Partial claim denial for subfloor, bathroom and bedroom damage; cash settlement of leak damage and temporary accommodation
Text of the determination
Determination
Case number 810508
Financial firm QBE Insurance (Australia) Limited
Determination | Case number: 810508 Page 2 of 25
Case number: 810508 6 June 2022
1 Determination overview
1.1 Complaint
The complainant and the co-insured hold a home and contents policy with the financial firm
(insurer). The policy includes cover for accidental loss or damage to building and contents.
For the sake of brevity and convenience, references to the complainant in this determination
include references to the co-insured.
In late April 2021, the complainant noticed damage to the timber flooring in the kitchen and
lodged a claim for the damage. The complainant says the damage was caused by a burst
kitchen pipe which leaked under the home in the previous month. The complainant also
claimed further damage was caused by storm water damage from rainfalls in March 2021 and
the insurer’s delay in finding the source of the leak
The insurer repaired the leak, assessed the damage and partially accepted the claim. The
insurer offered to pay $41,668.40 made up as follows:
building repairs - $29,788.17
contingency allowance (15%) - $4,468.23
temporary accommodation - $6,412.00 (28 days X $229/day)
non-financial loss compensation - $1,000
The insurer says the damage which is in dispute did not result from the leaking pipe. Rather, it
says that damage was present prior to the policy commencement and is due to factors which
are excluded under the policy.
The complainant disputes the insurer’s settlement offer. He says th e disputed damage resulted
from the leaking pipe. The complainant wants the insurer to repair all the claim related damage.
1.2 Issues and key findings
Is the insurer’s settlement offer fair and reasonable?
No. While some of the claimed damage probably occurred before the policy commenced, the
insurer’s settlement offer does not include all the damage caused by the leak. A fair outcome is
for the claim to be cash settled in the manner set out in the paragraph “cash settlement
mechanism described”.
The insurer is also required to pay temporary accommodation for the repair duration. This part
of the claim is to be settled in the manner set out in the paragraph “insurer required to pay
temporary accommodation”.
Is the insurer required to increase its non-financial loss compensation offer?
Yes. The insurer is required to pay $4,000 in non-financial loss compensation.
Why is the outcome fair?
The insurer is entitled to settle the claim based on its policy terms and expert opinion. As the
panel accepts the available information establishes much of the claimed damage was caused
Determination | Case number: 810508 Page 3 of 25
before the policy commenced, it would not be fair for the insurer to pay all the claimed damage.
As the claim is to be cash settled, it is fair the insurer makes adequate provision for
contingencies and variations which may occur once repairs commence.
1.3 Determination
This determination is partially in favour of the complainant.
Should the complainant accept this determination then within seven days of notification of
acceptance the insurer is to resolve the claim in the manner set out in the paragraphs “cash
settlement mechanism described” and “insurer required to pay temporary accommodation.”
The insurer is also to pay the complainant $4,000 non-financial loss compensation.
Determination | Case number: 810508 Page 4 of 25
2 Reasons for determination
2.1 Is the insurer’s offer fair and reasonable?
Circumstances surrounding the claim
The complainant’s policy is a home and contents policy. The policy commenced on 1 February
2021. The policy covers accidental loss or damage to both building and contents. The policy
also covers damage caused by storm and by water escaping from a fixed pipe.
The policy defines accidental as “unintended and unexpected”.
The policy is subject to exclusions.
Extracts from the policy are set out in supporting section 3.2 of this determination.
The complainant must establish on the balance of probabilities he has suffered a loss caused
by an event to which the policy responds. This is known as a prima facie or valid claim.
Once so established, the onus shifts to the insurer to prove on the balance of probabilities that
an exclusion applies if it seeks to deny or limit its liability for the loss.
On 29 April 2021, the complainant lodged a claim with the insurer after he noticed damage to
the timber flooring in the kitchen. In mid-April he said he noticed a lack of hot water pressure.
The insurer appointed a builder to undertake the make safe works in the kitchen.
The insurer appointed two builders (AB and AJ) to attend the property and assess the damage.
The builders noticed damage to the floorboards around the kitchen.
In early May 2021, AB undertook a leak detection test and found a leaking hot water pipe in the
subfloor (under the kitchen) which caused damage. The complainant was told to turn off the hot
water service except when using hot water.
The claim was accepted, and the insurer arranged repair quotes.
The insurer arranged another builder (CS) to undertake the repairs. CS formed a contract
which included a scope of work for repairs to the kitchen and lounge area. On 24 May 2021,
the complainant signed the contract for CS to undertake the repairs at the property.
Prior to CS starting the repairs, CS attended the property to ensure the scope of works was
accurate. During this assessment, CS noticed additional damage to the areas in the house
which were not part of its original scope of work.
CS provided numerous photographs of the resultant damage and the subfloor including the
water escaping from the hot water pipe.
Plumber described multiple factors contributing to the moisture in the subfloor
CS appointed a plumber (EC) to undertake a leak detection test. The leak in the kitchen was
repaired by the insurer which it says it was not obliged to do under the policy terms.
EC also undertook a leak detection test in the bathroom where it found no leaking pipes.
However, thermal flood testing was conducted and showed water escaping from the shower
screen to the floor through the tiled wall dividing the bathroom and entry leading to the
conclusion there was a failed membrane.
Determination | Case number: 810508 Page 5 of 25
EC noticed the floor waste in the bathroom was not connected to any drainage which resulted
in water draining straight to the subfloor. EC also found the floor tiles were flowing away from
the floor waste.
There is no dispute about the membrane failure and shower screen leaking.
Photographs under the house show water had escaped to the subfloor from the failed
membrane near the bathroom entry. Annotated photographs say stormwater is trapped to the
lowest point of the subfloor and cannot escape the subfloor.
Annotated photographs also say there is storm water entry to the subfloor through weep holes,
water trap to the footpath, wood rot in the subfloor, mould in subfloor dirt and timber flooring.
EC inspected the subfloor. He found mould in the dirt and the underside timber floor through
about 80% of the house. He found this was consistent with multiple water issues which had
occurred over time.
EC agreed the particle flooring in the kitchen was damaged consistent with the burst pipe
which would have “assisted to levels of moisture to the subfloor” but with minimal impact.
