Home / QBE / Determination 862111
Determination 862111
Claim declined for home and pool damage allegedly caused by a leak
Summary
The complainant claimed under a home policy for cracking damage to the home and pool, which they attributed to an April 2020 leak from a broken stormwater pipe. AFCA found the insurer entitled to decline the claim because the damage was mainly caused by gradual differential footing movement, which the policy excludes.
The complainant could not establish on balance that the leak was the proximate cause of the damage, and the proximate cause fell within the policy exclusion for settling, shrinkage or expansion in buildings and foundations.
Issues
- Claim denial primary · not upheld
“The available information establishes, on balance, the proximate cause of damage is differential movement which occurred gradually... the insurer may decline the claim.”
- Inadequate claim investigation secondary · not upheld
“SW could not find any obvious discernible damage to the north east corner of the dwelling, being near the leak.”
Subjects and remedies
home or building damagenatural disasterno remedy
Text of the determination
Determination
Case number 862111
Financial firm QBE Insurance (Australia) Limited
Determination | Case number: 862111 Page 1 of 8
Case number: 862111 2 September 2022
1 Determination overview
1.1 Complaint
The complainant lodged a claim with the financial firm (insurer) in March 2021 for damage
caused by a leak in April 2020. The complainant says the leak caused widespread cracking
and movement damage to the home and swimming pool.
The insurer declined the claim. The insurer says there is insufficient evidence to establish the
damage was caused by a leak or any other insured event. It says the proximate cause of
damage is differential footing movement over time, and that damage caused in this manner is
excluded.
The complainant disputes this decision and says the insurer has failed to consider all relevant
information which establishes the leak caused the claimed damage.
1.2 Issues and key findings
Is the insurer entitled to decline the claim?
Yes. The available information establishes, on balance, the proximate cause of damage is
differential movement which occurred gradually. As the policy excludes damage caused in
this way, the insurer may decline the claim.
1.3 Determination
This determination is in favour of the insurer.
The insurer is entitled to decline the claim.
Determination | Case number: 862111 Page 2 of 8
2 Reasons for determination
2.1 Is the insurer entitled to decline the claim?
Yes. The available information establishes, on balance, the proximate cause of damage is
differential movement which occurred gradually. As the policy excludes damage caused in
this way, the insurer may decline the claim.
Complainant lodged a claim for damage caused by a leak
The complainant lodged a claim in March 2021 for damage caused by a leak from a broken
stormwater pipe on or around April 2020. The complainant says the leak resulted in cracking
damage to the main home and swimming pool.
The damage is described by the insurer‟s assessor (SW) as minor cracking to the inground
pool shell and surrounding concrete, and minor to moderate cracking throughout the home.
The complainant has the onus to establish the claimed loss falls within the insuring provision
under the policy. This must be established on the balance of probabilities.
If the complainant can establish this, the onus then shifts to the insurer to show it is entitled to
decline the claim.
Policy covers accidental damage
The complainan t‟s policy provides cover for accidental loss or damage to the home during the
period of insurance. The policy defines accidental loss or damage to be:
Physical loss of or damage to your home, contents, or both, at the address,
directly caused by any of the events listed in Section 1 – Home – Accidental
damage cover, which we will insure you against, subject to the Policy conditions
and exclusions.
Section 1 – Home – Accidental damage cover is described as follows:
We will pay for accidental loss of or damage to your home or contents at the
address other than the occurrences or items referred to in „What we will not pay
for‟.
This is the relevant insuring provision which the complainant must meet.
The policy does not define the term accidental. It does define accident as:
An incident that is unforeseen and unintended and that causes loss or damage.
This includes a series of accidents arising out of the one event.
The insurer says the policy requires the damage to have been caused by one event. I
disagree.
The insuring provision does not require the damage to be caused by an accident. It only
requires the damage itself to be accidental. This is an important distinction.
Determination | Case number: 862111 Page 3 of 8
Based on the wording of the insuring provision, this only requires the complainant to show the
damage claimed was unintended and unforeseen. There is no dispute this is the case.
Therefore, the onus shifts to the insurer to establish an exclusion, or other provision, applies
to deny the claim.
