Water ingress damage claim declined by insurer relying on wear, tear and lack of maintenance exclusion
Text of the determination
Determination
Case number 838717
Financial firm Allianz Australia Insurance Limited
Determination | Case number: 838717 Page 1 of 9
Case number: 838717 23 June 2022
1 Determination overview
1.1 Complaint
The complainant holds a home building and contents policy (policy) with the financial firm
(insurer). On 16 April 2021, a claim was lodged seeking cover for water ingress damage to
the insured building.
The insurer has declined the claim. The insurer says the damage is because of wear, tear,
gradual deterioration and a lack of maintenance relating to the box gutter installed at the
insured property, which is excluded under the policy.
1.1 Issues and key findings
Is the insurer’s assessment of its liability u nder the claim reasonable?
No. The available information establishes, on the balance of probabilities, that the claimed
damage is because of an overflow of the box gutter during a storm. This is an insured event
under the policy. The insurer has not been successful in showing, on balance, an entitlement
to decline the claim in line with the policy provisions.
Why is the outcome fair?
The outcome is fair in all the circumstances as an insured event has been established and
the insurer has not shown an entitlement to rely on a policy exclusion to decline cover for the
damage to the insured building.
1.2 Determination
This determination is in favour of the complainant.
The insurer is to accept the claim and cover the complainant for the damage to the insured
building in line with the policy provisions.
Within 14 days of the insurer receiving notification the complainant accepts this
determination, the insurer is to obtain a scope of works and actionable repair quote from a
suitably qualified consultant. The insurer, at its discretion, can either authorise repairs or cash
settle.
If the claim is settled by way of a cash settlement, the insurer is to base the final cash
settlement of the cost of repairs plus a further 20% to account for contingencies and the
transfer of risk to the complaint in having to arrange the repairs.
Subject to being provided with evidence of payment, the insurer is to reimburse the
complainant for costs he may have incurred in sourcing the various consultants‟ reports in
support of his position.
Determination | Case number: 838717 Page 2 of 9
2 Reasons for determination
2.1 Is the insurer’s assessment of its liability reasonable?
No. The available information shows, on balance, the internal water ingress damage claimed
is the result of an overflow of the box gutter during a storm event. This satisfies the
requirements of a valid claim under the policy.
The policy is an insured events contract of insurance
The policy covers the insured property against loss or damage caused by one or more of the
listed insured events, including „ Storm ‟. Cover under these benefits is subject to the
conditions, limitations and exclusions specified in the product disclosure statement (PDS).
The insurer provided the complainant with the relevant policy documentation, including the
PDS and certificate of insurance (COI). Therefore, I accept the insurer is entitled to rely on
the policy provisions to assess its liability under the claim.
The complainant has established a valid claim
It is established insurance law that an insured bears the initial onus to prove on the balance of
probabilities (that is more likely than not) that the loss or damage claimed falls within the
terms of the policy. This is commonly called a prima facie claim.
Once this has been established, the onus shifts to the insurer to establish, on balance, that it
is not responsible to cover the complainant for the loss in line with a provision or exclusion
present in the terms of the policy.
The policy covers the insured property against loss or damage caused by a storm. Cover
under this insured event is subject to the policy exclusions. This includes there being no cover
if rainwater, run-off, hail, wind or water that enters the insured building through an open door,
window or other opening except for openings made by the storm.
There is no dispute the insured building has suffered stormwater ingress damage in the
upstairs areas of the bedroom, hallway and bathroom located to the northern side of the
home. The damage is in the form of water staining, blistering and some cracks in the area
where the walls meet the ceilings.
I am satisfied the available information, on balance, supports a finding that the insured
building has suffered damage because of stormwater ingress. As such a valid claim exists
under the policy. The onus rests with the insurer to establish, on balance, it is entitled to
decline the claim in line with the policy provisions or otherwise.
The insurer says the stormwater ingress has not occurred through a storm created opening.
Instead, it came through openings present because of wear, tear, gradual deterioration and a
lack of maintenance of the gutters and flashing, which is excluded under the policy.
The consultants have provided conflicting opinions
The insurer appointed various consultants to the claim, as did the complainant, to determine
the cause and extent of the damage. Relevant information from these reports has been
provided in section 3 below.
The insurer appointed loss adjusting consultants „S‟ to manage the investigation and
assessment of the insured property. S appointed „P‟ to complete a roof report . P in a report
Determination | Case number: 838717 Page 3 of 9
dated 6 May 2021, noted water damage, stains and blistering affecting the plaster. P formed
the view this was consistent with long term water exposure relating to deteriorated silicon
serving the flashings around the chimney area and noted issues with the installation of the
guttering.
