paid by the insurer to settle the second complaint was fair and more than AFCA would award in the circumstances. Why is the outcome fair? I sympathise with the complainant. I accept it is upsetting for the complainant to have continued water entry into his home. However, the outcome is fair because the damage was not caused by the insurer’s repairer or any insured event under the policy. It would be unfair to require the insurer to rectify or pay for damage it did not cause or is not liable for. Determination | Case number: 914775 Page 3 of 11 1.3 Determination This determination is in favour of the insurer. The insurer is not required to take any further action. Determination | Case number: 914775 Page 4 of 11 2 Reasons for determination 2.1 Is the insurer’s assessment of its liability fair? Onus is on complainant to establish a valid claim It is established insurance law the complainant has the initial onus to establish a valid claim. The complainant must show it is more likely than not the loss or damage falls within the terms of the policy. If a valid claim is established, the onus shifts to the insurer to show, on balance, it is entitled to limit its liability in line with the policy wording or otherwise. The c omplainant says insurer’s repair work caused the damage The complainant needs to show a causal link between the insurance repair work and the damage. The complainant says water has re-entered his home because a nib wall (a waterproofed brick plinth) failed to prevent it. The insurer says the water ingress is due to property defects unrelated to the nib wall. It also says the complainant did not adequately complete external maintenance works to address defects he had been notified about before the recent damage. The insurer’s expert evidence is compelling There is no dispute water ingress occurs during rainfall. The insurer’s liability will be established if the nib wall is found to be the effective, dominant or operative cause of the water ingress. BE, an engineer engaged by the insurer, prepared a report that says the insured property lies within a natural valley and is built into the side of a hill, likely dug down to bedrock. While this provides greater stability, BE notes it is also a disadvantage is it causes surface and subterranean water to flow toward the property through the soil, as the house sits lower than surrounding ground elevation. BE report shows a thorough inspection of the property was conducted. The report is logical and reasoned with well-supported conclusions. It includes photographs, topographical maps and diagrams directly relevant to the cause of damage. A builder engaged by the insurer (SBC) also provides a compelling assessment with background information and supported conclusions. Builder PIB (also engaged by the insurer) provided three reports between 30 June 2020 and 22 September 2022. Each report provides background information, discusses the construction of the dwelling and the damage . These lack the detail of BE and SBC’s reports but are useful in establishing the facts. BE, SBC and PIB all agree:  storms are not the cause of water entry  the nib wall is also not the cause of the water entry  water enters the complainant’s home via the external south-east wall. BE also found evidence of long term water entry to the ground floor, including efflorescence, likely pre- dating the complainant’s p urchase of the property. Determination | Case number: 914775 Page 5 of 11 BE explains a test by the complainant’s expert ( GPR) confirms water penetration via the south-eastern external wall and noted the water ingress continued after the complainant constructed a cut-off drain that was intended to be a preventative measure. SBC and BE provide supporting evidence to show the ground floor was converted from a garage / storeroom to bedrooms and a bathroom without council approval. It was previously a non-habitable space without the waterproofing standards required of habitable spaces. The expert evidence presented by the insurer shows, on balance, stormwater enters the ground floor because of the original building design and inadequate drainage works completed by the complainant, rather than something caused by the nib wall. Maintenance by the complainant has not fixed the cause of water ingress After its 30 June 2020 site visit, PIB said the complainant must install drainage trenches to prevent storm water entering the property, due to the defects in design already discussed above. In its subsequent report of 5 August 2020, PIB also said: Since the event in June 2020 and prior to the recent events the insured has made an attempt to install drainage trenches. We strongly recommend the insured seek advice from an engineer regarding the design of suitable trenches including depths and appropriate materials. SBC says these works were not professionally designed and an engineer was not consulted. Instead, SBC says the complainant completed the works, ‘ with advice from local trades.’ The complainant has not refuted this with any reports or evidence of the advice he received. The findings of BE and SBC in their reports shows the maintenance works completed by the complainant are inadequate to address the identified drainage issues. They do not prevent ongoing water ingress. I am satisfied the proximate cause of the ongoing water ingress is a combination of the dwelling ’s design and the inadequate drainage installed by the complainant. The proximate cause of the water ingress excluded under the policy As discussed above, BE, SBC and PIB all agree storms are not the cause of water entry. I have found the proximate cause of the ongoing water entry is the inadequate drainage installed by the complainant and the dw elling’s design. The policy excludes cover for loss and damage caused by faulty workmanship or faulty design: Under this policy there is no cover provided for any loss, damage or liability caused directly or indirectly by or in any way connection with: 1. defects, structural or design faults, faulty workmanship or faulty design; … Complainant’s submissions do not advance his position The onus rests with the complainant to demonstrate the insurer’s works contributed to the damage. On balance, he has not done so. Determination | Case number: 914775 Page 6 of 11 The pre-purchase building inspector (JBI) does not address water ingress in their report. GPR (a plumber) and the claims adjuster engaged by the complainant (HAV) confirm water ingress continues, which is not in dispute. However, these reports do not refute the conclusions of the insurer ’s experts, particularly those made by BE and SBC. The complainant has not established any connection between the installation of the nib wall and the water ingress. Further, the established cause of the damage is the way the complainant’s home was built such that it is exposed to drainage difficulties, and the drainage the complainant installed has failed addressed the situation effectively. When considered in concert with the indications of damage occurring over a long period of time, this leads to a logical conclusion this is the cause of the continuing water ingress rather than any alleged error by the insurer ’s repairers when the nib wall was installed. 2.2 Should the insurer remove the nib wall? No evidence showing nib wall needs to be removed I am not persuaded the nib wall ought to be removed. This is because BE and SBC both say it is not the cause of water entry and does not require removal even though BE is of the view it was poorly conceived. BE adds: The plinth installation also elevates the built-in robe joinery from the floor slab and is therefore offering some protection from water ingress that occurs between the wall masonry and the concrete floor slab. The available information shows the nib wall provides some protection from water entry, thus minimising damage caused by the building defects already discussed. It would therefore be unreasonable to require the insurer to remove it. 2.3 Is the complainant entitled to compensation? The complainant is not entitled to further compensation Under the AFCA Rules, we can award up to $5,400 compensation for non-financial loss. We will only award this type of compensation if the complainant suffers an unusual degree of stress, inconvenience, or delay because of the insurer ’s handling of the claim. We recognise that making a claim can be stressful and time-consuming, even if the insurer handles the claim correctly. We will not award compensation for the ordinary degree of inconvenience that comes with making a claim. The complainant was dissatisfied with repairs completed by PIB upstairs in the home, according to the second complaint. The insurer fairly addressed this by cash settling the complainant and paying an additional ex gratia amount for service issues. This contributed to a breakdown in the relationship between the complainant and PIB, strained further when he attributed ongoing water ingress to PIB’s installation of the nib wall. The insurer then paid a further ex gratia amount of $10,000 without admitting liability. I am Determination | Case number: 914775 Page 7 of 11 satisfied this represents fair compensation in the circumstances. No further award of compensation is warranted in this complaint. Further, the complainant was told as early as 30 June 2020 to address water entry into the ground floor with expert assistance. He did not obtain that expert assistance and the works have not prevented ongoing water ingress. Further delays have come about while awaiting expert reports which confirm this, not from mismanagement by the insurer. 