Home / IAG / Determination 857006

Determination 857006

hail damage roof repair defective, make safe work, concrete stump, claim handling delay

FirmIAG
Decided2022-09-19
ProductGeneral Insurance · Landlord
OutcomeFor the complainant in part
Amount awarded—
Non-financial loss$3,500
Amount claimed—
SourceAFCA PDF

Summary

The complainant disputed defective hail roof repairs and make safe work by the insurer's repairers. AFCA found the insurer must replace the roof and correct drainage, reimburse expert fees, and pay $3,500 non-financial loss, while rejecting the mould and septic tank claims.

The policy's replacement benefit requires repair to a condition as close as possible to new, so the roof must be replaced per the complainant's expert evidence.

Issues

Subjects and remedies

home or building damagenatural disasterthird party authoritypay non financial lossreassess claimrepair or rectify

Related

All IAG determinations · Find similar determinations

Text of the determination

Determination Case number 857006 Financial firm Insurance Australia Limited Determination | Case number: 857006 Page 1 of 9 Case number: 857006 1 September 2022 1 Determination overview 1.1 Complaint The complainant says the financial firm (insurer) is liable for corrective work to her property following a repair under a hail damage claim in October 2020. The complainant says the insurer’s tradesmen were unprofessional both with the work they performed and the way the y behaved during the repairs. The complainant says the roof repair is defective and it is likely the roof needs to be entirely replaced. Further, she says the insurer has unnecessarily delayed the claim by trying to re- use the same tradesmen as before and failed to complete reasonable emergency work which has resulted in additional damage to the property. The complainant seeks repair by a tradesman suitably qualified to work on a property like hers at the insurer’s expense. She also seeks repair of any ad ditional damage resulting from the poor make safe work now and into the future, and compensation for the claim experience. The insurer denies it handled the claim poorly. The insurer says it has been prepared to proceed with repairs since December 2021 an d would have done so but for the complainant’s objections. It says it has accepted the roof requires rectification, but a full roof replacement is not required. The insurer says the additional damage the complainant has raised concerns about is not connected with its conduct or the claim. 1.2 Issues and key findings Has the insurer correctly identified its liability? No. The insurer’s liability extends beyond its current position. The insurer is to accept rectification work and additional repairs in line with this determination. Should the insurer pay non-financial loss? Yes. The insurer must pay the complainant compensation for avoidable errors and the impact this has had on the complainant. 1.3 Determination This determination is substantially in favour of the complainant. The insurer is to accept rectification work, additional repairs and reimburse expert fees in line with section 2.1. The insurer is to pay $3,500 non-financial loss compensation. Determination | Case number: 857006 Page 2 of 9 2 Reasons for determination 2.1 Has the insurer correctly identified its liability? Policy provides the terms of the previous repair work The policy between the parties is a landlord insurance policy covering accidental damage and insured events. This means it gives broad cover for several listed events. It also covers damage to the insured property where the cause of the damage is accidental within the meaning outlined in the policy, limited by conditions and exclusions. The policy also sets out its commitments when it chooses to repair a property. Details of the relevant policy wording can be found in section 3 of this determination. Insurer should replace the roof There is no dispute the roof repair is defective. The complainant’s building inspector (DR) supplied a list of 71 defects in his report. The insurer’s building consultant (PG) accepted all but a handful of these defects as noted in section 3 of this determination. Having read both roof reports, it is clear there is still a dispute over the extent of the work needed to rectify the roof. PG suggests much of the roofing material can be re-used as it simply needs to be repositioned. However, I am not satisfied doing so will meet the terms of the policy. The policy is clear where the policyholder has taken the replacement benefit, which the complainant has, the repair must be to a standard as close as possible to when new. Both DR and PG agree there are multiple roof sheets and caps with overtightened screws, and visual evidence of damage to these as a result. Re-using these sheets does not meet the policy wording o f “as close as possible to when new . ” Further, PG suggests there are problems with the veranda beam and other pre-existing issues which have affected the quality