Home / Hollard / Determination 882504
Determination 882504
Denial of claim for cracking and movement damage on the basis of excluded ground movement, and claim handling
Summary
The complainant claimed for cracking and movement damage to his home, attributed to leaking pipes or the earthquake. The insurer denied it as excluded ground movement, and AFCA found in favour of the insurer and declined non-financial loss compensation.
Expert evidence showed it was more likely than not that the dominant cause of damage was long-term ground movement, which is excluded, and the insurer did not mishandle the claim.
Issues
- Claim denial primary · not upheld“The insurer has on balance established that the proximate cause of the damage claimed was excluded ground movement.”
- Poor claim handling secondary · not upheld“The information provided does not show that the insurer delayed or otherwise mishandled the claim.”
Subjects and remedies
home or building damagenatural disasterno remedy
Related
Text of the determination
Determination
Case number 882504
Financial firm Hollard Insurance Partners Limited
Determination | Case number: 882504 Page 1 of 6
Case number: 882504 18 May 2023
1 Determination overview
1.1 Complaint
The complainant and his wife hold home building and contents insurance issued by the
financial firm (insurer). On 31 October 2021, the complainant lodged a claim for cracking and
movement damage. He said the damage had been caused by leaking pipework, possibly due
to the Victorian earthquake on 21 September 2021.
The insurer has denied the claim. It says the proximate cause of damage was not escape of
liquid (EOL) from the leaking pipes, or the earthquake. Rather, the damage had been caused
by unrelated long term ground movement which is excluded under the policy terms.
The complainant maintains that the claim should be accepted. He says that a stormwater pipe
was leaking directly under the foundation footings, so the damage was caused by EOL. He is
also dissatisfied with the insurer’s claim handling.
1.2 Issues and key findings
Is the insurer entitled to deny the claim?
Yes. The insurer has on balance established that the proximate cause of the damage claimed
was excluded ground movement. Proximate cause is the dominant, efficient or operative
cause of the loss. It is not required to be last in time or the sole cause.
Is non-financial loss compensation payable?
No. The information provided does not show that the insurer delayed or otherwise mishandled
the claim.
Why is the outcome fair?
The insurer has shown that the operative cause of damage was excluded ground movement.
It would not be fair to require the insurer to cover the claim when the policy does not respond.
It would also be unfair to expect the insurer to pay non-financial loss compensation when it
did not mishandle the claim.
1.3 Determination
This determination is in favour of the insurer.
The insurer is entitled to deny the claim. it is not required to take any further action.
Determination | Case number: 882504 Page 2 of 6
2 Reasons for determination
The parties provided numerous submissions to AFCA. While this determination does not refer
to them all, I have taken each submission into account in reaching my decision.
2.1 Is the insurer entitled to deny the claim?
Yes. The insurer has on balance established that the proximate (operative or dominant)
cause of the damage claimed was excluded ground movement. Proximate cause is the
dominant, efficient or operative cause of the loss. It is not required to be last in time or the
sole cause.
Complainant must show a claimable loss under the policy
The complainant is required to show, on the balance of probabilities (that it is more likely than
not), that he suffered a claimable loss under the policy. This means he must show the loss
was caused by a risk for which he is insured.
Subject to the terms and conditions set out in the product disclosure statement (PDS), the
complainant’s policy covers damage to the insured property caused by a listed insured event.
Those events include ‘Earthquake’ and ‘Sudden escape of liquid’.
On 31 October 2021, the complainant lodged a claim with the insurer. He said that after
recent heavy rain and the Victorian earthquake, he had noticed movement damage affecting
his home. His plumber had identified that a stormwater drain had become dislodged, resulting
in EOL underground. The complainant suggested the earthquake may have been the cause.
Once the complainant proves the existence of a claimable loss, the insurer is liable for the
loss unless it shows an exclusion or limiting condition applies. The insurer has the onus of
proving on the balance of probabilities the application of the exclusion or condition.
Insurer says the damage is due to excluded ground movement
The insurer appointed plumber SR and builder DW to assist it with claim assessment.
SR inspected the property on 2 November 2021 and reported that:
the rear downpipe towards the property’s centre had a break in the adapting boot, but that
was not contributing to the dropping of the home at the back right hand corner
after pressure testing the water to the home, the subfloor was seen to be largely dry
the back right hand corner downpipe had a significant break before the discharge point
and was very likely contributing to the home’s movement
the sewer/waste from the kitchen had a broken junction at the connection point
the sewer from the toilet had a slight sag, which was a further ground movement indicator.
DW inspected the property the following day. It concluded that the EOL had been occurring
gradually over a 12 month period. It said this had led to gradual sag in the sewer lines.
According to DW, the damage to the property ‘has occurred as a result of ground movement
which, in turn, has caused the pipework to break and fail’.
