Home / AIG Australia Limited / Determination 790761

Determination 790761

Insurer limited liability for air-conditioning breakdown claim by excluding inverter PCB replacement and refrigerant drier installation

FirmAIG Australia Limited
Decided2021-12-20
ProductGeneral Insurance · Strata
OutcomeFor the firm
Amount awarded—
Non-financial loss—
Amount claimed—
SourceAFCA PDF

Summary

A strata corporation claimed under its machinery breakdown cover for an air-conditioning unit breakdown. AIG accepted the claim but excluded inverter PCB replacement and refrigerant drier installation costs, and AFCA decided the insurer was entitled to limit its liability.

The PCB was not shown to be damaged and refrigerant drier installation is an excluded alteration, overhaul or maintenance cost under the PDS exclusions and basis of settlement.

Issues

Subjects and remedies

related party investmentno remedy

Related

All AIG Australia Limited determinations · Find similar determinations

Text of the determination

Determination Case number 790761 Financial firm AIG Australia Limited Determination | Case number: 790761 Page 1 of 6 Case number: 790761 20 December 2021 1 Determination overview 1.1 Complaint The complainant brings this complaint on behalf of a strata corporation (insured) that holds a strata policy with the financial firm (insurer). The insured claimed for breakdown of an air- conditioning (AC) unit at the relevant apartment complex. The insurer accepted the claim but limited its liability to the cost of replacing the AC unit’s damaged components. It declined costs associated with replacing the AC unit’s inverter printed circuit board (PCB) and installing a refrigerant drier. It says:  there is no evidence inverter PCB is damaged  the drier is being replaced for maintenance purposes and is excluded by the policy. The insured maintains the insurer must cover those components although they are excluded. 1.2 Issues and key findings Is the insurer entitled to limit its liability? Yes. There is currently no evidence the AC unit’s inverter PCB is damaged, while the cost of installing a refrigerant drier is excluded. Why is the outcome fair? The policy’s product disclosure statement (PDS) forms the basis of the parties’ contact. The PDS details costs the insurer will cover and will not cover in a machinery breakdown claim. The costs which the insurer declined are not covered by the policy. It is unfair to require the insurer to cover costs that do not fall within the scope of cover provided by the policy. 1.3 Determination This determination is in favour of the insurer. The insurer is not required to take any further action in relation to the claim or complaint, other than to settle the portion of the claim it has accepted (if it has not yet done so). Determination | Case number: 790761 Page 2 of 6 2 Reasons for determination 2.1 Is the insurer entitled to limit its liability? Yes. There is currently no evidence the AC unit’s inverter PCB is damaged, while the cost of installing a refrigerant drier is excluded. Insured must prove a valid claim The insured must establish, on the balance of probabilities, it suffered a loss covered by the policy. This is known as a prima facie or valid claim. Once established, the onus is then on the insurer to prove an exclusion or condition applies if it seeks to deny or limit its liability for the loss. No dispute insured has a valid claim The insured’s policy is made up of a certificate of insurance (COI) and a PDS. The COI says the insured has machinery breakdown cover. Section 6 of the PDS sets down the relevant terms for this cover. There is no dispute the insured ’s AC unit broke down and the insurer accepts it has a valid claim for this. The dispute is ab out the insurer’s limit ation of liability for the claim. The insurer excluded costs associated with replacing the AC unit’s inverter PCB and installing a refrigerant drier from its settlement offer. Insurer says PCB inverter is undamaged and policy excludes refrigerant drier The insurer believes the inverter PCB is still functional, but it will reconsider its position if the insured provides proof it is damaged. However, it maintains that the cost of installing a refrigerant drier is excluded by the policy. The insurer says the refrigerant drier is meant to filter contaminants and moisture from the AC’s refrigeration circuit during operation. It acknowledges it is good practice to replace the drier but says this is essentially maintenance or service work rather than a repair. It says the cost of such work is excluded by exclusions 7.1 and 7.2, which state: 7. Specific Exclusions applying to Section 6 - Machinery Breakdown 7.1 We will not pay for any costs associated with:  cleaning or maintenance services;  alterations, additions, improvements or overhauls, adjustments or replacement of undamaged components whether carried out in the course of repairs or as a separate operation; … 7.2 We will not pay for the cost of repair or replacement of:  worn or spent belts, filters, refrigerant dryers, fuses, electric heating elements, electrical contacts, thermostats, thermostatic expansion valves, lamps gland packing, seals, cutting blades, commutators, slip rings, conducting brushes, chains, ropes, tyres, pressure switches, bearings, glass or ceramic components, fuel lamps, collecting brushes, belts, joints or non metallic parts and all operating media; Determination | Case number: 790761 Page 3 of 6 Insured says insurer most cover components it excluded The insured says it is entitled to cover ‘even though these parts are excluded’. It further says: Our contention is that an Air-Conditioner without an Air-Dryer and couplings will not operate, same as… a car engine without a vital co mponent is rendered unusable. The insured relies on the opinion of its electrician ‘ TKA ’ to support its position. In its 23 December 2020 email, TKA explained the need for a refrigerant drier as follows: Fitting a Suction Line Burnout Drier to any refrigeration system that has had a Burnt Out Compressor (Fused) is 'Good Practice' and is carried out on every compressor change of this type that our company and most others would do. The reasons behind fitting a Suction Line Burnout Drier are as follows: • Before commissioning a refrigeration / air conditioning system and after a burnt out compressor has been replaced - all measures are taken to clean the refrigeration circuit - including purging dry nitrogen through the system and deep evacuation prior to the commissioning. However to help protect the integrity of the new compressor - dryers are fitted to capture contaminants and moisture - (which can cause failure to the new compressor and other components within the refrigeration circuit). • As a warranty agent for [the relevant air-conditioning manufacturer] - If we attend to a compressor failure and we find that there is contamination