Claim declined for frost fan failure attributed to machinery breakdown; AFCA found wind event caused damage
Text of the determination
Determination
Case number 883196
Financial firm Allianz Australia Insurance Limited
Determination | Case number: 883196 Page 2 of 8
Case number: 883196 24 November 2022
1 Determination overview
1.1 Complaint
The complainant holds a farm park insurance policy with the financial firm (insurer) and
lodged a claim following the failure of a frost fan at a vineyard.
The insurer declined the claim because it says the damage is not due to an insured event
covered by the policy. Rather, it says the damage is due to machinery breakdown, which is
excluded.
The complainant is a company, which was represented during the course of the dispute.
References throughout the determination to the complainant include reference to the
representative.
1.2 Issues and key findings
Is the insurer entitled to decline the claim?
No. The information shows the damage, on balance, is due to a wind event, which led to the
frost fan’s failure. The complainant has established a valid claim for this damage and the
insurer has not satisfied its onus to show the damage is excluded under the policy.
Why is the outcome fair?
As the complainant has established an insured event caused the damage and the insurer has
not established the damage is excluded under the policy, it is fair for the insurer to accept the
claim.
1.3 Determination
This determination is in favour of the complainant.
The insurer is to pay the complainant $34,325.50 for the frost fan. Interest is payable on this
amount from the date of the invoice until the date of payment, in accordance with section 57
of the Insurance Contracts Act 1984 (the Act).
It is also fair for the insurer to reimburse the complainant $1,782 for the cost of his
engineering report. Interest is payable on this amount from the date of the invoice until the
date of payment in accordance with section 57 of the Act.
Determination | Case number: 883196 Page 3 of 8
2 Reasons for determination
2.1 Is the insurer entitled to decline the claim?
Policy covers storm damage that is not otherwise excluded
The initial onus is with the complainant to establish on the balance of probabilities (that is
more likely than not) that the loss or damage claimed falls within the terms of the policy. This
is known as a valid (or prima facie ) claim.
Once the complainant has established a valid claim, the onus shifts to the insurer to establish,
on balance, the application of a policy exclusion or that it is otherwise entitled to decline the
claim under the policy.
The policy is an ‘insured events’ policy. This means not all loss and damage is automatically
covered. Rather, only loss or damage caused by one or more of the insured events and not
subject to exclusions, is covered.
The insured events are set out in the product disclosure statement (PDS) and include storm ,
rainwater or wind.
Complainant says high winds caused damage to the frost fan
The complainant says:
metal fatigue is not a cause of damage, it is the result of an event
the event which initiated the metal fatigue was most probably a high wind event, which is
the proximate cause, and this is supported by both his expert reports
the insurer’s expert is silent on the cause of the initiation of the fatigue crackin g
the insurer’s expert did not conduct a more thorough investigation of wind activity in the
area prior to the day of the failure, despite admitting the failure was not instantaneous
the reports show the failure of the fan blade was not a design fault or normal wear and tear
when the frost fan was activated at 5:30 am on 27 August, it was the first time it had been
operated since the unusually high and damaging wind activity of the preceding six weeks
the fan had been functioning normally prior to the stro ng wind events and was in good
condition .
The complainant provided information to show it had recently serviced the frost fan prior to
the event occurring.
The complainant replaced the frost fan and provided the invoice for $34,325.50. The
complainant also provided an invoice for the engineering report for $1,782.
Complainant’s reports state high winds caused the damage
The complainant provided a report from a fan company (AF) dated 30 August 2021. AF stated
it inspected the unit where ‘severe mechanical fault was noticed’. AF stated:
Damage like this is usually caused by excessive external forces (e.g., Unusually
high, and fluctuating wind speeds while the machines Are running)
The overall condition of this machine is good as it has been regularly serviced by
[AF] and was in good operating condition.
In conclusion, the machine has experienced a mechanical failure which has
transmitted unexpected stress/shock loads to most of the driveline components.
Determination | Case number: 883196 Page 4 of 8
The damaged noted on the 27/08/2021 is outside of the normal wear and tear
operation of a Frost fan. (sic)
The complainant provided a report from a mechanical engineer (IN) dated 21 February 2022.