A forensic building report dated 16 June 2021 provided by „SB‟ also noted issues with the
installation of the box gutter. However, SB says due to time since its installation and no
evidence of previous water ingress, it is unlikely the current damage relates to the gutter
installation. SB says the damage is directly related to a breakdown of sealant in the guttering
system over an extended period of time. S recommended a leak detection assessment be
completed.
The insu rer appointed „L‟ to complete a leak detection assessment. L did on 7 July 2021. L
inspected the roof space and noted water staining to the rafters below the edge of the box
gutter consistent with staining caused by an overflowing gutter. L noted no obvious openings
or damage to the roof.
L concludes the damage is due to water ingress through unsealed flashing and wall interfaces
around the chimney. L noted that it was possible that the gutter overflowed during the storm
due to the choke point in the gutter around the chimney. Water is also getting into the external
wall through cracked and unsealed render.
S, having reviewed the information from P, SB and L, supports the view that the damage
claimed relates to the issues with the deteriorated silicone and flashings in the area of the
chimney as well as additional unsealed areas. S notes the gaps in the flashings are below the
edge of the box gutter and any ponding/rising water would penetrate via these lower openings
first (before overflowing).
The complainant relies on the opinions from consultants „K‟ and „MB‟ who he appointed to
assess the cause and extent of the damage. Both K and MB, are of the view the damage is
not consistent with the issues noted with the silicone and flashing, rather, that it is consistent
with a stormwater overflow event.
S notes that a leak through failing silicone would discharge water along a pathway which
would be quite specific and identifiable. This is not the case at the insured property. The
bubbling pattern is classic overflow. The photos of the gutter show it is folded over from one
piece which extends to the other side of the intermediary wall, down that wall, across the
internal brick wall and then under the roof to approximately 200mm above the cladding.
S says the guttering is not in pieces. This means the only way for water to enter inside is by
overflowing of the gutters and disproves the insurer‟s position regarding water leaking through
guttering at its base.
MB says the damage is consistent with a storm event completely overflowing the gutters and
back flowing. This is supported by the storm water stains visible on timber roof rafters,
battens and ceiling insulation. The entire length of the boundary wall is damaged because of
water ingress through roof sheet corrugations.
The insurer has not shown an entitlement to rely on the policy exclusions
Given the matters discussed above, and considering what is fair in all the circumstances, I am
not persuaded the insurer has shown an entitlement to decline the complainant‟s claim in line
with the policy provisions.
Determination | Case number: 838717 Page 4 of 9
I note, despite several references to issues with the installation of the box gutter, the insurer
has not relied on the policy exclusion relating to its installation as a basis to decline the claim.
Further, the forensic building report provided by the insurer says that given the time the
guttering has been in place and the absence of evidence of previous water ingress, it is
reasonable to accept that the installation of the box gutter is unlikely to be the cause for the
water ingress damage subject of the claim.
I accept the fact there was evidence of deteriorated silicone and some gaps around the
chimney area which would, on balance, have allowed internal water ingress. However, I am
not satisfied this has been shown to be a significant contributing factor. Rather, on balance, I
am of the opinion it is reasonable to argue that the major and therefore dominant cause for
the damage claimed is an event where stormwater has overflowed the gutter.
This is because, I find the information from K and MB to be the more persuasive and
consistent with the physical evidence. This physical evidence includes water staining to the
rafters, bearers and insultation within the roof space. The fact the damage is wide spread and
continues for the entire length of the northern side of the building also supports an overflow
event.
K‟s view is also compelling in that if the water ingress from the area of the chimney were the
dominant reason for the damage, both the pattern and location of the damage would not be
as it is in this instance. I note even the insurer‟s appointed leak detection specialists
confirmed water staining to the rafters is consistent with an overflowing event.
I acknowledge the weather data does not show a significant weather event to have occurred
in the time relevant to this claim. However, it does show there did take place rainfall events
from the end of January 2021 to March 2021. It has been observed in the past that the impact
of a weather event may be significant in one area when compared to another area a short
distance away. Further, an overflow would occur if there is intense rainfall in a short space of
time. The weather data does not disprove such an event occurred.
It is not unreasonable to accept that given the design of the box gutter, it may have a higher
potential to overflow than gutters of a different design or installation method. This does not
change the fact there is no dispute the insured building presents with physical evidence of an
overflow event and there no persuasive information to indicate there was an ongoing water
ingress issue at the property.
Therefore, despite the fact there may have been some minor water ingress occurring around
the chimney, I am not satisfied this has been shown to be the dominant cause for the damage
to the walls and ceilings within the home. Rather, the damage is the result of an event where
stormwater has overflowed the box guttering and entered the home.
