Home / Hollard / Determination 900653
Determination 900653
Partial decline of storm damage claim for bathroom and ensuite; damage found to be caused over time by poor drainage, inherent defects and leaking shower recesses
Summary
The complainant claimed for bathroom and ensuite damage said to be caused by a February 2022 storm. The insurer accepted only the ceiling damage, and AFCA found in favour of the insurer, finding the rest was caused over time and excluded.
Expert evidence showed the proximate cause was long-term inadequate drainage, inherent defects and leaking shower recesses, which the policy excludes, rather than the storm.
Issues
- Claim denial primary · not upheld“The insurer is entitled to rely on the terms and conditions of the policy to refuse payment of the claim.”
Subjects and remedies
home or building damagenatural disasterno remedy
Related
Text of the determination
Determination
Case number 900653
Financial firm The Hollard Insurance Company Pty Ltd
Determination | Case number: 900653 Page 2 of 6
Case number: 900653 6 April 2023
1 Determination overview
1.1 Complaint
The complainant holds a home insurance policy with the financial firm (insurer) and lodged a
claim on 11 March 2022 for damage to a bathroom and ensuite caused by a storm on 26
February 2022. The complainant says excessive subfloor moisture caused movement across
the property, and this in turn caused leaks and damage.
The insurer accepted the internal ceiling damage was caused by the storm. It rejected the
balance of the claim and says the damage most likely occurred over time due to inadequate
drainage, leaking or faulty shower recesses and inherent defects.
The complainant says the damage was caused by the excessive rainfall causing subfloor soil
saturation, and the insurer should either pay the claim or negotiate a cash settlement or
partial repair.
1.2 Issues and key findings
Is the insurer entitled to partially decline the claim?
Yes. The insurer’s liability is limited to the ceiling damage sustained in the storm. I am
satisfied that the remaining damage was most likely caused over time due to poor site
drainage, inherent defects and leaking or faulty shower recesses. Such damage is excluded
under the terms of the policy.
Why is the outcome fair?
There is no dispute the complainant had been provided with the relevant policy documents.
The policy sets out the terms and conditions of cover.
The available information shows that most likely the damage had occurred overtime due to
inherent defects, poor drainage and leaking shower recesses. It did not occur due to the
storm event.
In the circumstances it is fair for the insurer to rely on the terms and conditions of the policy to
refuse payment of the claim.
1.3 Determination
This determination is in favour of the insurer.
The insurer is entitled to rely on the terms and conditions of the policy to refuse payment of
the claim.
Determination | Case number: 900653 Page 3 of 6
2 Reasons for determination
2.1 Is the insurer entitled to decline the claim?
Yes. The insurer’s liability is limited to the ceiling damage sustained in the storm. I am
satisfied the remaining damage was caused over time by poor site drainage, inherent defect
and leaking or faulty shower recesses. Such damage is excluded under the terms of the
policy.
Complainant has initial onus to prove claim falls within terms of policy
It is accepted insurance law that an insured has the initial onus to show on the balance of
probabilities (that it is more likely than not), that the loss or damage claimed falls within the
terms of the policy. Once established, the onus shifts to the insurer to establish, on balance,
the application of a policy exclusion or that it is otherwise entitled to decline the claim under
the policy.
The complainant’s Home Insurance policy provides cover for a series of insured events
including:
Storm, rainfall or flood unless caused by water that has seeped or percolated into your
building or by gradual deterioration due to rainwater
Escape of liquid unless caused by gradual seepage or a leaking or faulty shower recess
An event is defined under the policy as ‘ a single occurrence which you did not intend or
expect to happen that results in loss or damage ’.
The onus is therefore on the complainant to show that most likely the damage was caused by
a single occurrence that was unintended and unexpected.
The insurer has accepted liability for storm related damage to the ceilings. The insurers
builder MC attended the property on 17 May 2022 and identified cracked roof tiles that were
not storm related but a maintenance issue. The insurer agreed to cover the internal ceiling
damage as storm related but the complainant was required to complete the maintenance.
This aspect of the claim is not in dispute and does not fall part of this determination.
Circumstances of claim
The complainant had owned the property for approximately 8 years and says the damage first
occurred following the heavy rain in February 2022. It is not disputed that there was heavy
rainfall at that time. The complainant says this resulted in water pooling beneath her home
and subsequent movement of the brick piers supporting the home.
The complainant says after the property moved, the showers in the ensuite and main
bathroom began to leak, damaging the subfloor and bathroom and further contributing to the
moisture issues. She describes issues with mould, and a weak and unsafe bathroom floor.
The insurer says the damage is not a result of a single insurable event but is most likely long-
term pre-existing damage. The insurer says most likely the damage was caused over time
due to a lack of adequate drainage and ventilation, leaking and faulty shower recesses and
inherent structural, design or workmanship faults.
Determination | Case number: 900653 Page 4 of 6
Expert reports confirm foundation movement
The insurer provided reports from a builder (MC), plumber (SLD) and structural engineer
(MCS) while the complainant provided a report from EE.
MC attended the property on 2 April 2022, and identified structural cracking, the main lounge,
hallway and dining sinking at one end, drummy and separating tiles in the bathroom, lifting
carpet in two bedrooms and doors sticking. MC considered the damages were caused by
building defects and maintenance related issues and not by a one-off storm related event.
The complainant provided a building inspection report from architect and builder EE. EE
attended the property on 16 May 2022. EE noted water was pooling and drainage issues
causing ‘excess swelling and up wood [sic] movement due to the soil being saturated with
water which is indicated by the bow and movement of the floor bearer below the dining room’.