2.4 Why is the outcome fair? I sympathise with the complainant. I accept it is upsetting for the complainant to have continued water entry into his home. However, the outcome is fair because the damage was not caused by the insurer’s repairer or any insured event under the policy. It would be unfair to require the insurer to rectify or pay for damage it did not cause or is not liable for. Determination | Case number: 914775 Page 8 of 11 3 Supporting information 3.1 The AFCA process AFCA’s approach is based on fairness AFCA has determined this complaint based on what is fair in all the circumstances, having regard to:  the legal principles  applicable industry codes or guidance  good industry practice  previous decisions of AFCA or its predecessor schemes (which are not binding). The respective parties have completed a full exchange of the relevant information, and each party has had the opportunity to address any issues raised. We have reviewed and considered all of the information the parties have provided. While the parties have raised a number of issues in their submissions, we have restricted this determination to the issues that are relevant to the outcome. 3.2 Supporting Information Expert Reports Record Key points Insurer ’s expert (PIB ) Report 23 - 06 - 2020  Damage to water tanks .  Damage to upstairs open plan ceiling, dislodged roof tiles .  Damage to ground fl oor particle flooring, carpets.  Caus e: s trong winds, heavy rain to roof.  Caus e: overflow ing stormwater to ground floor.  Maintenance issues: complainant to install trenches to prevent storm water entering property prior to insurer repair s commencing.  SOW: lower main bedroom , remove and reinstate built in wardrobe for remedial works .  Remove and replace particle floor step . Insurer ’s expert (FEN ) Report 30 - 06 - 2020  Make - safe .  Water seeped un der raised false floor in bedroom, wet, possibly mouldy, needs removal .  Removed carpet and underlay from 2 downstairs bedrooms .  Non - restorable bed frame due to swelling . Insurer ’s expert (CWP ) Report 13 - 07 - 2020  Reports on roof and ceiling damage from storms and wear and tear to roof .  Unrelated to claimed damage in this complaint. Complainant’s expert (ABI ) Report 04 - 08 - 2020  Pre - purc hase inspection report (though property not for sale).  Reports on roof and ceiling damage.  Unrelated to claimed damage in this complaint. Determination | Case number: 914775 Page 9 of 11 Record Key points Insurer ’s expert (PIB ) Report 05 - 08 - 2020  Water entered ceiling upstairs and ground floor again .  Caus e: strong winds, heavy rain to roof and ceilings.  Caus e: overflowing stormwater to ground floor.  ‘Since the event in June 2020 and prior to the recent events the insured has made an attempt to install drainage trenches.’  ‘We strongly recommend the insured seek advice from an engineer regarding the design of suitable trenc hes including depths and appropriate mat erials.’  Recommendation regarding engineer advic e and trenches to preve nt stormwater ingress.  Maintenance issues are the insured’s responsibility. Insurer ’s expert (PIB ) Supplement ary email 26 - 03 - 2021  Waterproofing to foundation walls completed by complainan t without PIB input has been complet ed .  Incorrect installation of drainage trenches by com contributing to water entry. Insurer ’s expert (SBC ) Report 22 - 04 - 2021  Nib wall installed January 2021.  When PIB arrived to complete works in scope of works dated 1 July 2020, noted complainant installation of ‘rough’ waterproofing.  PIB removed this waterproofing and replac ed it with waterproofed nib row of blocks under the wardrobe.  PIB say this was to assist com plainant wit h maintenance wor ks, not to prevent stormwater entry.  Nib wall with wa terproofing is not the cause of wat er ingress.  Storms are not the cause of water ingress.  Complainant reports doing external drainage works himself without hydraulic design / engineering assistance.  Lack of professionally designed hydraulic system is a cause of repeated wat er ingress.  Opinion: external maint enance works ‘failed to arrest stormwater ingress.’  No council approval for conversion of ground floor from class 10a non - hab itable garage to bedrooms also a caus e of water ingress. Insurer ’s expert (SBC ) Report 14 - 06 - 2022  Report on upstairs bathroom repair issues.  Not directly relevant to this claim for ground floor water entry.  Relevant due to service complaint. Complainant’s expert (GPR) Report 02 - 08 - 2022  Plumber / Leak detection  Let hose run for 15 minutes to simulate stormwater.  