The insurer is to accept the claim and cover the damage to the insured building
Given the matters discussed above, I determine the insurer is to accept the claim and fulfil its
obligations as set out in the policy provisions.
The insurer, at its discretion, is to either authorise and arrange for the necessary repairs or
cash settle the complainant for the cost to arrange the repairs.
If the claim is to be cash settled, this is to be based on an actionable quote from an
adequately qualified builder arranged by the insurer. The insurer is to increase the cash
settlement by a further 20% to allow for contingencies and the transfer of risk to the
complainant in arranging the repairs.
Determination | Case number: 838717 Page 5 of 9
Subject to being provided with evidence of payment, the insurer is to reimburse the
complainant for costs he may have incurred in sourcing the various consultants‟ reports in
support of his position.
2.2 Why is the outcome fair?
It is fair to accept, given all the available evidence and the fact an insured event has been
established, that the damage is related to or arose from an event where the guttering has
overflowed with stormwater. While I accept the insurer has provided reports to dispute this
outcome, I am not satisfied it has established, on balance, the damage is due to
circumstances excluded under the policy.
Determination | Case number: 838717 Page 6 of 9
3 Supporting information
3.1 The AFCA process
AFCA’s approach is based on fairness
AFCA has determined this complaint based on what is fair in all the circumstances, having
regard to:
the legal principles
applicable industry codes or guidance
good industry practice
previous decisions of AFCA or its predecessor schemes (which are not binding).
The respective parties have completed a full exchange of the relevant information, and each
party has had the opportunity to address any issues raised. We have reviewed and
considered all the information the parties have provided.
While the parties have raised several issues in their submissions, we have restricted this
determination to the issues that are relevant to the outcome.
3.2 R elevant consultants’ information
Record Key points
S First Report
29 April 2021
Complainant did not advise the damage was due to a storm,
rather, cause of damage noted as „unknown‟
Referenc e to possibly damage being because of construction
works at neighbouring property
P Roof Report
6 May 2021
Noted water damage, staining and blistering affecting plaster
ceilings
Damages are indicative of long term water exposure
Inspection of roof found deteriorated silicon serving flashings
around chimney area - primary cause of water ingress and noted
damage
Noted issue with box gutter installation
S Forensic Building Report
16 June 2021
Date of inspection 24 May 2021
Complainant has owned property for 15 - 20 years
Complainant advised damage due to stormwat er ingress
Water ingress damage apparent to nort hern elevation
plasterboard ceiling in upstairs bedroom hallway at high levels
between wall and ceiling junction
Notes issues with box gutter installation and not being compliant
with „Installation Code for Meta l roof and Wall Cladding SA HB39 -
1997‟
Due to time since installation and no evidence of previous water
ingress, unlikely damage relates to gutter installation
Damage is directly related to a breakdown of sealant in the
Determination | Case number: 838717 Page 7 of 9
Record Key points
guttering system over an extended pe riod of time
Leak det ection test should be completed to determine exact cause
and location of water ingress.
L Roof Inspection Report
9 July 2021
Date of attendance 7 July 2021
Water damage in bedroom is next to the chimney and under the
box gutter - damage in the hall is also below box gutter
Inspected the roof space and found water staining to rafters below
the edge of the box gutter which is consistent with staining caused
by an overflowing gutter
No obvious openings or damage noted from within roof space
Inspected roof, in reasonable condition wit h no damage or missing
items located
L found:
- During make safe works the flashing joins and interfaces
were re - sealed with fresh silicon. L was unable to determine
the condition of these areas prior to the storm
- The gutter around the chimney is a common choke point
which can overflow easily. This is a common issue with this
type of gutter around a chimney on these old buildings
- T here is a large gap bet ween the capping and the chimney
that was not sealed at the time of the make safe. L a ssume s
this is what the repaired flashings were like prior to their
repair. If so, they would have allowed water into the
bedroom and hall
- The rain head overflow point is too high. It is higher than the
sole of the gutter. If the rain head were to become blocked
and overflow, water may leak under the gutter into the
building before overflowing externally.
- The external wall on the northern elevation has a large
cr ack running along it that will allow water behind the
rendered surface. This water will then enter the wall through
the old bricks and mortar, keeping the wall damp.
Spray testing was not conducted due to limited access and safety
issues
The cause of dama ge is water ingress through unsealed flashing
and wall interfaces around the chimney
L also suspects suspect that the gutter overflowed during the
storm due to the choke point in the gutter around t he chimney
Water is also getting into the external wall th rough the cracked
and unsealed render.
