Home / Hollard / Determination 900653

Determination 900653

Partial decline of storm damage claim for bathroom and ensuite; damage found to be caused over time by poor drainage, inherent defects and leaking shower recesses

FirmHollard
Decided2023-04-06
ProductGeneral Insurance · Home building and contents
OutcomeFor the firm
Amount awarded—
Non-financial loss—
Amount claimed—
SourceAFCA PDF

Summary

The complainant claimed for bathroom and ensuite damage said to be caused by a February 2022 storm. The insurer accepted only the ceiling damage, and AFCA found in favour of the insurer, finding the rest was caused over time and excluded.

Expert evidence showed the proximate cause was long-term inadequate drainage, inherent defects and leaking shower recesses, which the policy excludes, rather than the storm.

Issues

Subjects and remedies

home or building damagenatural disasterno remedy

Related

All Hollard determinations · Find similar determinations

Text of the determination

Determination Case number 900653 Financial firm The Hollard Insurance Company Pty Ltd Determination | Case number: 900653 Page 2 of 6 Case number: 900653 6 April 2023 1 Determination overview 1.1 Complaint The complainant holds a home insurance policy with the financial firm (insurer) and lodged a claim on 11 March 2022 for damage to a bathroom and ensuite caused by a storm on 26 February 2022. The complainant says excessive subfloor moisture caused movement across the property, and this in turn caused leaks and damage. The insurer accepted the internal ceiling damage was caused by the storm. It rejected the balance of the claim and says the damage most likely occurred over time due to inadequate drainage, leaking or faulty shower recesses and inherent defects. The complainant says the damage was caused by the excessive rainfall causing subfloor soil saturation, and the insurer should either pay the claim or negotiate a cash settlement or partial repair. 1.2 Issues and key findings Is the insurer entitled to partially decline the claim? Yes. The insurer’s liability is limited to the ceiling damage sustained in the storm. I am satisfied that the remaining damage was most likely caused over time due to poor site drainage, inherent defects and leaking or faulty shower recesses. Such damage is excluded under the terms of the policy. Why is the outcome fair? There is no dispute the complainant had been provided with the relevant policy documents. The policy sets out the terms and conditions of cover. The available information shows that most likely the damage had occurred overtime due to inherent defects, poor drainage and leaking shower recesses. It did not occur due to the storm event. In the circumstances it is fair for the insurer to rely on the terms and conditions of the policy to refuse payment of the claim. 1.3 Determination This determination is in favour of the insurer. The insurer is entitled to rely on the terms and conditions of the policy to refuse payment of the claim. Determination | Case number: 900653 Page 3 of 6 2 Reasons for determination 2.1 Is the insurer entitled to decline the claim? Yes. The insurer’s liability is limited to the ceiling damage sustained in the storm. I am satisfied the remaining damage was caused over time by poor site drainage, inherent defect and leaking or faulty shower recesses. Such damage is excluded under the terms of the policy. Complainant has initial onus to prove claim falls within terms of policy It is accepted insurance law that an insured has the initial onus to show on the balance of probabilities (that it is more likely than not), that the loss or damage claimed falls within the terms of the policy. Once established, the onus shifts to the insurer to establish, on balance, the application of a policy exclusion or that it is otherwise entitled to decline the claim under the policy. The complainant’s Home Insurance policy provides cover for a series of insured events including:  Storm, rainfall or flood unless caused by water that has seeped or percolated into your building or by gradual deterioration due to rainwater  Escape of liquid unless caused by gradual seepage or a leaking or faulty shower recess An event is defined under the policy as ‘ a single occurrence which you did not intend or expect to happen that results in loss or damage ’. The onus is therefore on the complainant to show that most likely the damage was caused by a single occurrence that was unintended and unexpected. The insurer has accepted liability for storm related damage to the ceilings. The insurers builder MC attended the property on 17 May 2022 and identified cracked roof tiles that were not storm related but a maintenance issue. The insurer agreed to cover the internal ceiling damage as storm related but the complainant was required to complete the maintenance. This aspect of the claim is not in dispute and does not fall part of this determination. Circumstances of claim The complainant had owned the property for approximately 8 years and says the damage first occurred following the heavy rain in February 2022. It is not disputed that there was heavy rainfall at that time. The complainant says this resulted in water pooling beneath her home and subsequent movement of the brick piers supporting the home. The complainant says after the property moved, the showers in the ensuite and main bathroom began to leak, damaging the subfloor and bathroom and further contributing to the moisture issues. She describes issues with mould, and a weak and unsafe bathroom floor. The insurer says the damage is not a result of a single insurable event but is most likely long- term pre-existing damage. The insurer says most likely the damage was caused over time due to a lack of adequate drainage and ventilation, leaking and faulty shower recesses and inherent structural, design or workmanship faults. Determination | Case number: 900653 Page 4 of 6 Expert reports confirm foundation movement The insurer provided reports from a builder (MC), plumber (SLD) and structural engineer (MCS) while the complainant provided a report from EE. MC attended the property on 2 April 2022, and identified structural cracking, the main lounge, hallway and dining sinking at one end, drummy and separating tiles in the bathroom, lifting carpet in two bedrooms and doors sticking. MC considered the damages were caused by building defects and maintenance related issues and not by a one-off storm related event. The complainant provided a building inspection report from architect and builder EE. EE attended the property on 16 May 2022. EE noted water was pooling and drainage issues causing ‘excess swelling and up wood [sic] movement due to the soil being saturated with water which is indicated by the bow and movement of the floor bearer below the dining room’. EE confirmed the leaks from shower recesses in the