Home / IAG / Determination 858672

Determination 858672

Claim declined for garage ceiling collapse on the basis of faulty workmanship exclusion

FirmIAG
Decided2023-03-03
ProductGeneral Insurance · Home building and contents
OutcomeFor the firm
Amount awarded—
Non-financial loss—
Amount claimed—
SourceAFCA PDF

Summary

A home insurance claim for a collapsed garage plaster ceiling during a severe storm was denied by the insurer on the basis of non-compliant installation. AFCA found in favour of the insurer.

The proximate cause of the collapse was non-compliant ceiling installation, which falls within the policy's exclusion for structural defects and faulty workmanship.

Issues

Subjects and remedies

home or building damagenatural disasterno remedy

Related

All IAG determinations · Find similar determinations

Text of the determination

Determination Case number 858672 Financial firm Insurance Australia Limited Determination | Case number: 858672 Page 1 of 5 Case number: 858672 3 March 2023 1 Determination overview 1.1 Complaint The complainant holds a home and contents policy with the financial firm (insurer). On 9 June 2021, the plaster ceiling in the complainant’s garage collapsed (damage). The complainant lodged a claim with the insurer. The insurer denied the claim. It says the complainant has not shown the damage was caused by an event insured by the policy. In the alternative, the insurer says the damage is the result of faulty workmanship during installation, which is not covered under the policy. The complainant says he recently bought the property and obtained a building inspection which did not identify any issues. He considers the ceiling was installed correctly and the defects the insurer found was not the primary cause of the damage. 1.2 Issues and key findings Is the insurer liable for the damage? No. On balance, I am satisfied the proximate cause of the damage was the inability of the ceiling to withstand the loads imposed on it, due to the installer’s failure to comply with the requirements of the relevant building standards. The insurer is not liable for the damage. Why is the outcome fair? The policy excludes cover arising directly or indirectly from structural defects, including inherent defects, faulty design or workmanship. It would not be fair to require the insurer to cover the damage when it has not been shown to fall within the scope of cover. 1.3 Determination This determination is in favour of the insurer. The insurer is not required to cover the damage or take any further action in relation to the issues raised in this complaint. Determination | Case number: 858672 Page 2 of 5 2 Reasons for determination 2.1 Is the insurer liable for the damage? No. On balance, I am satisfied the proximate cause of the damage was the inability of the ceiling to withstand the loads imposed on it, due to the installer’s failure to c omply with the requirements of the relevant building standards. The insurer is not liable for the damage. Complainant has initial onus to establish loss covered by terms of policy It is accepted insurance law that the complainant carries the initial onus to establish, on the balance of probabilities (that is, more likely than not), a loss which is covered by the terms and conditions of the policy. Once the complainant has established a loss which is covered under the policy, the onus transfers to the insurer. It must establish the application of a condition, limitation or exclusion upon which it seeks to rely, to limit its obligations regarding the claim, or to deny the claim. Policy provides cover for damage subject to exclusions The policy is made up of the certificate of insurance (COI) and product disclosure statement (PDS). There is no dispute the insurer sent these documents to the complainant. When the complainant paid the policy premium, he is taken to have accepted the terms of the policy. The policy is an insured events policy. One of the insured events is storm. The PDS says the insurer will cover the complainant for damage caused by violent wind or thunderstorm (including a tornado or cyclone) and heavy rain, hail or snow. However, pages 42 to 45 list the general exclusions that apply. This relevantly says the insurer will not cover any loss, damage or liability arising directly or indirectly from, or connected with:  structural defects, including inherent defects, faulty design or workmanship  wear and tear, including gradual deterioration, rust, corrosion, fading or deterioration from exposure to light. The insurer says it is not satisfied the complainant lodged a valid claim under the policy. In the alternative, it says the ceiling collapsed due to inadequate and non-compliant installation. On this basis, the insurer decided to deny the claim. The insurer appointed a builder and roofer to inspect the damage On 10 June 2021, the insurer appointed a builder, UB, to determine the cause of the damage. UB appointed a roofer, BR. On 18 June 2021, BR attended the property and inspected the roof and garage. Relevantly, BR found:  the cement tiled roof was in satisfactory condition overall  there was no storm made openings or hail impact damage sustained to the roof tiling  the roof tiling appears to be predominantly water tight to this area  there was no evidence of any significant water entry other than minor dripping most likely from condensation found on collapsed plaster ceiling  water ingress does not appear to be a contributing factor causing the ceiling to collapse. Determination | Case number: 858672 Page 3 of 5 UB relied on the information BR provided. UB provided its report to the insurer in which it said the cause of the damage was: …the result of an original installation/des ign fault at the time the house was first constructed. As per our trade report and photos attached. No perimeter batten installed or insulation. In UB’s opinion, the damage was the result of poor workmanship during installation, which is not covered under the policy. UB recommended the insurer deny the claim. UB also provided photos BR took during its inspection of the garage. The complainant disagreed with UB and BR’s opinion On 26 July 2021, the insurer told the complainant it would be denying the claim and explained the outcome of UB’s report. The complainant disagreed with UB. He said he checked the building standards and there was no requirement for insulation or perimeter battens. The complainant says he bought the property recently before the damage. He obtained a building inspection. He says the inspection found no issues with the garage. He says this supports his position that the damage was not caused by faulty design or workmanship. The complainant also provided the monthly climate summary from the Bureau of Meteorology (BOM) for June 2021 and articles from Emergency Management