Home / IAG / Determination 810734

Determination 810734

Claim denial for retaining wall damage

FirmIAG
Decided2022-03-28
ProductGeneral Insurance · Home building and contents
OutcomeFor the firm
Amount awarded—
Non-financial loss—
Amount claimed—
SourceAFCA PDF

Summary

The complainants claimed under home insurance for storm-related damage to a retaining wall. AFCA found the wall failed due to defective construction, gradual deterioration and tree roots, which are excluded, and dismissed the complaint.

The proximate cause of the wall's failure was faulty design, gradual deterioration and tree roots, which the policy excludes, so the insurer was entitled to deny the claim.

Issues

Subjects and remedies

no remedy

Related

All IAG determinations · Find similar determinations

Text of the determination

Determination Case number 810734 Financial firm Insurance Australia Limited Determination | Case number: 810734 Page 1 of 6 Case number: 810734 28 March 2022 1 Determination overview 1.1 Complaint The complainants hold home and contents insurance with the financial firm (the insurer). On 11 November 2020, the complainants lodged a claim on the policy following damage to a retaining wall. They said the damage was caused by a storm on 31 October 2020. The insurer investigated the cause of the retaining wa ll’s failure. It concluded that the wall failed due to gradual deterioration, poor construction and tree encroachment. The insurer says damage from these causes is excluded from cover. The insurer has denied the claim. The complainants disagree with the insurer. They say the wall was in sound condition immediately prior to the storm. They refer to the statement by one of the insurer’s exper ts that the wall’s ‘failure may in part be attributable to recent rainfall…’ . They want the claim covered. The complainants are represented by their insurance broker, JH. For the sake of brevity, the complainants and JH are referred to in this determination as ‘the complainants’. 1.2 Issues and key findings Is the insurer entitled to deny the claim? Yes. The available information shows the proximate cause of th e retaining wall’s failure is poor construction techniques and gradual deterioration, not the storm. This means the insurer may rely on policy exclusions to deny the claim. The expert’s statement quoted by the complainants does not reflect that expert’s opinion. Why is the outcome fair? The outcome is fair because the insurer has established that the damage claimed is excluded from cover. It would not be fair for the insurer to have to pay the claim when the policy does not require it to do so. 1.3 Determination This determination is in favour of the insurer. The insurer is entitled to deny the claim. It is not required to take any further action. Determination | Case number: 810734 Page 2 of 6 2 Reasons for determination 2.1 Is the insurer entitled to deny the claim? Yes. The available information shows the proximate cause of t he retaining wall’s failure was poor construction techniques and gradual deterioration, not the storm. This means the insurer may rely on policy exclusions to deny the claim. Th e expert’s statement quoted by the complainants does not reflect that expert’s opinion. The complainants have established a valid claim under the policy The complainants are required to show, on the balance of probabilities, that they suffered a loss caused by a risk covered by the policy. This is known as a valid claim. The complainants hold a home and contents policy. The product disclosure statement and policy document (PDS) confirms that the policy provides cover for accidental loss or damage to the insured property. Relevant extracts of the PDS are set out in section 3.2 of this determination. For the purpose of the policy, retaining walls form part of insured buildings. It is not in dispute that the complainant’s retain ing wall has been damaged. There is no suggestion that the damage was caused intentionally. Accordingly, I am satisfied that the complainant has established a valid claim for accidental damage to the retaining wall. Once the complainant establishes a valid claim, the insurer is liable for the loss unless it shows an exclusion or limiting condition applies. The insurer has the onus of proof in establishing the application of the exclusion. The standard of proof is the balance of probabilities. The proximate cause of damage must be determined The insurer argues that the proximate cause of the damage is excluded from cover. Proximate cause is the dominant, efficient or operative cause of a loss. It is not required to be last in time or the sole cause. It is a question of fact that depends on the circumstances of each case. It requires a common sense evaluation of the evidence. The insurer relies on expert evidence After the claim was notified, the insurer appointed a builder (MC) to undertake an assessment of the damage. In its report dated 22 November 2020, MC concluded: I am of the opinion that a hollow core block wall to retain approximately 1.8m high build-up soil that is subject to seasonal movement would not be considered to be structurally adequate or of a sufficient design to retain the soil. I am of the opinion that this has occurred over a period of time and is not the result of a singular incident. It is not the result of storm activity. Determination | Case number: 810734 Page 3 of 6 As the complainant did not agree with the opinion of MC, the insurer obtained a building inspection report dated 21 December 2020 from CT, building consultants and engineers. The report included the following observations:  the retaining wall was constructed of concrete blocks without reinforcement, has no drainage and improper soil has been used as fill  two trees planted directly behind the retaining wall have pushed against the wall as they have grown, and contributed to its failure over time  lack of surface drainage and fill subsidence was causing water to pond behind the wall  the fill had been saturated many times over the years, increasing the loads on the wall and reducing soil strength  t he wall’s failure would continue to progress in the short and long term, likely exacerbated by future rainfall events and the ongoing effect of the trees. CT concluded: We are of the opinion that the retaining wall has failed due to Defective Building Work and Maintenance Related Issues and whilst failure may in part be attributable to recent rainfall events and rainfall Events over a period of years we are