bathroom, ensuite and widespread movement and cracking across the home. EE recommended a structural engineer be appointed. A structural engineer MCS was engaged on 23 May 2022. MCS considered the lifting and undulations in the floor were caused by uneven movement of the floor framing resulting from movement and tilting of the brick piers. Ground water had seeped under the floor from the southeast side and ponded under the floor which then affected the foundation soil around the piers causing them to tilt. MCS concluded most of the damage was pre-existing prior to the recent heavy rain and has not been directly and solely caused by the single event. The drainage furrows around the brick piers and brick walls indicates the pre-existing conditions which allowed ground surface water to pond around the piers and brick walls. The pre-existing damage was caused by the lack of adequate drainage around the house to divert ground water away from the house. MCS considered the existing drainage provisions do not comply with the minimum ground surface drainage requirement of the Australian Standard – AS2870 Residential slabs and footings Section 5.2 Drainage. A plumber SLD conducted a leak detection test on 6 June 2022. SLD found the master bedroom ensuite had no leak but the shower recess failed the leak detection test. Moisture damage was identified to the yellow tongue flooring. SLD considered movement to brick piers had affected the floor in the ensuite, leading to insufficient grade and subsequent water pooling. The rear (main) bathroom shower recess also failed the leak detection test with water permeating through the edge of the tile bed and into the hallway. Moisture damage was also identified to the bathroom’s yellow tongue flooring. SLD also observed pier related movement in the living room and hallway. SLD considered the damage to the property not recent nor caused by a once-off event but most likely occurred over time due to structural movement and failure of the waterproofing qualities. I am satisfied the experts agree the property has been widely affected by foundation movement. The available information suggests a wet subfloor has caused piers to shift and move, with this movement transferring to the building above. Determination | Case number: 900653 Page 5 of 6 Movement damage caused over time by inadequate site drainage EE says that site drainage requires attention as surface water is entering the subfloor and recommends that the complainant take appropriate action. MCS says there is a lack of adequate drainage around the house to divert water away and that the existing drainage provisions do not comply with relevant standards. MCS supplied an excerpt from the relevant Australian standards. These stipulate that ground should be graded away from a building to achieve a 50 mm fall over the first meter, and subfloors should be graded or drained to prevent water ponding where it may affect the footing system. MCS says there are no provisions to prevent water entering the subfloor, and that scouring and drainage furrows under the subfloor allow water to pool around brick piers. I am persuaded by comments from MCS and EE which indicate drainage at the property is an issue. I am satisfied the expert evidence indicates the damage was caused over time due to the inadequate drainage. Damage to bathrooms and flooring caused by leaking shower recesses The leak detection tests conducted by SLD indicate the damage to the flooring in the ensuite and bathroom was most likely due to leaking or faulty shower recess. Cover under the insured event ‘Escape of liquid’ specifically excludes cover caused by gradual seepage or a leaking or faulty shower recess. I am satisfied based on the report SLD report that the damage has occurred overtime due to the leaking and faulty shower recesses. Insurer is entitled to decline the claim The information indicates that most likely the movement of the building has occurred over several years due to the inadequate drainage and inherent defects. The damage was not due to the storm event within the terms of the policy. While I accept the storm would have caused further ponding of water around the brick piers, I am satisfied that the proximate cause of the damage, that is the dominant or effective cause of the damage was the inadequate drainage and in herent defects which were pre - existing. While I accept the damage was accidental in that it was unintended, I am satisfied based on the information exchanged that the damage claimed most likely occurred over several years and was not caused by an insured event within the terms of the policy. The insurer is entitled to rely on the terms and conditions of the policy to refuse payment of the claim. Further, I am satisfied shower has leaked and caused damage to surrounding rooms. Given the policy excludes damage caused by a leaking or faulty shower base, the insurer is not liable for this damage. 2.2 Why is the outcome fair? There is no dispute the complainant had been provided with the relevant policy documents. The policy sets out the terms and conditions of cover. The available information shows that most likely the damage had occurred overtime due to inherent defects, poor drainage and leaking shower recesses. It did not occur due to the storm event. In the circumstances it is fair for the insurer to rely on the terms and conditions of the policy to refuse payment of the claim. Determination | Case number: 900653 Page 6 of 6 3 Supporting information 3.1 The AFCA process AFCA ’s approach is based on fairness AFCA has determined this complaint based on what is fair in all the circumstances, having regard to:  the legal principles  applicable industry codes or guidance  good industry practice  previous decisions of AFCA or its predecessor schemes (which are not binding). The respective parties have completed a full exchange of the relevant information, and each party has had the opportunity to address any issues raised. We have reviewed and considered all the information the parties have provided. While the parties have raised several issues in their submissions, we have restricted this determination to the issues that are relevant to the outcome. We assess complaints on available information and circumstances AFCA is not a court of law. We do not have the power to take or test evidence on oath, or to require third parties to give evidence. When we assess complaints, we consider:  available documents  the recollections of the parties  all relevant circumstances. We give more weight to documents created at the time the events occurred. If there are no relevant documents, we will decide what most likely occurred based on the available information. If there are conflicting recollections and these are evenly weighted, we may find that a claim cannot be established.

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.