Text of the determination
Determination
Case number 886703
Financial firm AAI Limited
Determination | Case number: 886703 Page 1 of 6
Case number: 886703 22 December 2022
1 Determination overview
1.1 Complaint
The complainant, Mr C, holds a home building insurance policy with the financial firm
(insurer). On 4 February 2022 Mr C contacted the insurer and advised that his house was
damaged on 1 February 2022 because of an earthquake. Mr C ‟s house is located at C,
Western Australia. The earthquake‟s epicentre was 100 kilometres from C. The earthquake
was a 4.3 magnitude earthquake. Mr C initially sought compensation but was unsure about
the amount. He estimated the amount as being between $1,000 and $5,000. He later sought
repair of the damage. He recently said that he might be receptive to a cash settlement.
The insurer declined Mr C‟s claim. The insurer acknowledges that there was an earthquake
and that the house has been damaged. The insurer says that the damage was not caused by
the earthquake. The insurer says the damage was caused by the settling of recently replaced
stumps, and battens not being adequately attached to a load bearing beam that was installed
when a wall was removed.
1.2 Issues and key findings
Is the insurer entitled to decline the claim?
The insurer is entitled to decline the claim. Under the policy the insurer covers damage
caused by specified events. The only relevant specified event is an earthquake. The evidence
shows that the proximate cause of the damage to Mr C ‟s house was the settling of recently
replaced stumps, and battens not being adequately attached to a load bearing beam that was
installed when a wall was removed. Further, the policy specifically excludes damage caused
by the settling.
Why is the outcome fair?
The damage to Mr C‟s house is unfortunate and is damage that Mr C did not expect. The
proximate causes of the damage to the house do not involve an earthquake. Accordingly, the
damage is not covered by the policy. Further, the policy specifically excludes from cover
damage arising from one of the proximate causes identified. In these circumstances it would
not be fair to require the insurer to compensate Mr C for the damage to his house.
1.3 Determination
This determination is in favour of the insurer. The insurer is not required to pay compensation.
Determination | Case number: 886703 Page 2 of 6
2 Reasons for determination
2.1 Is the insurer entitled to decline the claim?
The insurer is entitled to decline the claim. Under the policy the insurer covers damage
caused by specified events. The only relevant specified event is an earthquake. The evidence
shows that the proximate cause of the damage to Mr C‟s house was the settling of recently
replaced stumps, and battens not being adequately attached to a load bearing beam that was
installed when a wall was removed. Further, the policy specifically excludes damage caused
by the settling.
Complainant has initial onus to establish a valid claim
The initial onus is with the complainant to establish on the balance of probabilities (that is
more likely than not) that the loss or damage claimed falls within the terms of the policy. This
is known as a valid (or prima facie ) claim.
Once the complainant has established a valid claim, the onus shifts to the insurer to establish,
on balance, the application of a policy exclusion or that it is otherwise entitled to decline the
claim under the policy.
Information must show the proximate cause of the damage is earthquake
The policy is an „insured events‟ policy. This means not all loss and damage is automatically
covered. Rather, only loss or damage caused by one or more of the insured events, and not
subject to exclusions, is covered. Earthquake is an insured event.
When an insurance policy uses the term „caused by‟, this typically means proximate cause.
Proximate cause is a question of fact depending on the circumstances. The proximate cause
is not necessarily the first or last or the sole cause of the loss. It is the effective, dominant or
operative cause of the loss.
Therefore, to establish a valid claim, the available information must show the cause of the
damage claimed is earthquake.
Complainant says an earthquake caused damage to his property
Mr C says that an earthquake caused damage to his house.
Prior to the earthquake Mr C‟s house was renovated as follows:
the floor was levelled in August 2021 when new stumps were installed under the floor;
following the levelling, a wardrobe was installed in the main bedroom; and
a load bearing beam was installed when a wall was removed.
Following the earthquake, Mr C noticed that:
the floor („the north edge of our house had su nk evenly‟) , wardrobe and kitchen sink were
not level; and
the ceiling near the load bearing beam was bowed.
Mr C says that:
it is apparent that the earthquake affected the house because soil had been pushed away
from the four sides of the stumps; and
the even sinking of the north edge of his house shows that the floor not being level was
due to the earthquake, not the settling of stumps.