The insurer’s appointed engineer , SE, inspected the property on 7 January 2022 and advised:
the pre-existing movement damage and repair work were consistent with the proximate
cause of damage being long term and ongoing foundation movement
a floor level survey showed the home’s eastern section, where the pipe leak had occurred,
had relatively settled. However, the leak had not caused the settlement because:
Determination | Case number: 882504 Page 3 of 6
> t he property slopes west to east. Any water at the dwelling’s rear would be directed
away. The subfloor being dry indicated water had not entered the rear (east) subfloor
> had the inadequate surface drainage saturated the reactive foundation soils and caused
footing movement, the footing near the pipe leak would have heaved not settled
the footing movement was caused by long term and ongoing differential moisture content
variations within the underlying reactive clay soils. The reasons for the variations included:
> tree root drying effects, noting the proximity of large trees to the east and south east
> typical seasonal moisture content variations
> differential permeability of ground and upper soil layers causing non-uniform moisture
penetration across the site, noting the floor level survey showed heave towards the
western side which was where permeable bare (garden bed) soil abutted the dwelling
> t he site’s natural slope, causing surface runoff to flow west to east towards the front
(west) of the dwelling and leading to long term increased moisture content in that area
> ventilation grills installed at ground level on the dwelling’s western side, allowing surface
water to easily enter the subfloor area and change soil moisture content on that side
the pipework damage at the rear of the dwelling was due to soil shrinkage as a result of
long term drying effects of trees. It had not occurred due to a one-off event
the damage to the dwelling was not the result of a single pipe leak event. It was the result
of differential soil moisture content variations caused by the factors it had listed.
SE also provided a report concerning the 5.9 magnitude earthquake on 22 September 2021.
The epicentre was 120km from the complainant’s property . The shaking experienced would
have been MMI IV on the Modified Mercalli Intensity (MMI) scale. Shaking at that level is felt
but does not cause damage. If the earthquake had caused or contributed to the claimed
damage, the cracking would have occurred across the entire dwelling, not just in one section.
T he EOL insured event excludes cover for ‘loss or damage caused by any gradual escape of
liquid’. The PDS also contains general exclusions precluding cover for:
damage caused directly or indirectly by or in any way connected with:
> subsidence or landslide (except, relevantly, i n the case of 'Earthquake’ claims)
> the vibration, settling, shrinking or expanding of earth of any building, foundation or wall
(except, rel evantly, in the case of 'Earthquake’ claims)
> the actions of trees, plants or their roots that occur slowly and gradually over time
gradual loss or damage of any kind.
The insurer says its expert reports show the proximate cause of the damage claimed is long
term ground movement linked to the drying effect of trees and the other factors SE identified.
Accordingly, the claim is excluded from cover.
Complainant maintains the claim should be accepted
The complainant says the insurer’s expert reports contain inaccuracies, are contradictory and
speculative rather than factual.
In response, he has provided a copy of an email dated 1 September 2022 from MM,
engineer. MM had inspected the property on 12 October 2021 and identified significant and
rapid footing movement. MM suggested leaking sewer or stormwater pipes were the likely
cause and had recommended the complaint engage a plumber to carry out an inspection.
The complainant’s plumber , DF, carried out CCTV inspection on 27 October 2021. DF has
provided a report dated 6 September 2022 confirming that its investigations showed the
Determination | Case number: 882504 Page 4 of 6
stormwater pipe had become dislodged underground from the junction. There was a 10 to
15mm gap and a cavity under the pipe. The cause of the dislodgement was unknown.
The complainant has provided a report dated 16 September 2022 by AG, gardener. AG said
that trees in the vicinity were unlikely to have caused foundation or stormwater pipe damage.
This was because of their non-invasive nature, size or distance from the dwelling. AG also
said the western ventilation grills were at mulch level, 10mm above the garden bed soil.
In addition, the complainant has provided a report dated 16 March 2023 by AE, engineer. AE
inspected the property on 13 March 2023 and advised:
the property should be considered an abnormal moisture condition site for reasons
including the pipe being dislodged for an indefinite period, permeable materials abutting
exterior walls and the natural slope downwards towards the building (inadequate drainage)
contrary to SE, it considered that the primary cause of damage to the exterior walls was
less likely to the drying effect of trees. Instead, it agreed with AG’s comments
stormwater discharging directly into foundation soils can have detrimental effects on a
building’s structural integrity, especially in regions with highly reactive soils. The 10 -15mm
gap DF located would have caused volumes of stormwater to escape
as the moisture content of reactive soil increases, the soil may undergo swelling, which
can cause building foundation uplift. When the soil dries and contracts, it may lead to
foundation settlement or subsidence. These movements can result in structural damage
its floor level survey results were co nsistent with SE’s. The results confirmed severe
differential footing movement consistent with differential settlement, noting the highest floor
deviation (down) was near the building’s south east corner where the pipe was dislodged
the stumps were slightly out of plumb, possibly due to differential settlement movement
the damage could have been a long term, ongoing issue due to the permeable materials
abutting the exterior walls and the inadequate site drainage from the slope, but the lack of
significant western wall damage and the floor survey results in that area were notable
it agreed with SE’s comments on the ventil ation grills, but the primary cause of the
building’s south east corner damage was highly likely the underground pipe leaks, which
worsened the differential settlement movement
it’s conclusion was ‘t he damages found at the exterior wall are consistent with severe
differential footing movement, mainly contributed to by the factors below:
> Inadequate founding depths of existing footings to alleviate the effects of foundation
movement caused by normal and ongoing seasonal moisture changes in the foundation
soils and other factors
> abnormal site moisture condition due to the leak in the underground pipe in the south-
eastern corner ’ .
