Claim denial for subsidence and cracking damage allegedly caused by leaking pipes
Text of the determination
Determination
Case number 839301
Financial firm AAI Limited
Determination | Case number: 839301 Page 1 of 12
Case number: 839301 20 June 2022
1 Determination overview
1.1 Complaint
The complainants held a home and contents policy with the financial firm (insurer) and first
lodged a claim for damage caused by a leaking pipe in 2018. The insurer declined the claim
as it determined the damage was not caused by a leaking pipe but most likely ground
movement which is excluded from cover.
The complainants lodged a second claim in August 2019 after further leaking pipes were
located which they say contributed to the cracking. Following further assessment of the claim
the insurer denied the claim. The insurer says the damage to the property was the result of
ground movement, roots and climate conditions specifically excluded by the terms of the
policy.
The complainants say the reports confirm the leaking pipes contributed to the ground
movement and damage is seeking for the insurer to accept the claim for internal and external
cracking damage to the property.
1.2 Issues and key findings
Is the insurer entitled to decline the claim?
Yes. The panel is satisfied that most likely the damage occurred over time due to ground
movement which is excluded from cover under the terms of the policy. While the leaking
pipes may have contributed to the movement in a section of the property, on balance this did
not cause the damage. The proximate cause of the movement was due to ground movement,
tree roots and climate.
Why is the outcome fair?
The panel is persuaded by the expert reports that the proximate cause of the damage was
not the leaking pipes but had occurred over time because of ground movement, roots and
climate. It is fair in the circumstances that the insurer can rely on the terms and conditions of
the policy to refuse payment of the claim.
1.3 Determination
This determination is in favour of the insurer.
The insurer is entitled to deny the claim in accordance with the terms and conditions of the
policy.
Determination | Case number: 839301 Page 2 of 12
2 Reasons for determination
2.1 Is the insurer entitled to decline the claim?
Yes. The panel is satisfied the available information establishes that most likely the damage
occurred over time due to ground movement which is excluded from cover under the terms of
the policy.
Complainant has onus to prove claim falls within terms of the policy.
It is established insurance law that an insured has the initial onus to prove on the balance of
probabilities (that is more likely than not) that the loss or damage claimed falls within the
terms of the policy. This is commonly called a prima facie claim.
The complainants Home and Contents policy provides cover for a series of insured events
including the escape of liquid subject to several conditions and exclusions. The relevant
policy wording is set out in section 3.3 of this determination.
There is no dispute there have been several leaking pipes at the property. The available
information indicates that most likely the pipes had been leaking gradually. The policy does
not cover loss or damage caused by the escape of liquid because of a gradual process if you
could reasonably have been aware of the event. The panel accepts that the complainants
could not reasonably have been aware of the leaking pipes before 2018.
What is in dispute is whether the proximate cause of the damage to the property was the
escape of liquid from the leaking pipes. The proximate cause of the loss is a question of fact,
depending on the circumstances in each case. The proximate cause is not necessarily the
first or the last or the sole cause of loss. It is the effective or dominant or operative cause of
the loss.
If there are several causes operating contemporaneously, then each must be examined for
the qualities of predominance and efficiency as the active, efficient cause that sets a relevant
chain of events in motion.
Circumstances of loss
This claim relates to damage caused by foundation subsidence. The property is in North
Queensland. According to the complainants cracking was first observed in August
/September 2017 with major cracking of floor and wall tiles, gyprock sheeting and external
brickwork happening since late 2018.
A damaged pipe in the ensuite was found and repaired in January 2018. The complainants
lodged a claim with the insurer around that time. The insurer denied the claim after obtaining
a report from an engineer JHA. The initial report from JHA dated 14 September 2018 found
that the cracking was a result of prolonged drought conditions and trees being in close
proximity. JHA found that the movement and cracking was not due to the leaking pipe.
A further claim was lodged on 24 August 2019. The complainants had been in the process of
having resin injection to stabilise the foundation slab and had dug trenches around the side of
the property. This revealed further broken pipes along the left side of the property, in the
areas of the outside of the laundry, bathroom, toilet and ensuite. Further broken pipes were
found under the under the foundation slab.
Determination | Case number: 839301 Page 3 of 12
The complainants say that while the proximity of trees to the house is always a possible
cause of damage this was not the case here. They say that when the trench running parallel
to our house was dug to locate the sewage pipes almost no tree roots were found and
therefore almost no tree roots were under the foundation slab.
