Claim declined for damage from leaking stormwater pipe; insurer reversed earlier acceptance
Text of the determination
Determination
Case number 834998
Financial firm Allianz Australia Insurance Limited
Determination | Case number: 834998 Page 1 of 14
Case number: 834998 9 August 2022
1 Determination overview
1.1 Complaint
The complainant holds a home and contents insurance policy with the financial firm (insurer).
A claim was lodged on 29 May 2020 for mould, dampness and cracking in the home. The
complainant advised the insurer of a blocked stormwater pipe. The insurer initially accepted
the claim and commenced restoration works in the home, along with further explorative
works. The insurer also provided alternative accommodation for the complainant.
On 27 May 2021, the insurer declined the claim on the basis the damage had occurred prior
to the policy inception. The insurer further relied on policy exclusions in declining the claim.
The complainant disputes the decision. The complainant is seeking the claim to be accepted.
He also wants the insurer to pay rectifications costs for the explorative works it conducted
along with the contents it removed. The complainant is also seeking further accommodation.
In addition, the complainant is dissatisfied with the handling of the claim and is seeking
compensation.
1.2 Issues and key findings
Is the insurer entitled to decline the claim?
No. The available information shows the complainant has established a valid claim. The
insurer has not shown it is entitled to apply an exclusion. This is because the panel accepts
the damage was caused by the leak and during the period of insurance.
Is the complainant entitled to non-financial loss?
Yes. The panel is satisfied the insurer has handled the claim unreasonably and this has
caused significant stress and inconvenience to the complainant. The insurer should pay
$5,400.
1.3 Determination
This determination is in favour of the complainant.
The insurer is to indemnify the complainant for this claim as set out in section 2.1.
The insurer should pay $5,400 in non-financial loss.
Determination | Case number: 834998 Page 2 of 14
2 Reasons for determination
2.1 Is the insurer entitled to decline the claim?
Complainant is required to establish a valid claim
The initial onus to establish a loss has been caused by an event covered by the policy rests
with the complainant. This is known as establishing a valid claim.
If the complainant can establish a valid claim, the burden shifts to the insurer to establish it is
entitled to decline the claim, if it seeks to do so.
The policy provides cover for accidental loss or accidental damage to the property, subject to
certain exclusions and conditions. The policy does not define accidental loss or accidental
damage. In the absence of a policy definition, accidental generally means something that is
unexpected and unintended.
Prior to the lodgement of the claim, the complainant had appointed his own plumber, OC. OC
reported there were several blockages, including one in the main stormwater pipe leading up
to the street. OC reported that due to the blockages, all rainwater from the roof had not been
exiting the property and ended up draining back under the house. The complainant engaged
a plumber (BM) to repair the stormwater pipe. Based on OC’s findings, the insurer says it
accepted the claim.
Leak was likely longstanding
The insurer first insured the property from 17 September 2018. On 29 May 2020, the
complainant contacted the insurer to lodge a claim for damage occurring on 8 May 2020. The
details of the claim lodgement show the complainant advised the insurer of:
Our stormwater drainage pipes under the driveway were original terracotta pipes.
For the past few years we have noticed "rising dampness" occuring in various
spots in our house. Some walls are damp/mouldy and there has been some
cracks appearing. Also the soil outside is very wet
The insurer appointed assessors (SE) to assess the damage. In its report dated 10 July 2020,
SE states the complainant had advised he had been experiencing dampness and minor
cracking with the property for the past two to three years.
In his submissions, the complainant says he had noticed a slight odour during this timeframe.
However, he had not registered any physical damage such as expanded composite timber
panels (due to moisture) or mould on any of the furniture or bedding. He had only noticed
minimum superficial discolouration on some walls and wardrobes.
Insurer’s engineering reports provid e conflicting opinions
The insurer is relying upon several reports provided by company IN. However, these reports
were written by different engineers who offered different opinions. Their reports have been
summarised in section 3.
The first report was provided by engineer PG dated 13 October 2020. PG took into
consideration OC’s report as well as a geotechnical engineering report done . PG concluded
that the issues predominantly affecting the property were water leaks taking place from the
Determination | Case number: 834998 Page 3 of 14
previous earthenware stormwater drainage system. This led to high moisture content of the
foundation soils, rising damp and high moisture in the walls. Whilst PG identified a large tree
on the site, he did not accept it would on its own change the existing condition on a normal
moisture regime. PG also concluded that certain areas of the home have been affected by
other factors, such as discharges from a hot water system and an air-conditioner, as well as
poor site drainage.