EC said the water which escaped from the main bathroom through the floor waste combined
with the failed membrane caused damage to the hallway entry of the bathroom and contributed
to moisture to the subfloor. This also elevated moisture in the adjoining bedroom.
EC reported weep holes to the high elevation of the house were found flush and lower than the
landscape allowing stormwater to flow into the subfloor during storms. EC found no subfloor
drainage to allow water to egress. Also, the subfloor perimeter is higher, and the stormwater
cannot escape.
EC provided an aerial image of the house indicating the flow of stormwater through the weep
holes at the side of the house (the side near the pool and garage) and circled the lowest
elevation of the subfloor which he says allowed stormwater to be trapped causing moisture to
transfer inside.
EC’s site plan describes the high levels of m oisture in the bedroom from water flowing from the
bathroom floor waste and the flow of water from the shower to the hallway. As for the dining
and lounge rooms, he notes the damaged floor skirtings and doors from the stormwater
moisture.
EC described the subfloor as a moisture trap causing mould to grow on the dirt and timber
which has transferred the high levels of moisture inside causing skirtings and doors to swell.
EC found extensive wood rot to bearers and joists mostly around the bathroom. One bearer
was propped which he said appears temporary. Because of the extent of wood rot, he
recommended a structural engineer be appointed.
Engineer and builder say the leak only caused localised damage
The complainant also claimed further damage was caused by storm water damage from
rainfalls in March 2021 and the insurer’s delay in finding the source of the leak.
The insurer arranged for a builder (JE) and engineer (PS) to provide an opinion.
A summary of the expert opinion is set out in supporting section 3.3 of this determination.
PS inspected and photographed the property on 18 June 2021 and concluded the following:
damage to the kitchen floor was caused by the hot water leak.
Determination | Case number: 810508 Page 6 of 25
water damaged timber framing under the kitchen was to be replaced but before that is done
the brick piers and timber supports are to be realigned.
his inspection showed a pattern of ground movement caused by surface water entering the
subfloor and ponding over time (annotated photographs of vents explain).
movement and subsequent subsidence was not caused by a single event but over time.
floorboard damage in other parts of the house is due to ground movement, lack of
foundations and age (an annotated photograph says no visible footing under brick piers).
damage to the subfloor, floor and bathroom is due to age, lack of property foundation, poor
maintenance, and long-term soil movement.
JE also inspected and photographed the property on 18 June 2021 and concluded:
damage to the kitchen cupboards joinery and damage to the flooring in the kitchen and
family room was due to the burst pipe and pre-existing extremely high levels of moisture in
the subfloor area.
detachment of the skirting boards in the living room (which backs on to the kitchen) is due to
the burst pipe.
damage to the floors in dining, lounge and hallway is due to pre-existing high levels of
moisture to the subfloor.
damage to the master bedroom and small bedroom next to the bathroom is due to pre-
existing high levels of moisture in the subfloor.
JE provided an extract from the1990 building code and several photographs including:
how some of the brick vents and a manhole are located at ground level allowing water to
enter and a gap between the paving and external brick work also allows water to enter.
one which was annotated to show the ground under the subfloor is graded to trap water at
the base of the brick wall where it ponds and soaks into the foundations.
floor framing and underside of the flooring showed mould (most of the house is like this).
an illegal timber strut.
Parties disagree on the cause and extent of damage
Based on these reports, the insurer accepted the damage to the kitchen cupboards and
joinery, the skirting board in the living room as well as the solid flooring in the kitchen and living
room was ca used by water damage from the burst water pipe.
Relying on policy exclusions, the insurer said the damage to the subfloor, footings, bathroom,
master bedroom, ensuite, hallway were excluded because of breaches of the building code
and that this claimed damage was due to long-term soil movement which pre-existed the
commencement of the policy on 1 February 2021. It says the subfloor damage is clearly long-
term as evidenced by mould and rot. It says water has been ponding under the house for many
years and identifies how water has entered the house.
The insurer said the water damage to the bathroom floor and wall tiles was also pre-existing
and unrelated to the leak in the kitchen.
These parts of the claim were therefore declined.
The insurer agreed to cover some repairs and prepared a scope of works. Initially it offered to
settle the claim by paying $38,880.12. Subsequently, it increased the offer to $41,668.40.
Parties’ submissions and material considered
The complainant has made many lengthy submissions and provided commentary on the
complainant’s expert reports. He says all damage to the kitchen, family, dining, living room,
Determination | Case number: 810508 Page 7 of 25
bathroom and master bedroom was caused by the burst hot water pipe, since the pipe was
located between the kitchen and dining room's shared wall.
Initially he indicated he would provide two reports: one from him and his wife who are both
engineers and the other from an independent engineer. No independent engineer report was
provided.
The complainant made many submissions but essentially, he argues the damage occurred
after the policy commenced and:
because the leak was not repaired quickly enough significant water flowed under the house
causing damage not only under the kitchen but in other areas where water has ponded
under the sub floor into reactive soil causing ground movement, cracking, and other
damage.
over 19 or 20 days, the hot water saturated the soil leading to settlement, hydrostatic
pressure and uneven ground movement which was not seen in the prepurchase property
report (June 2019) or in photographs taken in November 2016.
the insurer has not taken sufficient notice of the amount of hot water which leaked and the
June prepurchase report.
a “natural disaster flood event” occurred in March 2021 and water was also trapped under
the subfloor due to heavy rain which contributed to the damage.
any pre-existing damage has been made worse by the leak.
membrane failure, seepage through missing floor waste pipe and water ingress through
weep holes had minimum impact noting only three weep holes flush with ground level.
building codes relied on are irrelevant because the house was built in 1977.
The complainant says around 39,585 litres of water leaked through the ruptured pipe which
resulted in swelling and separation of skirting boards in the kitchen, dining, lounge and living
rooms. He says the flooring in the dining, lounge, master bedroom and hallway were damaged
by excessive moisture in the subfloor area due to the leaking pipe.
He provided the prepurchase report from 2019 which he says show there were no long-term
problems in the subfloor. A summary of the report is in supporting section 3.3 of this
determination.
The complainant also says cracks in the inner walls of the kitchen, dining and lounge rooms
started appearing after the initial attendance of PS and JE.
