Accidental damage claim declined for mould and moisture damage to insured pool and change rooms
Text of the determination
Determination
Case number 794017
Financial firm Guild Insurance Limited
Determination | Case number: 794017 Page 1 of 15
Case number: 794017 2 March 2022
1 Determination overview
1.1 Complaint
The complainant is a company and represented by its broker in this complaint. For simplicity,
I will refer to the complainant company and broker collectively as “the complainant.”
The complainant lodged a claim under an industrial risk policy held with the financial firm
(insurer) for accidental damage to an insured property. The complainant says a staff member
accidentally left off a pool cover after a hydrotherapy session prior to a school holiday
shutdown period in 2016. The complainant says the absence of the cover over several days
led to condensation forming throughout the internal surfaces of the pool and change rooms
which resulted in mould and moisture damage.
The insurer declined the claim saying the cause of the damage is subject to policy exclusions .
The complainant disagrees with the insurer’s decision and seeks the insurer cover the cost of
repairs carried out in 2017/2018.
1.2 Issues and key findings
Is the insurer entitled to decline the claim?
No. While pre-existing ventilation issues contributed to mould damage, the claim event was
also causative of loss. The available information establishes on the balance of probabilities
damage occurred due to a combination of poor ventilation and the accidental failure to
reinstate the pool cover, leaving the pool uncovered for consecutive days. For this reason, the
insurer is required to contribute toward the resultant claim repairs.
Why is the outcome fair?
The available material indicates the claimed damage was caused by poor ventilation
particularly in the changerooms, poor ventilation was not necessarily causative of the damage
and condensation caused by the event was significant. As some of the causes of damage are
covered by the policy and some excluded by the policy it is fair the insurer contributes 50% to
the resultant damage.
1.3 Determination
This determination is partly in favour of the complainant.
Should the complainant accept this determination then within seven days of notification of
acceptance the insurer is to pay to the complainant $26,290.
Determination | Case number: 794017 Page 2 of 15
2 Reasons for determination
2.1 Is the insurer entitled to decline the claim?
Parties’ submissions and material considered
The complainant says the pool cover being left off the heated pool (which is maintained at 33
degrees) for several days caused the claimed damage as high levels of moisture were
released within the pool and change rooms (the event).
It claims support from an expert (RT). RT says there was significant evaporation from the
uncovered heated pool and ventilated windows would not have made any considerable
difference as insufficient evaporated pool water would have been removed.
The complainant submits RT is supported by the contractor who describes the room on 4
October 2016 as full of condensation with water dripping from the ceiling like rain.
The complainant also contends the insurer should pay to rectify the damage as:
the damage was due to this one-off event as no damage or mould was reported prior to
October 2016 either by staff or by the insurer’s surveyor
the insurer would not insure a building that failed to meet building standards
the sealed laminate windows did not remove all forms of ventilation within the pool room as
louvred windows are installed over the main entry doors to the pool room and there are
extraction fans within the skylight in the roof
there has been no further mould since the repairs were completed in January 2018
as no mould has developed since the event the mould must have been caused by the pool
cover being left off.
The complainant notes the insurer agrees the event contributed to t he claimed damage and
submits it should therefore contribute to some of the claimed costs.
The insurer says the event is not the cause of damage. After a site inspection and relying on
expert opinion the insurer says the mould breakout was not the result of a one-off event but
long-term exposure to moisture caused by condensation from hot showers.
The insurer also says the moisture and ventilation problems which caused the mould damage
were the result of inadequate ventilation which was ongoing and had pre-existed the event.
The insurer acknowledges the event would have increased the humidity for a short time.
Relying on a report from its builder (MC), the insurer confirms there was mould in the
bathrooms, pool room and storage cupboard. The insurer says MC also noted significant
condensation and rust marks to the steel surfaces in the pool room, bursting cupboards and
swollen vertical trim around the skylight in the bathrooms.
