Home / Youi / Determination 856922

Determination 856922

Retaining wall claim declined under defective construction exclusion

FirmYoui
Decided2022-09-13
ProductGeneral Insurance · Home building and contents
OutcomeFor the complainant
Amount awarded$36,650
Non-financial loss$2,000
Amount claimed$30,341
SourceAFCA PDF

Summary

The complainants' home insurance claim for storm-damaged retaining walls was declined under a defective construction exclusion. AFCA found the insurer failed to prove the exclusion applied and ordered payment of the rebuild, development application fees, expert report costs and non-financial loss compensation.

The insurer bore the onus of proving on the balance of probabilities that the wall was not built to applicable engineering criteria, and it failed to identify any applicable criteria that were breached.

Issues

Subjects and remedies

home or building damagenatural disasterpay claimpay compensationpay non financial loss

Related

All Youi determinations · Find similar determinations

Text of the determination

Determination Case number 856922 Financial firm Youi Pty Ltd Case number: 856922 12 September 2022 Determination | Case number: 856922 Page 2 of 6 1 Determination overview 1.1 Complaint On 23 October 2021 a very severe storm with winds exceeding 100kph caused damage including bringing down fencing and retaining walls at the complainants’ home. The complainants’ claim on their home policy was accepted by the insurer , except with regard to the retaining walls which were declined on grounds that that a policy exclusion applied to defective construction. 1.2 Issues and key findings Is insurer entitled to deny claim relying on defective construction exclusion? No, the insurer has failed to identify any applicable engineering criteria and any failure to accord with that criteria. The exclusion does not apply. Is the complainant entitled to compensation for non-financial loss? The insurer’s expert evidence was flawed resulting in substanti al stress and lost time by the complainants and an amount of $2,000 is appropriate. Why is the outcome fair? The outcome is fair because the insurer has fallen short in its attempt to prove defective design and construction. Reliance on an exclusion for alleged non-compliance with engineering criteria in circumstances where there was undoubtedly a severe storm, requires a careful and considered approach to the technical issues involved. 1.3 Determination This determination is in favour of the complainant. Within 14 days of acceptance of this Determination, the insurer is to pay the complainants the following:  $34,650 retaining wall/fence rebuild)  $2,621 development application fees  $2,080 reimbursement of expert report costs  $2,000 compensation for non-financial loss Determination | Case number: 856922 Page 3 of 6 2 Reasons for determination 2.1 Is insurer entitled to deny claim relying on defective construction exclusion? No, the insurer has failed to identify any applicable engineering criteria and any failure to accord with that criteria. The exclusion does not apply. Insurer has burden of proving exclusion applies I t is not in dispute that the complainants’ home suffered damage from a severe storm event on 23 October 2021 and that accordingly the onus shifts to the insurer to show an applicable exclusion in relation to the damage suffered to the retaining wall. The insurer has to prove on the balance of probabilities that the design and construction of the wall was not according to engineering criteria that applied at the time of construction. Insurer has not identified non-compliance with applicable engineering criteria The insurer referred to the following as applicable engineering criteria. AS4678 The insurer’s engineer (S E) reported the house and retaining wall were built in 2019 and that the wall was undersized for its retaining height of 600mm and that accordingly, the subject retaining wall does not comply with AS4678. Following receipt of a report from the complainants’ expert engineer, FE, it has been accepted that AS4678 does not apply to walls less than 800mm. SE maintains that the same principles still apply. However, the policy exclusion can only be sensibly construed as referring to some specific engineering criteria such as are contained in a well-known and applicable standards. AS4678 does not apply and therefore does not assist the insurer, nor has the insurer demonstrated that I am entitled to extrapolate “engineering criteria” from its general principles. AS3700:2001 SE further reported that the masonry retaining wall would be required to comply with AS3700:2001 – Masonry Structures Code. SE stated that design calculations indicated the retaining wall is significantly under-designed with regard to permissible tensile stresses on the wall. The complainant has submitted and it is apparently agreed that as at the date of the storm, AS3700:2001 was superseded by AS3700:2018. The insurer has not addressed whether there is any relevant difference between the two versions. The insurer has not provided or explained the calculations that apparently show a discrepancy with engineering criteria in AS3700. The standard apparently deals with the earth retaining strength of the wall. It is not explained how this is relevant in the present case where wind pressure on metal fencing erected on the retaining wall caused the damage. There is no suggestion of earth subsidence or movement causing the damage. Determination | Case number: 856922 Page 4 of 6 Manufacturing Guidelines SE has provided a document containing manufacturing guidelines for a concrete interlocking block retaining wall system similar to the proprietary system used by the complainant. SE says this guide shows steel fenceposts should be embedded through 3 such blocks and then core filled, whereas the complainant’s posts were embedded in only one block. As a general proposition this seems eminently sensible, but it is not the same system used by the complainant. In any event the document describes its content as “recommendations.” This