Furthermore, he says the scope of work should include costs to repair the joists and bearers,
mould remediation of the floor framing and replacement of the mouldy soil.
The complainant says the amount offered is unfair as it does not address all the claimed
damage. He obtained two different quotations to repair all claimed damage which includes
mould treatment, replacement of soil, and bearers and joists.
He also says the architrave, skirting, kitchen joinery and cabinets, as well as the kitchen island
bench tops, cannot be reused once removed from the kitchen and dining areas.
He referred to new cracking damage since PS and JE inspected. The insurer arranged further
inspections to address these concerns and the complainant’s submissions and information
provided. It said it would then prepare a final scope of works.
The insurer considered the prepurchase report but did not find it compelling because the extent
of the inspection was unclear. It considered the report was inadequate for the purposes of
Determination | Case number: 810508 Page 8 of 25
establishing the true condition of the subfloor in 2019. It notes reference to drainage issues
with rainwater coming through to the subfloor.
The complainant says he and his wife are both engineers. They inspected the property many
times prior to purchase and can rely on their professional expertise that it was safe and without
any major defects.
PS and JE provided for further reports which are summarised in supporting section 3.3 of this
determination.
Relying on those reports the insurer said the cracking is not related to the burst pipe but is an
ongoing problem caused by seasonal ground movement. It notes the long-term issues with the
foundations, drainage and cracking pre-date the policy inception on 1 February 2021.
It points out the complainant’s position is not supported by independent expert evidence.
The insurer provided a quotation based on an updated scope of works and made a final offer to
cash settle the claim for $41,668.40.
The complainant rejected the offer for many reasons including the quote is not an independent
quote because CS is in the insurer’s service agreement.
Analysis of submissions and material
Both PS and JE reported the ruptured pipe only caused localised damage in the kitchen,
lounge room and skirting in the dining room. Previous repairs to the living room floor and
cracks were noted which they say were indicative of historic movement.
The ruptured pipe is fixed to a brick wall in the subfloor and there is another brick wall which
separates the kitchen from the dining area in the subfloor. JE says the bulk of the water from
the ruptured pipe would have fallen between these two walls. JE says there is a low point at the
base of the second brick wall which means the water would need to travel uphill to reach the
living and dining area.
JE says water can rise through soil due to capillary action but only if all the soil below it is fully
saturated. Water will continue to flow downwards due to gravity. JE says for the soil to be so
saturated that additional water travels up rather than down effectively means the water table
would have raised locally. It says this would not have occurred due to the subject leak .
Both PS and JE say the other damage is due to high levels of moisture in the subfloor area
which has occurred over a long period of time. They say stormwater entering over the years
through weep holes and through the gap in the paving along with drainage issues in the
bathroom have all contributed to the subfloor moisture. Further, they say the subfloor is graded
in a manner where the moisture gets trapped in the soil and soaks in the foundations.
The complainant says the contribution of water ingress through the bathroom membrane failure
would have been minimal.
The insurer’s engineer and building consultant disagree with this contention. Essentially, both
experts say the damage in the other parts of the property apart from kitchen and family room is
due to ground movement which has happened over years.
Leak has caused damage in the dining and lounge room and cracking damage
The insurer accepts the damage to the skirting board in the dining room would have resulted
from the ruptured pipe. The insurer says the dining and lounge room flooring would not have
Determination | Case number: 810508 Page 9 of 25
been affected by the leak because the water spray would not have travelled that far. Further, it
says the moisture in the subfloor near this area would have been from the surface water runoff
through the ventilation openings (weep holes).
PS stated in its second report it appears as an impossible task for water to travel as far as the
dining room window. PS says there was evidence of previous repairs to many cracks.
Accordingly, it says the cracking does not appear to be related to the burst pipe but rather an
ongoing problem caused by seasonal ground movement.
The panel does not accept this reasoning. This is because part of the dining and lounge room
flooring is adjacent to the brick wall which was saturated by the water coming from the leak.
Thus, any potential water damage to it could, on balance, be attributed to the leak itself.
The insurer relies on explanations from PS as to alternative reasons on how damage in the
dining room flooring would have been affected. However, the panel notes weep holes which
are sitting flush to the ground are on the opposite side of the building, from the dining room.
The insurer has not provided an explanation about how the water would have travelled from
the weep holes to the subfloor area of the dining and lounge room.
The complainant says the cracks in the walls of the kitchen, dining, and lounge areas is
evidence of ongoing ground movement caused by hydrostatic pressure exerted on the subfloor
due to the subject leak. These cracks were not present during the initial attendance of both PS
and JE in June 2021.
PS reported it appears as an impossible task for water to travel as far as the dining room
window and hence cannot be the cause of the leak by the hot water system.
The panel accepts, on balance, it is plausible for these cracks to have developed after PS’s
initial attendance due to the saturation of the soil from the leak resulting in cracks in the internal
walls near the family room, kitchen, lounge and dining areas.
Accordingly, the panel is satisfied the flooring in the dining and lounge room along with the wall
cracks in the family room, kitchen, dining and lounge rooms have been caused by the water
leak from the hot water pipe.
Other claimed damage not caused by the leak
The complainant says damage in the master bedroom, hallway, bathroom, timber framing and
mouldy soil in the subfloor is due to the leaking pipe. The panel is not satisfied the damage in
the master bedroom, hallway, bathroom and subfloor area, which was not near the ruptured
pipe, is due to the subject leak. Further, the panel does not accept mould in the soil is due to
the subject leak. The panel considers the insured damage is confined to the family room,
kitchen, dining and lounge rooms.
In reaching this view, the panel considers:
the master bedroom is not in the vicinity of the leaking pipe.
weep holes which are sitting flush on the ground are adjacent to the master bedroom.
EC’s report shows moisture in the master bedroom and adjacent bedroom resulted from the
shower screen leak and failed membrane and inadequate drainage in the bathroom.
EC’s report shows the leak from the main bathroom and membrane failure has flowed
towards the hallway entry causing damage to the flooring.
rot on the underside of the timber framing, joists and bearers in these areas appears old.
the subfloor is graded in a manner where the moisture gets trapped in the soil and on
balance, resulted in mouldy soil over a period of time.