The insurer submits had the ventilation been adequate then leaving the pool cover off would
not have caused the damage. The insurer argues:
the 2015 works to the pool area involved the replacement of louvred windows to fixed
closed windows which eliminated all cross ventilation locking in condensation and moisture
the change rooms had poor ventilation because ventilation was reliant on patrons
switching on the fans (which they preferred not to do to maintain warmth)
the pool room had the least amount of mould which (considering the event) should have
been the most affected area
Determination | Case number: 794017 Page 3 of 15
most of the mould was located within the shower recess indicating it was more likely to be
due to the nature of use with mould directly above the showers
previous issues relating to expanded materials within the shower area show ongoing
issues
there are now fixed metal louvred windows to the north wall, new fans to the pool area and
auto fans to the change/shower rooms and as these items have now eliminated ventilation
issues this shows poor ventilation is probably the cause of the claimed damage
rust indicates moist atmospheric conditions and takes time to occur
its survey report was for underwriting purposes and does not consider building compliance.
Complainant must establish all claimed damage caused by the event
The complainant must establish on the balance of probabilities it has suffered a loss caused
by an event to which the policy responds. This is known as a prima facie or valid claim.
Once so established, the onus shifts to the insurer to prove on the balance of probabilities
that an exclusion applies if it seeks to deny or limit its liability for the loss.
The policy provides cover for accidental damage caused by any peril or circumstance not
more specifically covered or excluded by the policy. Relying on policy exclusions, the insurer
says it is entitled to decline the claim.
Both parties rely on expert reports. A summary of the reports is set out in supporting section
3.3 of this determination.
Extracts from the policy terms relied on are set out in supporting section 3.2 of this
determination.
Analysis of material and submissions
Having reviewed the available information, I accept:
the complainant is a disability service operator providing support and training opportunities
for the disabled
in June 1999 the building (which included an indoor pool) was open for use
in early 2015 the complainant’s board approved renovations to be completed in stages
in March 2016 renovations were completed to the property including to the pool area, pool
toilet, shower and change rooms
the renovations included “removal of existing louver glass panels and windows and replace
with 6mm fixed glass panels”
on 27 June 2016 the insurer reported no issues to be addressed following its survey
between 29 September and 4 October 2016, the pool cover was left off the heated pool
on 4 October 2016 a contractor attended to install a pool lift and discovered the damage
and said “the room was full of condensati on and water was dripping from the ceiling like
rain”
on 7 October 2016 the insurer’s assessor attended
on 11 October 2016 the assessor recommended the pool room be isolated due to active
mould growth and that a hygienist and builder inspect the damage
o n 12 October 2016 the insurer’s builder attended
on 26 September 2017 repairs to the pool room commenced
in January 2018 certain repairs were completed costing $66,495.00.
Determination | Case number: 794017 Page 4 of 15
Assessor’s opinion not sufficiently persuasive
The insurer’s assessor confirmed mi ldew and mould. He also noted no ventilation was
present in the pool area. On the insurer’s instructions he engaged a builder (MC) to provide a
report on the cause of damage and the operation of the relevant building codes.
While the assessor says it appears the loss can be attributed to condensation/evaporation
due to staff neglecting to place the pool blanket over the pool, I consider the overall tenor of
his reports is not persuasive. The assessor seems unsure of the policy response and cause
and relies on the opinion of MC.
Insurer’s builder says there was inadequate pre -existing ventilation
MC inspected and photographed the damage on 12 October 2016. He describes and
photographs the location and extent of damage.
He photographed windows which are fixed and photographed some louvre vents above the
internal entrance doors.
I accept annotated photographs support his observations namely the mould damage is most
apparent in the bathrooms above the showers; parts of the steel in the pool room are rusted;
and boards in the cupboard in the pool room and vertical trims surrounding the roof lights in
the toilet areas are damaged.
I accept MC’s observation that mould was not apparent in areas where it would be expected
where hot moist air from the pool would have most concentrated (for example at the highest
point of the pool room).
Having reviewed the photographs, I accept there is more mould in the shower rooms than in
the pool room. I agree with MC’s observation that had m ould been due to moisture in the pool
room there would have been more mould in the pool room than in the shower room.
Similarly, a photograph of the ceiling above the toilet (almost immediately next to the shower)
shows no mould yet it would have been exposed to moisture to the same extent as the ceiling
above the shower by the event.
MC sets out building standards relating to ventilation applicable at the time. I note a space
within a building must be provided with adequate ventilation consistent with its use and must
be provided with outdoor air to maintain adequate quality.
The available information shows that at the time of the event outdoor air was not provided to
the pool room.
