Home / Suncorp Group / Determination 866352

Determination 866352

Insurer declined home damage claim for escape of liquid, relying on ground movement exclusion

FirmSuncorp Group
Decided2023-03-31
ProductGeneral Insurance · Home building and contents
OutcomeFor the complainant
Amount awarded$347,700
Non-financial loss—
Amount claimed$347,700
SourceAFCA PDF

Summary

The insurer declined a home claim for damage from leaking pipes, saying ground movement over time caused it. AFCA found the escape of liquid was the proximate cause and ordered payment of the full sum insured with interest, plus expert and exploratory costs.

The insurer failed to show the ground movement exclusion applied because the leaks were the proximate cause of the damage requiring demolition and rebuild.

Issues

Subjects and remedies

home or building damagepay claimpay compensationpay interest

Related

All Suncorp Group determinations · Find similar determinations

Text of the determination

Determination Case number 866352 Financial firm AAI Limited Determination | Case number: 866352 Page 2 of 10 Case number: 866352 30 March 2023 1 Determination overview 1.1 Complaint The complainant holds a home and contents insurance policy with the financial firm (insurer). He lodged a claim for damage to his property on 5 January 2021. He reported, at the time, he suspected the damage was being caused by the escape of liquid (EOL) from pipes. The insurer ultimately declined the claim. It says the damage was not caused by or connected to an insured event under the policy, but was from ground movement over time, which is a policy exclusion. The complainant disagrees. He believes the insurer should pay the full sum insured because, he maintains, the leaks caused damage which makes the property unrepairable. 1.2 Issues and key findings Is the insurer entitled to decline the claim? No. Leaking stormwater and sewerage lines caused damage to the property. While there is also evidence of longer term movement, the insurer has not established, on balance, exclusions apply to entitle it to decline the claim. That is because the escape of liquid events were, on balance, the proximate cause of the damage: without the leaks, the house would not need to be demolished and rebuilt (irrespective of any pre-existing movement and cracking in other areas of the property). The insurer is required to pay the full sum insured ($347,700), together with statutory interest on that amount, calculated from the date the claim was declined to the date of settlement. The insurer is also liable for any additional policy benefits which apply. As well, the insurer must cover exploratory costs (if any) incurred by the complainant in locating the leaks ; and the complainant’s experts’ costs (up to a maximum of $5,000 in total). The complainant is required to provide evidence of those costs. Statutory interest is to be added to those amounts, calculated from the respective dates of payment until settlement. 1.3 Determination This determination is in favour of the complainant. The insurer must pay $347,700, plus statutory interest on that amount in accordance with the Insurance Contracts Act 1984 (Cth) , calculated from the date the insurer declined the claim to the date of settlement. It must also cover any additional policy benefits which apply. As well, the insurer is required to reimburse the complainant ’s professional expenses incurred in obtaining reports from his experts (up to a maximum of $5,000), and exploratory costs (if any), plus statutory interest, subject to the complainant providing evidence of payment of those costs. Determination | Case number: 866352 Page 3 of 10 2 Reasons for determination 2.1 Is the insurer entitled to decline the claim? Complainant has established a valid claim The complainant lodged a claim after noticing substantial cracking and movement of the floor in late November/December 2020. It is not in dispute:  the neighbours had removed a desert ash tree from the western side of the property on 25 August 2020  there were several breaks in the service pipes on the western boundary of the property, from which water was escaping  there were trees on the eastern boundary of the property which were contributing to ground movement on that side of the property. The policy covers insured events including the escape of liquid (EOL), which is loss or damage caused by liquid leaking, overflowing or bursting from any of the following: … any drain, fixed pipes, roof gutters or guttering and rainwater downpipes, drainage and sewage systems; … The insurer accepts the complainant has established a valid claim for damage from an EOL. It initially accepted liability for damage (localised to the leaking pipes on the western boundary) to the ensuite, carport and driveway only, and offered to pay $39,474.60 based on a repair quotation obtained from MMBG, and inspection reports from BDD and CRD. After the complainant disputed that decision, the insurer arranged for further investigations, based on which it then declined the claim in full. That was on the basis of its expert MCS finding the damage was not the result of the leaking pipes, but concluding that the proximate cause of all the damage was ground movement over time. Insurer must show it is entitled to decline or limit its liability The policy contains a general exclusion for loss or damage caused by, arising from or involving: Ground Movement – erosion, vibration, subsidence, landslip, landslide, mudslide, col lapse, shrinkage or any other earth movement … In order to decline the claim, the insurer needs to show, on balance, that the exclusion for ground movement, on which it is relying, applies and is the proximate cause of the damage. Evidence indicates EOL caused damage, with contribution from other factors The complainant says all the damage he claimed was from the EOL and should be covered under the policy. He relies on the investigations and reports by geotechnical consultant ‘ U, ’ plumber ‘P,’ arborist ‘A’ , and sewer maintenance engineer ‘N . ’ P conducted a CCTV inspection of the service pipes concerned and reported issues in the services, including detached pipes, several