of the roof repair. The report from the insurer’s previous builder (RI) did not note any maintenance work required of the complainant and has proceeded with replacing the roof by subcontracting to another repairer (SR). Accordingly, of the two reports, I prefer DR’s evidence. It is extensive, detailed, supported by photographs and logical. It is more likely to result in an outcome that will restore the roof to a condition in line with the policy conditions. Therefore, I accept DR’s evidence about the extent of works required. It follows the insurer must replace the roof in line with DR’s evidence. Insurer must meet the policy terms around make safe work The complainant has consistently raised concern about the make safe work. In particular, images supplied show a section of gutter has been used in lieu of a downpipe, angling away from the complainant’s roof. The complainant has supplied numerous photos showing the extent of water flooding into the subfloor area, which she says is due to the poor drainage. Determination | Case number: 857006 Page 3 of 9 These photos have been provided to the insurer. According to PG, no further make safe works are necessary. PG does not explain why, particularly given the complainant’s concern that this is causing water to enter the subfloor. On balance, I am not persuaded this arrangement is appropriate. I consider further works should be done to mitigate the water affecting the soil. Therefore, the insurer must correct this make safe work within seven days of the complainant accepting this determination if roof repairs are not due to commence within that timeframe. Concrete cancer, cracked window and septic tank DR’s report says the concrete footings now have significant moisture in them and one of the pillars is showing signs of concrete cancer. Others are showing efflorescence consistent with water saturation. PG disputes this in his second report. PG says concrete stumps are designed to withstand external application with constant contact with groundwater, surface water and ongoing inclement weather. PG says the cancer is likely due to the steel reinforcement being too close to the surface of the stump. On balance, I prefer DR’s evidence. The photos provided by the complainant show there has been excessive water entering the subfloor. This supports DR’s conclusion that one stump has been affected . In contrast, PG’s opinion is based on an assumption the concrete stump installed was constructed with the steel reinforcement being too close to the surface. However, there is no objective evidence substantiating this stump has that flaw. Neither does PG explain why excessive water into the subfloor could not be the cause of the concrete cancer. The insurer is liable to rectify this concrete stump. There is no evidence that other stumps have been damaged by concrete cancer. If further damage is identified, the insurer must assess them. I have also considered the complainant’s evidence a window has cracked and that this may be due to building movement relating to the water in the subfloor affecting the foundations. There is insufficient information to support this. Neither DR nor PG have provided any persuasive evidence to consider whether the surface water has caused foundation movement. For instance, neither report considers the type of soil the building is founded on, the normal site drainage conditions, vegetation, trees or floor measurements. All of this would be relevant to determine if the water in the subfloor is causing foundation movement that has resulted in the cracked window as opposed to other factors. Should there be further signs of building movement, the insurer must return with a suitably qualified expert (e.g. an engineer) and assess the damage. The complainant has also said the septic tank has been affected by the excessive ground water. PG did not consider this was the likely cause. PG said the foundation soils in and around the septic system would have consolidated and naturally compacted over its serviceable life. This would have occurred many years prior to the claimed event. If there had been a significant shifting of the foundation soils due to the recent claimed event, there would be evidence of subsidence on the surface. None was observed. Whilst the complainant says the septic tank issues are recent, there is no expert evidence in support. Given PG’s ev idence, I am not persuaded the available information shows the septic tank issues are caused by the claimed event or the repairs. Determination | Case number: 857006 Page 4 of 9 Insufficient evidence mould is related to faulty repair work I am not satisfied the complainant has shown the mould claimed is the result of the errors noted in this determination. The location of the mould does not have any corresponding evidence of water infiltration within the building, nor is there signs of water affecting the external areas nearby. The mould appears localised to one area of the house, which is not consistent with the