The complainant says:
With all the evidence we provided we stand firm in the findings that the
stormwater downpipe located at the south-eastern corner leaking directly under
the foundation footing has caused the damage to our property and should be
covered under - Escape of liquid.
Insurer is entitled to deny the claim
I am on balance satisfied that the insurer is entitled to deny the claim. This is because:
the only e xpert commentary on the earthquake’s relevance is set out in SE’s second
report. SE has persuasively explained why the earthquake would not have been causative
Determination | Case number: 882504 Page 5 of 6
DW and SE conclude that the damage has occurred gradually, due to long term ground
movement. AE acknowledges that the stormwater pipe leak was over an indefinite period
SR observed the eastern subfloor to be largely dry after pressure testing. As SE noted, this
tends to suggest water from the stormwater pipe leak did not enter that area, but followed
the natural slope away from the dwelling ’s rear
if the stormwater pipe leak was the primary cause of damage, one would expect soil heave
in the south east corner, not soil subsidence. The floor level survey results obtained by SE
and AE both showed the most significant building settlement to be in that corner
AE concluded that the damage was consistent with severe differential footing movement
contributed to by a number of factors, only one of which was the stormwater pipe leak
While SE and AE disagree on whether tree root drying affects contributed to the differential
soil moisture content and therefore the footing movement, they agree the abnormal soil
conditions were in part due to permeable materials abutting the dwelling and the slope.
I am satisfied that the insurer has established it is more likely than not the dominant cause of
the claimed damage was ground movement (subsidence) over a period of time, unrelated to
EOL. The insurer has therefore shown the claim is excluded under the policy terms.
2.2 Is non-financial loss compensation payable?
No. The information provided does not show that the insurer delayed or otherwise mishandled
the claim.
AFCA can award compensation for poor claim handling
Under paragraph D.3 of the AFCA Rules, we may award compensation for non-financial loss
(capped at $5,400) where the insurer’s actions have caused an unu sual amount of:
physical inconvenience
time taken to resolve the situation
interference with the complainant’s expectation of enjoyment or peace of mind.
Insurer did not mishandle claim
The complainant says that the claim experience has been disgraceful, frustrating and very
stressful. He says that the insurer had formed the view that it would deny the claim before
obtaining expert reports, caused delays and was non-responsive.
The insurer issued its claim denial within the standard four-month timeframe specified in the
General Insurance Code of Practice. I am satisfied the denial was correct and based on
persuasive expert opinion. I also note that the insurer re-evaluated its position as the
complainant provided responding submissions and reports.
I acknowledge that the complainant has found the claim process stressful and inconvenient.
However, based on the exchanged information, I am not satisfied that the insurer delayed or
otherwise mishandled the claim. it is not required to pay non-financial loss compensation.
2.3 Why is the outcome fair?
The insurer has shown that the operative cause of damage was excluded ground movement.
It would not be fair to require the insurer to cover the claim when the policy does not respond.
It would also be unfair to expect the insurer to pay non-financial loss compensation when it
did not mishandle the claim.
Determination | Case number: 882504 Page 6 of 6
3 Supporting information
3.1 The AFCA process
AFCA’s approach is based on fairness
AFCA has determined this complaint based on what is fair in all the circumstances, having
regard to:
the legal principles
applicable industry codes or guidance
good industry practice
previous decisions of AFCA or its predecessor schemes (which are not binding).
The respective parties have completed a full exchange of the relevant information, and each
party has had the opportunity to address any issues raised. I have reviewed and considered
all of the information the parties have provided.
While the parties have raised a number of issues in their submissions, I have restricted this
determination to the issues that are relevant to the outcome.
We assess complaints on available information and circumstances
AFCA is not a court of law. We do not have the power to take or test evidence on oath, or to
require third parties to give evidence.
When we assess complaints, we consider:
available documents
the recollections of the parties
all relevant circumstances.
We give more weight to documents created at the time the events occurred. If there are no
relevant documents, we will decide what most likely occurred based on the available
information.
If there are conflicting recollections and these are evenly weighted, we may find that a claim
cannot be established.
Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.