Home / Suncorp Group / Determination 883896

Determination 883896

Claim declined for property damage allegedly caused by stormwater overflow and leaking stormwater pipe

FirmSuncorp Group
Decided2023-02-10
ProductGeneral Insurance · Landlord
OutcomeFor the firm
Amount awarded—
Non-financial loss—
Amount claimed—
SourceAFCA PDF

Summary

The complainant lodged a landlord insurance claim in March 2021 for storm and stormwater leak damage to his property. AFCA decided the insurer was entitled to decline the claim, finding the damage was mainly caused by long-term soil movement, truss creep and inadequate back-blocking.

The complainant failed to establish on the balance of probabilities that the proximate cause of the damage was an insured storm or escape of liquid event, and the ground movement and wear exclusions applied.

Issues

Subjects and remedies

home or building damageno remedy

Related

All Suncorp Group determinations · Find similar determinations

Text of the determination

Determination Case number 883896 Financial firm AAI Limited Determination | Case number: 883896 Page 1 of 9 Case number: 883896 10 February 2023 1 Determination overview 1.1 Complaint The complainant holds a landlord insurance policy with the insurer. On 21 March 2021, the complainant lodged a claim for damage to his property caused by stormwater overflowing from the gutters and a leaking stormwater pipe underground. The insurer declined the claim and said the damage is not consistent with an insured event under the policy. It says the complainant has not established a valid claim under the policy. Further, it says the damage is due to ground movement. The complainant disagrees with the insurer’s decision and seeks that the damage be covered. 1.2 Issues and key findings Is the insurer entitled to decline the claim? Yes. The complainant has not established that the damage to the property was caused by an insured event. On balance, the proximate cause of the damage is differential movement which has occurred gradually due to long term seasonal movement of the moderately reactive soil, truss creep and inadequate back-blocking. Accordingly, the insurer is entitled to decline the claim. Why is the outcome fair? The complainant has not established a valid claim under the policy. Therefore, the insurer is entitled to decline the claim. It would not be fair, in the circumstances, to require the insurer to cover the claim. 1.3 Determination This determination is in favour of the insurer. The insurer is entitled to decline the claim. It is not required to take any further action in relation to the claim or the complaint. Determination | Case number: 883896 Page 2 of 9 2 Reasons for determination 2.1 Is the insurer entitled to decline the claim? Yes. The complainant has not established that the damage to the property was caused by an insured event. On balance, the proximate cause of the damage is differential movement which has occurred gradually due to long term seasonal movement of the moderately reactive soil, truss creep and inadequate back-blocking. Accordingly, the insurer is entitled to decline the claim. Onus on complainant to establish valid claim The initial onus is with the complainant to establish, on the balance of probabilities (that it is more likely than not), that the loss or damage claimed falls within the terms of the policy. This is known as a valid (or prima facie ) claim. Once the complainant has established a valid claim, the onus shifts to the insurer to establish, on balance, the application of a policy exclusion or that it is otherwise entitled to decline the claim under the policy. Policy covers insured events subject to exclusions The insurer’s policy consists of the policy schedule and product disclosure statement (PDS). It is not in dispute the insurer provided the policy documents to the complainant. The policy is an ‘insured events’ policy. This means not all loss and damage is automatically covered. Rather, only loss or damage caused by one or more of the insured events, and not subject to exclusions, is covered. The insured events are set out in the PDS and include storm and escape of liquid events. However, the PDS states that cover for storm and/or escape of liquid does not include: - loss or damage caused by erosion, vibration, subsidence, landslip, landslide, mudslide, collapse, shrinkage or any other earth movement, but we will cover loss or damage caused by a landslide or subsidence proved to have occurred within 72 hours of, and directly because of, a storm and not because of erosion, structural fault or design fault; Cover for an escape of liquid event also excludes: - wear, tear and gradual deterioration or loss or damage by the gradual process of liquid leaking, splashing, dripping or overflowing; The policy also generally excludes cover for loss or damage to, or caused by, connected with or arising from: Ground movement erosion, vibration, subsidence, landslip, landslide, mudslide, collapse, shrinkage or any other earth movement, but we will cover landslide or subsidence that is specifically covered under the following insured events: Determination | Case number: 883896 Page 3 of 9 - ‘Storm’ page 46;… Complainant says damage caused by escape of liquid and storm The complainant says:  after the claim was lodged, the stormwater drain repairs were completed by a plumber, BSP, to parts of the pipe at the rear right corner of the dwelling, front right corner of the dwelling and the junction connection at the front of the property. Following this, a certificate of compliance was issued on 22 July 2021;  it obtained