Determination | Case number: 810508 Page 10 of 25
the subfloor grading does not comply with pertinent Ordinances/Codes because it was not
graded to prevent accumulation of water.
as per Bureau of Meteorology data, the area received rainfalls in March 2021 which is
consistent with PS and JE’s view that surface water enters the subfloor t hrough weep holes
and gap in the paving causing high moisture in the proximity of the master bedroom where
water was unable to escape.
much of the claimed damage pre-existed the policy commencement on 1 February 2021.
The panel has carefully considered the lengthy submissions and material provided by the
complainant. The panel notes the complainant, and his wife are engineers. However, their
opinion is not an independent opinion. Further, the panel is satisfied the preponderance of the
expert opinion from a plumber, builder and engineer supports much of the insurer’s
contentions.
The panel notes the complainant’s contentions the damage was caused not only by the hot
water leak but because the hot water leak was not repaired quickly enough.
This contention has been considered by the insurer’s builder. Having reviewed the submissions
and the expert opinion and photographs, the panel considers the insurer’s builder has
persuasively rebutted this contention. Further, the complainant was responsible to repair the
leaking pipe.
The panel notes the complainant’s submission that the burst water pipe in April 2021 must
have been the cause of all the claimed damage because of the pre-purchase property report
obtained in June 2019.
The panel does not find this argument sufficiently persuasive in view of the nature of the pre-
purchase report, and the objective evidence from photographs that the damage was such that
it probably did not occur in February and March 2021 after the policy commenced. The panel is
satisfied the objective evidence shows long-standing damage which occurred (at least) in 2019
and 2020. Further, the pest report notes high moisture readings found in the bathroom and
kitchen which were not investigated. Also, the pre-purchase report put the complainant on
notice rainwater was entering through the subfloor.
The panel accepts some damage was caused by the burst water pipe and by rainwater run-off
in March 2021. However, based on the available information and for the reasons stated the
panel is satisfied the proximate cause (or the dominant or effective cause) of the disputed
damage was earth movement which had occurred over time and before February 2021
because of structural defects, faulty or poor workmanship or design in the subfloor and
ineffective drainage in the bathroom. Further, the available information establishes the disputed
damage was caused directly by or arising from events which occurred before 1 February 2021
when the policy commenced. For these reasons, the insurer is entitled to decline liability for the
disputed damage.
Fair the claim is cash settled
The complainant says the insurer has not acted fairly because it elected to repair the damage
and then subsequently offered to cash settle the claim.
It is clear from the terms of the policy that the insurer has the discretion to decide which
settlement method to adopt. If the insurer accepts a claim it can decide whether to repair or pay
the insured the cost to repair that part of the building that suffered damage.
Determination | Case number: 810508 Page 11 of 25
While acknowledging t he insurer’s discretion, the panel expects an insurer to act reasonably,
fairly and consistently with utmost good faith in exercising its discretion, having regard to the
circumstances of the claim.
The complainant wants the insurer’s builder to undertake the repairs. He says the insurer has
relationships with its builders, which allows it to get better pricing lower than the market prices.
The panel accepts the factors that are contributing to the moisture in the subfloor will need to
be addressed prior to the repairs being undertaken. The panel also accepts the insurer is not
liable for all the claimed damage. In these circumstances, the panel is satisfied it is fair the
claim is cash settled.
Cash settlement amount must be fair
In cash settling, the insurer must ensure the settlement amount is reasonable and sufficient for
the complainant to complete the necessary work himself. That is, the amount must be arrived
at having regard to all relevant factors. These include risk is passing to the complainant, since
he will lose the lifetime guarantee on the work and unknown variations and contingencies may
arise once repairs commence
The insurer based its offer on a scope of works from JE and a quotation from CS which
included repairs in the kitchen and living room and repairs to the skirting board in the dining
room. The insurer added 20% builders’ margin to its quotation and a 15% contingency for any
unforeseen damage. The insurer offered to pay $29,788.17 plus a 15% contingency allowance
($4,468.23) for repairs.
As previously set out in this determination, the panel accepts the subject leak caused damage
to the flooring in the dining and lounge room along with cracking in the walls in the family room,
kitchen, lounge and dining areas. CS’s quotation does no t include costs to repair this damage.
The complainant obtained two quotations from builders, EC and HG, amounting to
$129,616.30 and $191,521 respectively. These quotations include repairs for damage for
which the panel considers the insurer is not liable.
EC’s quotation has a price breakdown of the different rooms. The kitchen, living, dining and
lounge rooms cost of repairs equates to $62,057 including GST (rounded up). However, these
figures include repair items such as removal and replacement of joists and bearers in the
subfloor under the dining and lounge rooms which the panel accepts were not damaged by the
subject leak. Further, the quotations do not include costs to repair the wall cracks in the family
room, kitchen, dining and lounge room.
Analysis of quotations and a fair cash settlement
The panel notes JE’s initial scope of work included replacement of three rotten joists and four
rotten bearers in the subfloor near the kitchen. This was later excluded from its updated scope
of work as JE later considered these were not damaged by the pipe leak.
The panel disagrees and does not accept this outcome is fair in the circumstances. The panel
is satisfied, on balance, these three joists and four bearers probably would have been
damaged due to the leak from the ruptured pipe because of:
their close proximity to the leak.
possible direct contact with the water spray.
the amount of water which sprayed before the leak was repaired.
Determination | Case number: 810508 Page 12 of 25
The complainant argues the insurer should not rely on CS because CS is not independent. The
complainant also requires a supervisor’s fee and a 30% contingency allowance.
The panel is satisfied CS is sufficiently independent to provide a quotation for the cost of
repairs based on the scope of works prepared by JE.
The panel considers it is likely superv isor’s fees will be required once the final quotation is
prepared because of the likely increased costs in the final quotation. The panel also considers
it is fair to include these fees in the final amount payable by the insurer because there will be
several trades which will be difficult for the complainant to coordinate in view of his employment
duties and the unlikelihood he will be living in the house during repairs.
The panel is not satisfied it is fair that the 15% contingency is provided in view of the increase
in the cost of repairs and labour because of COVID-19. It considers a 30% contingency is
excessive. In all the circumstances the panel is satisfied a contingency of 20% is fair.