Policy excludes cover for accidental damage in some circumstances
The insurer has relied upon the following exclusions:
We will not pay for loss or damage … resulting from or caused by: …
wear, tear, rust, corrosion, depreciation or gradual deterioration;
settling, shrinkage or expansion in buildings, foundations, walls or
pavements.
Insurer’s engineer says damage occurred gradually
The insurer engaged engineer SW to confirm the cause of cracking to the home and
swimming pool.
SW carried out a floor level survey to measure the relative height of the floor across the
building. The floor level survey identified a maximum variance across the home of 14 mm,
and a maximum of 42mm across the rear veranda. SW says the main dwelling floor was
planar (flat), and the veranda floor falls from an east to westward direction, toward the
dwelling.
SW says the floor level survey is not consistent with an escape of liquid at the north east
corner (the site of the damaged pipe) where localised heave would be expected.
SW says the soil at the property is highly reactive clay, prone to shrink and swell with long
term soil moisture content variations. SW says several factors contributed to these variations,
including:
seasonal moisture content variations
differing permeability of the ground surface and upper (top) soil layers, resulting in non-
uniform moisture content variations
inadequate footing protection exacerbating differential permeability
soil drying effects of large trees planted near the building.
SW also says the presence of adjustable piers indicates the soil is reactive clay.
Regarding the pool, SW says the pool is too far from the damaged pipe to be affected by any
leak. SW considers the damage is most likely a result of concrete shrinking and a lack of
expansion joints, exacerbated by long term differential footing movement.
Complainant says damage occurred soon after the leak
The complainant says the damage occurred immediately after the leak. He has provided an
invoice dated 22 January 2021 for earlier works. This includes relevelling on 30 April 2020,
and repairs to the kitchen between May and September 2020. He says this establishes the
damage was caused by the leak.
The complainant says the floor level survey is not reliable evidence as the stumps were
adjusted and the floor relevelled after the leak.
Determination | Case number: 862111 Page 4 of 8
Further, the complainant says an effect of the relevelling was that the veranda on the eastern
side of the property separated from the main home. He also says significant cracks were
reduced to the currently visible cosmetic cracking.
The complainant supplied a report from engineer WJ dated 3 May 2021. WJ says it was
advised the veranda floor levels had lifted 40mm near the leak, and 35mm at the other
opposite end. WJ considers water from the broken pipe caused the reactive soil to swell,
lifting the footings. WJ also notes that adjustable piers are fully wound down, and the veranda
is unable to be further lowered.
Of note, in response to concerns the floor level survey is invalid, SW says there is no
evidence that existing cracking had closed as a result of relevelling. SW maintains cracking is
too remote from the leak location to have been caused by the leak.
Proximate cause of damage is differential footing movement over time
As noted, the insurer has relied on several exclusions to deny the claim. The insurer has the
onus of proof in establishing this. To do this, the insurer must show the proximate cause of
the damage is an excluded cause.
The proximate cause of the loss is a question of fact to be determined based on the
surrounding circumstances. Where there are several causes operating, each must be
examined for the qualities of predominance and efficacy in relation to the resultant damage.
After carefully reviewing the available evidence, I am not satisfied the proximate cause of the
damage was the leak.
There is no information to contest SW‟s view that the pool is too far removed from the leak
location to be affected. I also note that WJ has not supplied any commentary suggesting the
minor cracking to the concrete surrounds and pool shell are related to the leak. There is also
no information showing the damage is worse at the side of the pool closest to the leak.
I accept that since the floor has been relevelled, SW‟s floor level survey cannot be relied on to
gauge whether the leak has caused isolated heave. It is unfortunate the complainant
relevelled the floor before obtaining a level survey which may have indicated a pattern of
isolated heave at the leak location.
Regardless, the cracking identified by SW was predominately to the laundry and other rooms
on the western side of the property. These locations are not close to the leak. Importantly,
SW could not find any obvious discernible damage to the north east corner of the dwelling,
being near the leak. Even if cracks were closing due to the relevelling, SW correctly pointed
out these would still be identifiable.
It is clear the veranda is affected by movement. However, this is consistent across the length
of the veranda. I also note that heave is greatest in the central part of the veranda, which is
not proximate to the leak location.