The complainants concede drought might exacerbate foundation movement and damage to
the slab. They note however that the pre-purchase house inspection in 2012 showed very
little signs of movement despite droughts having occurred since the house was built.
The complainant relies on the pre-purchase inspection report and engineer report compiled
by LPE to argue water released from the cracked pipes was the primary cause of damage to
the foundations and slab.
Reports indicate damage reported in 2018 had occurred over time
The pre-purchase report conducted by DK in 2012 identified cracks on both the north and
southside of the building and recommended a structural engineer be appointed to assess the
severity of the cracking. The panel accepts the report indicates that until that time any
foundation movement to the existing residence was quite minimal.
After the complainant lodged the claim in 2018, the insurer’ engineer JHA attended the
property on 11 September 2018. At that stage it was reported that the drainage pipes from
the ensuite toilet had been blocked by tree roots with the drainage pipe repaired in January
2018. JHA considered the cracking caused by abnormal moisture conditions in the foundation
soil and that were three factors contributing to this namely:
> Leaking pipe.
> Prolonged drought conditions - the whole of the Western Downs Council area (which
includes Chinchilla) was drought declared from 1 March 2014 to 17 May 2018.
> The house is located within the zone of influence of trees.
JHA considered the cracking to the property was the result of prolonged drought conditions
and the effect of trees on a reactive clay site. The leaking pipes had not contributed to or
caused the movement and damage to the insured property.
The complainants engineer BA reported on 7 November 2018 that there had been a history of
movement in the property as evidenced by minor paint repairs. The foundation movement
was expected on this type of site due to highly reactive clay soil, but the movement had been
exacerbated by:
> trees within the zone of influence.
> extensive drought.
> moisture introduced by the cracked drainage pipe.
BA concluded that the cracked and leaking drainpipe has had an influence on the extent of
cracking and damage to the building. BA, concluded that although the pipework is assumed
to have been compliant at the time of installation, the combination of a lack of flexibility in the
drain pipework, seasonal wet/dry cycles and progressively increasing drying effects of nearby
trees (as the trees mature) has caused the pipe to crack.
The panel notes BA did not find the cracked drainage pipe the dominant or effective cause of
the damage.
The panel accepts based on the reports provided after the first claim, that while the identified
leaking drainage pipe may have contributed to the abnormal moisture levels, the evidence
does not establish this was the proximate cause of the loss.
Determination | Case number: 839301 Page 4 of 12
Reports following claim in 2019 confirm damage has occurred over time
After the second claim was lodged JHA had a subsequent site visit.
JHA noted the movement at the property was not isolated to the area of the reported leaks
but rather it was to the entire property. Floor levels were taken for comparison with the levels
recorded in 2018 and only minor changes were noted further supporting the view that
movement had been occurring over time.
JHA identified five possible contributors at play that potentially result in movement of the
founding soils. These included:
> the presence of reactive clay soils
> prolonged drought conditions
> the house being located within the zone of influence of trees
> evidence of leaking pipes
> resin injection undertaken around most of the perimeter of the house in
July 2019.
JHA explained that, with no other factors at play, moisture from the leaks could be expected
to be absorbed into the founding soil causing the soil to swell and raising the floor levels
around the leaks. However, the floor levels recorded did not show localised heave around the
leaks. Therefore, based on the available evidence JHA concluded the leaking pipes have not
contributed to the movement. It says:
The complainants engineer LPE concludes with saying the cracking to the house is a result of
significant foundation movement with the most likely sequence of events being:
> Normal variations in subsoil moisture content-initiated ground movements that cracked
a plumbing pipe that did not have expansion and or swivel joints provided.
> The roots of the nearby tree extended outwards looking for a source of moisture. The
roots extended into some of the plumbing pipes looking for moisture;
> The tree roots blocked some of the drains and required cleaning from time to time;
> After the drainage pipe was repaired the tree roots could no longer source water from
the plumbing. The tree roots therefore sourced moisture from the adjacent ground
which resulted in ground conditions changing from excessive moisture to very dry
conditions. This resulted in large foundation movements and building damage.
This is consistent with the information provided by JHA and confirms the damage to the
property was not caused by the leaking pipes but most likely occurred over time due to
several factors.