MC noted the only ventilation in the pool room was above the entrance door which was only
to the interior of the building. MC says the removal of the glass louvres in the pool room had
significantly reduced ventilation because no fresh air came from outside the building as
required by regulation. In those circumstances I agree the pool room was not adequately
ventilated.
I have considered MC’s photographs. I agree rust can be seen in several places on the steel
inside the pool room. I also agree rust takes considerable time to occur and the rust through
the paint would not likely have occurred in the short time between the claim event and MC’s
inspection.
While the bathrooms were fitted with mechanical extract fans MC says the fans only operated
when the lights were switched and steam from hot showers caused the mould seen on the
Determination | Case number: 794017 Page 5 of 15
roof. I accept the pattern of damage in the bathrooms points to deficiencies in the ventilation
system. This is because mould was mostly present around sealed windows and near
showers.
Insurer’s survey report not determinative of the outcome
I note the risk report prepared on 21 June 2016. I accept it is prepared for a specific purpose.
I do not agree with RT when he says the extent of the mould in the bathrooms on the ceilings
the mould would have been flagged in the report as a health risk. I have considered the
photographs which accompany the report. Neither the photographs nor the report refers to
mould in the bathrooms.
In view of the restricted reasons for preparing the report I do not consider the report is
conclusive one way or the other as to the state of mould in the bathrooms at the time of the
report.
Complainant’s expert says ventilation would not have made considerable
difference
I am satisfied there was inadequate ventilation, but the insurer must establish the inadequate
ventilation was the proximate cause of the loss.
The complainant’s expert (RT) says even if there had been natural cross flow ventilation it
would not have made a considerable difference. I accept he has the expertise to comment.
He describes high humidity and the large amount of heated water which would have been
released. The large amount of condensation caused by the event is described by the
contractor who discovered the damage.
Insurer not taken sufficient account of extent of condensation
MC says steam and moisture related damage were ongoing problems, but he concedes the
rooms would have been substantially more humid than normal.
This is supported by the observation of the contractor who first discovered the damage.
The insurer acknowledges the event would have increased the humidity for a short time.
I am not satisfied the insurer took sufficient account of the extent of condensation and the
resultant damage caused by it.
Some claimed damage caused by the event and some by inadequate ventilation
I accept the event caused accidental damage to the property. But the complainant must also
establish on the balance of probabilities the event so extensively damaged the property that
the insurer must cover it for the entire claim. Based on the available expert evidence, I am not
satisfied the event has caused all the claimed damage.
Having considered all the available information, I consider some of the claimed damage was
caused by the event and some was caused by inadequate ventilation (particularly in the
bathrooms) which pre-existed the event.
Ventilation improved by the complainant after the event
As for the contention by the complainant there has been no further mould damage since the
claim event I accept from the available information and MC’s opinion that new fans have been
installed in the bathroom which automatically turn on when one enters the bathroom. I accept
Determination | Case number: 794017 Page 6 of 15
this resolved the mould issue in the bathroom as the fans were not reliant on individuals
switching them on.
I also accept the permanent “open to the air” fixed louvred windows installed after the event
remediated the ventilation issues.
Based on the available information I do not accept the complainant’s contention that as no
mould has developed since the claim event the mould must have been caused by the pool
cover being left off. Rather, I am satisfied the available information establishes this is
probably because the complainant has improved the ventilation by the work done i n 2017/18
as evidenced by option 6 in the repair information provided by the complainant.
Fair the insurer pays the complainant $26,290
There is no scientific or conclusive way to determine the contribution of the event to the
resultant damage. I have estimated its contribution based on my review of the available
material and what I consider is fair in the circumstances.
The complainant has provided material about the cost of repairs. Extracts are set out in
supporting section 3.3 of this determination. I do not consider it is fair for the insurer to pay for
option 6 which relates to installing new ventilation. This is not resultant damage.
Based on my review, I am satisfied it is fair the insurer pays 50% of option 2 ($38,500) and
option 3 ($9,300) plus GST. I calculate 50% of these items and GST to be $26,290.
I do not propose to include statutory interest in the amount to be paid by the insurer. This is
because some of option 2 include installing a new roof ventilator for which the insurer is not
responsible and some of repairs in the pool room would have included rust repair which
probably occurred over time and were not due to the event. To avoid doubt, the amount to be
paid by the insurer is net of any policy excess payable.