or moisture in the system - Then the Warranty for this AC system becomes void - Therefore, We believe that it is mandatory that the Dryers are fitted to protect the following: 1. The AC system 2. The client - for premature breakdown of the asset after an expensive repair 3. [TKA] - the repairer from having to wear the costs of a void warranty claim (sic) In a later communication, TKA apparently said this: If Burnout Driers are not fitted to a refrigeration circuit when replacing a 'burnt out' compressor there is an extremely high chance that the new compressor will fail due to the carry over contamination caused by the catastrophic failure of the original compressor. Warranty for the new compressor would then become void from the manufacturer of that particular compressor because safety measures (ie Burnt Out Driers) were not knowingly fitted by the service technician. Therefore, the Driers, ball valves and copper fittings are an essential part of the compressor change. Determination | Case number: 790761 Page 4 of 6 I agree that it is 'Good Practice' to replace a drier when opening up a refrigeration system to carry out some repairs, however a burnt-out compressor is a completely different situation and consequently this repair must have a burnout drier fitted at time of repair. Policy covers repair or replacement of items that suffered loss or damage In addition to the exclusions cited by the insurer, clause 6 of the section 6 machinery breakdown cover also details what the insurer will and will not cover when accepting a machinery breakdown claim. The relevant extracts are set out in section 3.2 of this determination. In summary, the insurer will either repair or replace ‘the items that suffered loss or damage’ or pay a cash settlement for the same. The insurer will also cover ‘liquids or refrigerant gases… necessary to complete the repairs’ as well as ‘transport, labour and the on - site cost of parts’ . However, the insurer will not cover the cost of ‘ alterations, improvements, maintenance or overhauls carried out in conjunction with the repair or replacement ’ . No evidence AC unit’s existing inverter PCB is damaged There is no evidence the AC unit’s inverter PCB is damaged. In its 9 October 2020 report and quote, TKA acknowledges the inverter PCB may not require replacement although it was quoted for. The exchanged information shows the insured was asked to supply proof the inverter PCB is damaged, if it wants cover for its replacement. The insured does not appear to have provided such proof to date. Given this, I am satisfied the insurer is entitled to exclude costs associated with replacing the inverter PCB based on the available information. TKA’s evidence about the need for a refrigerant drier is vague and inconsistent TKA’s 9 October 2020 report recommend ed installation of a refrigerant drier to ‘reduce the chance’ of damage to the new compressor. However, its subsequent explanations for why the drier is needed seems somewhat inconsistent and confusing. One on hand, TKA says it is good practice. On the other hand, it seemed to imply it is mandatory. In its December 2020 email, TKA said it is ‘ good p ractice’ to install a drier because AC:  refrigeration circuits would be cleaned and purged when burnt compressors are replaced  driers are fitted to capture contaminants and moisture, which is designed to protect the integrity of a new compressor and preserve the AC unit’s warranty In the same email, TKA later says it is ‘mandatory’ to do so, to protect the client ’s investment , the warranty and itself from a potential legal liability. In a later email, TKA seems to suggest a drier is essentially always required when replacing a burnt-out compressor. New refrigerant drier is an overhaul of AC’s unit ability to filter contaminants On balance, I consider TKA is essentially saying an AC refrigeration circuit would be cleaned and purged as a matter of course when a compressor is replaced. As part of this exercise, a new refrigerant drier would invariably be installed. This is not because an existing one (if one exists) is necessarily damaged but rather, because it is ‘good practice’ to do so. It is ‘good practice’ as this would minimise the risks of potential:  carry over contamination caused by the prior compressor failure Determination | Case number: 790761 Page 5 of 6  problems or warranty issues arising in future. In short, the need for a refrigerant drier to be installed (in conjunction with the compressor repair) is to essentially add, improve or overhaul an AC unit’s ability to filter contaminants. This is to prevent potential problems or issues in future. Costs associated with installing a new refrigerant drier are excluded While I accept this may be good practice or even essential work as part of the compressor repair, the policy specifically excludes such work. The policy excludes costs associated with maintenance, refrigerant driers, or additions, improvements, overhauls or replacement of undamaged components carried out in conjunction with the necessary repairs. Given this, I am satisfied that the insurer is entitled to:  exclude costs associated with installing a refrigerant drier from its settlement  limit its liability for the claim to the portions of the claim it has previously accepted. Determination | Case number: 790761 Page 6 of 6 3 Supporting information 3.1 The AFCA process AFCA’s approach is based on fairness AFCA has determined this complaint based on what is fair in all the circumstances, having regard to:  the legal principles  applicable industry codes or guidance  good industry practice  previous decisions of AFCA or its predecessor schemes (which are not binding). The respective parties have completed a full exchange of the relevant information, and each party has had the opportunity to address any issues raised. I have reviewed and considered all of the information the parties have provided. While the parties have raised a number of issues in their submissions, I have restricted this determination to the issues that are relevant to the outcome. 3.2 Relevant policy wordings 6. Basis of Settlement 6.1 Breakdown In the event of a claim payable under Section 6 of the Policy for Breakdown of Machines or Boilers and Pressure Plant, (subject to any limitation or restriction applying under paragraph 6 - Automatic Temporary Cover, of Section 6 of the Policy) We will at Our option repair or replace the items that suffered loss or damage or pay a cash equivalent of such repair or replacement. We will also pay the cost of:  liquids or refrigerant gases or insulating oil necessary to complete the repairs;  transport, labour and the on-site cost of parts. Provided that: …  We will not pay for the cost of alterations, improvements, maintenance or overhauls carried out in conjunction with the repair or replacement.

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.