Victoria. This information confirms that parts of Victoria experienced a severe weather event on 9 and 10 June 2021. The insurer arranged a further inspection of the damage On 29 July 2021, a supervisor at the insurer spoke with the complainant. It said the damage did not appear to be due to an insured event and there was no evidence of any storm created opening on the roof to allow the damage. However, the insurer said it would like to arrange a further inspection. It appointed CR, a building consultant and engineer company. On 5 August 2021, CR attended the property and inspected the damage. CR said the ceiling lining had been attached to the underside of the roof truss using a combination of adhesive and fastener fixings (gluing and screwing). It said the screws were installed at various spacings, with numerous adhesive daubs positioned between them. CR referred to Australian Standard 2589.1:1997: Gypsum linings in residential and light commercial construction - application and finishing. AS2589 relevantly says: Daubs of adhesive approximately 25 mm in diameter by 15 mm high shall be applied to the framing members at 230 mm maximum centres and at a minimum of 200 mm from the board edges and centre fasteners. CR noted that adhesive daubs had been installed somewhat haphazardly with the adhesive too close to the screw fasteners. In many cases, CR said up to three daubs of adhesive were installed between fasteners and within the 200 mm minimum spacing. CR said the ceiling failed prematurely due to incorrect installation and the incorrect installation was the proximate cause of the damage. Given the high winds during the storm, CR said the resultant and expected deflection in roof trusses caused the ceiling to collapse. Determination | Case number: 858672 Page 4 of 5 In CR’s opinion, if the plasterboard sheet ceiling was compliantly installed, it would not have collapsed during the storm. CR said the cause of damage was inadequate and non-compliant installation which exacerbated long term dilapidation. CR also says the ceiling was located within a closed garage. The complainant disagrees. He says there is an opening about 2.4 cm wide by 4.8 m long where the garage door cannot create a seal with the doorway lintel. He says this allows airflow directly into the ceiling cavity. The complainant disputes that the incorrect installation was a factor in the collapse. Rather, he says the high winds of the storm caused great deflection of the roof trusses. He says this, together with aerodynamic forces from gusts of wind in the ceiling cavity, caused the damage. I am satisfied, on balance, the insurer was entitled to deny the claim The complainant provided weather information confirming the severity of the storm on the date of the damage. He says there was damage to at least one tree in his street and records show there was a power blackout at his property. I accept the storm was severe. The complainant also refers to UB and BR’ s reports. He says UB and BR said the lack of a perimeter batten and insulation was an installation defect. He says a perimeter batten and insulation was not required by the relevant codes. It appears the insurer accepts this. However, the complainant has not provided any information to refute CR’s findings that the installation of the ceiling was inadequate and not compliant with AS2589. CR’s report says the non-compliant installation exacerbated the long-term dilapidation of the ceiling. The complainant says the additional adhesive applied at installation was a cosmetic defect rather than a structural defect. He says the additional adhesive provided a more secure and robust fixing to the ceiling and would not have caused the damage to occur. However, in its report, CR explained that where fixings and adhesive are installed too close together or in the same location, the fixings can pull through the plasterboard. It can also result in the failure of the bond between the adhesive and bottom chord of the roof truss. CR provided photos which show excessive adhesive was applied at installation and the adhesive was too close to the fixings. CR also provided photos of the fallen plasterboard where there was a failure of the bond between the adhesive and the roof truss. I have considered the building inspection the complainant obtained. However, the report confirms that no inspection or assessment was undertaken of the ceiling cavity in the garage. It is also unlikely the inspection could have observed the adhesives used to secure the garage ceiling (and it certainly was not commented on). Therefore, I do not consider this report assists the complainant. The complainant provided photos of the opening that he says allowed airflow into the ceiling cavity. This is not disputed. However, on balance, I accept the non-compliant installation of the ceiling increased the deterioration and was the proximate cause of the damage. Whilst I accept the severity of the storm contributed to the collapse of the ceiling, I consider this would not have occurred if it was properly fixed. The ceiling was not built according to the relevant standards. The PDS confirms the policy does not provide cover for structural defects, including faulty design or workmanship. On balance, I am satisfied this was the dominant or effective cause of the loss. This means the insurer was entitled to deny the claim. Determination | Case number: 858672 Page 5 of 5 3 Supporting information 3.1 The AFCA process AFCA’s approach is based on fairness AFCA has determined this complaint based on what is fair in all the circumstances, having regard to:  the legal principles  applicable industry codes or guidance  good industry practice  previous decisions of AFCA or its predecessor schemes (which are not binding). The respective parties have completed a full exchange of the relevant information, and each party has had the opportunity to address any issues raised. We have reviewed and considered all of the information the parties have provided. While the parties have raised a number of issues in their submissions, we have restricted this determination to the issues that are relevant to the outcome. We assess complaints on available information and circumstances AFCA is not a court of law. We do not have the power to take or test evidence on oath, or to require third parties to give evidence. When we assess complaints, we consider:  available documents  the recollections of the parties  all relevant circumstances. We give more weight to documents created at the time the events occurred. If there are no relevant documents, we will decide what most likely occurred based on the available information. If there are conflicting recollections and these are evenly weighted, we may find that a claim cannot be established.

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.