Subsequent reports were provided by engineer AS, who did not inspect the site. AS obtained
a further plumbing report which identified specific issues in the sewer and stormwater system.
This was after the complainant completed repairs to those systems. From this, AS came to
different conclusions. AS said the primary cause of the damage is tree-root drying effects
from the large tree. AS said poor site drainage, subfloor ventilation and stormwater
management are secondary contributors. Part of the factors AS relied upon were the fact
there was settlement identified (as opposed to heave). AS also considered this leak was long-
standing based on efflorescence in the subfloor and high moisture. In addition, AS said there
were weathered cracks.
Damage likely did not manifest until after the insurer came on risk
Based on all this, the panel notes the following.
The expert evidence is consistent in showing the leak was likely long-standing. Both PG and
AS agree on this. It is also consistent with the complainant’s initial claims description and the
fact he at least observed superficial discolouration on the walls and wardrobes.
The panel is not persuaded this caused damage before the insurer began insuring the
property on 17 September 2018. The complainant says physical damage did not become
apparent until closer to the claim date. His evidence is relatively consistent with the claim
lodgement where he said he noticed rising damp and ‘ there has been some cracks
appearing’. This statement indicates cracks appeared later down the track. At the least, this
statement is not inconsistent with his current evidence.
Whilst SE’s report indicated both the rising dampness and cracking occurred in the last few
years, it is not clear if the loss adjuster misunderstood the complainant’s reference to the two
as occurring at the same time.
Given the nature of damage identified, it appears unlikely this physical damage had
manifested for such a long period and remained unactioned. The panel considers it likely that
whilst rising damp was occurring, the damage being claimed only manifested closer to the
claim date. At the least, the panel is persuaded this damage likely occurred after 17
September 2018.
AS says he noticed cracks being weathered. This was not observed by PG who had
physically inspected the site. None of the photos show this. The panel is not persuaded by
this observation.
PG’s evidence is more persuasive
Regarding the expert evidence, the panel notes the following.
PG’s evidence is more persuasive. PG physically inspected the site and took this into
consideration as well as the geotechnical engineer’s findings. PG noted the moisture in the
foundation was likely caused by the long-standing leak. PG did not say this damage would
have occurred because of the large tree alone. Instead, PG noted the increased moisture in
the foundation likely resulted in the tree’s greater influence on the property.
Determination | Case number: 834998 Page 4 of 14
AS’s conclusion that the tree is the primary cause is inconsistent with the fact there is no
evidence this was causing such damage before the long- standing leak. Further, AS’s
observation that settlement is occurring in the foundation is consistent with the fact the leak is
long-standing and during this time, the tree was playing a greater drying influence on the
property . This is consistent with PG’s observations.
The panel notes that PG and AS both considered discharge from the hot-water system and
air-conditioner has been causing, or contributing, to the damage. However, the panel notes
the complainant says these were installed after the claim. Neither the experts, nor the insurer,
has addressed this. The panel is therefore not persuaded by their conclusion on these points.
One of the reasons AS came to a different conclusion was because he considered the initial
plumbing findings were vague. The panel disagrees with this. It was clear the property’s
foundation had been affected by long-standing leaks. This was substantiated by the
geotechnical report. The later plumbing findings did not refute this important consideration.
Further, and of significance, the second plumber tested the systems after substantial works
were done by the complainant’s plumber. It is unclear, to what extent, they represented the
leaks that were evident before the claim was lodged. Therefore, it is unclear how reliable that
report represented the leaks affecting the property.
Complainant has established a valid claim
Accordingly, after careful consideration of all the available information, the panel finds the
following.
The panel accepts the complainant’s evidence that the damage occurred during the period of
insurance. The panel also accepts this was accidental as there is no dispute the damage was
unintended and unexpected from the complainant’s perspective .
The panel is persuaded the long-standing leak was the likely dominant cause of damage. In
this regard, the panel finds PG’s evidence is persuasive. It is also consistent with the fact that
if the large tree was dominant cause of damage, then the home would have been sustaining
foundational damage for much longer than it has.
From this, it follows that most of the exclusions relied upon by the insurer do not apply. This
includes damage caused by tree roots, atmospheric conditions or settling or shrinkage of
earth. This is because the panel is persuaded the leak is the dominant cause of damage.
The panel notes this exclusion has also been raised by the insurer:
We will not pay claims for loss, damage or liability arising from: … Any event that
does not occur within the period of insurance
This is because the available information shows the leak was longstanding for at least several
years and probably started before the insurer came on risk.
