Claim declined for property damage allegedly caused by stormwater overflow and leaking stormwater pipe
Text of the determination
Determination
Case number 883896
Financial firm AAI Limited
Determination | Case number: 883896 Page 1 of 9
Case number: 883896 10 February 2023
1 Determination overview
1.1 Complaint
The complainant holds a landlord insurance policy with the insurer. On 21 March 2021, the
complainant lodged a claim for damage to his property caused by stormwater overflowing
from the gutters and a leaking stormwater pipe underground.
The insurer declined the claim and said the damage is not consistent with an insured event
under the policy. It says the complainant has not established a valid claim under the policy.
Further, it says the damage is due to ground movement.
The complainant disagrees with the insurer’s decision and seeks that the damage be
covered.
1.2 Issues and key findings
Is the insurer entitled to decline the claim?
Yes. The complainant has not established that the damage to the property was caused by an
insured event. On balance, the proximate cause of the damage is differential movement
which has occurred gradually due to long term seasonal movement of the moderately reactive
soil, truss creep and inadequate back-blocking. Accordingly, the insurer is entitled to decline
the claim.
Why is the outcome fair?
The complainant has not established a valid claim under the policy. Therefore, the insurer is
entitled to decline the claim. It would not be fair, in the circumstances, to require the insurer
to cover the claim.
1.3 Determination
This determination is in favour of the insurer.
The insurer is entitled to decline the claim. It is not required to take any further action in
relation to the claim or the complaint.
Determination | Case number: 883896 Page 2 of 9
2 Reasons for determination
2.1 Is the insurer entitled to decline the claim?
Yes. The complainant has not established that the damage to the property was caused by an
insured event. On balance, the proximate cause of the damage is differential movement
which has occurred gradually due to long term seasonal movement of the moderately reactive
soil, truss creep and inadequate back-blocking. Accordingly, the insurer is entitled to decline
the claim.
Onus on complainant to establish valid claim
The initial onus is with the complainant to establish, on the balance of probabilities (that it is
more likely than not), that the loss or damage claimed falls within the terms of the policy. This
is known as a valid (or prima facie ) claim.
Once the complainant has established a valid claim, the onus shifts to the insurer to establish,
on balance, the application of a policy exclusion or that it is otherwise entitled to decline the
claim under the policy.
Policy covers insured events subject to exclusions
The insurer’s policy consists of the policy schedule and product disclosure statement (PDS).
It is not in dispute the insurer provided the policy documents to the complainant.
The policy is an ‘insured events’ policy. This means not all loss and damage is automatically
covered. Rather, only loss or damage caused by one or more of the insured events, and not
subject to exclusions, is covered.
The insured events are set out in the PDS and include storm and escape of liquid events.
However, the PDS states that cover for storm and/or escape of liquid does not include:
- loss or damage caused by erosion, vibration, subsidence, landslip, landslide,
mudslide, collapse, shrinkage or any other earth movement, but we will cover
loss or damage caused by a landslide or subsidence proved to have occurred
within 72 hours of, and directly because of, a storm and not because of
erosion, structural fault or design fault;
Cover for an escape of liquid event also excludes:
- wear, tear and gradual deterioration or loss or damage by the gradual process
of liquid leaking, splashing, dripping or overflowing;
The policy also generally excludes cover for loss or damage to, or caused by, connected with
or arising from:
Ground movement
erosion, vibration, subsidence, landslip, landslide, mudslide, collapse, shrinkage
or any other earth movement, but we will cover landslide or subsidence that is
specifically covered under the following insured events:
Determination | Case number: 883896 Page 3 of 9
- ‘Storm’ page 46;…
Complainant says damage caused by escape of liquid and storm
The complainant says:
after the claim was lodged, the stormwater drain repairs were completed by a plumber,
BSP, to parts of the pipe at the rear right corner of the dwelling, front right corner of the
dwelling and the junction connection at the front of the property. Following this, a
certificate of compliance was issued on 22 July 2021;
it obtained a report from a building inspector, OBI, who confirmed the damage to the
property is as a result of settlement caused by leaks from the stormwater pipe. OBI says:
> there is a gap between the brick wall and lintel on the north-west elevation which is
consistent with significant settlement in the slab in the front room;
> the settlement of the slab has pulled down the timber frame of the wall and,
consequently, the roof structure;
> excessive movements in the timber frame has caused detachment of plasterboards and
cracks on the walls and ceilings;
> there is no sign of damage to floor tiles which is likely because settlement has not
extended to the middle of the building where the kitchen and living room is located;
> sections of the ceiling are sagging. This is likely to be due to building materials coming
loose and requiring reattachment. There are also gaps between window and brick and
brick and eave sheets, which are all signs of movement; and
> underpinning of the slab can stabilise the footings and the damage to the plasterboard
on the ceilings and walls can be fixed after this occurs.