Relying on EC, the complainant says the architrave, skirting, kitchen joinery and cabinets, as
well as the kitchen island bench tops, cannot be reused once removed from the kitchen and
dining areas as these items have already been damaged by the insured event and it will be
difficult to remove the items and preserve them for future use. He says when they are removed,
the chances are that they will crack.
EC’s quote describes the demolisher’s work in the kitchen and living room which inc ludes
careful removal of the bench pantry unit, granite benchtops, cabinets and architraves. EC notes
the cabinet end panels and kick boards to the cabinets and the pantry door are to be removed
and disposed ( “ the items to be removed ” ).
EC’s quote notes th e re-use of kitchen cabinets and joinery and architrave in kitchen and
dining area is not possible. EC says the scope may change and may incur additional cost as it
may not be able to completely re-use all the kitchen items mentioned in the scope depending
on their current condition, but EC says it will re-use as much as it can.
JE’s scope of works describes these items to be removed, kept safe and reinstalled.
The insurer says if these items cannot be reused then the cost should come from the
contingency amount. The panel does not consider this outcome fair in circumstances where the
complainant’s claim is to be cash settled resulting in the complainant assuming the risk that
variations and contingencies may occur once repairs commence. The panel accepts EC has
foreshadowed a real and potential risk that “the items to be removed” may not be safely
replaced.
In all the circumstances, the panel is satisfied it is fair to accept the complain ant’s submissions
on this point.
The panel is satisfied it is fair the insurer should include a separate amount to not only
dismantle but to dispose and provide new items in a revised scope and quote for “the items to
be removed”.
The panel does not accept it is fair that if the old items cannot be re-used they should come
from the contingency fee.
Determination | Case number: 810508 Page 13 of 25
Cash settlement mechanism described
Should the complainant accept this determination then within seven days of notification of
acceptance the insurer is to resolve the claim in the manner described below.
Based on the available information and for the reasons stated, the panel is satisfied it is fair in
the circumstances the claim should be resolved in this way:
JE to prepare a new scope of works by consolidating the scope from his first scope of
works date d 28 October 21 “Individual Room Reconstruction: Damage caused by burst
pipe” to include the flooring in the dining and lounge rooms, the removal and replacement
of four bearers and three joists under the kitchen, repairs to the cracks in the family room,
kitchen, dining and lounge rooms and “the items to be removed” (JE’s new scope of works)
CS to update its quote once JE’s new scope of works is received (CS’s new quote)
CS to provide an estimate of the repair time under JE’s new scope of works so the
temporary accommodation benefit can be calculated
the insurer to provide a cash settlement to the complainant based on JE’s new scope of
works and CS’s new quote which will include supervisor’s fees, a 20% builder’s margin
and a further uplift of 20% for contingencies and variations which may occur once repairs
commence.
If the complainant wishes to obtain a quotation pursuant to JE’s new scope of works, then he
is entitled to do so within 14 days of receipt of JE’s new scope of works and CS’s new quote.
The parties are encouraged to work together to finalise the claim and the cost of repairs. If the
parties are unable to agree, the parties can return to AFCA for a decision about the cost of
repairs.
As the insurer will cash settle the claim, it is to pay interest pursuant to section 57 of the
Insurance Contracts Act (the Act) on the final cash settlement from 30 November 2021 (the
date of its final offer) until settlement.
Insurer required to pay temporary accommodation
Subject to limits, the policy provides cover for alternative temporary accommodation for up to
12 months if the insured property is damaged and the insured is unable to live in the property
as a result.
It is not in dispute the property will be unliveable during the repairs. CS estimated it would
take four weeks to repair the kitchen and living room areas. EC estimated it would take 12
weeks for the repairs, but its scope of work includes repairs for which the panel considers the
insurer is not liable.
The insurer has offered to pay for temporary accommodation: $6,412.00 (28 days x $229).
The parties’ position on this issue was governed by quotations which are now mostly
redundant.
The panel is satisfied the fairest way to resolve this issue is to require CS to estimate the time
it would take to undertake the repairs which will be required pursuant to JE’s new scope of
works as set out above.
Once determined, the panel is satisfied it is fair the insurer pay to the complainant for
temporary accommodation at $229 per day for the time CS says it will take to do the repairs
required pursuant to JE’s new scope of works as set out above.
Determination | Case number: 810508 Page 14 of 25
2.2 Is the insurer required to increase its non-financial offer?
Compensation payable in some circumstances
AFCA may award compensation (capped at $5,400) if there has been an unusual degree or
extent of physical inconvenience, time taken to resolve a complaint or interference with the
complainant’s expectation of enjoyment or pea ce of mind.
AFCA takes a conservative approach to awarding compensation. We do not award
compensation because the complainant has suffered some inconvenience. AFCA expects the
complainant to be moderately robust and to bear the normal degree of inconvenience
experienced when a problem occurs and to take reasonable steps to manage the situation.
Fair the insurer pays $4,000 compensation
The complainant complains about delay and the stress caused by the insurer’s claims
management. He seeks $5,400 compensation.
The insurer accepts the claim was prolonged due to insufficient investigations carried out
initially but says it took reasonable steps to remedy this and progress the claim. It argues the
time taken is not unreasonable given the complexity of the claim and the requirement for
further investigations to determine causation.
It said it provided regular updates to the complainant, apologises to the complainant for any
inconvenience caused and in recognition of the inconvenience offered $1,000 compensation.
The claim was made in April 2021. The insurer arranged the make safe and a building
assessment in a timely manner. The insurer’s final offer was not made until 30 November
2021. The panel acknowledges the complexity of the claim, but as set out in this
determination, the panel considers the insurer’s settlement offer and scope of work was
inadequate. The panel accepts this aspect of the complainant’s claims experience caused
inconvenience and stress to the complainant.
Given this, and considering AFCA’s conservative approach, the panel accepts it is fair the
insurer pays the complainant $4,000 non-financial loss compensation.
2.3 Why is the outcome fair?
The insurer is entitled to settle the claim based on its policy terms and expert opinion. As the
panel accepts the available information establishes much of the claimed damage was caused
before the policy commenced, it would not be fair for the insurer to pay all the claimed
damage. As the claim is to be cash settled, it is fair the insurer makes adequate provision for
contingencies and variations which may occur once repairs commence.