Determination | Case number: 886703 Page 3 of 6
Insurer provided reports commenting on the cause of damage
The insurer appointed M, engineers and building consultants, to inspect the house and report
on the damage. M prepared three reports dated 6 April 2022, 5 October 2022 (the report
dated 5 October 2022 addressed Mr C‟s response to the report dated 6 April 2022) and 23
November 2022. Neither the report dated 5 October 2022, nor the report dated 23 November
2022, amended what was said in an earlier report.
The reports show that the damage was not caused by the earthquake. The reports show that
the damage was caused by the settling of recently replaced stumps, and battens not being
adequately attached to a load bearing beam that was installed when a wall was removed.
Complainant raised issues about the first report’s reasoning
The report dated 6 April 2022 says:
the wardrobe, kitchen sink and floor are not level;
the ceiling near the load bearing beam is bowed;
due to the earthquake „Light shaking was experienced in the vicinity of the insured
property‟;
„3 stumps on the southern side of the property show signs of horizontal movement
consistent with “shaking” of the dwelling [… ], they do not show signs of sudden vertical
movement that would cause the observed damage‟ ;
the damage was not due to the earthquake, rather the „ proximate cause of the damage are
as follows:
- „Normal settlement of the dwelling after it was restumped 6 months prior to the event‟;
and
- „The ceiling is inadequately supported from an LVL installed when the kitchen/lounge
wall was removed in the past‟ („LVL‟ is an acronym for laminated veneer lu mber); and
„The LVL beam installed in the ceiling between the lounge an d kitchen is not adequately
supporting the ceiling battens running beneath it‟.
Mr C ‟s response to the report dated 6 April 2022 included many photos. The response:
refers to the possibility that a carport „could have transferred vibrational force through the
home to place stress on the stumping on the northern side of the house‟;
refers to a stump that the report dated 6 April 2022 said was bowed (the report dated 6
April 2022 said that the bowed stump „is not of significant concern‟ and does not say that
the bow stumped contributed to the damage – hence, whether the stump was bowed or
not, is irrelevant);
says that horizontal shaking could cause the stumps to move vertically by sinking (and
refers to an example of this as being where the twisting of feet in wet beach sand causes
the feet to sink);
says that no allowance was made for „hexed bugle head timber screws screwed into the
ceiling beams‟; and
says that where there seems to be no fastener another inspection by M would have shown
that there was a fastener on the other side of the load bearing beam.
It is apparent that Mr C was not comfortable with what the first report says about the effect of
the earthquake on the stumps and the workmanship concerning the load bearing beam.
Determination | Case number: 886703 Page 4 of 6
Subsequent reports addressed the issues raised by complainant
The report dated 5 October 2022 addressed Mr C‟s response. It says :
the carport may have transferred force, however, no damage was observed where the
carport connected to the house and, if there was a transfer, movement in the stumps
would have been horizontal, not vertical;
regarding the timber screws, more reliable brackets should have been used „as drilling
from softwood into the hardwood battens may have caused splitting, and a bracket is much
more reliable‟ ;
regarding Mr C‟s photos, „ there appears to be no support of the batten under the electrical
cut-out […] and another screw appears to have “missed” the ceiling batten , (or likely split
it)‟; and
a rare set of soil conditions must exist before earthquakes cause „settlements‟ (significant
vibration, low density soil and saturated soil) and two of these rare conditions did not exist
(low density soil and saturate soil).
The report dated 5 October 2022 additionally says:
„Upon reviewing the insured‟s letter, plus additional geote chnical and weather data, I am
still of the opinion that the damage at the insured proper ty is NOT related to the event‟;
„ The relatively flexible timber construction of the insured property makes it significantly less
susceptible to earthquake damage than stiffer masonry structures‟;
„ There are masonry structures in the vicinity of the insured property ‟;
„ I spoke with the local shire of C, (and W / N ) on the telephone and they had no reports of
any damage, (tim ber or masonry)‟; and
t he „Modified Mercalli Intensity scale‟ (MMI) indicates that „shaking‟ at the insured property
was weak to light with no resulting damage.
The report dated 23 November 2022 further addressed the issue concerning the bowed
ceiling. It says:
„ The sagging ceiling was one of a few things I looked at, and the insured stated in their
letter {***** Letter from insured AAMI Claim no *******760 (attached e-mail)} that the beam
was previously installed to correct the sagging ceiling, i.e. implying it was a pre-existing
issue. The insured also mentions a receipt for the works, but we were not provided with it ‟;
and
„If the ceiling were previously sagging then it‟s probable that the old jarrah battens had
permanently deformed, and the only way to fully correct it would be to replace them, (in
addition to adding the beam)‟.