of the opinion that the failure of the retaining wall was inevitable and cannot be attributed to any single rainfall Event. CT provided supplementary reports dated 6 February 2021 and 12 March 2021, responding to a correction of the date of the storm, Bureau of Meteorology (BOM) records and the complainant’s submissions. CT confirmed that:  it maintained the view that defective building work and age deterioration over time attributable to the tree encroachments had caused the wall to crack and rotate  none of the damage was due to a storm event  it stood by the findings set out in its original report. Given its expert evidence, the insurer says that the proximate cause of the retaining wall’s failure is a combination of faulty design/structural defect, gradual deterioration and tree roots. Accordingly, it says it is entitled to rely on policy exclusions that preclude cover for damage from those causes. The complainants say that the storm must have caused the damage The complainants have not provided any expert evidence on what caused the retaining wall to fail. Nevertheless, they say the storm on 31 October 2020 must have been the proximate cause of the damage. In summary, they submit:  the retaining wall was in place for 40 years and was structurally sound until the storm  the complainants observed the wall the day before the storm and it was in sound condition  the storm was of sufficient intensity to shred an outdoor blind  their landscaper, SS, told them that: > he had seen similar cases of ‘rapid change in recent times after significant storm activity’ > the two trees near the wall are camelias. This species has a non-invasive root system and would not have caused damage to the wall.  t he insurer’s expert (CT) confirmed the wall’s ‘failure may in part be attributable to recent rainfall…’. Determination | Case number: 810734 Page 4 of 6 The complainants also say that the insurer and its experts had initially referred to the claim lodgement date as the date of loss and had quoted for a four metre wall repair when the wall is 10 metres long. They submit these errors ‘create doubt regarding the integrity, competence and accuracy in their assessment. ’ The insurer is entitled to deny the claim Having reviewed all of the information provided by both parties, I am satisfied that the insurer has on the balance of probabilities shown that the proximate cause of the damage is faulty design/structural defect, gradual deterioration and tree roots. This means the insurer is entitled to rely on policy exclusions to deny the claim. I acknowledge that the wall was in place for 40 years prior to the storm on 31 October 2020 and that a visual observation the day before did not suggest any problems with it. However, the available expert evidence is unequivocal – the wall was constructed without drainage or reinforcement; it has gradually deteriorated over time, particularly given the increasing pressure applied to it due to the growth of trees abutting it. I am unable to place much weight on the comments attributed to SS as there is nothing from SS to confirm the statements or setting out the context in which they were made. The complainants’ reliance on the statement by CT that the wall’s ‘failure may in part be attributable to recent rainfall…’ is misplaced. It does not accurately reflect C T’s opinion on causation which is maintained in its three reports. The shredding of the blind does not show that the consistent views of MC and CT on causation are wrong. I accept that there has been some confusion regarding the date of loss. That confusion appears to have been in part contributed to by the complainants (for example, the claim form recorded the wrong date). To the extent that CT’s first report commented on BOM data for the wrong days, that was rectified in its supplementary reports. While MC did provide an estimate of the cost of repairs that included replacement of 4 metres of the wall, it nevertheless recorded that the wall was 9.4 metres in length. Accordingly, I am not satisfied the opinions of MC and CT are based on inaccurate assessments. The insurer is entitled to deny the claim. It is not required to take any further action. 2.2 Why is the outcome fair? The outcome is fair because the insurer has established that the damage claimed is excluded from cover. It would not be fair for the insurer to have to pay the claim when the policy does not require it to do so. Determination | Case number: 810734 Page 5 of 6 3 Supporting information 3.1 The AFCA process AFCA’s approach is based on fairness AFCA has determined this complaint based on what is fair in all the circumstances, having regard to:  the legal principles  applicable industry codes or guidance  good industry practice  previous decisions of AFCA or its predecessor schemes (which are not binding). The respective parties have completed a full exchange of the relevant information, and each party has had the opportunity to address any issues raised. I have reviewed and considered all of the information the parties have provided. While the parties have raised a number of issues in their submissions, I have restricted this determination to the issues that are relevant to the outcome. We assess complaints on available information and circumstances AFCA is not a court of law. We do not have the power to take or test evidence on oath, or to require third parties to give evidence. When we assess complaints, we consider:  available documents  the recollections of the parties  all relevant circumstances. We give more weight to documents created at the time the events occurred. If there are no relevant documents, we will decide what most likely occurred based on the available information. If there are conflicting recollections and these are evenly weighted, we may find that a claim cannot be established. Determination | Case number: 810734 Page 6 of 6 3.2 PDS extracts Page 13 We will cover your buildings and your cont ents for accidental loss or accidental damage... Page 14 We will not cover your buildings and your contents for any accidental loss or accidental damage caus ed by: … • settling, shrinkage or any movement of eart h … • rust, corrosion, gradual deterioration, depreciation, wear or tear … • roots from trees, plants, shrubs or grass. –– however , this exclusion applies only for loss or damage caused directly by roots … • a defect in an item, faulty workmans hip, structural defects or faulty design

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.