In light of this, and given there is no pattern of increased damage or movement at or near to
the leak location, I am not satisfied the complainant has established the claimed damage is a
result of the leak. I consider, on balance, the proximate cause of damage is a result of
differential movement, most likely from the causes described SW. This would fall within the
policy exclusion for damage caused by settling, shrinkage or expansion in buildings,
foundations, walls or pavements.
Determination | Case number: 862111 Page 5 of 8
As the complainant has not established the damage is a result of the leak, and the proximate
cause of damage falls within a policy exclusion, I am satisfied the insurer is entitled to decline
the claim.
Outcome is fair in the circumstances
There is no dispute the property was accidentally damaged. However, the available
information shows the damage was predominately caused by differential movement. This falls
within the policy exclusion of settling, shrinking or expansion in buildings, foundations and
walls. Damage caused in this manner is excluded. Therefore, it is fair for the insurer to deny
the claim.
Determination | Case number: 862111 Page 6 of 8
3 Supporting information
3.1 The AFCA process
AFCA’s approach is based on fairness
AFCA has determined this complaint based on what is fair in all the circumstances, having
regard to:
the legal principles
applicable industry codes or guidance
good industry practice
previous decisions of AFCA or its predecessor schemes (which are not binding).
The respective parties have completed a full exchange of the relevant information, and each
party has had the opportunity to address any issues raised. We have reviewed and
considered all of the information the parties have provided.
While the parties have raised a number of issues in their submissions, we have restricted this
determination to the issues that are relevant to the outcome.
We assess complaints on available information and circumstances
AFCA is not a court of law. We do not have the power to take or test evidence on oath, or to
require third parties to give evidence.
When we assess complaints, we consider:
available documents
the recollections of the parties
all relevant circumstances.
We give more weight to documents created at the time the events occurred. If there are no
relevant documents, we will decide what most likely occurred based on the available
information.
If there are conflicting recollections and these are evenly weighted, we may find that a claim
cannot be established.
Determination | Case number: 862111 Page 7 of 8
3.2 Summary of expert reports
Summary of relevant reports
Record Summary of record
Complainant’s engineer (WJ)
Report
3 May 2021
WJ says “from the levels given to us” the veranda has lifted 40mm
near down pipe, and 35 mm, on the other end . It is unclear how
these levels provided to MJ were measured.
WJ notes a downpipe is leaking, and water from this will have
caused soil to swell , and that the veranda can no longer be lowered
as a djustable piers are fully wound up.
Insurer’s hydrologi st ( WT )
Report
11 May 2021
WT says water which inundated the property to floor level only was
floodwater. WJ describes the land as being flat, with water slow
moving and filled wit h sediment. Inundation was a day after rain
ceased. The timing consists with flooding of nearby Mehi River. This
is a highly persuasive report yet is not related to the leak.
Insurer’s engineer (SW)
Report
27 July 2021
SW says the soil is highly reactive and will swe ll and shrink
depending on soil moisture content.
There is a disused storm water pipe and new storm water pipe at
NE corner of dwelling beneath rear veranda.
There is an adjustable post and the NE subfloor corner which can
no longer be shortened.
The floo r level survey shows heave along the eastern side of the
property, falling westward toward the other side of the property .
The floor level is fairly consistent across the home wit h no
significant discrepancies in any one area .
SW considers the pattern of the floor level survey isn‟t consistent
with escape of liquid at the north east corner .
The cracking at the pool is far removed from the leak location
The adjustable footing post supports the view the soil is highly
reactive
The leak has not caused long t erm footing movement (ie, the
claimed damage)
The cracking around the concrete pool slab is consistent with
concrete drying and inadequate control joints and is not a structural
issue
This has been occurring over years and is unrelat ed to the claimed
even ts
SW
Supplementary Report
The insurer FF asks whether the adjustable footing which can no
longer be shortened is evidence of heave. SW says there is no
Determination | Case number: 862111 Page 8 of 8
Record Summary of record
28 September 2021 obvious damage above the repaired pipe SW sways the adjustable
steel posts indicate the property is predisposed to movement .