2.2 Why is the outcome fair?
The available material indicates the claimed damage was caused by poor ventilation
particularly in the change rooms, poor ventilation was not necessarily causative of the
damage and condensation caused by the event was significant. As some of the causes of
damage are covered by the policy and some excluded by the policy it is fair the insurer
contributes 50% to the resultant damage.
Determination | Case number: 794017 Page 7 of 15
3 Supporting information
3.1 The AFCA process
AFCA’s approach is based on fairness
AFCA has determined this complaint based on what is fair in all the circumstances, having
regard to:
the legal principles
applicable industry codes or guidance
good industry practice
previous decisions of AFCA or its predecessor schemes (which are not binding).
The respective parties have completed a full exchange of the relevant information, and each
party has had the opportunity to address any issues raised. We have reviewed and
considered all the information the parties have provided.
While the parties have raised several issues in their submissions, we have restricted this
determination to the issues that are relevant to the outcome.
It is an accepted principle of general insurance law that the insured bears the onus to
establish on the balance of probabilities that they have suffered a loss caused by an event to
which the policy responds. This is known as a prima facie or valid claim. Once so established,
the onus shifts to the insurer to prove on the balance of probabilities that an exclusion applies
if it seeks to deny or limit its liability for the loss.
As advised to the parties, we have considered it appropriate to expedite this complaint in
accordance with the Operational Guidelines to the AFCA Rules, due to the nature of the
complaint. Accordingly, this complaint has not been the subject of a recommendation and has
proceeded directly to determination.
Caselaw and proximate cause
Case law establishes:
The proximate cause of the loss is the dominant or effective or operative cause of the
loss whether or not that be the last in time or the sole cause.
If there are several causes operating contemporaneously, each must be examined for
the qualities of reality, predominance and efficiency as the active, efficient cause that
sets a relevant chain of events in action. If one cause would have caused the harm in
any case, and the other would not have done so in the absence of the first, the first is
the proximate cause.
A common-sense approach is taken to determine proximate cause.
We assess complaints on available information and circumstances
AFCA is not a court of law. We do not have the power to take or test evidence on oath, or to
require third parties to give evidence.
When we assess complaints, we consider:
available documents
the recollections of the parties
all relevant circumstances.
Determination | Case number: 794017 Page 8 of 15
We give more weight to documents created at the time the events occurred. If there are no
relevant documents, we will decide what most likely occurred based on the available
information.
If there are conflicting recollections and these are evenly weighted, we may find that a claim
cannot be established.
3.2 Extracts from the policy
The relevant policy extracts are referred to in the correspondence between the parties and in
the insurer’s Notice of Response. Both the policy document and the Notice have been
exchanged with the complainant.
Product di sclosure
statement (PDS)
Key points
Page 8 General Definitions
Accidental Damage
for the purposes of any Limit or Sub - Limit of Liability or Deductible
as shown in the Schedule means damage caused by any peril or
circumstance not more specific ally covered or excluded by this
Policy other than fire, lightning, thunderbolt, explosion, imp losion ,
earthquake, subterranean fire, volcanic eruption, impact, aircraft
and/or other aerial devic es and/or articles dropped therefrom, sonic
boom, theft, breakage of glass, loss of money, the acts of persons
taking part in riots or civil commotions or o f strikers or locked out
work ers, or of persons taking part in labour disturbanc es or of
malicious persons or the acts of any lawfully constituted authority in
connection with any of the foregoing acts, or in connection with any
conflagration or other cata strophe, storm and/or tempest and/or
rainwater and/or wind and/ or hail, water or other liquids or
substances discharged, overflowing or leaking from apparatus,
appliances or any other system at the premises or elsewhere.
Page 21 Perils Exclusions
The Insurer(s) shall not be liable under Sections 1 and/or 2 in
respect of:
…
3. physical loss, destruction or damage occasioned by or happening
through:
a) moths, termites or ot her insects, vermin, rust or oxidation, mildew,
mould, contamination or pollution, wet or dry rot, corrosion, change
of colour, dampness of atmosphere or other variations in
temperature, evaporation, disease, inherent vice or latent defect,
loss of weight, change in flavour texture or finish, smut or smoke
from industrial operations (ot her than sudden and unforeseen
damage resulting therefrom)
b) wear and tear, fading, scratching or marring, gradual deterioration
or developing flaws, normal upkeep or making good
c) error or omission in design, plan or specification or failure of
design
Determination | Case number: 794017 Page 9 of 15
Product di sclosure
statement (PDS)
Key points
…
e) faulty materials or faulty workmanship.
