Home / IAG / Determination 836554

Determination 836554

Garage ceiling storm damage claim declined

FirmIAG
Decided2022-02-23
ProductGeneral Insurance · Landlord
OutcomeFor the firm
Amount awarded—
Non-financial loss—
Amount claimed—
SourceAFCA PDF

Summary

The complainant lodged a landlord insurance claim for garage ceiling damage said to be caused by a June 2021 storm; the insurer declined it as gradual deterioration, wear and tear and defective installation. AFCA found the insurer entitled to decline the claim under the policy exclusions.

Damage caused by gradual deterioration, wear and tear, or defective workmanship is excluded, and on balance the evidence from the insurer's consultants showed the ceiling failed due to adhesive ageing rather than the storm.

Issues

Subjects and remedies

home or building damagenatural disasterno remedy

Related

All IAG determinations · Find similar determinations

Text of the determination

Determination Case number 836554 Financial firm Insurance Australia Limited Determination | Case number: 836554 Page 1 of 5 Case number: 836554 23 February 2022 1 Determination overview 1.1 Complaint The complainant holds a landlord insurance policy (policy) with the financial firm (insurer). On 15 June 2021, a claim was lodged for the damage to the ceiling in the garage which the complainant says occurred during a storm on 11 June 2021. The insurer has declined the claim on the basis the damage to the ceiling is because of age, wear, tear and defective installation. The policy excludes loss or damage caused by gradual deterioration and defective workmanship. 1.2 Issues and key findings Is the insurer entitled to decline the claim? Yes. The available information shows, on balance, the sagging of and ultimate partial collapse of the garage ceiling is due to age and wear and tear and a failure of the adhesive securing the plaster sheets to the timber framework. This is excluded under the policy. Accordingly, the insurer is entitled to decline the claim. 1.3 Determination This determination is in favour of the insurer. The insurer is entitled to decline the claim for the damaged garage ceiling in line with the policy. The insurer is not required to take any further action. Determination | Case number: 836554 Page 2 of 5 2 Reasons for determination 2.1 Is the insurer entitled to decline the claim? Yes. The available information shows the failure of the garage ceiling was due to the gradual deterioration of the ceiling adhesive and manner in which it was secured to the timber framework. This is excluded under the policy. The policy is an accidental damage contract of insurance The policy covers the insured property against accidental loss or damage. Cover under the policy is subject to the conditions, limitations and exclusions specified in the product disclosure statement (PDS). The policy defines accidental damage to be loss or destruction to the insured building and contents by an unintentional act or an unforeseen or uncontrollable incident. There is no dispute the damage to the garage ceiling was unexpected and outside the complainant ’s control. The onus therefore rests with the insurer to show it is, on the balance of probabilities, entitled to limit or decline indemnity under the claim based on the policy provisions or otherwise. Consultants have provided conflicting information T he insurer appointed building consultants ‘P’ to investigate the cause and extent of the damage to the garage ceiling. P attended and has provided a report of its findings dated 21 June 2021. P concluded that that there was no evidence of storm damage or water ingress to the garage ceiling. Rather, that the ceiling has initially sagged and ultimately partially collapsed because of a failure of the plaster adhesive due to age, wear and tear. P acknowledges in a later email dated 24 August 2021, that wind during the storm may have accelerated the inevitable being the collapse of the ceiling. However, the wind was not the cause for the damage, it was the failure of the adhesive. The insurer th en appointed plumbing consultant ‘J’ to attend the insured property. J has provided a report dated 24 June 2021. J did not find any issues that may have caused the collapse in the form of water ingress. J says the damage appears to be because of wear, tear and age causing failure of the ceiling plaster, which is common for houses of this age. The insurer sought opinion from structural engineers ‘AG’, whom have provided a report dated 16 September 2021. AG says ceilings installed in external garages experience harsher loading and conditions compared to internal ceilings. It notes the highest level of wind speeds during the June storm was 67km/hr. AG says correctly installed ceilings are designed to withstand much higher wind speeds. AG noted there was an absence of perimeter noggings, sarking and that the plaster had been installed in some areas with the use of adhesive only, contrary to the recommended 1/3 method. AG concludes the damage is consistent with age related wear and tear which has been accelerated by construction issues. The complainant appointed pluming consultant ‘RG’ to provide a report on the cause for the damage. RG found the garage to be well constructed and the ceiling well secured with glue and screws. RG says during the storm, which produced gale force winds, the wind has swept Determination | Case number: 836554 Page 3 of 5 between the roof tiles. The constant force of these winds and associated vibrations to the ceiling plaster has resulted in its collapse. The insurer is entitled to decline the claim Having considered the available information, I find the evidence from the insurer’s appointed consultants to be the more persuasive. I accept the information from the Bureau of Meteorology, obtained from the nearest weather station to the insured property, shows there were storm conditions in the few days before as well as the claimed date of loss (11 June 2021 – 52km/hr). This data shows