Home / Hollard / Determination 811775
Determination 811775
Landlord accidental damage claim for subfloor and foundation pier damage partly declined
Summary
The complainant's landlord policy claim for a burst hot water system and resulting subfloor and foundation damage was partly declined as pre-existing and excluded. AFCA found the leak contributed to the loss and ordered the insurer to pay $13,000 less any excess.
Damage occurring within 72 hours of an escape of liquid from a fixed pipe or tank is covered, but pre-existing and structural damage predating the policy is not, so the insurer contributes a fair share of 25%.
Issues
- Claim denial primary · upheld“The insurer is not liable for the pre-existing damage or any damage that might be attributable to a structural defect.”
- Claim amount dispute secondary · upheld“In the absence of a clear breakdown of the damage attributable to the burst hot water system... I consider it fair that the insurers liability... be limited $13,000”
- Inadequate claim investigation secondary · not upheld“The insurer is entitled to rely on its expert evidence and the policy terms.”
Subjects and remedies
home or building damagemotor vehicle collisionpay claim
Related
Text of the determination
Determination
Case number 811775
Financial firm The Hollard Insurance Company Pty Ltd
Determination | Case number: 811775 Page 1 of 7
Case number: 811775 16 March 2022
1 Determination overview
1.1 Complaint
The complainant purchased a rental property in December 2020 and took out a Landlord
Accidental Damage Policy on the property with the financial firm (the insurer) on 18 February
2021.
On 4 March 2021 the complainant lodged a claim after discovering a burst hot water system
had saturated the subfloor of the property. The complainant says this caused the foundation
piers to move and mould damage.
The insurer accepted the resultant mould damage under the insurance policy but denied the
claim for damage caused by the movement of the foundation piers and says:
the damage is pre-existing and predates the policy period
the foundation piers were damaged due to long term issues and factors specifically
excluded under the insurance policy.
The complainant says the proximate cause of the damage is the escape of liquid from the hot
water system saturating the subfloor sometime after 18 February 2021 of which he was
unaware, therefore the policy should respond to the loss claimed.
1.2 Issues and key findings
Has the complainant established a claim that falls within the terms of cover?
Yes. The policy covers damage caused by earth movement and subsidence within 72 hours
of the escape of liquid. I accept some earth movement and subsidence most likely occurred
within 72 hours of the burst hot water system saturating the subfloor area.
Is the insurer entitled to limit its liability?
Yes. Given the available information not all the damage occurred after inception of the policy.
It is fair that the insurer limits its liability to $13,000 being 25% of the damage claimed
Why is the outcome fair?
The insurer is entitled to rely on its expert evidence and the policy terms. The information
shows, on balance, some of the damage occurred due to water leak from the hot water
system, consequently, it is fair the insurer contributes to the loss.
1.3 Determination
This determination is partially in favour of the complainant.
Within 21 days of the complainant’s acceptance of this determination the insurer is required to
pay the complainant $13,000 less any applicable excess in settlement of the claim for
damage arising from the leaking hot water system.
Determination | Case number: 811775 Page 2 of 7
2 Reasons for determination
2.1 Has the complainant established a claim that falls within
the terms of cover?
Yes. The policy covers damage caused by earth movement and subsidence within 72 hours
of the escape of liquid. I accept some earth movement and subsidence most likely occurred
within 72 hours of the burst hot water system saturating the subfloor area.
Complainant has initial onus to establish a valid claim
It is established insurance law that an insured bears the initial onus to prove, on the balance
of probabilities (that is more likely than not) that the loss or damage claimed falls within the
terms of the policy. This is commonly known as a prima facie or valid claim.
The complainant ’s policy is a Landlords Accidental Damage policy that provide s policy,
providing cover for accidental loss or damage to building and contents during the period of
insurance subject to several terms and conditions. The policy does not define accidental loss
or damage. AFCA considered the Macquarie dictionary meaning which states accidental ‘is
happening by chance or accident, or unexpectedly’.
The complainant says the hot water system was found leaking water onto the subfloor below
one of the bedrooms (bedroom 1) around 3 March 2021 and this caused the foundation piers
to move.