The report dated 23 November 2022 then refers to:
the ceiling battens, and ceiling, being heavier than modern ceiling battens; and
the screws not being inserted according to good practice in that they were inserted such
that there was „ tension ‟ which encouraged the screws to pull out of the timber.
The subsequent reports show that what the first report says about the effect of the
earthquake on the stumps and the workmanship concerning the load bearing is sound.
Policy excludes damage due to normal settlement
M‟s reports show that the proximate cause of the damage was normal settlement following
restumping and a load bearing beam inadequately supporting the ceiling.
Normal settlement comes within one of the policy exclusions. The policy excludes from cover
damage caused by ground movement (which is defined as including subsidence, shrinkage or
Determination | Case number: 886703 Page 5 of 6
any other earth movement) unless the ground movement resulted from a flood, a storm, a
storm surge, an earthquake, a tsunami or an escape of liquid.
The damage resulting from a load bearing beam inadequately supporting the ceiling does not
come within a policy exclusion. The insurer refers to exclusions headed „ Wear, tear and
gradual deterioration‟ and „Ground movement‟. A failure to ensure that an installed l oad
bearing beam adequately supported a ceiling does not involve wear, tear, gradual
deterioration or ground movement.
The insurer also refers to exclusions headed „Defects, fault, workmanship‟ . The policy says
that it does not cover „Defects, faults, workmanship‟ and describes these matters as follows:
„loss or damage caused by, connected with or arising from, or liability caused by,
connected with or arising from inherent defects, faulty design, structural defects, structural
fault or faulty/poor workmanship (e.g. structural posts, beams or load bearing walls have
been removed without taking into account structural engineering requirements), if you
knew or should have reasonably known about it (e.g. because the defect or fault was able
to be observed by you or because it was identified in a pre-purchase building inspection
report)‟;
„any loss or damage to the part of the building with an inherent defect, faulty design,
structural defect or faulty/poor workmanship, whether or not you knew or should
reasonably h ave known about it‟.
There is no evidence that Mr C (or others covered by the policy) knew or should have known
that the load bearing beam inadequately supported the ceiling.
The insurer is entitled to decline the claim
The information does not show that the proximate causes of the damage to the house
involved an earthquake.
M‟s reports make the following critical findings:
the earthquake caused light horizontal shaking;
only if the earthquake has caused vertical movement would the damage have been
caused by the earthquake;
there was no vertical movement; and
the proximate causes of the damage to the house do not involve an earthquake.
Those conclusions are supported by sound reasoning and address Mr C‟s response to these
conclusions. The reports find that normal settlement is the proximate cause of some of the
damage to Mr C‟s property. This is not an insured event. It is also excluded under Mr C‟s
policy.
For these reasons I am satisfied the insurer is entitled to decline the claim.
2.2 Why is the outcome fair?
The damage to Mr C‟s house is unfortunate and is damage that Mr C did not expect. The
proximate causes of the damage to the house do not involve an earthquake. Accordingly, the
damage is not covered by the policy. Further, the policy specifically excludes from cover
damage arising from one of the proximate causes identified. In these circumstances it would
not be fair to require the insurer to compensate Mr C for the damage to his house.
Determination | Case number: 886703 Page 6 of 6
3 Supporting information
3.1 The AFCA process
AFCA’s approach is based on fairness
AFCA has determined this complaint based on what is fair in all the circumstances, having
regard to:
the legal principles
applicable industry codes or guidance
good industry practice
previous decisions of AFCA or its predecessor schemes (which are not binding).
The respective parties have completed a full exchange of the relevant information, and each
party has had the opportunity to address any issues raised. We have reviewed and
considered all of the information the parties have provided.
While the parties have raised a number of issues in their submissions, we have restricted this
determination to the issues that are relevant to the outcome.
We assess complaints on available information and circumstances
AFCA is not a court of law. We do not have the power to take or test evidence on oath, or to
require third parties to give evidence.
When we assess complaints, we consider:
available documents
the recollections of the parties
all relevant circumstances.
We give more weight to documents created at the time the events occurred. If there are no
relevant documents, we will decide what most likely occurred based on the available
information.
If there are conflicting recollections and these are evenly weighted, we may find that a claim
cannot be established.