there had been stronger wind speeds in the area in the months before the storm as well as the two days (67km/hr) before the ultimate collapse of the garage ceiling. The industry accepted Beaufort Wind scale categorises an event with wind speeds of between 63km/hr and 75km/hr as ‘Gale’, which on land is said to result in twigs breaking off trees and walking progress generally impeded. It is not expected to cause structural damage to buildings. There is no evidence of stormwater ingress into the garage ceiling cavity which could reasonably be said to have caused the failure of the ceiling plaster sheets nor is there evidence of any other storm related damage to the garage. The available photos do support the view that the adhesive applied between the ceiling plaster and timber framework has deteriorated over time and ultimately failed resulting in the collapse. I acknowledge AG refers to some minor contributing construction issues. However, I have not been provided with any evidence of the recommendations by the manufacturer of the plaster sheeting used for the garage ceiling nor the building standards relevant to the time of the garag e’s construction. It may be the case that the added steps/materials referred to by AG are recommended within the industry, but this does not make the constriction of the garage ceiling defective. Regardless, without persuasive evidence to the contrary, I am satisfied the insurer has shown, on balance, the sagging and subsequent partial collapse of the garage ceiling is because of the wear, tear and aging of the adhesive used to secure the plaster sheets. This is correctly assessed as gradual deterioration and wear and tear, which is excluded under the policy. The insurer is entitled to decline cover the cost to repair the damaged garage ceiling in line with the exclusions provisions provided in the PDS. Why is the outcome fair? The available information supports a finding that the damage to the garage ceiling is because of the aging and wear and tear of the ceilings adhesive over time and not the claimed storm. It is fair in all the circumstances to permit the insurer to rely on the policy provisions to assess and therefore refuse indemnity for the cost to repair the damaged ceiling under the claim. Determination | Case number: 836554 Page 4 of 5 3 Supporting information 3.1 The AFCA process AFCA’s approach is based on fairness AFCA has determined this complaint based on what is fair in all the circumstances, having regard to:  the legal principles  applicable industry codes or guidance  good industry practice  previous decisions of AFCA or its predecessor schemes (which are not binding). The respective parties have completed a full exchange of the relevant information, and each party has had the opportunity to address any issues raised. We have reviewed and considered all the information the parties have provided. While the parties have raised several issues in their submissions, we have restricted this determination to the issues that are relevant to the outcome. 3.2 Relevant information from the consultants’ reports Record Key points P Builders Report 21 June 2021  Inspection confirmed that the damage that exists has been caused by a breakdown of the ceiling plaster adhesive and general wear and tear  This has caused the plaster sheeting to sag and eventually collapse  No storm related damage noted with no water ingress J Plumber R eport 24 June 2021  Inspected roof space and roof of the garage and did not find any issues that may have caused water entry into the ceiling space causing the sagging to ceiling plaster  Appears to be wear and tear and failing of the ceiling plaster adhesive  This is a common occurrence with houses of this ag e AG Structural Engineer Report 16 September 2021  Garage constructed approximately 16 years ago  Ceilings installed in external garages are subjected to harsher loading and conditions compared to internal ceilings  Manufacturers of ceiling plaster sheeting specify additional requirements and recommendations to prevent the plaster from falling prematurely  BOM data from the nearest weather station to the insured property shows wind maximum wind speeds of 67km/hr during storm in June 2021  Correctly installed ce ilings are designed to resist wind gusts/speeds well above 67km/hr Determination | Case number: 836554 Page 5 of 5 Record Key points  No signs of moisture ingress in eastern half of the garage ceiling roof cavity, indicating the plaster had not collapsed because of the storm  AG noted: - there were no perimeter noggings - r equired for garage ceiling installations - there was no sarking installed in the roof cavity to reduce heat/moisture fluctuations - the plaster sheeting had not been fixed to the framing using the 1/3 method - the plaster sheeting had been fixed in areas to the framing using adhesive only  The plaster sheeting has failed due to age relat ed wear and tear. This deterioration had been accelerated by several minor contributing construction issues. RG Plumber Report 9 November 2021  Attended the property on 9 November 2021  Noted approximately ¾ of the plaster ceiling in the garage had collapsed  Roof is a tiled pitched roof built out of hardwood with hardwood ceiling joists at 450mm centres  Plaster has been well secured as it is evident from the glue and screws which are visible  Roof structure is well built, and the plaster ceiling had been adequately secured  RG concludes that during a storm whic h produced gale force wind, the wind has swept between the roof tiles  The constant force of the wind chattering betwe en the tiles has caused the ceiling to vibrate and subsequently collapse . 3.3 Relevant policy wording Exclusions to your cover We will not cover any loss or damage as a result of, or caused by: … • Erosion, rust, corrosion, gradual deterioration, depreciation, wear or tear … • A defect in an item, structural defects, or faulty workmanship or design.

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.