The policy limits cover for damage arising from erosion, subsidence, landslide or earth
movement to loss or damage that occurs within 72 hours of, and as a direct result of, erosion,
subsidence, landslide or earth movement directly caused by:
Storm, storm surge, Flood, rainwater, hail, snow, wind, tornado or cyclone;
Earthquake, subterranean fire, volcanic eruption or tsunami;
Explosion; or
Liquid escaping from a fixed pipe or something attached to a pipe, fixed gutter, fixed tank
apparatus or a drain.
Cover under the policy commenced from 18 February 2021. The onus is therefore on the
complainant to prove that most likely damage to the foundations occurred within 72 hours of
the hot water system leak.
Leaking hot water system saturated the subfloor.
The insurer’s plumber (S) inspected the property on 13 March 2021 and 23 March 2021 and
says:
the hot water cylinder burst. Water would have been constantly leaking from the hot water
service to the subfloor
there is a very strong possibility that the water from the hot water system caused mould to
develop
the area would have been completely saturated and part of the damage to the subfloor has
been caused by water leaking from the hot water service.
The insurer accepts the hot water system leaked water and caused mould damage to the
subfloor.
Determination | Case number: 811775 Page 3 of 7
Information provided by the complainant including pre-inspection reports while identifying
some subfloor foundation movement was likely to be pre-existing indicates as at 18 February
2021 the hot water system had not burst and the subfloor was dry.
According to the information, a property inspection on 18 February 2021 indicated the
subfloor was dry and there was no sign of a leaking hot water system.
Complainant has established a prima facie claim
Neither party was a witness to the claimed event. The property was unoccupied at the time of
loss. I accept the damage was unexpected from the compl ainant’s point of view as the leak
was only known around 3 March 2021. The leak was identified by the complainant’s property
consultants MCP.
The leak most likely occurred sometime between 18 February 2021 and 3 March 2021. The
insurers plumber S considered part of the damage to the subfloor has been caused by water
leaking from the hot water service. In the absence of information to establish exactly when the
hot water system burst I consider it fair in the circumstances to accept the subfloor damage
caused by the leak occurred within 72 hours of the water escaping the hot water system.
I accept the complainant has established a valid claim. Accordingly, the onus shifts to the
insurer to establish, on balance, the application of a policy exclusion or that it is otherwise
entitled to decline the claim under the policy.
2.2 Is the insurer entitled to limit its liability?
Yes. Given the available information not all the damage occurred after inception of the policy.
It is fair that the insurer limits its liability to $13,000 being 25% of the damage claimed
The insurer says damage pre-existing and caused by long term issues.
The insurer appointed builder (A) and engineer (I) to assess the loss. Based on their findings,
the insurer says the proximate cause of foundation movement is not the escape of liquid
(from the hot water system), but rather due to long-term issues.
In summary, the insurer says the damage:
is not because of an insured event
is not a direct result of one-off water leak event
pre-dates policy cover
is due to building defects (poor surface drainage and uncapped water drainpipe)
is due to subsidence unrelated to the hot water system
is excluded under the insurance policy.
Property had some pre-existing issues
The property had some pre-existing issues including cracks in pipework which would allow
water leakage into the subfloor and wet the reactive soil. There is also information to show
internally the building had some hairline cracks and gaps indicating some ground movement.
The complainant purchased the property on 19 February 2021 and engaged a building
inspector (Y), a plumber (H) and an electrician to complete a pre-purchase inspection report.
Y’s report dated 16 December 2020, notes:
the land is relatively flat
the site appears to be well drained
Determination | Case number: 811775 Page 4 of 7
there are gaps in floor at entry
water damage to subfloor was observed
hairline cracks evident to ceiling lining and walls.
In a report dated 16 December 2020, H says:
tree roots were in the stormwater pipe and recommended to clean it out
the elbow from the toilet is cracked
the earthenware in ground near the boundary trap is cracked. It is recommended to dig up
and replace with PVC (pipe).
The insurer’s builder (A) says the damage is consistent with long-term factors such as age,
wear and tear and soil settlement/movement.