However, the panel notes the following.
The pipe has been continually leaking every time there is a storm. Whilst it may have first
begun to leak before the insurer came on risk, it is clear it would have continued to do so
afterwards. Further, accepting the complainant’s evidence that the physical damage only
manifested a few months before the claim, then the exclusion would only apply if the
information shows the dominant cause of this damage was the pipe leaking before the insurer
came on risk.
Determination | Case number: 834998 Page 5 of 14
The panel does not accept this. The pipe would have been leaking for almost one a half years
before the damage manifested. It is realistically possible it was these leaks that caused the
damage, not before. At the least, the panel is not persuaded the available information shows,
on the balance of probabilities, that the leaks which occurred before the insurer came on risk
was the dominant cause of the loss being claimed.
Therefore, the panel not accept the exclusion is engaged.
Insurer must accept the claim
As the complainant has established a valid claim, and the panel is not persuaded the insurer
has shown it is entitled to rely on an exclusion, then the insurer is liable for this claim.
This means the insurer is required to indemnify the complainant both for the building damage
and the contents.
For the building damage, the insurer can elect to repair the damage or cash settle. If it cash
settles the claim, it should do so in this way:
engage an independent structural engineer to inspect the property and provide a full scope
of works for all the required repairs. The engineer’s costs are to be borne by the insurer.
once this engineer has completed the scope of works, the insurer is to obtain an actionable
quote based on these scope of works. This contractor should also provide an estimate as
to how long it would take to complete the repairs.
the insurer is to cash settle the claim based on this quotation with a 20% contingency. The
contingency is to address the fact the risks of the works are passing to the complainant
and the likely possibility that there may be variations required during the works.
If the parties are unable to agree on the quantum, the complainant can lodge a new complaint
at AFCA for a decision on this point.
For the complainant’s temporary accommodation, the panel does not consider it is fair for the
insurer to rely on the 12 month policy limit. This is because this claim has been significantly
delayed by the insurer’s conduct. Namely, the insurer decision to reverse its claims decision
in unfair circumstances and the flow on effects this has had.
The panel considers the 12 month limit is intended to apply when the costs have been
incurred due to the claim rather than the insurer’s conduct. In this case, the panel considers
the complainant’s temporary accommodation has been primarily caused by the insurer’s
unreasonable handling of the claim, not the claim itself.
Therefore, the complainant is entitled to temporary accommodation subject to the earliest of
the following:
when repairs are completed,
twelve months has passed since the complainant accepts this determination, or
if the insurer cash settles the claim, when the estimated period of time for repairs to be
completed has lapsed from when payment is issued
2.2 Is the complainant entitled to non-financial loss?
AFCA’s approach to non -financial loss
Under the AFCA Rules, we may award compensation (capped at $5,400) for non-financial
loss where a complainant has suffered an unusual degree or extent of physical
Determination | Case number: 834998 Page 6 of 14
inconvenience, time taken to resolve the situation or interference with their expectation of
enjoyment or peace of mind.
However, we adopt a conservative approach to the award of compensation for non-financial
loss. We expect complainants to be moderately robust and bear the usual stress and
inconvenience associated with an insurance claim.
Complainant dissatisfied with the handling of the claim
The complainant is dissatisfied with the insurer’s handling of the claim. The complainant
provided a timeline of the events during the claim. The panel notes the claim was lodged on
29 May 2020 and was then declined on 27 May 2021.
The complainant submits the insurer provided poor or no communication during the claim
process.
An award of compensation is warranted in the circumstances
The panel has considered all the available information. The information provided shows the
insurer initially accepted the claim and commenced works on the property (including removal
of contents). This acceptance was done on 16 July 2020 and not reversed until 27 May 2021.
Further, it appears the trigger for reversing this decision was the increasing cost of the claim.
In addition, the extensive works done by the insurer impacted the complainant’s ability to
mitigate his losses. For instance, the insurer disposed of a substantial amount of contents
and had done extensive works to the property such that it rendered the property
uninhabitable. This meant the complainant and his young family were forced into temporary
accommodation whilst attempting to dispute the insurer’s position on a f airly significant claim.
This claims handling is unreasonable and arguably a breach of the insurer’s duty of utmost
good faith. Further, it is plain this caused a substantial amount of stress and inconvenience.
Given this, the panel accepts the complainant is entitled to award of $5,400 for non-financial
loss for the stress and inconvenience experienced.