IN stated:
the frost fan blades are made from an extruded aluminium aerofoil profile
aluminium fatigue is accumulative and can occur if the part is subjected to high repetition
low stress loads and/or low repetition high stress loads
typically, fatigue is initiated by some high stress event or material inclusion which creates a
material weakness and a site of crack initiation, and following crack initiation, subsequent
load cycles do not need to be as high as the high stress event, to propagate the crack
further
fatigue is evident in the failed fan blade profile
there are marks in the profile consistent with fatigue failure as the accumulated cracking
occurs in cycles, with the fatigue crack growing through the material
there are a series of striations originating from near the blade bolt locations
the crack propagation occurred until the blade reached a point of critical stress and
subsequent sudden failure, with the evidence of sudden failure shown by the rough
sudden fracture zone
the discolouration of the striations on the failed fan blade indicates there was some time
between the initial cracking and secondary cracking resulting in final failure
high wind loads have a risk of damage (high stress) that may head to fatigue cracking
prior to the failure of the front fan there was a period where peak wind speeds reached up
to 94km/h on 16 July 2021, and extended periods where wind speeds exceeded 50km/h,
therefore it cannot be ruled out that a high wind event may have impacted the fan blade in
the months leading up to the failure
other fan blades also show cracking, with discolouration suggesting corrosion was evident
prior to fan failure
as additional fan blades show long term cracking, it is probable the catastrophic failure of
the fan was caused by a loading event rather than material inclusions
it is foreseeable that a high load event could have occurred in the months prior, initiating
fatigue cracking prior to the catastrophic failure, which is supported by the striation and
oxidisation profile of the failed fan blade and discolouration of the other blade crack
surface.
IN provided a further email dated 10 May 2022, which states:
when considering the cause of the fan failure, it is counterproductive to consider fatigue
initiation and the catastrophic failure as separate occurrences
the fatigue event was initiated when the initial damage was caused (crack initiation) an d
finished when the fan failed (crack propagation until failure)
when reviewing any fatigue failure, in particular allows, the full operating life of the item
and any significant load events are relevant
fatigue initiation is caused when stress, typically at the surface of a component, exceeds
that of the fatigue limit, initiating a crack
crack initiation consumes a significant portion of the fatigue life of a component
the cause of high stress in this circumstance is probable to be a high wind event, therefore
it should be considered that the cracking that led to catastrophic failure of the fan, began
with crack initiation, due to a probable high load wind event.
The complainant provided a further report from AF dated 18 April 2022. AF stated the primary
cause of aluminium blade fracture is due to the operation of wind. AF stated:
Determination | Case number: 883196 Page 5 of 8
it suspects the machine failure is due to an accumulation of operating hours in the wind, as
this was the first run for this machine for the 2021 frost season when it suffered
catastrophic failure
the overall general condition of the machine is good as it has been serviced on a regular
basis and has relatively low running hours of 615.5 for its age.
Insurer states the damage is due to metal fatigue
The insurer provided a report from a loss adjuster (YD) dated 8 September 2021. YD stated:
the failure occurred during the early morning of 27 August 2021
the maximum wind gust on that day was 35km/h, which is not excessive
clearly one of the fan blades broke and the rotational speed of the fan was sufficient to
project the blade 100 plus metres across the vineyard
the loss of one blade would cause severe imbalance to the gearbox and drive shafts and
as a consequence, not only did the gearbox casing fracture allowing the remains of the
other three blades and gearbox output shaft to drop to the ground, but caused significant
stresses to the drive shafts down the tower, and to the lower gearbox
there are two half-moon shapes that appear to be a series of striations, and are markings
indicative of what it believes to be fatigue cracking
it ‘is not within our capability to determine over the period of time that fatigue cracking has
occurred but it would not be instantaneous’
if the fatigue cracking is the case, then the residual sections of the fan blade would have
reduced strength and would eventually give way
it ‘suspects’ this is what has occurred, which resulted in the blade separating and being
projected across the vineyard
a second blade had bent at the end of the splice plate and a severe crack was visible
it is confident this crack existed prior to this failure, which supports its view that fatigue
cracking has occurred in the failed blade
the frost fans are designed to work in an outdoor setting but have the facility to auto
shutdown in the event of high winds
it has difficulty believing that strong winds caused the blade to break and are of the view
that this is a consequence of fatigue fracture over a period of time.
The insurer says the proximate cause of damage to the frost fan was metal fatigue, not wind
gusts. It says the policy only covers machinery breakdown for two submersible pumps noted
in the policy schedule, not the frost fan. It says the cause of damage was fatigue cracks
growing over an extended period, culminating in catastrophic mechanical failure.
Cause of damage, on balance, is the wind event
IN accepts there is fatigue. However, its report provides detailed reasons as to why an event
such as high winds is the likely cause of this fatigue. This is because it states fatigue is
initiated by a high stress event which creates a material weakness and a site of crack
initiation. IN stated the fatigue event was initiated when the initial damage was caused and
finished when the fan failed. IN also stated it is probable that a high wind event caused the
initial damage, which ultimately led to the damage.