The insurer’s engineer (I), reported:
the PVC stormwater drain connects to an earthenware/vitreous clay pipe adjacent to the
Eastern side of the hot water system and is not sealed
there is no immediate observable distress cracking to the wall and ceiling plaster within
Bedrooms 1, 2, 3 and living and dining rooms
there is distress cracking to the kitchen
there is evidence of subfloor saturation along the North elevation and efflorescence to the
subfloor soils indicating long term saturation
the subfloor area has an ongoing long-term issue from two separate sources, poor surface
water drainage and an uncapped storm water drainpipe
any water flowing into the subfloor regardless of the source would not be able to escape
the soils as the subfloor is at a lower level to the adjacent exterior perimeter surfaces
(soils, garden beds and driveway) creating a swimming pool effect
there is a significant variation in floor levels throughout the entire dwelling with the greatest
variation away from the claimed Hot water system leak event
given the highly reactive soils at the site, significant cracking to the brittle internal plaster
finishes would have expected, however the there was only slight vertical cracking to the
North East corner wall of the family room which is well away from the claimed leak.
without water bills, the observed subfloor saturation is not exclusively from a single one off
defined event such as a claimed leak from the hot water system.
I accept given the expert reports that some of the damage claimed was likely pre-existing.
Insurer not liable for pre-existing damage
The complainant says the insurer’s acceptance of the mould damage sets a precedence,
meaning the insurer is liable to accept the damage to the foundation piers in full.
The insurer is entitled to assess each loss for its own merits. The insurer has correctly
accepted the mould damage as it is likely due to the escape of water from the hot water
system.
The engineer (I) says the distress to dwelling, which was limited to slight damage to kitchen
and family has not been caused by the claimed leak event. Whilst , I appreciate the engineer’s
view, he has not provided sufficient evidence to demonstrate the water leak did not contribute
to the foundation movement. The insurer’s plumber (S) says the water leak from the hot water
system is a contributing factor to foundation movement.
I am satisfied, based on the expert evidence provided that the damage to the home occurred
because of two separate causes that were not concurrent.
Determination | Case number: 811775 Page 5 of 7
I agree factors such as building defects significantly contributed to the foundation movement
prior to the purchase of the property and commencement of the insurance policy. This is
supported by the information from the pre-inspection reports. I accept the information
establishes that most likely there was damage to the property pre-dating the policy which was
incepted on 18 February 2021. The insurer is not liable for the pre-existing damage.
I also accept that the hot water system having burst during the insurance period saturating
the subfloor area has further damaged the foundations and contributed to the damage to the
home.
Fair in the circumstances the insurer contributes to the cost of repairs
In resolution of the claim and the complaint, the complainant is seeking $52,000 for repairs to
the foundation piers and mould remedial works. The insurer has agreed to pay $2,000 for the
mould damage.
The quote provided from MCP, the complainant’s property consultant is for $50,000 and
refers to the restumping of the home but is not itemised. The quote is excessive if it is only for
releveling the home. The complainant’s representative confirmed in discussions on 15 March
2022 that it was for the full repairs.
The complainant also provided an itemised list of repair costs with an estimated cost of
$18,070 and an actual cost incurred of $12,405. The repair costs do not include restumping
but do include other works around the house that are in preparation for re-letting the property.
The list does not relate to damage caused by the leaking hot water service.
I accept the insurer is not liable for the pre-existing damage or any damage that might be
attributable to a structural defect. The pre-inspection report reveals issues with the subfloor
area and likely foundation movement given the hairline cracks observed. The insurer is not
liable for this damage.
In the absence of a clear breakdown of the damage attributable to the burst hot water system
or an itemised quote, I consider it fair that the insurers liability for the building repairs and
mould remediation be limited $13,000 being 25% of the complainants claim. I have reached
this view taking into consideration the various reports indicate limited internal damage and the
foundation saturation from the leak largely limited to an area under bedroom 1.
The policy provides for an excess on building claims of $500. It is unclear if the complainant
has already paid the excess. The insurer is entitled to deduct any applicable excess from the
settlement of $13,000.