Determination | Case number: 834998 Page 7 of 14
3 Supporting information
3.1 AFCA process
AFCA’s approach is based on fairness
AFCA has determined this complaint based on what is fair in all the circumstances, having
regard to:
the legal principles
applicable industry codes or guidance
good industry practice
previous decisions of AFCA or its predecessor schemes (which are not binding).
The respective parties have completed a full exchange of the relevant information, and each
party has had the opportunity to address any issues raised. We have reviewed and
considered all of the information the parties have provided.
While the parties have raised a number of issues in their submissions, we have restricted this
determination to the issues that are relevant to the outcome.
A panel determined this matter
Due to the nature of this complaint, we referred it to a panel for determination. The panel
includes:
an ombudsman
a member with significant experience in consumer and small business advocacy
a member with extensive experience in general insurance.
We assess complaints on available information and circumstances
AFCA is not a court of law. We do not have the power to take or test evidence on oath, or to
require third parties to give evidence.
When we assess complaints, we consider:
available documents
the recollections of the parties
all relevant circumstances.
We give more weight to documents created at the time the events occurred. If there are no
relevant documents, we will decide what most likely occurred based on the available
information.
If there are conflicting recollections and these are evenly weighted, we may find that a claim
cannot be established.
Determination | Case number: 834998 Page 8 of 14
3.2 Relevant policy wording
Part A – Buildings and Contents – page 13
Accidental Damage cover
What is covered
Your buildings and/or your contents as set out in your schedule are covered if they are
destroyed loss or damaged. They are covered only if you own them or are liable for them.
…
We will cover your buildings and your contents for accidental loss or accidental damage….
What we will not pay for – page 15
We will not cover your buildings and your contents for any accidental loss or accidental loss
or accidental damage caused by:
Settling, shrinkage or any movement of earth;
…
Water entering your buildings:
- through an opening made for any building, renovation or repair work; or
- because of a structural defect, faulty design or faulty workmanship when your
buildings were constructed.
…
Roots from trees, plants, shrubs or grass;
…
A defect in an item, faulty workmanship, structural defects or faulty design;
…
What Parts A and B of the policy do not cover – page 46
What Parts A and B of the policy does not pay for loss, damage or liability arising from:
…
Mildew, atmospheric or climatic conditions;
Mould or fungi;
…
Any event that does not occur within the period of insurance; or
…
Determination | Case number: 834998 Page 9 of 14
3.3 Expert reports
Report Key points
Complainant ’s expert ( OC )
Plumber Report
14 June 2020
found several blockages including one in the main pipe leading to
the street.
the two downpipes on the northern side of the house were
connected under the driveway to the original earthenware pipes
leading to the street.
the main run of stormwater piping exiting the property was
completely blocked with soil and roots.
the old eart henware pipes had either moved, subsided or cracked
and therefore resulted in debris entering the pipes.
the other five downpipes on the east and south side of the house
were connected to the same original pipe underneath the
driveway.
therefore, all the water from the roof had not been exiting the
property and had hence ended up draining back under the house.
Insurer ’s expert ( IN )
Forensic Report
13 October 2020
a plumbing report has been provided, indicating that the
downpipes to the property’s roof were connected to an old
earthenware piping system that was broken and leaking.
the old earthenware piping system was replaced with new 100 mm
PVC piping, including new downpipes.
the system has been tested and is flowing adequately towards the
LPOD.
investigations support the plumbing report findings, that there is a
high moisture content towards the depths of the foundation soils,
indicating that there has been a substantial and longstanding
water leak affecting the building.
there is water ingress to the sub - floor space from other sources.
in bedroom 2, sub - floor clear evidence of wat er ingress from the
ventilation opening to the south - west corner of the room, including
dripping marks, excessive moisture to the footing wall’s brickwork
around the opening and water collection to the south footing
trench.
this water comes mainly from the HWS and A/C discharge pipes
through an area of recess to the concrete paving , to the south -
west of bedroom 2.
it is know n that both HWS and A/C can discharge up to 20 litres
per day, for a combined amount of up to 40 litres, which is
substantial enough to cause the water damage observed to
bedroom 2 sub - floor over time.
addition ally, it possible that surface water run - off is being directed
to the recessed conc rete area and accessing the subfloor from
there.
in the bedroom 1 subfloor, evidence was observed that there is
water ingress from the ventilation openings which are either
partially covered or flus hed with the exterior landscaping mulch.