a report from a building inspector, OBI, who confirmed the damage to the property is as a result of settlement caused by leaks from the stormwater pipe. OBI says: > there is a gap between the brick wall and lintel on the north-west elevation which is consistent with significant settlement in the slab in the front room; > the settlement of the slab has pulled down the timber frame of the wall and, consequently, the roof structure; > excessive movements in the timber frame has caused detachment of plasterboards and cracks on the walls and ceilings; > there is no sign of damage to floor tiles which is likely because settlement has not extended to the middle of the building where the kitchen and living room is located; > sections of the ceiling are sagging. This is likely to be due to building materials coming loose and requiring reattachment. There are also gaps between window and brick and brick and eave sheets, which are all signs of movement; and > underpinning of the slab can stabilise the footings and the damage to the plasterboard on the ceilings and walls can be fixed after this occurs. Insurer provided reports commenting on the cause of damage The insurer engaged a plumber, SP, who says:  it identified four major areas of concern in relation to the stormwater pipe;  there is evidence of structural damage throughout the property;  due to the four areas of concern, water is leaking underground which in turn could be causing ground movement and possible damage to the property; and  it recommends an engineer be appointed to further assess these issues. The insurer also appointed an engineer, IL, to report on the cause of the damage. It says:  the majority of the internal damage to the dwelling consists of ceiling cracking, cornice crushing and wall plaster damage;  the issues with the storm water pipe and the escape of liquid have not caused the internal damage to the property. This is because if the escape of liquid was the cause of the damage, it would expect the movement to be localised. It would also expect to see exterior wall rotation. There is no evidence of either rotation or localised movement. The floor level survey also does not show localised heaving or contouring to suggest the escape of liquid was the cause of the movement;  further, an inspection of the roof cavity showed no defects or damage to the timber roof trusses or node connections. There was also no evidence of water damage to the plaster roof sheets;  the internal damage to the dwelling has been caused by truss creep (the plaster ceiling is directly affixed to the bottom chord and hence any deflection in the trusses will be transferred through the plaster sheeting) and the incorrect installation of back blocking over the joints of the ceiling plaster (the cornices are directly fixed to the plaster ceiling Determination | Case number: 883896 Page 4 of 9 walls, these same forces are transferred through the truss and ceiling battens into ceiling plaster and cornices which results in crushing of the brittle plaster finishes);  the back-blocking installation at the dwelling is completely insufficient and provides absolutely no restraint or support to the plasterboard sheets. The back-blocking sections are sporadically located and do not extend along the entire joint;  the negligible to slight cracking to the wall plaster at the top of window and door openings has been caused by natural seasonal movement of the moderately reactive class M soils;  real estate listings confirm that the patch repairs to the ceiling plaster existed prior to the complainant purchasing the property in 2013. There is also evidence of water damage to the lounge room carpet;  the non-compliant and undersized eaves gutters, and there being no rainhead, sump or other overflow provision, has caused the extensive mould and water staining. This also confirms water entry inside the building;  the storm water system does not comply with Australian Standards. The system should be upgraded or else water ingress will continue to occur; and  the damage to the property has been caused by long term, ongoing natural seasonal movement of the moderately reactive founding soils, evident by the previous repairs completed dating back to at least 2013. Proximate cause of the damage must be established The complainant needs to show the proximate cause of the damage being claimed is, on balance, the storm and/or escape of liquid event, which is not otherwise excluded. The proximate cause of a loss is the dominant, effective or operative cause. It does not have to be the first, the last or the sole cause. This is a question of fact depending on the circumstances. If there are several causes, each needs to be examined for qualities of reality, predominance and efficiency to identify the proximate cause. For example, if one cause would have caused the loss in any case, and the other one would not have done so without the first, then the first is the proximate cause. Available information does not show damage due to storm Having reviewed all the available information, I am not satisfied, on balance, that the complainant has established that the property damage has been caused by a storm or an escape of liquid event. I accept that the complainant has provided evidence regarding the damage to the stormwater pipe and the escape of liquid. However, I am not satisfied that it has established that these defects and/or the escape of liquid caused the damage to the property. I note in this regard that the cracking is throughout the property and is not localised to the areas of defective or leaking stormwater