Home / IAG / Determination 830949
Determination 830949
Claim denied for garage ceiling collapse; insurer relied on gradual deterioration exclusion
Summary
The complainant claimed for a garage ceiling collapse he attributed to a storm, while the insurer denied the claim citing wear, faulty repairs, construction defects and poor maintenance. AFCA found the insurer entitled to deny the claim because the proximate cause was gradual deterioration, which the policy excludes.
Under proximate cause principles, the dominant cause of the ceiling collapse was gradual detachment of plasterboard, which is excluded as gradual deterioration under the policy.
Issues
- Claim denial primary · not upheld
“Yes. The insurer is entitled to deny the claim. Proximate cause was gradual detachment of the plasterboard, which is gradual deterioration excluded by the policy.”
- Inadequate claim investigation secondary · not upheld
“Insurer arranged two builders and a plumber to inspect; reports considered and insurer's position accepted on proximate cause analysis.”
Subjects and remedies
home or building damagenatural disasterno remedy
Text of the determination
Determination
Case number 830949
Financial firm Insurance Australia Limited
Determination | Case number: 830949 Page 1 of 7
Case number: 830949 16 February 2022
1 Determination overview
1.1 Complaint
The complainant lodged a claim with the financial firm (insurer) following the collapse of his
garage ceiling. The complainant says a storm caused the collapse.
It is unknown exactly when the ceiling collapsed as the complainant was on holiday between
3 July 2020 and 8 July 2020.
The insurer accepts there was a storm during this time however, it says this was not the
cause of the collapse. It says the cause of the collapse was long-term wear and tear,
previous faulty repairs, construction defects, and poor maintenance.
1.2 Issues and key findings
Is the insurer entitled to deny the claim?
Yes. The insurer is entitled to deny the claim.
Why is the outcome fair?
The outcome is fair because the insurer has shown, on balance, the proximate cause (see
3.2 below) of the damage was gradual deterioration. The policy does not cover gradual
deterioration and it is therefore fair for the insurer to be entitled to deny the claim.
1.3 Determination
This determination is in favour of the insurer.
The insurer is entitled to deny the claim and is not required to take any further action in
relation to the claim or complaint.
Determination | Case number: 830949 Page 2 of 7
2 Reasons for determination
2.1 Is the insurer entitled to deny the claim?
Yes. The insurer is entitled to deny the claim.
Complainant must show a valid claim
The complainant has the onus to show, on the balance of probabilities, a claim within the
terms of the policy. This is commonly called a valid ( prima facie ) claim. Once shown the onus
transfers to the insurer to show, on the balance of probabilities, it is entitled to:
rely upon a condition or an exclusion to refuse the claim
otherwise deny the claim.
The complainant’s policy provides cover for loss or damage caused by various events such
as storms and overflowing water.
The policy says:
Storm
We will cover you for loss or damage caused by:
• violent wind or thunderstorm (including a tornado or cyclone),
• heavy rain, hail or snow.
and
Bursting, leaking or overflowing
We will cover you for loss or damage caused by the sudden and unexpected
escape of liquid from:
• …
• …, gutters, guttering, …
In this case, to show a valid claim the complainant must show the garage ceiling collapse was
caused by a storm or overflowing water.
Insurer says cause of damage is excluded
The insurer accepts there was a storm in the area of the property around the timeframe when
the ceiling collapse occurred. However, the insurer says the ceiling collapse was not caused
by a storm or another insured cause.
Instead the insurer says the ceiling collapse was caused by long-term wear and tear,
previous faulty repairs, construction defects, and poor maintenance. It says these causes
are excluded by the policy.
The insurer has relied on the following general exclusions:
We will not pay for any loss, damage or liability arising directly or indirectly from or
in any way connected with any of the following:
Determination | Case number: 830949 Page 3 of 7
…
gradual deterioration, including wear and tear, rust, corrosion,
depreciation, fading or deterioration from exposure to light,
…
inherent or structural defects, faulty design or workmanship,
…
inadequate maintenance or failure to keep your home in good repair,
…
Insurer’s experts say ceiling collapse was not caused by a storm
The insurer arranged two builders and a plumber to inspect and report on the damage. There
are some inconsistencies between the three reports however, they all agree the cause of the
damage was not a storm.