is considerably less prescriptive than an industry standard. Imposed Load required engineering analysis Lastly in a Supplementary Report, SE refers to the manufacturer guidelines for the actual interlocking concrete block system used in the complainant’s retaining walls. The guidelines state “ If imposed loads are expected, the retaining wall should be designed by engineering analysis similar to that in the worked example, in RW0 3 Appendix A.” In other words, if there is an imposed load some appropriate customised designing is required. An imposed load was expected. The building plans provide for a solid metal 1.8 metre high fence to be installed on top of the retaining wall for the whole length of the backyard. Even a moderate wind would apply substantial lateral pressure to the fence and thereby to the retaining wall. On 23 October 2021 the pressure generated by the strong winds was sufficient in some areas to bend a number of the steel fencepoles and in other areas shift and dislodge the retaining walls. It is clear that the retaining walls failed. However, the insurer has not identified a failure to construct in accordance with any specific engineering criteria which applied at that time. It is simply unknown to me if any engineering analysis was done and if that analysis was or was not in accordance with the example in RW03 referred to above. It seems likely that no analysis was done. I say this because FE has observed the fence was erected by a different contractor to the landscaper who built the retaining wall. FE states “ It was, in this engineer’s opinion , correctly assumed by all parties involved that no engineering was necessary for works performed and how they interact with each other”. I do not agree with this statement. However, the insurer has the burden of proof. The insurer has failed to identify any applicable engineering criteria and any failure to accord with that criteria. The exclusion does not apply. Insurer to pay damage plus interest The complainants have not yet repaired the damaged retaining wall and have provided the following quotations and costs in support:  development application fees: $2,621  retaining wall/fence rebuild: $27,720  total: $30,341 The quote was issued on 1 December 2021. It is well known that building prices have risen steeply in the last several months. I have sought to factor this into my consideration of an appropriate cash settlement. I have considered contingencies and the absence of an insurer guarantee. I apply a 25% loading on the $27,720 making an amount of $34,650. Determination | Case number: 856922 Page 5 of 6 Insurer to reimburse cost of expert ’s report The cost for F E’s report was reasonably incurred and the report materially assisted the complainants’ position in advancing their claim. The insurer is required to reimburse the complainants the cost incurred of $2080. 2.2 Is the complainant entitled to compensation for non- financial loss? Insurer’s declinature reveals a lack of scrutiny of its expert’s report. AFCA has the power to award compensation for non-financial loss up to $5,400 in circumstances where there has been significant distress and or inconvenience caused by an insurer in the conduct of a claim. AFCA expects complainants to have a reasonable level of resilience. In the present case there was clear evidence that the com plainant’s house had been hit by a severe storm which caused widespread damage to properties in its path and resulted in substantial media reporting. For an insurer to rely on an exclusion for failure to comply with engineering standards in respect of a component of that damage would usually require clear and compelling evidence. Unfortunately, the first report by SE contained a number of significant errors. A careful reading of SE’s report by the insurer would have revealed these errors. However, the insurer persisted in its declinature. It was entirely reasonable for the complainant to obtain a fresh engineering report. In addition to incurring these costs the complainants clearly devoted substantial time and effort to their written submissions to the insurer and to AFCA. In the circumstances and considering the stress involved I consider an amount of $2,000 is appropriate. 2.3 Why is the outcome fair? The outcome is fair because the insurer has fallen short in its attempt to prove defective design and construction. Reliance on an exclusion for alleged non-compliance with engineering criteria in circumstances where there was a severe storm, requires a careful and considered approach to the technical issues involved. Determination | Case number: 856922 Page 6 of 6 3 Supporting information 3.1 The AFCA process AFCA’s approach is based on fairness AFCA has determined this complaint based on what is fair in all the circumstances, having regard to:  the legal principles  applicable industry codes or guidance  good industry practice  previous decisions of AFCA or its predecessor schemes (which are not binding). The respective parties have completed a full exchange of the relevant information, and each party has had the opportunity to address any issues raised. We have reviewed and considered all of the information the parties have provided. While the parties have raised a number of issues in their submissions, we have restricted this determination to the issues that are relevant to the outcome. We assess complaints on available information and circumstances AFCA is not a court of law. We do not have the power to take or test evidence on oath, or to require third parties to give evidence. When we assess complaints, we consider:  available documents  the recollections of the parties  all relevant circumstances. We give more weight to documents created at the time the events occurred. If there are no relevant documents, we will decide what most likely occurred based on the available information. If there are conflicting recollections and these are evenly weighted, we may find that a claim cannot be established. 3.2 Policy provisions

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.