Provided that this Exclusion 3 a) to e) shall not apply to subsequent
loss, destruction of or damage to the Property Insured occasioned
by a peril (not otherwise excluded) resulting from any event or peril
referr ed to in this exclusion.
3.3 Extracts from material relied on by the parties
Date Action
Extracts from Stage 1 works
Issued 4 September 2015
General pool area room 2:15. Removal of existing
louvre glass panels and windows and repl ace with
6mm fixed glass panels.
Pool area bathroom renovation: demolish remove and
replace all existing partitions, toilet suites, basins,
showers, internal dividing wall .
Extracts from work i ssued 26
September 2017
Quote: pool area and remediate mould in change
rooms .
Option 2 Change rooms
3 change rooms affected by mould .
Remove and plaster, replac e swollen timbers, paint,
and install new roof ventilator .
Option 3 pool room
Remove existing mould in pool area and replace
swollen joinery in storage cupboard .
Option 6 ventilation
Install new roof ventilator and new whirly birds roof
vent to ceilings .
Invoice
17 October 2017
Pool repairs as per attached quotation for items
Option 2 $38, 500
Options 3 $9,300
Option 6 $12, 650
Total $60,450
Plus, GST $6,045
Total $66,495
Insurer’s ri sk report
21 June 2016
Insurer conducts site visits to make an underwriting
evaluation and produces survey reports and risk
improvement recommendations structured around
conditions seen and information provided at the site
vis its .
Disclaimer: Reports have been prepared for the client
on a specific and agreed basis and should not be
Determination | Case number: 794017 Page 10 of 15
relied upon by any other party. The Reports have been
prepared solely for the purposes of (i) identifying the
minimum requirements that must be met for (the
insurer) to provide appropriate insurance coverage;
and (ii) determining premiums payable to (the ins urer)
in respect of such coverage. The Reports are not
intended to be a substitute for appropriate
professional, legal or other advice, and do not advise
or report on, or certify, compliance with any code,
standard or Act (including, without limitation, the
Building Act 1975, and the Building Code of Australia),
regardless of whether or not any recommendations are
made. ( T he insurer’s) surveying ser vic es are only
provided subject to the above disclaimers.
Site was a school until acquired for use as various
community - based support programs .
Renovation program currently undertaken with recent
capital works completed as well as ongoing works for
further improvements.
Constructed in early 60s mainly of brick with composite
cladding attached (perhaps in 70’s) to most external
walls, concrete floors, and met al roofing.
Building in excellent condition .
Surveyors’ overall opinion: well - prese nted risk with
good management controls and good housekeeping.
Ongoing capital works will further improve this facility.
Adverse features include: Some asbestos exposure –
minor and well controlled .
Not - for - profit organisation in a highly regulated
indus try.
Risk assessment: standard for class and acceptable .
No risk recommendations included in report .
Asse ssment report (CR)
13 October 2016
Accidental damage discovered 3 October 2016 .
Assessor photographed and inspected 7 October 2016
– damage manifested in mould and mildew throughout
the entire indoor pool building .
Since occupying the building it was renovat ed mainly
installation of ramps, internal lifts and retrofitting the
property to suit the disabled.
Facility on two weeks shut down for s chool holidays
and insured decided to upgrade changing facilities
within the pool room .
C ont ractor attended 3 October 2016 and found entry to
the pool area , all walls and ceilings covered in
condensation and mould and mildew .
Pool last used for hydrotherapy on 29 September 2016
when staff neglected to reinstate pool blanket .
Indoor pool is heated – at time of ins pection
maintained at 32 to 33°.
Determination | Case number: 794017 Page 11 of 15
In the absenc e of pool blanket evaporation occurred
which led to condensation building up leading to
m ildew and mould now on all surfaces .
Blanket is to prevent evaporation and condensation .
No ventilation present .
Asked builder to report specifically about building
breaches at time of renovations as glass louvre
windows were removed and sealed laminate glass
installed which removed ventilation .
Noted mildew and mould appearing on all surfaces in
the pool room and changing facilities .
Engaged S to attend and conduct mould sampling to
ascertain full extent of damage and reinstatement
works required .