2.3 Why is the outcome fair?
The insurer is entitled to rely on its expert evidence and the policy terms. The information
shows, some of the damage occurred due to excluded factors, however, on balance the water
leak from the hot water system likely contributed to the loss, consequently, it is fair the insurer
contributes to the claim.
Determination | Case number: 811775 Page 6 of 7
3 Supporting information
3.1 The AFCA process
AFCA’s approach is based on fairness
AFCA has determined this complaint based on what is fair in all the circumstances, having
regard to:
the legal principles
applicable industry codes or guidance
good industry practice
previous decisions of AFCA or its predecessor schemes (which are not binding).
The respective parties have completed a full exchange of the relevant information, and each
party has had the opportunity to address any issues raised. We have reviewed and
considered all the information the parties have provided.
While the parties have raised several issues in their submissions, we have restricted this
determination to the issues that are relevant to the outcome.
3.2 Relevant consultants’ information
Record Key points
Builder’s report (A) Attended site on 11 March 2021
The floor levels to the rear rooms of the residence were uneven
across all rooms
There were large gaps between the skirting board and the floor in th
Living room, as well as large gap where a breakfast bench is falling away
from a wall.
Damage was consistent with having been caused by age, wear and
tear, and soil settlement/movement to be confirmed by Engineer’s Report .
Engineer’s report (I) Attended site on 12 March 2021
The natural topograp hy of the land has no change in gradient and fo
all intents and purposes is considered flat.
The perimeter landscaping consisted mostly of a mix of uncapped
soils and garden beds to the West and South elevations of the dwelling
whilst the North and East elevations are capped with impermeable
pavements
The impermeable concrete pavement adjacent to the Northern
elevation of the dwelling was graded toward the footings of the dwelling.
As the pavement is graded toward the dwelling rather than away as
requir ed by the National Construction Code, liquids from rain events would
be directed to the subfloor area of the dwelling.
The PVC stormwater drain connects to an earthenware/vitreous clay
pipe adjacent to the Eastern side of the hot water system and is not s ealed.
There i s no immediate observable distress cracking to the wall and
ceiling plaster within Bedrooms 1, 2, 3 and living and dining rooms.
There is distress cracking to the kitchen
Determination | Case number: 811775 Page 7 of 7
Record Key points
There i s evidence of subfloor saturation along the North elevation
and efflorescence to the subfloor soils indicating long term
The subfloor area has had an ongoing long - term issue from two
separate sources, poor surface water drainage and an uncapped storm
water drainpipe.
Without water bills, the engineer concludes the obs erved subfloor
saturation is not exclusively from a single one off defined event such as a
claimed leak from the hot water system.
There is a significant variation in floor levels throughout the entire
dwelling with the greatest variation away from the cla imed Hot water system
leak event.
Given the highly reactive soils at the site, significant cracking to the
brittle internal plaster finishes would have expected, however the there was
only slight vertical cracking to the North East corner wall of the fami ly room
which is well away from the claimed leak.
Plumber’s reports (S) Attended site on 13 and 23 March 2021
CCTV inspection of the sewer and storm water lines were conducted
Just before the legal point of discharge, the stormwater line is
blocked which would back up and overflow from several stormwater point
around the property whenever it rains
the downpipe on the rear shed does not connect to a drain and is
discharging the water straight onto the ground
there is also an open - ended pipe, due to th is, water can leak straigh
out of the end of this pipe and spread along the rear of the house.
there is a broken bend on the right side of the property, as a result
waste water is seeping out from the crack in the bend and is spreading alon
the right sid e of the house.
When the hot water serviced was turned on, water started pouring
out from the cylinder
It appears that the cylinder has burst, and water have been
constantly leaking from the hot water service, which then would have easily
run straight und erneath the property
There are signs of mould right across the subfloor
There is a very strong possibility that the water which has been
leaking from the hot water service has caused part of this mould to develop
The area is completely saturated due to th e leak.
Part of the damage to the subfloor has been caused by water leaking
from the hot water service.
3.3 Other relevant material considered and relied on
Parties’ submissions/emails and all attachments to all submissions/emails
Pre-purchase inspection report