Determination | Case number: 810508 Page 15 of 25
3 Supporting information
3.1 Process
This matter was determined by a panel
Due to the nature of this dispute, it has been referred to a panel for determination. The panel
comprises the ombudsman, a member with significant experience in consumer and small
business advocacy and a member with extensive experience in the insurance industry.
The panel has decided this complaint based on what is fair in all the circumstances, having
regard to legal principles, applicable industry codes or guidance, good industry practice and
previous relevant determinations of AFCA or predecessor schemes (which are not binding).
AFCA’s approach to this complaint
A full exchange of the relevant information has taken place between the respective parties.
Each party has had the opportunity of addressing any issues raised. All the provided
information has been reviewed and considered. The parties have raised numerous issues in
their submissions to AFCA. However, commentary in this determination is restricted to those
issues considered relevant to the outcome.
It is an accepted principle of general insurance law that the insured bears the onus to
establish on the balance of probabilities that they have suffered a loss caused by an event to
which the policy responds. This is known as a prima facie or valid claim. Once so established,
the onus shifts to the insurer to prove on the balance of probabilities that an exclusion applies
if it seeks to deny or limit its liability for the loss.
Caselaw and proximate cause
Case law establishes:
The proximate cause of the loss is the dominant or effective or operative cause of the loss
whether or not that be the last in time or the sole cause.
If there are several causes operating contemporaneously, each must be examined for the
qualities of reality, predominance and efficiency as the active, efficient cause that sets a
relevant chain of events in action. If one cause would have caused the harm in any case,
and the other would not have done so in the absence of the first, the first is the proximate
cause.
A common-sense approach is taken to determine proximate cause.
How we assess complaints
AFCA is not a court of law. We do not have the power to take or test evidence on oath, or to
require third parties to give evidence. When we assess complaints, we consider available
documents, the recollections of the parties, and all relevant circumstances. We give more
weight to documents created at the time the events occurred. If there is no relevant
documentation, we will decide what is most likely to have occurred based on the information
provided to us. If there are conflicting recollections and these are evenly weighted, we may
find that a claim cannot be established.
Determination | Case number: 810508 Page 16 of 25
3.2 Relevant policy terms
The relevant policy extracts are referred to in the correspondence between the parties and in
the insurer’s Notice of Response. Both the polic y document and the Notice have been
exchanged with the complainant.
We will cover
Water or liquid damage
Loss or damage caused by water or liquid escaping from:
a fixed pipe or an object attached to a pipe, fixed gutter, fixed tank or a drain
a bath, basin, sauna, spa, shower base or shower wall, sink toilet or tiled floor that has
drainage holes
…..
We won’t cover
Loss or damage caused by water or liquid entering your buildings:
…. .
because of a structural defect faulty design or faulty workmanship
Additional buildings benefits
Alternative temporary accommodation (including for pets)
Costs of alternative accommodation for up to 12 months if your buildings suffered loss or
damage and you are unable to live in your buildings as a result.
Accidental loss or damage
We will cover
We will cover unintended and unexpected loss or damage to your buildings
We won’t cover
Damage caused by an event excluded under any section of this policy
Building and contents cover exclusions
We will not pay for any loss or damage which is caused directly or indirectly by:
settling shrinkage or any movement of earth
erosion, rust, corrosion, gradual deterioration, depreciation, wear and tear
a defect in an item, structural defects, faulty or poor workmanship or design
previous damage that has not been repaired
General exclusions
We will not pay for any loss or damage, or liability caused directly by or arising from:
any event that does not occur within your period of insurance
mildew, atmospheric or climatic conditions
Determination | Case number: 810508 Page 17 of 25
3.3 Extracts from material relied on by the parties
Record Key points
Prepurchase report
20 June 19
Visual prepurchase building inspection report and photographs 20
June 2019
No major defects found
Overall condition of the building average with the subfloor space
described as fair
Inspected part of the subfloor and one photo only provided
Weep holes to property unobstructed.
Summary of minor defects (which can potentially bec ome major
defects in future if not rectified) included subfloor rainwater a ccess
through side of subfloor
Subfloor ventilation fair, dampness normal, subfloor cleanliness
fair, timber formwork fair, low - lying foundation areas fair, drainage
- rainwat er access through side of subfloor
Bearers and joists fair, piers fair, wood de c ay damage not found.
Sewer drainage and plumbing pipes fair
General site not es - stormwater drainage and surface drainage:….
It is essential to prevent surface waters from entering the sub floor
area of timber floored dwellings to prevent rising damp fr om
causing peaking and cupping to the timber flooring materials. This
drainage gives best results once fitted on the high side elevations
of this as inspected dwelling or building (I refer to AS2870 for
compliant instructions if required.)
Shower leakage f ound: NO
Prepurchase pe st report
20 June 19
At the time of inspection, no visible leaks or mould were found
High moisture areas should be investigated
High moisture readings were found in the bathroom/kitchen areas
and swimming pool area
Claim no expertise in plumbing and drainage, however it appears
that drainage is generally AVERAGE
RAINWATER ACCESS THROUGH SIDE OF SUBFLOOR
Weep holes in external walls were clear allowing air free flow
Determination | Case number: 810508 Page 18 of 25
Record Key points
Insurer’s expert (CS)
08 - 06 - 2021
Complainant concerned about the floor outside the bat hroom
Perimeter of room was mould affected consistent with a leak from
the shower
Plumber performed full leak detection to main bathroom
Damage to hallway floor outside bathroom aris es from escape of
liquid from the failed membrane and shower screen
Floor tiles fall away from floor waste and no drainage connected to
drainage
Mould on dirt to subfloor and underside timber floor through 80%
of the house consistent with multiple water issues that have
occurred over time
Elevated levels of moisture to subfloor appear more consistent to
storms causing damage to the flooring through internals
Mould in the bedroom next to the bathroom due to escape of liquid
from bathroom
Rippling to the flooring consistent from the bearer and joist
compromised from wood rot that has been an ongoing event
Damage to the kitchen floor consistent to a burst pipe that has
been repaired but kitchen particle floor cannot be repaired until the
moisture has been treat ed – maintenance required to pre vent
stormwat er from entering the subfloor and escape of liquid from
the bathroom
Determination | Case number: 810508 Page 19 of 25
Record Key points
Insurer’s expert (PS)
Engineering Report
30 - 06 - 2021
Senior structural and civil engineer inspected, and photographed
property 18 June 21 and reviewed documents provided by insurer
including earlier plumbing reports
Report describes his findings
Complainant said started losing hot water in mid - April and ki tchen
floor lifted
Damage to the kitchen floor was caused by the hot water leak age.