When insured aware of event all external doors
leading to the pool room were opened to allow cross
ventilation and extraction fans in change rooms
engaged .
Hygieni st (S) mould report
11 October 2016
Mould present on plaster wall, ceiling linings, window
frames, beams throughout pool area and change
rooms .
Estimated remediation costs, scaffolding installation
and hygienist consultation including GST $43,450 .
Building consultant report
(MC)
17 October 2016
Inspected and photographed insured property 12
October 2016 .
Asked to comment on best practice for ventilation
when building renovated and a pplicable regulations
provided.
M ould infestation has occurred, but it is most
prominent on the bathroom ceilings above the showers
due to the heightened moistu re, exacerbated by lack of
cross ventilation at these points.
I mmediately adjoining toilet rec esses were relatively
free from mould.
Both areas would have been subjected to the exact
same extent of moist air following the reported event,
yet the mould le vels were substantially different,
leading to conclusion the event itself was not the
primary cause of the mould.
The minor amount of mould in the pool room generally,
and particularly at ceiling level, further confirm that the
reported event was not the primary cause of mould
infestation. Had it been, there would have been a lot
more mould on the pool room ceiling surfaces.
Inappropriat e material (composite/chip board) has
been used for the vertical trims surrounding the roof
lights and for the pool equi pment storage cupboard.
Components have burst. The extent of damage far
exceeds what would have occurred during or as a
Determination | Case number: 794017 Page 12 of 15
result of the event reported, giving additional
confirmation of on - going issues.
The notable absence of mould in poorly ventilated
area s (as above the cupboard) again confirm that the
event itself had little or no effect on mould infestation.
T his has been an on - going problem due to lack of
adequate ventilation and not caused by a single event
(leaving the pool unc overed).
M ould infesta tion & moisture related damage has been
caused more by steam derived from hot showers than
from the event itself, although the latter would have
increased the ambient humidity for a relatively short
period of time.
Sequence of Events : The areas of more su bstantial
damage and mould are directly related to shower
steam and water dripping from pool equipment.
Damage has been enabled by inadequate ventilation.
(Design defect)
Pre - existing Issues : There is no doubt that closing the
high - level windows significantly eliminated all crossflow
ventilation, but that, in and of itself is not the entire
cause of the observed damage .
Recommended extractor fans be fitted to help remove
humidity from the pool room and replace moisture
damaged trims with more appr opriate materials and
provide natural cross flow ventilation at the shower
recesses .
Complainant’s report (RT)
28 May 2020
RT is a licensed mechanical contractor specialising in
indoor pool dehumidification for about 18 years.
Completed a calculation using a program designed by
UK engineers who are one of the world’s largest heat
pump/dehumidification manufacturers in the world .
Reviewed material provided and noted pool building
renovated in February 2016 and risk report 21 Jun e
2016. Assume if there was mould this would’ve been
flagged as a health risk .
Noted from 29 September 29 until 4 October 2016 pool
cover left off while water was heat ed to 33°. Site
vacant for five days.
Considering the pool surface area and pool room siz e
and water temperature and room temperature says
under these conditions the evaporation rat e would’ve
been 1,536 litres over 5 days and natural ventilation
loss .2 I/hr which is a large amount of water being
released into the air .
With a dew point of 16.8 degrees at these conditions
there would have been condens ation on every surface
of this structure for the 5 days unattended and not
including the following 12 days in which this time an
Determination | Case number: 794017 Page 13 of 15
email was sent requesting the pool room be isolated
on 11/ 10/2016 (t o tal of 17 days of an iso l at ed room
with approx. 1500 litres of water that had evaporated
into the room.) This is assuming the cover was re
installed after the 5 days.
T he ventilated windows that were a part of the building
and or the new ventilated doors etc would not of made
any considerable difference as nat ural cross flow
ventilation (not mechanical ventilation) could not have
assisted in removing enough of the evaporated pool
water to make any considerable difference.
In my view this isolated time und er these conditions
there would have been mould forming as the relative
humidity would have been between 80 - 90% over these
17 days.
Building consultant report
(MC)
17 June 2021
Reviewed previous report and Australian S tandards
and C onstruction C odes .
Previous report shows that mould growth had
occurred, primarily in the bathrooms where showers
routinely cause a significant amount of steam to occur.