The first builder (JP) says:
…garage ceiling has collapsed due to the failure of the fixings…
JP has not said why the fixings have failed however, it does say garage ceilings are exposed
to different wind pressures than normal ceilings. JP says the wind strengths recorded
between 3 and 8 July 2020 would not be enough to damage the ceiling.
The second builder (BB) says maintenance work is required to lead flashings on the roof. BB
has not said what caused ceiling collapse.
The plumber (TP) completed a roof report and identified water stains on the ceiling above the
garage door.
TP says the damage to the garage ceiling was the result of a hole in the lead flashing
combined with the flashing not being folded enough which allows wind driven rain in.
However, the section of ceiling where TP identified water stains did not collapse. This raises
doubt about if water entering through the roof was the cause of the ceiling collapse.
Complainant’s expert says collapse caused by water and gradual detachment
The complainant arranged for a builder (BS) to provide a report. BS says:
there are installation and maintenance issues at a Dutch gable at the front of the garage
roof, this could have allowed water entry however, it did not cause the ceiling collapse
because the ceiling is still attached underneath
the roof above the garage is in good overall condition
there are indications of substantial water ingress at the bottom of a valley near where it
intersects the Dutch gable, this could have contributed to the ceiling collapse
the tiles, valley, and lead flashing (around the valley) have no issues likely to cause water
ingress , it is possible the water ingress occurred during ‘extreme storm conditions’
water ingress has been a contributing factor to the ceiling collapse but is not the sole
cause
there are no plasterboard walls in the garage therefore the cornice would not have
adhered properly to the brickwork and timber
Determination | Case number: 830949 Page 4 of 7
the collapse of the ceiling has been due to a gradual detachment of the plasterboard
caused by variations in air pressure when the doors are opened on days of strong winds.
In summary BS has identified three possible causes of the ceiling collapse:
water entry at the bottom of a valley near the front of the roof
the cornice not adhering to the brickwork therefore adding weight to the ceiling instead of
supporting it
gradual detaching of the ceiling from variations in the air pressure.
Proximate cause of ceiling collapse is gradual detachment
When considering if claimed damage is covered under an insurance policy it is necessary to
consider what the proximate cause of the damage is. If the proximate cause is excluded from
cover, the insurer will generally be able to deny the claim.
As set out in 3.2 below, the proximate cause is not necessarily the first or the last or the sole
cause of the damage. It is the dominant or effective or operative cause.
BS says there is evidence of substantial water ingress and, while this may be a contributing
factor to the collapse, it says this is not the sole cause of the ceiling collapse. BS says:
…collapse of the ceiling has been due to a gradual detachment of the
plasterboard caused by variations in air pressure when the doors are opened on
days of strong winds…
Relevantly, while there is evidence of substantial water ingress it is not clear when this
happened, it is possible it did not happen during the storm and is old damage. It is also not
clear if the water ingress was capable of causing the ceiling to collapse in the absence of the
gradual detachment of the plasterboard identified by BS.
In this case, having considered the available information, I am satisfied, on balance, the
proximate cause of the ceiling collapse was the gradual detachment of the plasterboard. I am
satisfied the gradual detachment was caused by a combination of wind and the weight of the
cornices on the plasterboard.
Insurer is entitled to deny the claim
The gradual detachment is gradual deterioration.
Therefore, I am satisfied, on balance, the insurer has shown the damage was not caused by
a storm, overflowing gutter, or other insured cause and it was instead caused by gradual
deterioration. The policy excludes gradual deterioration.
Accordingly, the insurer is entitled to deny the claim.
2.2 Why is the outcome fair?
The outcome is fair because the insurer has shown, on balance, the proximate cause (see
3.2 below) of the damage was gradual deterioration. The policy does not cover gradual
deterioration and it is therefore fair for the insurer to be entitled to deny the claim.
Determination | Case number: 830949 Page 5 of 7
3 Supporting information
3.1 The AFCA process
AFCA’s approach is based on fairness
AFCA has determined this complaint based on what is fair in all the circumstances, having
regard to:
the legal principles
applicable industry codes or guidance
good industry practice
previous decisions of AFCA or its predecessor schemes (which are not binding).
The respective parties have completed a full exchange of the relevant information, and each
party has had the opportunity to address any issues raised. We have reviewed and
considered all of the information the parties have provided.
While the parties have raised a number of issues in their submissions, we have restricted this
determination to the issues that are relevant to the outcome.