Insurer provided reports commenting on the cause of damage
The insurer engaged a plumber, SP, who says:
it identified four major areas of concern in relation to the stormwater pipe;
there is evidence of structural damage throughout the property;
due to the four areas of concern, water is leaking underground which in turn could be
causing ground movement and possible damage to the property; and
it recommends an engineer be appointed to further assess these issues.
The insurer also appointed an engineer, IL, to report on the cause of the damage. It says:
the majority of the internal damage to the dwelling consists of ceiling cracking, cornice
crushing and wall plaster damage;
the issues with the storm water pipe and the escape of liquid have not caused the internal
damage to the property. This is because if the escape of liquid was the cause of the
damage, it would expect the movement to be localised. It would also expect to see
exterior wall rotation. There is no evidence of either rotation or localised movement. The
floor level survey also does not show localised heaving or contouring to suggest the
escape of liquid was the cause of the movement;
further, an inspection of the roof cavity showed no defects or damage to the timber roof
trusses or node connections. There was also no evidence of water damage to the plaster
roof sheets;
the internal damage to the dwelling has been caused by truss creep (the plaster ceiling is
directly affixed to the bottom chord and hence any deflection in the trusses will be
transferred through the plaster sheeting) and the incorrect installation of back blocking
over the joints of the ceiling plaster (the cornices are directly fixed to the plaster ceiling
Determination | Case number: 883896 Page 4 of 9
walls, these same forces are transferred through the truss and ceiling battens into ceiling
plaster and cornices which results in crushing of the brittle plaster finishes);
the back-blocking installation at the dwelling is completely insufficient and provides
absolutely no restraint or support to the plasterboard sheets. The back-blocking sections
are sporadically located and do not extend along the entire joint;
the negligible to slight cracking to the wall plaster at the top of window and door openings
has been caused by natural seasonal movement of the moderately reactive class M soils;
real estate listings confirm that the patch repairs to the ceiling plaster existed prior to the
complainant purchasing the property in 2013. There is also evidence of water damage to
the lounge room carpet;
the non-compliant and undersized eaves gutters, and there being no rainhead, sump or
other overflow provision, has caused the extensive mould and water staining. This also
confirms water entry inside the building;
the storm water system does not comply with Australian Standards. The system should be
upgraded or else water ingress will continue to occur; and
the damage to the property has been caused by long term, ongoing natural seasonal
movement of the moderately reactive founding soils, evident by the previous repairs
completed dating back to at least 2013.
Proximate cause of the damage must be established
The complainant needs to show the proximate cause of the damage being claimed is, on
balance, the storm and/or escape of liquid event, which is not otherwise excluded.
The proximate cause of a loss is the dominant, effective or operative cause. It does not have
to be the first, the last or the sole cause. This is a question of fact depending on the
circumstances.
If there are several causes, each needs to be examined for qualities of reality, predominance
and efficiency to identify the proximate cause. For example, if one cause would have caused
the loss in any case, and the other one would not have done so without the first, then the first
is the proximate cause.
Available information does not show damage due to storm
Having reviewed all the available information, I am not satisfied, on balance, that the
complainant has established that the property damage has been caused by a storm or an
escape of liquid event.
I accept that the complainant has provided evidence regarding the damage to the stormwater
pipe and the escape of liquid. However, I am not satisfied that it has established that these
defects and/or the escape of liquid caused the damage to the property. I note in this regard
that the cracking is throughout the property and is not localised to the areas of defective or
leaking stormwater pipe. I also accept that the floor level survey does not show any
significant differential either generally or at the location of the stormwater pipe defects. The
complainan t’s evidence also does not address the soil classification of the site nor the
movement that can occur as a result.