Insurer entitled to refuse the claim within the terms of the policy
If there are several causes operating contemporaneously, then each must be examined for
the qualities of predominance and efficiency as the active, efficient cause that sets a relevant
chain of events in motion.
The reports establish that the proximate cause of the damage was not the leaking pipes or
any other insured event to which the policy responds, but rather, most likely caused over a
time due to ground movement including subsidence, tree roots and climatic conditions.
The damage to the leaking pipes was most likely caused by the ground movement and tree
roots throughout the drought period. Further the photographs of cracked pipes provided by
LPE indicates that the existing house plumbing was not originally provided with expansion or
Determination | Case number: 839301 Page 5 of 12
swivel joints to the plumbing. It is considered that the lack of articulation to the plumbing pipes
has been the main cause of the cracking to the pipework.
The policy does not cover ground movement including subsidence or any other ground
movement. The reports indicate the damage was most likely caused by ground movement of
the reactive clay soil.
The policy does not cover loss or damage caused by atmospheric or climatic conditions.
There is no dispute the area had been in an extended drought. This would have contributed
to the abnormal moisture condition of the foundation soil.
The policy does not cover damage caused by tree roots. The reports confirm the property
was located within the influence of trees. The influence of trees would have increased as they
matured and through the extended drought.
The panel is not satisfied the complainants have established the leaking pipes caused the
damage to the home. The policy excludes damage caused by ground movement, tree roots
and climatic conditions. As such, the panel is satisfied the insurer is entitled to deny the claim.
2.2 Why is the outcome fair?
The panel is persuaded by the expert reports that the proximate cause of the damage was
not the leaking pipes but had occurred over time because of ground movement, roots and
climate. It is fair in the circumstances that the insurer can rely on the terms and conditions of
the policy to refuse payment of the claim.
Determination | Case number: 839301 Page 6 of 12
3 Supporting information
3.1 The AFCA process
AFCA’s approach is based on fairness
AFCA has determined this complaint based on what is fair in all the circumstances, having
regard to:
> the legal principles
> applicable industry codes or guidance
> good industry practice
> previous decisions of AFCA or its predecessor schemes (which are not binding).
The respective parties have completed a full exchange of the relevant information, and each
party has had the opportunity to address any issues raised. We have reviewed and
considered all the information the parties have provided.
While the parties have raised several issues in their submissions, we have restricted this
determination to the issues that are relevant to the outcome.
A panel determined this matter
Due to the nature of this complaint, we referred it to a panel for determination. The panel
includes an ombudsman, a member with significant experience in consumer and small
business advocacy and a member with extensive experience in the insurance sector.
We assess complaints on available information and circumstances
AFCA is not a court of law. We do not have the power to take or test evidence on oath, or to
require third parties to give evidence.
When we assess complaints, we consider:
> available documents
> the recollections of the parties
> all relevant circumstances.
We give more weight to documents created at the time the events occurred. If there are no
relevant documents, we will decide what most likely occurred based on the available
information.
If there are conflicting recollections and these are evenly weighted, we may find that a claim
cannot be established.
3.2 Expert reports
Record Key points
Insurer’s Engineer Report
( JHA )
14 - 09 - 2018
There has been a history of foundation movement as evidenced by
the internal wall cracking that had been painted over.
There are 3 contributors at play here that potentially result in
abnormal moisture conditions in the founding soils:
Determination | Case number: 839301 Page 7 of 12
> Leaking pipe.
> Prolonged drought conditions - the whole of the Western Downs
Council area (which includes Chinchilla) was drought declared
from 1 Marc h 2014 to 17 May 2018.
> The house is located wit hin the zone of influence of trees.
The date marks on some of the internal wall lining cracks indicate
that the cracks have been progressing since the drainage pipe
was repaired
Based on the avai lable evidence, the cracking to the hous e is a
result of prolonged drought conditions and trees being near the
house. The movement and cracking is not due to the leaking pipe.
The sequenc e of events is as follows:
> The drainage pipe broke at some unknown t ime as a result of
seasonal ground movement and prolonged drought conditions.
> The roots of the nearby tree extended outwards looking for a
source of moisture. They found a ready source in the broken
drainage pipe.
> The tree roots resulted in blocked drain s which were cleaned out
from time to time.