large breakages, and obstructions; with the soil surrounding the damaged pipes being visibly wet. Determination | Case number: 866352 Page 4 of 10 Arborist A performed an assessment of the impact of the medium sized tree (desert ash) situated on the council nature strip to the south of the property, and reported:  feeder roots of this established tree have clearly penetrated the pipes  removal of tree of this size from reactive soil generally results in soil water no longer being absorbed by the tree roots. N also provided a report on the cause of the damage and refuted the ‘angle of repose’ issue raised by the insurer. N reported as follows:  the property footing was constructed beyond the angle of repose  the insurer’s expert M had incorrectly applied sewer measurements and trenching principles in calculating the angle of repose  the soil expanding on the south east side had caused the initial upward movement of the property before experiencing a downward movement  the proximate cause of the damage was the leaking pipes. U’s reports (7 December 2021, 30 May 2022, 5 July 2022) are based upon both visual inspections of the property and soil sampling, and include consideration of and responses to the insurer’s expert reports . U observes:  affected area mainly located around the carport area  previous neighbouring tree roots have cracked the sewer pipe, which has created abnormal moisture conditions within the soil due to the leaking water  cracked stormwater pipes also contributing to the abnormal moisture conditions within the soil  water entering the soil from pipe leaks made clay too wet. As a result, the clay began to swell and started to lift the house. The settlement at the front of the property from the carport to the kitchen is as a result of the soil losing its loadbearing capacity  four bore holes were dug; soil moisture and suction condition show very high moisture in bore hole one (western elevation) and moderate to high suctions in other three bore holes  clay in bore hole one was found to still be wet and soft (after the leaking pipe was repaired). In this condition, the ground movement would have reversed and is the cause of the settlement along the front of the house as far east as the kitchen  the property rests on natural silt clay, which has sufficient bearing capacity to support a house with normal moisture but is prone to movement if allowed to excessively wet up or dry out  floor levels show differential of -84 mm on south east corner and -18mm on southwest corner  desert ash tree caused soil movements and plumbing damage. The small trees have caused soil drying and settlement on the east side of the house only (around the entry, lounge and rumpus room)  in drought conditions, water would have caused the high water reactive volcanic clay to swell and commence lifting the nearby part of the house and garage slab  there is a longitudinal hump near the site of the removed Desert Ash  the worst wall damage is in the East wall of the ensuite (10 mm) which is located at the western side of the house  some parts of the house, the slab has cracked severely and will not allow it to behave as it was originally designed  the footing system to the carport is not within the angle of repose. Original building plans show the carport footing depth satisfies the angle of repose relative to the sewer  footings not inappropriately founded. In summary, U concluded: Determination | Case number: 866352 Page 5 of 10  the house slab, carport slab and house walls have been severely damaged by the variation in soil moisture. The slab is unable to be satisfactorily repaired  there is no doubt that if the water did not leak from the damaged sewer pipes, the house would not have sustained category 4 damage and would be able to be repaired. This is not possible; the house is unable to be fixed and requires demolition and reconstruction.  the slab settlement along the eastem edge is as a result of the drying effect of the vegetation. However, the movement experienced on the eastern side also has to be considered in the context of the movement of a large concrete structure, being the slab reinforced with steel mesh. The slab experiencing severe heave along the westem/southern edges would apply force along the eastern edge and exacerbate the downward movement along that side  proximate cause of the movement and resulting damage is the water from the leaking pipes, which has likely been occurring slowly over some time prior to being detected. Once the Desert Ash was removed in August 2020, the roots of the trees were no longer absorbing some of the excess water leaking from the damaged pipes.  estimate that the overall total damage from the shrinkage would contribute maybe 30%, however with the house being certain to continue moving the damage percentage from the leaking pipes would surely grow. The complainant’s experts broadly agree:  certain parts of the property were subject to movement from causes unrelated to the EOL, such as reactive soils and tree roots which affected the moisture content in the soils  roots from neighbouring trees penetrated and cracked the sewer line, resulting in the escape of a large volume of water causing soil to swell, the carport and house slabs to move to the extent they are unrepairable  even though issues unrelated to the EOL existed, the EOL was the primary (proximate) cause of the damage to the slabs. Insurer says damage was caused by natural ground movement over time The insurer maintains the damage was caused by natural ground movement, contributed to by the poor placement of service pipes next to the footings, the presence of trees, and natural soil conditions. The insurer relies on the investigations and expert reports from engineers ‘BDD’ , ‘CRD’ and ‘M’ . It had also arranged for an initial leak detection test by plumber WIA. WIA identified issues (cracks/blockages) in both the stormwater and sewer lines, at the rear north east and front south west corners of the house, including from root intrusion. BDD conducted an initial site inspection at the property (19 March 2021). It found:  affected area mainly around the carport area  cracking in carport