I am satisfied that IL is sufficiently qualified to assess and comment on the cause of the
damage at the property. In this regard, I am persuaded by its reasoning that the cause of the
damage is long term ongoing natural seasonal movement of the moderately reactive founding
soils. I am satisfied that the movement, along with the truss creep and the inadequate back-
blocking is the proximate cause of the damage.
Determination | Case number: 883896 Page 5 of 9
I note also that the advertising images provided suggest the ceiling cracking has been
occurring since at least 2013 and that patch repairs have been conducted since that time.
Given there is no clear connection between the areas of damage and the location of the
defective pipe, I am not satisfied the complainant has established the claimed damage is a
result of the defects in the stormwater pipe. I consider, on balance, the proximate cause of
the damage is a result of the long term ongoing movement of the soil, truss creep and
inadequate back blocking.
Accordingly, the insurer is entitled to decline the claim. It is not required to take any further
action in relation to the claim or the complaint.
2.2 Why is the outcome fair?
The complainant has not established a valid claim under the policy. Therefore, the insurer is
entitled to decline the claim. It would not be fair, in the circumstances, to require the insurer
to cover the claim.
Determination | Case number: 883896 Page 6 of 9
3 Supporting information
3.1 The AFCA process
AFCA’s approach is based on fairness
AFCA has determined this complaint based on what is fair in all the circumstances, having
regard to:
the legal principles
applicable industry codes or guidance
good industry practice
previous decisions of AFCA or its predecessor schemes (which are not binding).
The respective parties have completed a full exchange of the relevant information, and each
party has had the opportunity to address any issues raised. We have reviewed and
considered all of the information the parties have provided.
While the parties have raised a number of issues in their submissions, we have restricted this
determination to the issues that are relevant to the outcome.
We assess complaints on available information and circumstances
AFCA is not a court of law. We do not have the power to take or test evidence on oath, or to
require third parties to give evidence.
When we assess complaints, we consider:
available documents
the recollections of the parties
all relevant circumstances.
We give more weight to documents created at the time the events occurred. If there are no
relevant documents, we will decide what most likely occurred based on the available
information.
If there are conflicting recollections and these are evenly weighted, we may find that a claim
cannot be established.
Determination | Case number: 883896 Page 7 of 9
3.2 Summary of reports provided by the parties
Record Key points
Complainant’s expert
report - BSP ( plumber )
tree roots had been located entering the broken section of stormwater
pipe under the garage;
the issue is located below the conc rete slab;
the drain in this area is holding water in several areas;
the tree roots in the drain is causing water restriction in the pipe; and
it recommends cutting out and replacing the broken and tree root
section s of pipe, installi ng a concrete pit, connecting the storm water
drain to the pit and reinstating the concrete slab around the new pit.
Complainant’s expert
report - OBI ( building
inspector )
there is a major structural defect on the north - west elevation,
comprising the displacement of the wall from its original location in
several locations. There is also movement in the brick wall leaving a
gap between brick and lintel. This is consistent with significant
settlement in the slab in the front room;
various damage and de fects were observed internally including
unleveling of floors and damage to plasterboard, ceilings, walls and
doors. There was no sign of damage to floor tiles which is likely
because settlement has not extended to the middle of the building
where the kit chen and living room is located;
the internal damage is consistent with the slab having tilted toward
the front part of the building;
sections of the ceiling were sagging. This is likely to be due to
building materials coming loose and requiring reattachm ent. There
are also gaps between window and brick and brick and eave sheets,
which are all signs of movement;
the settlement in the slab of the building has pulled down the timber
frame and consequently the roof structure;
the property has settled due to leakages from the underground
stormwat er pipe on the side of building and has caused significant
settlement on the front right - hand side of the building;
the defective plumbing needs to be fixed; and
the front side of the building also needs to be underpin ned and lifted
as much as possible to stop further sinking and to close off the gaps
between building materials.