Rest of the damage to the floor and bathroom was most likely due
to underlying soil movement caused by seasonal changes.
Inspection showed a pattern of ground movement whi ch has been
exposed to natural elements, mainly surface water entering the
subfloor area at will and for a long time.
Movement and subs equent subsidence has not been caused by a
single event, but rather a gradual issue over a long term.
Subfloor, floor and bathroom damages in other parts of the
residence refer to the age, lack of property foundation, poor
maintenance, and long - t erm soil movement
Surface water ponding under the floor of the lifetime of the house
has caused the damage to the other parts of the floor
Primary cause of the damage sustained to the other parts of the
premise floorboards is the ground movement combined with lack
of appro priate foundation and age.
Water damages to the bathroom floor and wall tiles appeared pre -
existing and can possibly be due to poor maintenance or late
awareness.
Water seeping gradually through bathroom walls damaging the
floor and wall and unrelated to recent water leak
Water damaged timber framing under kitchen to be replaced as
beyond repair but prior to that work damaged brick piers and
timber supports are to be realigned on appropriat ely designed pad
footings.
Photographs support findings including uns ealed gap along the
paving and turf too high and close to vents
Insurer’s expert (JE)
Caus ation Report
30 - 06 - 2021
This builder inspected and photographed property 18 June 21
Describes damage he saw in the hous e and subfloor and
summarises other rep orts provided
Water escapes from the shower screen. Water runs to the floor
waste and drops into the subfloor causing framing to rot. Water
flows out to the hallway bec ause the tiling is not graded to the floor
waste. Bathroom not constructed in accordanc e with code.
External tiling installed at a level higher than the ground level
under the subfloor and surface water enters the subfloor through
the brick vents which are higher than ground level
Water flowing into the gap between the external wall and concrete
path and is absorbed into the brickwork below the damp proof
course and once the brick is saturated the moisture escapes into
the subfloor contributing to subfloor dampness – code breach
Determination | Case number: 810508 Page 20 of 25
Record Key points
Gr ound level to the subfloor is lower than the ground level outside
and once surface water enters under the hous e it cannot escape –
code breach
Damage to the flooring in the kitchen and family room was due to
burst pipe and pre - existing extremely high leve ls of moisture to the
subfloor area.
Damage to the kitchen cupboards and joinery was due to the burst
water pipe.
Detachment of the skirting boards in the living room on the wall
which backs onto the kitchen is due to the burst water pipe
Damage to the eng ineered floors in the dining, lounge and hallway
is due to pre - existing extremely high levels of moisture to the
subfloor area.
Any damage sustained to the master bedroom or the small
bedroom adjacent to the bat hroom is due to pre - existing extremely
high l evels of moisture to the subfloor area.
Before remedial work can start the membrane to the bathroom
needs to be reinstated and the subfloor needs to be drained and
the house protected from the effects of surface water to comply
with building codes
Insurer’s expert (JE)
Report and Scope of Works
28 - 10 - 2021
Reins pected 18 October 21 and photographed cracks pointed out
by complainant and reviewed complainant documents and
submissions
Included cracking in a scope of works but cannot comment
whet her cracking related to burst pipe
Mould to bathroom and ensuite not due to burst pipe but due to
pre - e xisting moisture under the floor and will continue until
bathroom drainage repaired and sub floor correctly graded
Floor framing under remaining areas is rotten due to long - term
moisture under the floor and not due to several months of water
ponding under the house from burst pipe
Rooms will continue to experience mould until bathroom drainage
is repaired and subfloor area graded
Texture coating to bricks failing bec ause of presence of moisture
which is not due to the burst pipe
Moisture caused by rainwater run - off and inadequate subfloor
drainage
Water from burst pipe cannot reach brickwork at front of house
because pressure from burst pipe not great enough and water
ponding at the base of the burst pipe cannot travel uphill
Damage caused by the pipe was confined to the kitchen and
family room and the detached skirting in the dining room.
Sk irting in the dining room is close enough to the burst pipe to be
caused by the leak.
Other damage throughout the house is due to inadequate and
illegal sewer and stormwat er damage.
Previous repairs to living room floor indicate historic movement
Determination | Case number: 810508 Page 21 of 25
Record Key points
Ventilat ion openings provide an easy access for surface water to
enter subfloor
Ground level under the floor is significantly lower than the
surrounding ground level and surface water can’t escape and
saturates the soil
Problem is once wat er is under the house i t cannot drain away
Refers to 3 omissions in the prepurchase inspection which were
all present at the time of ins pection including no sewer drainage to
bathroom floor waste, rotten floor framing timber, and inadequate
grading of the subfloor foundations. Because of omissions says
report is of insufficient depth and scope to be relied on
Prepurchase report does not include any photos of the bearers,
joists or brick pier so no evidence of deterioration in subfloor in
June 2019.
Does not dispute the amount of moisture which may have leaked
from the burst pipe but does not believe leak responsible for
damage to dining and lounge room because the velocity of the
water was not great enough to reac h the centre of the lounge
room, the centre of the lounge room is wet on top meaning water
must’ve come from some other cause: subfloor drainage and
location of weep holes will caus e the soil to become wet: and
there are examples of pre - existing damage in lounge room
Building should have complied with 1973 Ordinance wh ich
included the subsoil should be effectively drained; the ground
surface under the building should be re - graded and provided with
adequate outlets to prevent accumulation of water under the
building; the ground beneath the building should be covered with
an approved damp resisting material
Extension including the kitchen and family room probably occurred
when building code in force which included that the ground must
be graded so the area under the building is above the adjacent
external finished ground level and surface water prevented from
ponding
Previous repairs to the living room flooring indicate that there has
been historic movement to the floor framing and flooring in the
room.
Ventilation openings provide an easy access for surface water to
ente r the subfloor.
Ground level under the floor is significantly lower than the ground
level.