K Email
11 January 2022
It is obvious during heavy downpour, water has overflowed over
the internal gutter due to extraordinary volume
Damage is not consistent with the single area noted within the
guttering
The bubbling of the stair wall in particular shows extreme event
causes massive water damage consistently along the wall which
demonstrates an overflow problem as opposed to a leak of a
single area within the int ernal guttering.
Determination | Case number: 838717 Page 8 of 9
Record Key points
K Email
13 January 2022
in K‟s professional opinion, this issue isn‟t about silicon or any
failing of silicon. It is absolutely, unequivocally from a massive
overflow during torrential rain where the int ernal gutter filled and
overflowed over most or entire length
The system is only as good as the down pipe discharging the
water and in this case the water could not discharge in time
therefore the flooding
A leak, from say, failing silicon would discharge water along a
pathway which would be quite specific and identifiable. This is no t
the case at insured property. The bubbling pattern is “classic ”
overflow
K Email
11 February 2022
35 years‟ experience , and in his opinion, the issue is not related to
a silicone failure
Damage to the ceilings is above the gutter wit h multiple entry
po ints
Water can travel along beams to an exit point but cannot travel
upwards, which is what the insurer is suggesting
Failure of silicone within internal gutter would mean water would
flow down the cavity between the double brick wall of the inter
tenanci es
Some water would absorb into the back of the internal brick layer
displaying as mould or staining or rising damp at ground level .
Neither the complainant‟s or neighbouring properties showed such
damage.
S Further comments
28 January 2022
Note that the date of the c laimed event was advised to be 2 April
2021 . B OM data for Melbourne (Olympic Park weather station
No. 086338, around 3.0km away) confirms insignificant 7.6mm of
cumulative rainfall bet ween 13/ 02/2021 and 13/03/ 2021 and
4.6mm of cumulative rainfall between 26/03/2021 and 8/04/ 2021
The only severe (but n ot extreme) rainfall in the first half of 2021
was experienced on 30/01/2021, 43.2mm .
Both roof reports note the evidence of box gutter overflow
(wat er - stained framing timbers ). However, that would be also the
case if water travelled via the unsealed gaps in the flashings
noted in both roof reports
There were also some additional unsealed areas which wo uld
definitely allow water ingress in case of water ponding in the box
gutter due to the de fective box gutter installation
The Forensic Building Report only stated that water ingress was
“ lik ely related to a break down of sealant in the guttering system
o ver an extended period of time”. S of the opinion that the cause
of ingress is related to the failed / absent flexible sealant and
gaps in the flashings rath er th an overflow from the box gutter
This is because these gaps in the flashings are below the edge
of the box gutter and any ponding / rising water would penetrate
via these lower openings first.
Determination | Case number: 838717 Page 9 of 9
Record Key points
S Further comments
(Attached to insurer email
24 Februar y 2022)
It is possible ceilings are installed lower than the box gutter and
which could result in damage due to overflowing gutter
However, K‟s diagram and referenc e showing ceilings lower than
the box gutter is wrong
It shows chamfered section of the ceil ing, but this is not how the
residence is constructed
Photos from the forensic report do not show chamfered junction
but clearly show 90 - degree angle between walls and ceilings
Photos showing depth of roof void inside the roof void suggest
internal ceilin g levels could be lower than box gutter
Regardless of if the water ingress is from an overflow of the gutter,
the gaps noted in the flashings are below the edge/around the
base of the box gutter
So, any ponding/ rising of water in the gutter would leak through
these lower level opening s first (before any possible overflow)
Point 2
Point 3
K Email
15 March 2022
S has relied on text book examples of what gutters looks like.
Referenc e to diagram 6. 1.1. in S‟s information is not a box gutter
as found in Victorian Terrac es and is a valley gutter
Photos of the actual gutter shows it is folded over from one piece
that extends from the ot her side of the intermediary wall, down
that wall, across the internal brick wall and then under the roof to
approximately 200mm above the cladding - not in pieces
The only way for water to enter is above that side in a massive
downpour and that is absolutely repres ented in the interior
damage to ceilings and walls consistently along that side of the
house .
MB Inspection Report
1 April 2022
Confirms damage to walls and ceiling in upstairs hallway,
bedroom and bathroom 1
Damage consistent with major storm event completely overflowing
the gutters and back flowing
Storm water stains visible on timber roof rafters, battens a nd
ceiling insulation - the entire length of the boundary wall due to
ingress through roof sheet corrugations
Major storm event resulting in large volume of water – moisture
affected insultation battens, in this section, need to be removed
and replaced.
Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.