pipe. I also accept that the floor level survey does not show any significant differential either generally or at the location of the stormwater pipe defects. The complainan t’s evidence also does not address the soil classification of the site nor the movement that can occur as a result. I am satisfied that IL is sufficiently qualified to assess and comment on the cause of the damage at the property. In this regard, I am persuaded by its reasoning that the cause of the damage is long term ongoing natural seasonal movement of the moderately reactive founding soils. I am satisfied that the movement, along with the truss creep and the inadequate back- blocking is the proximate cause of the damage. Determination | Case number: 883896 Page 5 of 9 I note also that the advertising images provided suggest the ceiling cracking has been occurring since at least 2013 and that patch repairs have been conducted since that time. Given there is no clear connection between the areas of damage and the location of the defective pipe, I am not satisfied the complainant has established the claimed damage is a result of the defects in the stormwater pipe. I consider, on balance, the proximate cause of the damage is a result of the long term ongoing movement of the soil, truss creep and inadequate back blocking. Accordingly, the insurer is entitled to decline the claim. It is not required to take any further action in relation to the claim or the complaint. 2.2 Why is the outcome fair? The complainant has not established a valid claim under the policy. Therefore, the insurer is entitled to decline the claim. It would not be fair, in the circumstances, to require the insurer to cover the claim. Determination | Case number: 883896 Page 6 of 9 3 Supporting information 3.1 The AFCA process AFCA’s approach is based on fairness AFCA has determined this complaint based on what is fair in all the circumstances, having regard to:  the legal principles  applicable industry codes or guidance  good industry practice  previous decisions of AFCA or its predecessor schemes (which are not binding). The respective parties have completed a full exchange of the relevant information, and each party has had the opportunity to address any issues raised. We have reviewed and considered all of the information the parties have provided. While the parties have raised a number of issues in their submissions, we have restricted this determination to the issues that are relevant to the outcome. We assess complaints on available information and circumstances AFCA is not a court of law. We do not have the power to take or test evidence on oath, or to require third parties to give evidence. When we assess complaints, we consider:  available documents  the recollections of the parties  all relevant circumstances. We give more weight to documents created at the time the events occurred. If there are no relevant documents, we will decide what most likely occurred based on the available information. If there are conflicting recollections and these are evenly weighted, we may find that a claim cannot be established. Determination | Case number: 883896 Page 7 of 9 3.2 Summary of reports provided by the parties Record Key points Complainant’s expert report - BSP ( plumber )  tree roots had been located entering the broken section of stormwater pipe under the garage;  the issue is located below the conc rete slab;  the drain in this area is holding water in several areas;  the tree roots in the drain is causing water restriction in the pipe; and  it recommends cutting out and replacing the broken and tree root section s of pipe, installi ng a concrete pit, connecting the storm water drain to the pit and reinstating the concrete slab around the new pit. Complainant’s expert report - OBI ( building inspector )  there is a major structural defect on the north - west elevation, comprising the displacement of the wall from its original location in several locations. There is also movement in the brick wall leaving a gap between brick and lintel. This is consistent with significant settlement in the slab in the front room;  various damage and de fects were observed internally including unleveling of floors and damage to plasterboard, ceilings, walls and doors. There was no sign of damage to floor tiles which is likely because settlement has not extended to the middle of the building where the kit chen and living room is located;  the internal damage is consistent with the slab having tilted toward the front part of the building;  sections of the ceiling were sagging. This is likely to be due to building materials coming loose and requiring reattachm ent. There are also gaps between window and brick and brick and eave sheets, which are all signs of movement;  the settlement in the slab of the building has pulled down the timber frame and consequently the roof structure;  the property has settled due to leakages from the underground stormwat er pipe on the side of building and has caused significant settlement on the front right - hand side of the building;  the defective plumbing needs to be fixed; and  the front side of the building also needs to be underpin ned and lifted as much as possible to stop further sinking and to close off the gaps between building materials. Insurer’s expert report – SP (plumber)  there is evidence of structural damage throughout the property. It therefore ins pected stormwater, sewer and water lines to see if there were any leaking pipes;  a CCTV inspection camera was used at various points in the stormwat er pipe. This showed four major areas of concern:  the