Surface ground water is unable to escape which has saturated the
soil
Surface rainwater has been entering the subfloor for some time
and has saturated from the top a nd caused historic damage.
Accordingly, the damage to the flooring in the dining and lounge
room is not attributable to the ruptured water pipe.
The reason I concluded the damage due to the burst pipe was
Determination | Case number: 810508 Page 22 of 25
Record Key points
confined to the kitchen and family room was because I found the
soil under the centre of the lounge room to be wet. The burst pipe
did not spray water onto the top of the soil as far as this point
There’s a brick wall under the kitchen floor running north and
south located between the sink cupboard and th e island bench
(brick wall 1). Rupt ured pipe fixed to brick wall 1
Wall below floor level which separates the kitchen from the dining
room is a single skin brick wall with attached piers (brick wall 2).
Kitchen on east of wall and dining on west of wall
Photo of brick wall 2 taken from the dining room while water
exiting the pipe whic h shows water is spraying about 900mm from
brick wall which is 3m short of the observed wet area under the
dining room
Water at the extent of its spray would have dropped d own int o the
soil immediately below and percolated into foundations
Bulk of 435kl of water would have fallen between the two brick
walls. To travel as far as the lounge room would require the water
to travel uphill as there is a low point at the base of t he brick wall 2
Water can rise through soil due to capillary action but only if all the
soil below it is full saturated. Water will continue to flow
downwards due to gravity. For the soil to be so saturated that
additional water travels up rather than dow n effectively mean the
water table has been raised locally. Clearly this would not occur by
the addition of 435kl of water.
This led me to conclude that the subsoil under the dining area has
been wetted by continuous surface water flow over a prolonged
per iod rather than by escaped water from the burst pipe.
Velocity of water from the burst pipe was not great enough to
reach the centre of the lounge room.
Subfloor drainage and location of weep holes will caus e the soil to
become wet.
Examples of pre - existin g damage in the lounge room including the
pre - finished veneer timber flooring system which has been
repaired, and the tilted pier and the warped hardwood framing in
the family room which are further evidence that moisture has been
present in the soil for y ears.
Storm in March 2021 allowed water to ent er the subfloor and
saturate the soil which also occurs during any heavy rain
Ground under the subfloor has not been graded to drain water
away which explains the saturation of the subfloor
Not possible that one storm event can cause the foundations to
become so saturated that footings settle, and hardwood timber
deflect
March 21 storm would have increased the moisture content of the
soil. But this has only exacerbated a pre - existing condition and
would not h ave caused deflection of any framing timbers or
settlement of the piers.
Determination | Case number: 810508 Page 23 of 25
Record Key points
Only the first 350 litres of water from the storage hot water heater
would have been hot. After the pipe ruptured, the escaping water
would have been lukewarm at best as the tank woul d have been
constantly refilling with cold wat er and the element would not have
time to reheat the water. Other areas of the house have suffered
damage due to moisture from inadequate sewer and stormwater
drainage.
If inadequate drainage is rectified prope rty will dry out and further
deterioration will be minimal
Provided scope of works.
Insurer’s expert (PS)
Engineering report in second
Reply
17 - 08 - 2021
Photographs of cracking in the house (dated18 October 21)
reviewed as well as visual inspection through a video call
Cracks observed during rec ent site visit described
Reiterates his opinion and rebuts complainant’s arguments
Impossible for water to trav el as far as the dining room window
and ensuite and hallway
Cracking does not appear to be related to the burst pipe but rather
an ongoing problem caused by seasonal ground movement. There
was numerous evidence of repairs to many cracks in support of
this contention.
Floor framing appeared rotten, an indication of exposure to a
lifetime of underground moisture. The leakage lasted a month or
two which is not considered long enough time to cause this type of
damage. The moisture trapped in the subfloor comb ined with
water entering this area have caused the ground movement and
gradual deterioration of the subfloor framing.
Cracking will continue unless steps are taken to prevent water
entering and ponding in the subfloor
Cracks and gaps opening in various pl aces are a clear indication
of general ground movement that are seen in various plac es and
cannot be related to a single event.
Foundation saturated for many years – volume larger than the
failed hot water leakage
Undulation in the bearers and joists of t he subfloor framing is more
solid evidenc e of a long - term issue. These were observed under
the family room; the curvat ure cannot be caused by a short - term
moisture exposure. Ground movement is a force large enough to
deform the timber and only over a very long time.
No evidence supporting the claim. All the evidence gat hered so far
attributing to the seasonal ground movement as previously stated.
New evidence can only support this fact because of the repairs
found during the inspection. It is evident that m ost of the cracking
are pre - existing that has reappeared and hence cannot be related
to the hot wat er system failure.
Prepurchase report two years old. Cracks likely to have been
repaired and not visible during inspection; tilting pier and floor
Determination | Case number: 810508 Page 24 of 25
Record Key points
framing mo vement possible since the report; dispersed water not
capable of changing the moisture content in the soil beneath the
kitchen floor in such a short period of time and not related to
ground movement; fact no mould apparent in 2019 doesn’t mean
the floor wa s in healthy condition - referred to as fair
Visual prepurchase inspection limited
As for rainfall, water can still enter the subfloor, pond and saturat e
the soil over years – volume of water by this proc ess is large and
over time and not comparable to b urst hot water pipe
Volume of water escaping from burst pipe is not considered large
and over a short period compared to long - t erm water entering
subfloor
Water pressure not high enough to spray the water ac ross the
whole house and limited to the kitchen area; and bathroom too far
from the event and spray of water would not reach the floor
framing underneath
Information from complainant may support site founded on
expansive soils and supports ground movement theory
Soil movement normally occurs due to moi sture changes which
caused swelling or shrinkage and not relat ed to described
hydrostatic pressure
No doubt about the volume of water escaping from the burst pipe
and soaks the ground underneat h but the volume disperses over
short period of time and not ov er years. The leak is not
responsible for ground movement
Even if only two weep holes are below the surface it is still enough
for water to enter and over years is noticeable volume
3.4 Other relevant material considered and relied on
Parties’ submissions/emails and all attachments to all submissions/emails.
Expert reports.
Complainant submissions including numerous attachments and complainant’s comm entary
on material from insurer.
Photographs.
Correspondence between the parties.
Determination | Case number: 810508 Page 25 of 25
Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.