Determination | Case number: 834998 Page 10 of 14
Report Key points
the extent of water ingress via the ventilation openings to bedroom
1 appears to be somewhat less than that leaked to bedroom 2
subfloor, it is the opinion, it is a contributory factor non etheless,
and it has at a minimum exacerbated wat er damage from ot her
sources.
the two boreholes completed to the exterior indicat e water
infiltration to depths that are not consistent with a short - term wat er
leak, therefore it is the opinion, that the am ount of moisture and
depth of infiltration correlat e to a long - standing water leak.
during a discussion with the homeowner, it was a concern that the
high moisture content to the south side of the building was due to
lack of sunlight.
it is acknowledged that this is a common belief, high moisture
content in buildings in primarily an issue related to poor ventilation
and not lack of sunlight.
in this case, the high moisture content in the walls is related rising
damp.
the high moisture content observed to the nort h - east corner of
bedroom 3 is not correlated to stormwater drainage leaks, as there
is no evidence ob served of substantial foundation movement on
that area.
during the site inspection it was observed that the A/C unit to the
e xterior of that area was discharging directly over the ground.
it is the opinion that the high moisture content on this area
correlated to the A.C unit discharge.
the sub - floor was investigated from a pre - existing floor opening in
bedroom 1.
the western footing wall presents efflorescence, normally
associated with rising damp due to high moisture content of the
surrounding ground.
the ground surface presents signs of efflorescence, correlated to
high ground moisture content.
based in evidenc e gathered, observations and tests carried out, it
is the professional opinion, that the building is currently in an
unstable condition, as it will continue to move along a recovery
process during the moisture normalisation of the foundation soils.
an app roximately 15m high tree has been noted in the review of
aerial imagery.
the southern areas of bedrooms 1 and 2 have been affected by
tree roof drying effect, however, it is the opinion, this effect has
stablished over time, and was likely stable long bef ore the
stormwat er leaks took place.
it appears that the tree has achieved full mature growt h, therefore,
there is no reason to believe that the effect that the tree is having
on the property on its own will change over time.
however, whilst the tree to the sout h of residence, has been
exerting a long - time effect and on its own should not change the
existing conditions (on a normal moisture regime), the conditions
Determination | Case number: 834998 Page 11 of 14
Report Key points
on the site are abnormal due to the high moisture content of the
foundation soils.
therefor e, after the remedial measures to prevent further water
leaks have been completed, it is expected that t he building will
enter int o a phase of foundation soil moisture normalisation,
meaning that the tree will start drying out the foundations soils
from so uth to north.
it is expected that this will be a gradual process that will take plac e
in a period of time, in our experience, to a minimum of 24 months.
during this period, the residence will experience different
movement and cracking could develop until it has reached stable
moisture conditions of the foundation soils.
the level to the north of the reside nc e are higher is relation to the
south.
this area was more affected by the stormwater drainage leaks per
the description in the plumbing report and t he homeowners’
account.
unfort unately, due to the north extent of the residence being
completely paved, it was not possible to carry out soil moisture
testing on that area; however, it is the report writers’ opinion, that
the northern extent of the reside nce is likely being affected by
some soil heaving due to the stormwater leaks.
there is a small approximately 2m high tree in the garden bed to
the west of bedroom 1.
due to the tree being small, it has not been the dominating factor in
the settlement ob served to the south of the residence, however, it
is the writer’s opinion that whilst this tree effect has not been
substantial, it has exacerbated the settlement observed to the
south of the residence, particularly to the extent directly adjacent
to the n ature strip where the tree is.
Insurer ’s expert ( IN )
Supplement ary Report
10 May 2021
given the building is founded on highly reactive clay soils, the
presence of increased levels of moisture in the soil would generate
volumetric expansion of soil.
as such, if the identified stormwater leaks on the southern side of
the building were causing damage to the subject building, would
expect see an increase in floor levels (heave) in the location of
leaks and cracking damage.
the results of the floor level survey, show reduced levels
(settlement) along the southern side of the building.
the settlement of the building is not consistent with the presence of
pipe leaks, but rather, is the result of tree - root drying effects from
the large tree in the L Street verge.
this tree is responsible for much of the building damage, as
removal of soil moisture has caused the soils to shrink and has
generated differential settlement movement of the footing system.
the punctured agricultural pipe on the sout hern side of the building
is located outside of the bedroom 2 and very near to the head of
Determination | Case number: 834998 Page 12 of 14
Report Key points
the agricultural drain.
as such it would not be expected to accommodate significant
stormwat er flows.