While YD states it has difficulty believing strong winds caused the blade to break, it does not
elaborate further on why it holds this opinion. There are limited details in YD’s re port and a
lack of explanation for how it considers fatigue cracking occurred over time if not for an initial
event, such as high winds. Based on AF’s reports, the information shows the frost fan was in
good condition and there was no evidence of general wear and tear. Given AF regularly
services the frost fan, I consider its opinion on the condition of the frost fan to be persuasive.
Determination | Case number: 883196 Page 6 of 8
Based on this information, it is difficult to accept a finding that the frost fan failed due to
fatigue failure over time. Based on the other available information, I consider it more probable
than not that an initial high wind event caused the initial damage, which ultimately led to the
failure of the front fan.
While the insurer says the complainant must show a specific insured event caused the
damage, the complainant provided information to show there were significant wind events in
the month prior to the failure. IN’s report links these wind events with the most probable
cause. I consider this information persuasive. I consider the complainant has established, on
balance, a wind event caused the damage that ultimately led to the frost fan’s failure.
Fair for the insurer to accept the claim
The insurer’s policy consists of the policy schedule and PDS. It is not in dispute the insurer
provided the policy documents to the complainant. The insurer is therefore entitled to rely on
those terms when assessing any claim made against the policy.
The policy covers several insured events, including storm, rainwater and wind. As outlined
above, I consider the complainant has established, on balance, wind caused damage to the
frost fan that ultimately led to its failure. There is nothing to indicate this damage did not occur
whilst insured with the insurer. The complainant has therefore established a valid claim and
the onus shifts to the insurer to show it is entitled to decline the claim.
The insurer refers to the following exclusions in the PDS:
1. We will not pay under this Section Two for:
…
b) Breakdown Cost to repair or replace Farming Property due to:
(i) mechanical, hydraulic, electrical or electronic breakdown, malfunction,
breakage or failure unless caused by an insured occurrence;
…
5. We will not pay for loss or damage caused by or in connection with or arising
from or occassioned through:
a) rust, corrosion, algae, mould or mildew unless caused by a direct result of an
insured event;
b) erosion, subsidence, earth movement or collapse resulting therefrom.
However, We will cover You for loss or damage when it is a direct result of an
insured event and occurs within 72 hours of an insured event;
c) mechanical, hydraulic, electrical or electronic breakdown, failure, malfunction or
derangement of any machine or electrical or electronic device or temperature
controlling equipment.
I do not consider the insurer has satisfied its onus to show these exclusions apply. This is
because whilst the frost fan ultimately failed, I accept this was due to the wind event, which is
an insured occurrence, not one of the excluded events such as corrosion or mechanical
failure. I do not consider the intention of the policy is to exclude damage caused by an
insured event such as wind.
As the insurer has not established the damage is excluded, it is fair for the insurer to accept
the claim. The insurer is to pay the complainant $34,325.50 for the frost fan. Interest is
payable on this amount from the date of the invoice until the date of payment, in accordance
with section 57 of the Act.
Determination | Case number: 883196 Page 7 of 8
Under the AFCA Rules, AFCA can determine an insurer contribute up to $5,000 to
professional costs incurred by the complainant during the complaint.
As the complainant’s report assisted in the resolution of the complaint, it is also fair for the
insurer to reimburse the complainant $1,782 for the cost of his engineering report. Interest is
payable on this amount from the date of the invoice until the date of payment in accordance
with section 57 of the Act.
Determination | Case number: 883196 Page 8 of 8
3 Supporting information
3.1 The AFCA process
AFCA’s approach is based on fairness
AFCA has determined this complaint based on what is fair in all the circumstances, having
regard to:
the legal principles
applicable industry codes or guidance
good industry practice
previous decisions of AFCA or its predecessor schemes (which are not binding).
The respective parties have completed a full exchange of the relevant information, and each
party has had the opportunity to address any issues raised. We have reviewed and
considered all of the information the parties have provided.
While the parties have raised a number of issues in their submissions, we have restricted this
determination to the issues that are relevant to the outcome.
We assess complaints on available information and circumstances
AFCA is not a court of law. We do not have the power to take or test evidence on oath, or to
require third parties to give evidence.
When we assess complaints, we consider:
available documents
the recollections of the parties
all relevant circumstances.
We give more weight to documents created at the time the events occurred. If there are no
relevant documents, we will decide what most likely occurred based on the available
information.
If there are conflicting recollections and these are evenly weighted, we may find that a claim
cannot be established.