signs of water flooding the subfloor area in various locations. Accordingly, I am not satisfied the available evidence, on balance, shows the mould is being caused by the defective works. Insurer to reimburse complainant for expert report fees The complainant provided three expert reports reviewing the roof, gutters, and subfloor area of the property. Under Rule D.5, AFCA may decide a financial firm contribute to the professional costs incurred by a complainant in the course of a complaint. These costs can be awarded if the complainant needed an expert to understand or establish their claim. These costs are normally capped at $5,000 unless exceptional circumstances apply. I am satisfied all three reports assisted the complainant to understand and establish her claim. Given this, it is fair the insurer compensates her for these costs. The complainant is to provide the insurer with paid invoices or receipts showing what was paid for these reports. The insurer is to settle the value of these reports or pay her $5,000, whichever is lesser, subject to the complainant accepting this determination. 2.2 Should the insurer pay non-financial loss? Compensation is awarded conservatively Under the AFCA Rules, we may award compensation (capped at $5,400) for non-financial loss where a complainant has suffered an unusual degree or extent of physical inconvenience, time taken to resolve the situation or interference with their expectation of enjoyment or peace of mind. We take a conservative approach to compensation for non-financial loss. It is not awarded when a person suffers the normal degree of inconvenience when a problem occurs. Insurer must compensate the complainant for the claim experience I am satisfied the complainant has suffered an unusual degree of inconvenience and interference due to the insurer’s claims handling. The claim has been ongoing now for almost two years, with substantive rectification work to the roof required. Other issues have been identified, such as the concrete cancer, which has been caused by the insurer’s claims handling . The complainant has been managing a relationship with a tenant living in the property during this time who will again be disrupted by further repair work. She has also organised multiple trips for herself or her real estate agent to attend the property while the insurer’s experts have been reassessing the damage. The complainant has made clear she felt ignored as her concerns were dismissed by the original roof contractor. To the extent this relates to the quality of the works, these have been Determination | Case number: 857006 Page 5 of 9 substantiated. Her concerns about the make safe work does not appear to have been actioned given the subfloor water entry. Overall, I consider the complain ant’s experience to be beyond minor and, at least, moderate. However, I note her tenant could still occupy the property, so she has not suffered loss of rent. I also note various items she was seeking, such as the mould and septic tank, have not been substantiated. Given this, and considering our conservative approach, the insurer should pay the complainant $3,500 non-financial loss compensation within 14 days of receiving notice she accepts this determination. Determination | Case number: 857006 Page 6 of 9 3 Supporting information 3.1 The AFCA process AFCA’s approach is based on fairness AFCA has determined this complaint based on what is fair in all the circumstances, having regard to:  the legal principles  applicable industry codes or guidance  good industry practice  previous decisions of AFCA or its predecessor schemes (which are not binding). The respective parties have completed a full exchange of the relevant information, and each party has had the opportunity to address any issues raised. We have reviewed and considered all of the information the parties have provided. While the parties have raised a number of issues in their submissions, we have restricted this determination to the issues that are relevant to the outcome. A panel determined this matter Due to the nature of this complaint, we referred it to a panel for determination. The panel includes:  an ombudsman  a member with significant experience in consumer and small business advocacy  a member with extensive experience as in the insurance industry. We assess complaints on available information and circumstances AFCA is not a court of law. We do not have the power to take or test evidence on oath, or to require third parties to give evidence. When we assess complaints, we consider:  available documents  the recollections of the parties  all relevant circumstances. We give more weight to documents created at the time the events occurred. If there are no relevant documents, we will decide what most likely occurred based on the available information. If there are conflicting recollections and these are evenly weighted, we may find that a claim cannot be established. Determination | Case number: 857006 Page 7 of 9 3.2 Relevant