there is no evidence in the floor level survey to suggest this leak is
ha ving any effect on the building, and specially bedroom2.
bedroom 2 damage has been caus ed exclusively by tree - root
drying effects (tree in the street verge).
notwithstanding this additional plumbing investigation being
conducted and verifying the exact l ocation of a stormwat er leak(s),
given the leak rate is very small, at 2L per house, the leak would
be merely contributing (in a modest way) to increase levels of soil
moisture.
based on the evidence obtained, that the stormwater pipe leak(s)
on the south ern side of the building are not causing or cont ributing
to building damage.
the only region of the building which displays heave of the footing
system is the western end of the lounge room.
there exists stormwater pipework along the western side of the
building, in the vicinity of recorded heave.
there is also a silt pit which collects stormwater discharges from
agricultural drains on both the northern and southern sides of the
building, and which also connects to the main stormwater drain.
it is unclear how this drain performs under heavy rainfall
conditions, however, given that stormwater from the property is
connected to the subject sites’ stormwater system, and the silt pit
is downstream of this connection, it would be expected that the
e xisting stormwater system would be unable to servic e both sites ,
and excess stormwater would be released at the silt pit, effectively
making the silt pit, a surcharge pit.
in other words , excess stormwater would be expelled from the silt
pit on occasions when existing stormwater pipes could not process
stormwat er flows adequately and would thereby back - up and exit
the stormwater pipe network from the silt pit.
this hypothesis supports the presence of high soil moisture and
heave of the building at this l ocation, as previously demonstrated
by the obtained evidence.
poor stormwater management (design) is the proximate root cause
of the heave pres ent in the lounge room.
the mulched garden bed against the external wall of the lounge
room assists with moistu re retention and promotes heave.
there is no such evidence of heave recorded in or around the
bathroom, which is the area of the house located closes to the
sewer leak.
the identified sewer leak at the rear of the building is not causing
damage to the bu ilding.
the nature of the leak, which occurs at a junction between PVS
and earthenware piping is consistent with the assertion put forward
by the plumber, which is that the leak has been created from poor
Determination | Case number: 834998 Page 13 of 14
Report Key points
workmanship of the plumber who undertook the works .
the plumber did not test the condition of sewer pipework
suspended beneath the building, due to constraints with testing
apparatus and pipe size.
the conditions of these pipes remain unclear, however, based on
the recorded floor levels, there is no evi dence to suggest the
pipework is leaking or causing damage to the building.
whilst plumbing failures were identified at the site, both sewer and
stormwat er, there is no evidence to indicate these leaks are
causing damage to the subject building.
the roo t cause of identified plumbing leaks relate to poor
workmanship (sewer leak) at the rear of the building, poor design
(of the stormwater pipework on the southern side of the building),
and accidental damage (puncturing of the agric ultural drain with a
wood en stake).
the primary cause of damage to building is tree - root drying effects
from the nearby large tree, to the sout h of the building.
poor site drainage, subfloor ventilation and stormwater
management are considered secondary contributors to visible
b uilding damage.
Insurer ’s expert ( IN )
Supplement ary Report
19 May 2021
underpinning of a structure is undertaken where a structure has
settled considerably and/or foundation soils are not adequately
supporting the superstructure.
the settlement of the building has occurred and attributed to tree -
root drying effects, it is likely tree roots have extended into the
subject property where moisture was present, due in part, to
plumbing leaks.
considers the large tree in L Street to hav e present for many
years, and by extension, tree roots are expected to have extended
into the property and caused settlement damage to the building
many years ago (prior to policy inception).
if the narrative holds true that earthenware stormwater pipes w ere
leaking prior to June 2020 replacement, it is very likely that tree
roots extended towards this moisture source, which promoted
settlement of the building.
Insurer ’s expert ( IN )
Supplemen t ary Report
1 October 2021
there are several observations correlate with damage on a long -
term nature.
the presence of efflorescence (salt damp attach) typically occurs
over a prolonged period of time (years), and in combination with
abnormally high levels of moisture in foundatio n soils.
efflorescence was seen on the footing walls beneath bedroom 1
and bedroom 2.
the moisture levels in the soil (particularly at depth) are abnormally
high.
for this to occur, it is necessary for a leak to be occurring (and
seeping into soil) over a long period of time.
Determination | Case number: 834998 Page 14 of 14
Report Key points
weat hered crack profiles, which are discoloured, display rounded
edges, dust or webbing are all indic ators of long - term cracking
damage.