> After the drainage pipe was repaired, the tree was no longer
able to source moisture from the pipe and so drew it from the
neighbouring ground. Prolonged drought conditions and a thirsty
tree have resulted in the founding soils drying out whic h has
caused ground movement and associated building movement
and cracking.
The cracking type noise heard by the Insured is attributed to
thermal movement of the roof sheeting and framing as the various
building elements cool do w n over night and then progressively
hea t up during the day. This is a common phenomena.
Insurer’s Engineer
Supplementary Report ( JHA )
18 - 10 - 2018
cracks that have been painted over indicates that there has been
a history of building movement and damage over the years
which is pertinent to our investigation.
Floor levels show that the lowest levels are at the left hand rear
corner of the house (near the leak location but not at the leak
location) - the closest point to the neighbouring trees. The floor
and wall in t hat area has settled.
Further evidence that supports that conclusion is the fact that the
date marked cracks (all near the leak location), have become
longer since the leak was repaired. If the leak was the cause, the
cracking would not increase aft er the leak was repaired. In fact, as
the moisture in the soil from the leak dissipated, some recovery of
the movement and cracking could be expected. This has not
occurred, which indicates that the leak is not the cause. The
explanation that best fits the facts, is movement from prol onged
drought conditions and the presence of large trees located close to
the house.
Based on the evidence available, it is our professional opinion that
the movement and cracking to the house in the vicinity of the leak,
and also elsewhere in the house, would still have occurred, even if
Determination | Case number: 839301 Page 8 of 12
the leak had not occurred.
Insurer’s Structural Engineer
Report ( BA )
01 - 10 - 201 8
There has been a history of movement in the building evidenc e by
the minor paint repairs to internal wall/ceiling linings throughout the
building.
This movement is likely to be within acceptable performance limits
as recommended by AS2870, as the function of the building does
not appear to have been impaired over the duration of its life and
the size, extent and pattern of movement would appear within
reasonable limits.
It is only relatively recently that the more significant cracking has
been noticed and the cracked drain pipe was identified.
I t is considered that the cracked and leaking drainpipe has had an
influence on the extent of cracking and damage to the building.
Although the pipework is assumed to have been compliant at the
time of installation, the combination of a lack of flexibility in the
drain pipework, seasonal wet/dry cycles and progress ively
increasing drying effects of nearby trees (as the trees mature) has
caused the pipe to crack.
The nett result of the moisture introduced by the cracked pipework
together with drying effects of the trees is for more significant
building movement to b e visible than would be from just one of
these effects alone.
Insurer’s Engineer Report
( JHA )
01 - 10 - 2019
A leak to the plumbing pipes had initially been found outside the
ensuite, and then, further leaks to the pipes outside the main
bathroom and laundry etc – towards the rear of the left side of the
house. Further investigations then found leaks to the pipes under
the slab in the main bathroom and the ensuite.
Much of the cracking and damage observed was similar to what
was observed and photographed durin g our 2018 inspection.
Some of the new damage is located in areas away from the leaks,
the trees, and the resin injection. It is concluded that they are the
result of continued drought conditions.
Other leaking pipes outside the left side of the house have recently
been identified and repaired. It is not known how long they have
been leaking.
With no other factors at play, the potential damage area resulting
from the leaks is shown on the following sketch (superimpos ed on
the sketch of damage locations). It can be seen that most of the
damage is well away from the expected damage area, and as
such, has not been caused by the leaks
The conclusion to be drawn from this is that the leaking pipes have
not contributed to the movement and damage experienced by the
house.
In fact, due to the prolonged drought conditions, the moisture from
the leaks would serve to mitigat e against the movement and
damage caus ed by the trees in the drought conditions. In other
words, the movement and damage would have been more sever e
if the leaks had not occurred.
Determination | Case number: 839301 Page 9 of 12
Based on the available evidence, the movement and cracking to
the house has been caused by drought conditions and the effect of
trees on a reactive clay site. The leaking pipes have
Based on the available evidence, the seq uence of events is as
follows:
> The drainage pipe that was repaired in January 2018, broke at
some unknown time as a result of seasonal ground movement
and prolonged drought conditions. It is likely that the other
damaged pipes had also been damaged at the time.