Test showed wat er, ‘…penetrated existing waterproofing.’  Water entered the nib wall section.  Water then entered carpet of bedroom.  Failed nib wall waterproofing.  Water ingress due to heavy rainfalls, visible at failed waterproofing.  Recommends works to prevent future ingress totalling $52,120. Determination | Case number: 914775 Page 10 of 11 Record Key points Complainant’s expert (HAV) Report 20 - 08 - 2022  Provides GPR report.  GPR report shows insurer’s waterproofing does not work.  Recommends claim acceptance. Insurer ’s expert (PIB ) Report 22 - 09 - 2022  Brick plinth now installed to prevent water ingress via ground floor ‘cut against the rock and dirt.’  Com said PIB installed brick plinth against the cut which did not prevent water ent ry.  Noted com installed agricultural drains around ‘3 high sides of the property.’  Insured responsibility to install adequate drainage.  Insured has been advised of this ma intenance requirement.  Recommend complainant engages an engineer to advise best way to prevent subterranean water entry to house.  Complainant refers to brick plinth installed by PIB as being cause of water ingress.  PIB note house lies towards the bottom of a large hill.  Subterranean water runoff would pass 600mm agricultural drains installed by complainant and hit the cut side of the house.  Rock and soil built up to about 2 metres with concret e path at the top. Insurer ’s expert (BE ) Report 08 - 11 - 202 2  Home dug down to bedrock for stability, making it lower than surrounding ground.  Soil profile cont ribut es to water drainage into home.  Inadequate drainage systems to collect and redirect surface and sub - surface wat er contribute to water ingress.  Plinth to capture water penetrating sout h - eastern external wall and elevate robes inadequate to prevent water e ntry, but not the cause .  Plinth helps water entering built in robes.  Plinth, ‘…well intention but poorly conceived and constructed [sic].’  Plinth can remain in place if maintenance works are complet ed to prevent water entering via south - eastern wall.  Timeline notes complainant purchased property February 2019 and first noted water ingress May 2019.  2019 real estate sales information sho ws roller doors still present and ground floor, ‘...likely to have originally been garages… or workshop areas’ converted to bedrooms before complainant’s 2019 purchase of home.  Images and description of topography show property in a ‘…natural valley’ that runs through the property.  Insured property built into the slope, causing vulnerability to ‘…surface and subsurface water flows.’  29 rainfall events in last ten years over 50mm, classified as rare , including date of loss, 25 March 2021, 71mm.  Rainfall events above 25mm ‘…coincide with issues related to water ingress, particularly in buildings constructed int o the slope of Determination | Case number: 914775 Page 11 of 11 Record Key points the natural ground.’  Water ingress likely pre - dates complainant’s ownership.  GPR res ults from leak d etection test 12 July 2022 show wat er entered via the void space via south - eastern external wall and past nib wall under built - in ward robes.  South - eastern external wall ‘does not appear to incorporate a drainage system of membrane, protective layer, free drain age aggregate and drainage pipe . ’  Black wate r - proofing product applied to the SE external wall internal face sub - floor – unusual effort to address water ingress issues ( not applied by insurer experts ) .  Water - proofing membrane especially unusual as applied to non - habitable space and ineffective , i.e. efflorescence on coated walls.  A pplication on negative pressure side of wall is unusual , typically a last resort.  Water - proofing membrane also unusually applied to ground floor slab, ineffective due to efflorescence and moisture on slab.  C onstruction of cut - off drain has potentially improved surface and sub - surface drainage.  Ov erall, site drainage imperfect, including inadequate drainage at south - eastern wall. Cut - off drain does not seem to have creat ed systems for water flow redirection.  Minimising ingress requires collection and direction of water flows away from the home.  Efflorescence on int ernal face supports conclusion s , as does complainant’s drain installation and wat erproofing membrane  Water entry to ground floor 24 / 25 March 2021 after cut - off drain installatio n demonstrates its inadequacy. Complainant’s expert (JBI) Report (email) 09 - 05 - 2023  Pre - purc hase inspection 24 January 2019.  Hous e structurally sound and in good condition at that time.  Only minor defects identified.  No m ovement observed in foundations, no cracked brickwork.