policy wording Glossary accidental loss of damage damage to, loss or destruction of the buildings that make up your rental property, or your contents when it is caused by an unintentional act, or an unforeseen and uncontrollable incident. Accidental damage cover We will cover your buildings and contents for any accidental loss or damage. There are also a number of incidents we will cover under specific conditions - there are listed on the following pages. How to make a claim … 3. If you need emergency repairs If you need to make emergency repairs, we will arrange assistance through our preferred repairers and suppliers. How we settle a buildings claim 1. We will decide how we will settle your claim If your building suffers loss or damage, we will decide whether to:  repair  … When we settle your claim, the law that will apply is the law of the state or territory where the loss, damage or liability occurred. … 4. If we decide to repair or rebuild your buildings and your current schedule shows ‘including replacement benefit’ We will repair or rebuild the part of your buildings that suffered the loss or damage to a condition as close as possible to when new, but not better. … Our guarantee Our guarantee assures you of quality insurance and service at all times. Fair dealing guarantee We will meet any claims covered by this policy fairly and promptly. … Service guarantee We will provide you with the highest standard of service. Determination | Case number: 857006 Page 8 of 9 3.3 Expert evidence summary Record Key points Insurer ’ s b uilder ( RI ) Building assessment report 18 December 2020  hail damage to the property requires full roof replacement of the main house  no maint enance of defect issues noted. Complainant’ s building inspector ( DR ) Roof assessment r eport 28 October 2021  works conducted by previous builder were unsatisfactory  71 items assessed as defective work  rectification work must meet the requirements of the QBCC, NCC, and manufacturers specifications. I nsurer’s building consultant ( PG ) Building inspection r eport 23 November 2021  disputes DR’s findings around flexible sealant use  misaligned roof sheets should be repositioned and planed during the repair rather than replaced . Some of the misalignment is due to a pre - existing issue  repairer’s attempt to avoid lobster tail hip capping is the best option while meeting complainant’s preference . Any correction to be resolved in consultation with the complainant  item 48 relating to gutter installation is disput ed. PG says no error in its installation  item 49 is also disputed. PG says veranda beam alignment is the reason for the defect, which is pre - existing and not part of the builder’s repair work  all other issues are agreed or accepted as items to resolve with the complainant. Complainant’ s building inspector ( DR ) Gutter and downpipe assessment r eport 11 March 2022  roof catchment exceeds the maximum allowance of a single 90mm downpipe and 100mm downpipe  recommends installation of four additional 100mm downpipes  downpipes to direct water to the site storage tank or to a suitably sized rubble pit a minimum of 3m from building. Complainant’ s building inspector ( DR ) Subfloor assessment r eport 11 March 2022  subfloor excessive damp throughout with scouring and ponding evident  majority of water ponding is near to the kitchen and back stairs  at the time of inspection, only one downpipe fitted to the dwelling  no downpipe installed at gutter outlet above kitchen and rear steps area where worst po nding is occurring  all concrete stumps showing high moisture content of 4 to 6% by weight  efflorescence occurring in the conc rete piers  long exposure will cause concrete canc er, or which there is early signs  stormwat er needs to be addressed immediately to prevent further water damage to the property  normal drying is adequate as the subfloor area is open and clear Determination | Case number: 857006 Page 9 of 9 Record Key points Insurer’s building consultant (PG) Building inspection report 9 May 2022  mould growth to the wall and ceiling of bedroom at north east corner, bu t no sign of water ingress or staining  external boards local to the mould growth showed signs of dust and debris, but no water tracks present  moisture test did not indicate elevat ed moisture readings  dust in the ceiling cavity did not show signs of water i ngress  mould growth likely due to irregular cleaning  disputes DR’s view concret e cancer is the res ult of excess surface water from gutter make safe  concrete cancer is due to long term gradual deterioration which is a maintenanc e item  unevenness of subfloor soil is allowing water to pond.  septic tank shows signs of recent repairs  septic tank showing signs of rotation and possible escape of liquid  rotation and movement likely predate the claimed event . More likely the damage is due to gradual deterioration a nd uneven ground movement over many years .

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.