> The roots of the nearby tree extended outwards looking for a
source of moisture. They found a ready source in the broken
drainage pipes which meant the moisture from the leaks was
quickly absorbed from the soil before it was able to affect the
found ations of the house.
> After the leaking pipe was repaired in January 2018, the other
pipes continued to leak, and the tree continued to draw moisture
from the soil in the drought conditions.
> In July 2019, a contractor carried out resin injection works whi ch
raised the slab/footings in some areas (up to 10 mm).
> Our inspection at the end of August 2019 included ret aking of
floor levels across the house. Thes e levels were not significantly
different to those recorded in September 2018. This means that
betwee n September 2018 and August 2019, the ongoing
drought conditions resulted in further additional movement to the
house and footings and that the further additional movement
was largely negated by the resin injection process.
Insurer’s Engineer
Supplementa ry (Plumbing)
Report ( JHA )
19 - 11 - 2019
There is no localised heave or alteration to the general pattern of
contours in the area of the leaks.
The available evidence is not consistent with movement and
damage to the house having been caused by the various leaks.
After reviewing the supplied emails and attachments, we affirm our
previous conclusion that the movement and cracking to the house
has been caused by drought conditions and the effect of trees on
a reactive clay site. The leaking pipes have not contributed to or
caused the movement and damage to the house.
Determination | Case number: 839301 Page 10 of 12
Complainant’s Engineer
Report (LPE)
14 - 06 - 2021
It is common modern practice to pro vide expansion and swivel
joints to house plumbing installations. The photographs of cracked
pipes provided indicates that the existing house plumbing was not
originally provided with expansion or swivel joints to the plumbing.
It is considered that the la ck of articulation to the plumbing pipes
has been the main cause of the cracking to the pipework. The
effect of the cracked pipework has created abnormal moisture
conditions that has amplified the latter influence of drying
conditions due to drought and the influence of adjacent trees.
Based on the available evidence the cracking to the existing house
is a result of significant foundation movement. Based on the
available evidence it is considered that the most likely
sequence of events included the follow ing:
> Normal variations in subsoil moisture content - initiated ground
movements that cracked a plumbing pipe that did not have
expansion and or swivel joints provided. Ground conditions
would have become saturat ed at the location of the broken
pipework;
> The roots of the nearby tree extended outwards looking for a
source of moisture. The roots extended into some of the
plumbing pipes looking for moisture;
> The tree roots blocked some of the drains and required cleaning
from time to time;
> After the drainage pipe was repaired the tree roots could no
longer source water from the plumbing. The tree roots therefore
sourced moisture from the adjacent ground which resulted in
ground conditions changing from excessive moisture to very dry
conditions. This resulted in la rge foundation movements and
building damage .
3.3 Relevant policy wording
Page Policy wording
22
Escape of liquid
We cover
Loss or damage to the building caused by liquid
leaking, overflowing or bursting from any of the
following:
…
• any drain, fixed pipes, roof gutters or guttering and
Determination | Case number: 839301 Page 11 of 12
rainwater downpipes, drainage and sewage systems;
…
We do not cover
• the cost of repairing or replacing the item from which
the liquid escaped;
37
You are not covered under any section of your policy
for damage, loss, cost or legal liability that is caused by,
arises from or involves:
Ground movement
erosion, vibration, subsidence, landslip, landslide,
mudslide, collapse, shrinkage or any other earth
movement, but we will cover landslide or subsidence
that is specifica lly covered under the following insured
events:
.......
39
Roots of tree s, shrubs and plants
the roots of trees, shrubs or plants, but we will cover
damage to your building caused by:
• liquid leaking or overflowing from pipes or drains that
are blocked or damaged by these roots to the extent it
is covered under insured event ‘Escape of liquid’;
• roots from a fallen tree to the extent it is covered
under insured event ‘Impact’.
40
You are not covered under any section of your policy
for damage, loss, cost or legal liability that is caused by,
arises from or involves:
Determination | Case number: 839301 Page 12 of 12
Wear, tear and gradual deterioration
wear, tear, rust, fading, rising damp, mould, mildew,
corrosion, rot, action o f light, atmospheric or climatic
conditions or gradual det erioration such as, but not
limited to:
• tiles and their adhesive or grouting breaking down;
• weathering of roof tiles or roof ridge capping;
• gradual weathering and breakdown of bricks, mortar
or concrete.
Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.