infill slabs and pavers due to foundations heaving  major structural issue at this point of time is the cracked brick wall located at the ensuite wall. The size of the cracking suggests that the wall has been structurally affected. Infill and paving slabs located at the front of the property and in the carport have cracked and appear to have cracked due to foundations heaving  previous neighbouring tree roots have cracked the sewer pipe, and in turn causing leakage into the soil and causing abnormal moisture conditions within the soil. In turn the soil at this property appears to be moderately highly reactive as it has caused the slab to heave, and possibly cause the stormwater pipes to crack  the cracked stormwater pipes would also be causing further damage to the current situation as they are also contributing to abnormal moisture conditions within the soil. Determination | Case number: 866352 Page 6 of 10  heaved slab cannot be repaired, as there are no practical methods to restore it to its original state. CRD was engaged by the insurer to report on the damage and provide a scope of work for rectification required (16 July 2021). CRD reported:  minor damage from seasonal differential movement is considered normal in residential buildings  leaking pipe has only caused localised damage to the ensuite area and carport and driveway slabs  remaining damage caused by long term differential footing movement that has been exacerbated by abnormal moisture conditions (existing trees and removed trees)  based on local knowledge, soil conditions likely reactive clay. The likely site classification for the soil as being moderate to highly reactive. Reactive clay soils typically shrink and swell with fluctuating moisture content, which can result in differential footing movement, causing damage such as cracking to buildings.  floor levelling such as underpinning not recommended, as this can lead to future movement of footing system. M was engaged by the insurer to provide further opinions concerning the cause and to respond to the complainant’s material. In summary, M concluded (17 September 2021) the proximate cause of the building movement was ‘the following cumulative issues’:  building footing construction within proximity of an easement/within the angle of repose of main sewer branch  long-term presence of proximate vegetation  recent removal of proximate vegetation. M stated the purported sewer drainage leak(s) were not the proximate cause of the building movement, but that the building movement was a pre-existing issue that had been occurring over a long period of time. Evidence does not show building or construction defects The panel has considered the insurer’s suggestions of an inadequate footing system of the property, and issues relating to the angle of repose. The insurer has not argued the building and carport were not built according to the relevant regulations in the 1980s. Nor has it argued the regulations circa 1980 have the same construction requirements as those it sought to rely on to decline the claim (‘current industry standards’ ). The panel is not satisfied, in any case, current industry standards are relevant to the construction of the building and carport for the purposes of the insurer seeking to decline the claim. Even if it was, the panel is not satisfied the insurer has shown any alleged poor construction was the proximate cause of the damage. To the extent any construction issues existed and may have impacted the damage (which has not been established), the panel is not satisfied the insurer has shown these led to or caused any part of the loss. Proximate cause of slab movement and resulting damage was, on balance, EOL The experts agree there was an escape of liquid from broken pipes, and acknowledge:  the property is built on reactive clay soils which are prone to shrinkage when dry and swelling when wet, which can result in differential footing movement  differential footing movement can cause damage such as cracking Determination | Case number: 866352 Page 7 of 10  some of the damage to the property and carport is from ground movement unrelated to the escape of liquid. The experts also agree the slabs cannot be repaired, and the property needs to be demolished and rebuilt. However, they do not agree as to the proximate cause of the damage which now requires that rebuild. The proximate cause is a question of fact, based on the circumstances of each claim. There can be multiple factors which contribute to the damage. However, the proximate cause is the operative, dominant or effective cause. The courts have said that if one cause would have resulted in the harm in any case, and the other would not have done so in the absence of the first, then the first is the proximate cause. The available evidence in this claim indicates there were multiple contributing factors to the damage overall, with different causes likely affecting different areas of the property, and to varying degrees. The panel is satisfied the factors identified have all added to the underlying soil moisture variations, which have in turn led to movement and damage – some of it longer term, and some more recent. There is evidence of previous ground movement over an extended period, likely relating to natural seasonal movement and the effect of nearby trees. However, the panel considers the evidence shows, on balance, this movement only caused relatively minor cracking to the property (such as might reasonably be expected given the age of the building, the soil conditions and presence of trees). The extent of that ground movement and the damage resulting from that is not, in itself, such as would require the replacement of the slabs and the rebuild of the house. U was the only one of the experts who attempted to apportion the impact of the various causes, and he estimated the overall total damage from the shrinkage (as distinct from the impact of the leaks) would be 30%. U also relevantly noted that while the drying effect of the vegetation along the eastern edge of the house did affect the slab settlement there, that also had to be considered in the context of the movement of the large concrete