EE confirmed the leaks from shower recesses in the bathroom, ensuite and widespread
movement and cracking across the home. EE recommended a structural engineer be
appointed.
A structural engineer MCS was engaged on 23 May 2022. MCS considered the lifting and
undulations in the floor were caused by uneven movement of the floor framing resulting from
movement and tilting of the brick piers. Ground water had seeped under the floor from the
southeast side and ponded under the floor which then affected the foundation soil around the
piers causing them to tilt.
MCS concluded most of the damage was pre-existing prior to the recent heavy rain and has
not been directly and solely caused by the single event. The drainage furrows around the
brick piers and brick walls indicates the pre-existing conditions which allowed ground surface
water to pond around the piers and brick walls.
The pre-existing damage was caused by the lack of adequate drainage around the house to
divert ground water away from the house. MCS considered the existing drainage provisions
do not comply with the minimum ground surface drainage requirement of the Australian
Standard – AS2870 Residential slabs and footings Section 5.2 Drainage.
A plumber SLD conducted a leak detection test on 6 June 2022. SLD found the master
bedroom ensuite had no leak but the shower recess failed the leak detection test. Moisture
damage was identified to the yellow tongue flooring. SLD considered movement to brick piers
had affected the floor in the ensuite, leading to insufficient grade and subsequent water
pooling.
The rear (main) bathroom shower recess also failed the leak detection test with water
permeating through the edge of the tile bed and into the hallway. Moisture damage was also
identified to the bathroom’s yellow tongue flooring. SLD also observed pier related movement
in the living room and hallway.
SLD considered the damage to the property not recent nor caused by a once-off event but
most likely occurred over time due to structural movement and failure of the waterproofing
qualities.
I am satisfied the experts agree the property has been widely affected by foundation
movement. The available information suggests a wet subfloor has caused piers to shift and
move, with this movement transferring to the building above.
Determination | Case number: 900653 Page 5 of 6
Movement damage caused over time by inadequate site drainage
EE says that site drainage requires attention as surface water is entering the subfloor and
recommends that the complainant take appropriate action. MCS says there is a lack of
adequate drainage around the house to divert water away and that the existing drainage
provisions do not comply with relevant standards.
MCS supplied an excerpt from the relevant Australian standards. These stipulate that ground
should be graded away from a building to achieve a 50 mm fall over the first meter, and
subfloors should be graded or drained to prevent water ponding where it may affect the
footing system. MCS says there are no provisions to prevent water entering the subfloor, and
that scouring and drainage furrows under the subfloor allow water to pool around brick piers.
I am persuaded by comments from MCS and EE which indicate drainage at the property is an
issue. I am satisfied the expert evidence indicates the damage was caused over time due to
the inadequate drainage.
Damage to bathrooms and flooring caused by leaking shower recesses
The leak detection tests conducted by SLD indicate the damage to the flooring in the ensuite
and bathroom was most likely due to leaking or faulty shower recess.
Cover under the insured event ‘Escape of liquid’ specifically excludes cover caused by
gradual seepage or a leaking or faulty shower recess. I am satisfied based on the report SLD
report that the damage has occurred overtime due to the leaking and faulty shower recesses.
Insurer is entitled to decline the claim
The information indicates that most likely the movement of the building has occurred over
several years due to the inadequate drainage and inherent defects. The damage was not due
to the storm event within the terms of the policy. While I accept the storm would have caused
further ponding of water around the brick piers, I am satisfied that the proximate cause of the
damage, that is the dominant or effective cause of the damage was the inadequate drainage
and in herent defects which were pre - existing.
While I accept the damage was accidental in that it was unintended, I am satisfied based on
the information exchanged that the damage claimed most likely occurred over several years
and was not caused by an insured event within the terms of the policy. The insurer is entitled
to rely on the terms and conditions of the policy to refuse payment of the claim.
Further, I am satisfied shower has leaked and caused damage to surrounding rooms. Given
the policy excludes damage caused by a leaking or faulty shower base, the insurer is not
liable for this damage.
2.2 Why is the outcome fair?
There is no dispute the complainant had been provided with the relevant policy documents.
The policy sets out the terms and conditions of cover.
The available information shows that most likely the damage had occurred overtime due to
inherent defects, poor drainage and leaking shower recesses. It did not occur due to the
storm event.
In the circumstances it is fair for the insurer to rely on the terms and conditions of the policy to
refuse payment of the claim.
Determination | Case number: 900653 Page 6 of 6
3 Supporting information
3.1 The AFCA process
AFCA ’s approach is based on fairness
AFCA has determined this complaint based on what is fair in all the circumstances, having
regard to:
the legal principles
applicable industry codes or guidance
good industry practice
previous decisions of AFCA or its predecessor schemes (which are not binding).
The respective parties have completed a full exchange of the relevant information, and each
party has had the opportunity to address any issues raised. We have reviewed and
considered all the information the parties have provided.
While the parties have raised several issues in their submissions, we have restricted this
determination to the issues that are relevant to the outcome.
We assess complaints on available information and circumstances
AFCA is not a court of law. We do not have the power to take or test evidence on oath, or to
require third parties to give evidence.
When we assess complaints, we consider:
available documents
the recollections of the parties
all relevant circumstances.
We give more weight to documents created at the time the events occurred. If there are no
relevant documents, we will decide what most likely occurred based on the available
information.
If there are conflicting recollections and these are evenly weighted, we may find that a claim
cannot be established.
Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.