Whilst these are fitted with mechanical extract fans,
those fans only operate when the lights are switch ed
on.
The fact that mould has occurred clearly shows that
the amount of ventilation (mechanical fans plus
passive air circulation) is inadequate to prevent mould
infestation and thus does not meet the requirements of
Code quoted .
This is a design defect whic h leaves the shower rooms
inadequately ventilated.
It is not known when these shower rooms were
constructed but may have been part of the renovations
completed in March 2016 if not pre - existing.
At my site visit I was advised that former high - level
louvre windows in the pool area were replaced with
solid glass (“because of occupants feeling cold in
winter”).
This would have the immediate effect of significantly
reducing ventilation to the area, in particular, fresh air
from ou tside the building as required by regulations.
N o ventilation was fitted to replace that loss and the
only other ventilation was above the entrance door to
the interior of the building adjoining.
T his defect leaves the pool room non - compliant with
no ext ernal fresh air ventilation at all.
This change and consequent elimination of fresh
outside air ventilation was reported to have been made
at the time of renovations complet ed in March 2016.
Rust was not ed to have occurred in several places
Determination | Case number: 794017 Page 14 of 15
inside the po ol room itself. Whilst the full extent of
renovations is not precisely known, these steel
structures would almost certainly have been repainted
at the time of renovations being undertaken.
Rust, through paint, not only takes a considerable
period of time to occur, but also conclusively indicates
very moist atmospheric conditions, with potential
exposure also to corrosive pool chemicals.
I visited 12 October 2016 following the event when the
pool cover was inadvert ently left off. That was reported
to have occurred on 1 October 2016, only 11 days
before. Rust, through paint, could not have occurred in
such a short space of time, pointing to excessive
moisture in the pool room over time that was not due
to the event (cover left off). This would be entirely du e
to inadequate ventilation leaving heightened moisture
in the ambient air of the pool room.
Condensation in Buildings – Australian Building Codes
Board. This handbook is not a regulation nor standard
but offers guidance to designers and specifiers in
rel ation to achieving the relevant standards. In
particular it provides a Design Checklist which et al
states: “Understand the indoor climate of the building,
taking account of known activities and sources of
water vapour (worst case allowances will need to b e
assumed where the building occupancy is uncertain or
likely to change significantly over time). In a building
ventilated by out door air (the only known source),
without dehumidification, indoor water vapour levels
will inevitably be higher than those out doors.”
The installation (or absence thereof) suggests that
these considerations were overlook ed and thus not
implemented during the renovations. In fact, the
elimination of high - level louvre ventilation exac erbated
the internal moisture problems.
Specifi c Defects
5.2.1. Inadequate ventilation to shower rooms –
apparently since renovations in 2016.
5.2.2. Inadequate ventilation to pool room – reduced /
eliminated during renovations in 2016.
Building Standards are detailed.
Had those regulatory standard s been properly met,
there would not have been any mould infestation nor
rusting steelwork.
Both defects stem from inadequate design / installation
decisions.
Regulations are not prescriptive as to the passive
methods (louvres, etc) or mechanical equipmen t used
to achieve those standards. Those specific ations are
left to the building designer / mechanical engineer to
Determination | Case number: 794017 Page 15 of 15
determine to meet regulatory standards.
5.3 Refer to previous report which found that there was
a greater amount of mould in shower rooms rel ative to
the pool room. Had mould been specifically due to
moisture in the pool room there would have been more
mould in the pool room and less in the shower rooms.
In particular, no mould was identified in the areas of
the pool room where ventilation is l east and where
mould would typically occur first.
5.4. Had ventilation been to standard, leaving the pool
cover off for an extended period would not have
caused any damage. Given that ventilation is sub -
standard or non - compliant, I would have ex pected
the re to be condensation on cooler parts of the interior
building elements (e. g., steel work) but that would
have evaporated soon after and not caused any lasting
damage. In particular, mould relies on continuing
moisture and the pool cover event would not ha ve
provided that. Repeated showering replenishes
moisture regularly allowing moisture growt h.
Annotated photographs from 14 October 2016 .
3.4 Other relevant material considered and relied on
Parties’ submissions /emails and all attachments to all submissions/emails.
Parties’ expert reports.
Photographs.
Risk report and assessment reports.
Correspondence between the parties.