connection of the downpipe to the storm water at the rear right corner o f the property is incorrect. As a result, a large amount of water would be leaking straight out of this connection and going underground;  the stormwater pipe is brok en just after the downpipe at the front right corner of the house. Water would be leaking underground in this Determination | Case number: 883896 Page 8 of 9 Record Key points area as well;  there is a broken junction at the front of the house where the right side meets the left side. Water would also be leaking from the junction underground;  there is root intrusion and a blockage in the stormwater line on the front left side of the hous e. This would cause the stormwater the back up and possibly overflow from the storm wat er pit at the rear left corner of the house;  there are no issues with the sewer line. The water line could not be tested due to a faulty stop - tab valve which needs to be replaced;  due to the four areas of concern, water would be leaking underground which in turn could cause ground movement and possible damage to the property; and  an engineer should be appointed to furt her assess these issu es. Insurer’s expert report and supplementary report – IL (structural engineer)  the ceiling lining of the front verandah was showing signs of failing and sagging;  there was slight vertical cracking on the western elevation of the dwelling;  storm water drain pipes were installed at the rear southern elevation at ground level;  the pergola and roof systems drain int o the same eaves guttering, creating a situation where the guttering runs directly above an indoor space. T here is extensive mould to the eave s lining and evidence of water saturating the wailing plate;  the guttering at the front north elevation is leaking at the mitre joint;  the majority of the internal damage to the dwelling consists of ceiling cracking, cornice crushing and wall plaster damag e generally at the top of door and window openings;  real estate listings confirm that the patch repairs in ceiling plaster existed prior to the complainant purchasing the property in 2013. There is also evidence of water damage to the lounge room carpet;  an inspection of the roof cavity showed no defects or damage to the timber roof trusses or note connections. There was also no evidence of water damage to the plaster roof sheets;  the internal damage to the dwelling has not been caused by an insured event such as a storm or leak. Rather, it has been caused by truss creep and incorrect installation of back blocking over the joints of the ceiling plaster;  when structures are subject to an escape of water (such as a leaking storm water pipe), the damage and movement is generally not uniform and occurs local to the escape of water. There is no evidence of exterior wall rotation or damage local to the stormwater drain defects. Therefore, it does not consider an escape of liquid has caused the internal damage to the property. The floor level survey also does not show any localised heaving or contouring variations that you would expect if the leaks had been the dominant cause of the movement ; Determination | Case number: 883896 Page 9 of 9 Record Key points  the negligible to slight cracking to the wall plaster at the top of window and door openings has been caused by natural seasonal movement of the moderately reactive class M soils;  non - load - bearing walls should be kept a minimum of 10mm below the underside of the bottom chord to prevent the chord of the roof truss bearing o n the non - load bearing walls, as the truss will naturally deflect over a long period of time due to a proc ess of creep. Creep is the increase in deflection, with time, without an increase in load. This characteristic is significant with timber and also t il ed roof dwellings are more susceptible to creep due to the significantly high loading of a tiled roof on the roof trusses exacerbating the natural creep of the timber ;  the plaster ceiling at the property is directly affixed to the bottom chord of the truss es and hence any deflection in the trusses will be transferred through the plaster sheeting;  further, as the cornices are directly fixed to the plaster ceiling walls, these same forces are transferred through the bottom chord of the truss and ceiling batte ns into ceiling plaster and cornices which inevit ably results in crushing of the b rittle plaster finishes;  b ack - blocking is a method for reinforcing plasterboard joints to minimise joint cracking and peaking ;  the back - blocking installation at the dwelling is completely insufficient and provides absolut ely no restraint or support to the plasterboard sheets. The back - blocking sections are sporadically located and do no t extend along the entire joint;  the eaves guttering servicing the two separate roof systems , dwelling and pergola, is completely inadequate in design, sizing and is unable to capture and re - direct stormwater liquids to the legal point of discharge ;  the non - compliant and undersized eaves gutters, and there being no rainhead, sump or other overflo w provision, has caused the extensive mould and water staining. This also confirms water entry inside the building;  the storm water system does not comply with Australian Standards. The system should be upgraded or else water ingress will continue to occ ur;  in its opinion, the long term, ongoing natural seasonal movement of the moderat ely reactive founding soils evident by the previous repairs completed to the dwelling dating back to at least 2013.

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.