slab reinforced with steel mesh which was experiencing severe heave along the western/southern edges. U indicated that western side movement would in turn have applied force along the eastern edge and exacerbated the downward movement along that side of the property as well. Relevantly as well, damage to the property from the leaking pipes was reported to have occurred within 3 months of the desert ash tree being removed. That indicates, on balance, the effect of the ongoing leaking had been mitigated by the presence of the tree, which had been absorbing moisture from the significant ongoing leaks. Having considered all the available evidence, the panel is satisfied it was the impact of the EOL from the damaged pipes which is the proximate cause of the damage more broadly across the property. While the immediate impact was to the carport and nearby areas, the resulting ground movement and slab movement in that area in turn, more likely than not, had a consequential (reactive) effect on other areas of the property. The panel is not satisfied that the ground movement in those other areas alone (or at all) would have necessitated the significant repair/rebuild work which is now required. In other words, if not for the EOL event(s) the significant slab damage would not have occurred and the house would not need to be demolished and rebuilt. That rebuild is now necessary regardless of any pre-existing cracking or movement damage. Determination | Case number: 866352 Page 8 of 10 Insurer is liable for full sum insured While the complainant has provided cost estimates to demolish and rebuild it for up to $475,000, the insurer’s liability under the policy is limited to the sum insured ($347,700). The panel is satisfied, in the circumstances, that the insurer should pay the full sum insured in settlement of the claim, together with statutory interest on that amount calculated from the date the claim was declined to the date of settlement. As well, the insurer is liable for any applicable additional policy benefits. The insurer is also liable, under the policy, for exploratory costs incurred in locating the leaks. If the complainant incurred such costs, then he is required to provide the insurer with evidence of that, and the insurer is required to reimburse those costs, together with statutory interest calculated from the date the costs were incurred to the date of settlement. Insurer required to contribute to complainant’s professional costs incurred Consistent with AFCA Rule D.5, the insurer is also required to reimburse the complainant (up to a maximum of $5,000) for his costs incurred in obtaining professional input from U, P, A and N. The panel is satisfied that input assisted in resolution of the complaint. The complainant is required to provide reasonable evidence of the costs incurred (such as invoices/receipts). 2.2 Why is the outcome fair? The outcome is fair in all the circumstances because the information provided indicates the proximate cause of the damage to the property (necessitating the demolition and rebuild) was, on balance, the escape of liquid from the service pipes. Determination | Case number: 866352 Page 9 of 10 3 Supporting information 3.1 The AFCA process AFCA’s approach is based on fairness AFCA has determined this complaint based on what is fair in all the circumstances, having regard to:  the legal principles  applicable industry codes or guidance  good industry practice  previous decisions of AFCA or its predecessor schemes (which are not binding). The respective parties have completed a full exchange of the relevant information, and each party has had the opportunity to address any issues raised. We have reviewed and considered all the information the parties have provided. While the parties have raised several issues in their submissions, we have restricted this determination to the issues that are relevant to the outcome. A panel determined this matter Due to the nature of this complaint, we referred it to a panel for determination. The panel includes:  an ombudsman  a member with significant experience in consumer and small business advocacy  a member with extensive experience in the insurance industry. We assess complaints on available information and circumstances AFCA is not a court of law. We do not have the power to take or test evidence on oath, or to require third parties to give evidence. When we assess complaints, we consider:  available documents  the recollections of the parties  all relevant circumstances. We give more weight to documents created at the time the events occurred. If there are no relevant documents, we will decide what most likely occurred based on the available information. If there are conflicting recollections and these are evenly weighted, we may find that a claim cannot be established. 3.2 Relevant policy wording Page Wording Determination | Case number: 866352 Page 10 of 10 26 Escape of Liquid We cover Loss or damage caused by liquid leaking, overflowing or bursting from any drain, fixed pipes, roof gutters or guttering and rainwat er downpipes, drainage and sewage systems Exploratory costs We will pay the reasonable cost of locating, at the insured address, the source of the escaped liquid and to repair and restore the damage to your home and contents caused by our ex ploratory work but only if the escape of liquid is covered under this insured ev ent. If the leak is not covered under this insured event, we provide som e limited cover for exploratory costs under additional cover ‘Explorat ory costs where a leak is not covered under insured event ‘Escape of liquid’’. See page 50. 87 How we settle your claim If we agree to pay a claim for loss, theft or damage to your home, we will decide if we will: 􀀀 repair damage to your home; 􀀀 rebuild your home; 􀀀 pay you what it would cost us to repair or rebuild your home; 􀀀 pay you the sum insured for your home; 􀀀 give you a voucher, store credit or stored value card for the amount it would cost us to repair or rebuild an item. If we reb uild (or pay you what it would cost us to rebuild), we will do so on a ‘new for old’ basis. .

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.