We assess complaints on available information and circumstances
AFCA is not a court of law. We do not have the power to take or test evidence on oath, or to
require third parties to give evidence.
When we assess complaints, we consider:
available documents
the recollections of the parties
all relevant circumstances.
We give more weight to documents created at the time the events occurred. If there are no
relevant documents, we will decide what most likely occurred based on the available
information.
If there are conflicting recollections and these are evenly weighted, we may find that a claim
cannot be established.
3.2 Proximate cause
Case law establishes:
the proximate cause of loss is the dominant (or effective or operative) cause of the loss,
whether or not the cause is last in time or the sole cause
where several causes operate at the same time, each cause must be examined for the
qualities of reality, predominance and efficiency as the active, efficient cause that sets a
relevant chain of events in action
if one cause results in harm in any case, and the other would not in the absence of the
first, the first is the proximate cause
a common-sense approach is taken to determine proximate cause.
3.3 Complainant’s e xpert report (BS)
…
Determination | Case number: 830949 Page 6 of 7
Garage ceilings are notorious for collapsing. They are more susceptible to
collapse than other fully internal ceilings. See the excerpt below. This explains
how I believe garage ceilings can collapse. It is a general overview.
Garage ceiling collapse
Garage ceilings are more vulnerable to sagging and collapse than most other
ceilings.
This can be due to several reasons. The first is that the walls to most garages
are not always lined with plasterboard and the cornice adhesive does not stick
as well to timber or brickwork as it does to plasterboard. Because of this, the
cornice starts to detach from the non-plaster surfaces. This in time puts more
weight on the stud adhesive and screws across the rest of the ceiling. In any
case, the screws are only there to hold the ceiling in place until the stud
adhesive sets.
If any water ingress occurs in the ceiling from roof leaks or condensation, the
stud adhesive and plasterboard can start to soften and give way in those areas.
There is not usually any insulation in garages for obvious reasons therefore
water can flow easily across the top of the ceiling if major water ingress occurs.
Once detachment starts (For whatever reason), it puts more weight on the next
fixing and a domino effect takes place.
I believe that this process sometimes happens over an extended period and is
aided by the vibration from the garage door or in some cases, doors. If any
major water ingress occurs, sagging and/or collapse may happen more rapidly.
I also believe that the air pressure inside the garage can change drastically
when the large garage door/s are opened especially if there are strong winds
prevailing at the time. This can cause slight structural movement inside the
garage which can in time cause the ceiling to start to detach especially if the
ceiling is not installed to the absolute best standards. Plasterboard fixed to
battens will absorb more movement than if fixed directly to the bottom-chord of
the trusses. This damage often (but not always) occurs to the front section of the
garage ceiling which is usually adjacent to the main door/s.
…
Area 5
There has been some water ingress in this area. The bottom of a valley where it
intersects a Dutch gable is a common area where water ingress occurs.
There is evidence of some water ingress in the form of staining to the underside
of the valley boards.
There is also water staining on the underside of the truss below the lower end of
the valley.
This indicates that the water ingress has been substantial, and I believe it could
have contributed to the ceiling collapse. The ceiling plasterboard has been
removed from site therefore not all the evidence was available to me during my
inspection. On inspection of the tiles, valley, and lead flashing, I found no issues
likely to cause water ingress. I do not know if tiles had slipped down and been
pushed back in place since the original claimed storm event. Another possibility is
that water ingress has occurred during extreme storm conditions. The Owner of
Determination | Case number: 830949 Page 7 of 7
the property informed me that the ceiling collapse had appeared to emanate from
this area.
Conclusion
I believe that the water ingress has been a contributing factor to the ceiling
collapse but is not the sole cause. There are no plasterboard walls in the garage
therefore the cornice would not have adhered properly to the brickwork and
timber. As mentioned in the excerpt, this means that the cornice adds weight to
the edges of the ceiling instead of supporting it. In my professional opinion having
seen numerous similar scenarios, I believe that the collapse of the ceiling has
been due to a gradual detachment of the plasterboard caused by variations in air
pressure when the doors are opened on days of strong winds. Strong winds can
also exert huge pressures on roof structures which can create some minor
movement. I also believe that the water ingress at the lower end of the valley may
have been a contributing factor to the ceiling collapse.
Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.