Insurer’s expert report –
SP (plumber)
there is evidence of structural damage throughout the property. It
therefore ins pected stormwater, sewer and water lines to see if there
were any leaking pipes;
a CCTV inspection camera was used at various points in the
stormwat er pipe. This showed four major areas of concern:
the connection of the downpipe to the storm water at the rear right
corner o f the property is incorrect. As a result, a large amount of
water would be leaking straight out of this connection and going
underground;
the stormwater pipe is brok en just after the downpipe at the front right
corner of the house. Water would be leaking underground in this
Determination | Case number: 883896 Page 8 of 9
Record Key points
area as well;
there is a broken junction at the front of the house where the right
side meets the left side. Water would also be leaking from the
junction underground;
there is root intrusion and a blockage in the stormwater line on the
front left side of the hous e. This would cause the stormwater the
back up and possibly overflow from the storm wat er pit at the rear left
corner of the house;
there are no issues with the sewer line. The water line could not be
tested due to a faulty stop - tab valve which needs to be replaced;
due to the four areas of concern, water would be leaking underground
which in turn could cause ground movement and possible damage to
the property; and
an engineer should be appointed to furt her assess these issu es.
Insurer’s expert report
and supplementary report
– IL (structural engineer)
the ceiling lining of the front verandah was showing signs of failing
and sagging;
there was slight vertical cracking on the western elevation of the
dwelling;
storm water drain pipes were installed at the rear southern elevation
at ground level;
the pergola and roof systems drain int o the same eaves guttering,
creating a situation where the guttering runs directly above an indoor
space. T here is extensive mould to the eave s lining and evidence of
water saturating the wailing plate;
the guttering at the front north elevation is leaking at the mitre joint;
the majority of the internal damage to the dwelling consists of ceiling
cracking, cornice crushing and wall plaster damag e generally at the
top of door and window openings;
real estate listings confirm that the patch repairs in ceiling plaster
existed prior to the complainant purchasing the property in 2013.
There is also evidence of water damage to the lounge room carpet;
an inspection of the roof cavity showed no defects or damage to the
timber roof trusses or note connections. There was also no evidence
of water damage to the plaster roof sheets;
the internal damage to the dwelling has not been caused by an
insured event such as a storm or leak. Rather, it has been caused by
truss creep and incorrect installation of back blocking over the joints
of the ceiling plaster;
when structures are subject to an escape of water (such as a leaking
storm water pipe), the damage and movement is generally not
uniform and occurs local to the escape of water. There is no
evidence of exterior wall rotation or damage local to the stormwater
drain defects. Therefore, it does not consider an escape of liquid has
caused the internal damage to the property. The floor level survey
also does not show any localised heaving or contouring variations
that you would expect if the leaks had been the dominant cause of
the movement ;
Determination | Case number: 883896 Page 9 of 9
Record Key points
the negligible to slight cracking to the wall plaster at the top of window
and door openings has been caused by natural seasonal movement
of the moderately reactive class M soils;
non - load - bearing walls should be kept a minimum of 10mm below the
underside of the bottom chord to prevent the chord of the roof truss
bearing o n the non - load bearing walls, as the truss will naturally
deflect over a long period of time due to a proc ess of creep. Creep is
the increase in deflection, with time, without an increase in load. This
characteristic is significant with timber and also t il ed roof dwellings
are more susceptible to creep due to the significantly high loading of
a tiled roof on the roof trusses exacerbating the natural creep of the
timber ;
the plaster ceiling at the property is directly affixed to the bottom
chord of the truss es and hence any deflection in the trusses will be
transferred through the plaster sheeting;
further, as the cornices are directly fixed to the plaster ceiling walls,
these same forces are transferred through the bottom chord of the
truss and ceiling batte ns into ceiling plaster and cornices which
inevit ably results in crushing of the b rittle plaster finishes;
b ack - blocking is a method for reinforcing plasterboard joints to
minimise joint cracking and peaking ;
the back - blocking installation at the dwelling is completely insufficient
and provides absolut ely no restraint or support to the plasterboard
sheets. The back - blocking sections are sporadically located and do
no t extend along the entire joint;
the eaves guttering servicing the two separate roof systems , dwelling
and pergola, is completely inadequate in design, sizing and is unable
to capture and re - direct stormwater liquids to the legal point of
discharge ;
the non - compliant and undersized eaves gutters, and there being no
rainhead, sump or other overflo w provision, has caused the extensive
mould and water staining. This also confirms water entry inside the
building;
the storm water system does not comply with Australian Standards.
The system should be upgraded or else water ingress will continue to
occ ur;
in its opinion, the long term, ongoing natural seasonal movement of
the moderat ely reactive founding soils evident by the previous repairs
completed to the dwelling dating back to at least 2013.
Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.