claim denial for cracking damage to house attributed to ground movement exclusion
Text of the determination
Determination
Case number 787756
Financial firm AAI Limited
Determination | Case number: 787756 Page 1 of 9
Case number: 787756 22 February 2022
1 Determination overview
1.1 Complaint
The complainant holds a home and contents insurance policy with the financial firm (insurer).
On 13 October 2020 she lodged a claim for cracking to the internal walls and chimney in the
house which had been noticed in 2019. She arranged for excavation and underpinning to
proceed.
The engineer she appointed to advise on the excavation and underpinning told her the
damage could have been caused by a leaking pipe, and she arranged for a specialist drain
test. The report from that test said the sewer pipe was in poor condition with breaks in several
locations, and this may have contributed to the cracking.
The insurer appointed a builder, consulting engineer and leak detection expert to report on
the cause of damage. It declined the claim, citing the engineer’s findings that g round
movement (an exclusion under the policy wording), seasonal variations and inadequate
footings had caused the damage.
The complainant says the insurer did not give her the opportunity to provide her own expert
report, lessening her chances of being successful in establishing the cause of her loss. In
response, the insurer appointed another engineer who agreed with the findings of the first
engineer, and the claim denial was upheld. The complainant disagrees with this decision.
She says the insurer has mishandled the claim and unreasonably delayed it. She seeks cover
for all repairs, as well as the cost of underpinning and concreting, to resolve the complaint.
1.2 Issues and key findings
Is the insurer entitled to deny the claim?
Yes. The available information shows the insurer has correctly declined the claim, since the
proximate cause of the loss was, on balance, the policy exclusion of ground movement.
Has the insurer mishandled and unreasonably delayed the claim?
No. The available information shows that the insurer handled the claim reasonably overall.
The available evidence in support of the insurer’s denial is detailed and compelling, and the
complainant was not materially disadvantaged.
Why is the outcome fair?
It would not be fair to require the insurer to pay a claim for damage not covered under the
policy.
1.3 Determination
This determination is in favour of the insurer. It is not required to take any further action.
Determination | Case number: 787756 Page 2 of 9
2 Reasons for determination
2.1 Is the insurer entitled to decline the claim?
Insurer’s expert reports say cause of damage not covered
As part of the initial claim process, the insurer appointed a building consultant (B), whose
report from 29 October 2021 said (in conclusion):
The cause of damage to property is a water leak from a broken combined earthenware sewer
line that runs between the insured's property and the adjoining property number … down the
centre of the walkway.
The building consultant engaged an engineer (H) whose report from 12 November 2020 says:
The damage that has occurred to the residence at the above property is typical of problems
that can occur as a result of differential settlement of adjacent footings and likely inadequate
footings. Differential settlement of the footings can occur as a result of seasonal changes in
the moisture content of the foundation material.
The insurer then sent a letter declining the claim on 31 December 2020, citing the following
policy exclusion:
Ground movement
erosion, vibration, subsidence, landslip, landslide, mudslide, collapse, shrinkage or any other
earth movement.
The complainant disputed this decision. The insurer sent another letter on 9 February 2021
upholding the denial of the claim, saying H found the damage was not due to the leaking
water pipe because there was no saturation found during the excavation.
However, it said it would appoint a second engineer to obtain a second opinion.
The second engineer (S) provided its first report dated 3 June 2021, after having attended the
property on 21 April. It commented on the reports already provided up to that point, and in
summary found:
the damage to the house has not been caused nor contributed to by the reported leak to
the sewer line to the east of the house
the damage to the house has not been caused nor contributed to by a single or definable
event
the damage to the subject building has been caused by footing movement as a result of
differential soil moisture content variations within the clay foundation soils caused by the
factors…, and particularly by the drying effect of the roots of the trees and vegetation in
close proximity to the subject building.
The panel is satisfied the insurer’s experts are suitably qualified to offer professional opinions
as to the cause of the loss.
Determination | Case number: 787756 Page 3 of 9
Complainant’s expert says leak was cause of damage
The complainant engaged an engineer (D) to seek advice during the excavation works
around the chimney footings and sideway. A full report was not provided, however D
reviewed the complainant’s plumber’s report and says (in an email dated 13 January 2021):
From 1998 up unto 2019 there was no cracking noticed.
If there was a general footing problem it would have been noticed over these 20 plus years.
All of a sudden there was excessive movement. There has to be a change in the foundations
causing movement.
During under pinning we found large rock floaters. We believed that these floaters most likely
moved due to the leaking pipes.
This in turn caused movement of the chimney and cracking of the walls etc.
The panel accepts the engineer is suitably qualified to offer a professional opinion as to the
cause of damage. However, the email is not detailed and does not include further specific
reasoning or data (as to the failure mechanism) to support the autho r’s conclusions.
A more detailed report was not requested by the complainant. This is because the insurer
offered to appoint a second engineer (S) after the complaint was lodged with AFCA.
Second engineer S agrees with first engineer H: leak did not cause damage
The insurer’s second engineer (S) provided a first report on 3 June 2021. S conducted a floor
level survey, which he stated validated his conclusion that the damage to the footings was not
consistent with a water leak. He noted that:
The clay foundation soils are expected to be of high plasticity and low permeability.
Therefore, any moisture escaping from a sewer or stormwater leak would not be expected to
penetrate the clay foundation soils.
In summary, S found the:
damage has been caused by footing movement caused by long term and ongoing
differential moisture content variations within the underlying reactive clay soils, lack of
adequate footings (to the house and underneath the chimney) and tree root drying
damage has not been caused by or contributed to by the sewer line or a single definable
event.
The complainant disputed these findings and sent a number of emails outlining her concerns
with the decision and reasoning used by S. S replied to these emails in the form of four
supplementary reports maintaining its position (the key points of this correspondence can be
found in section 3.2 of this determination).
The panel acknowledges the points raised by the complainant in these emails, but notes they
are not an ‘expert’ opinion, in the context of the facts of this claim. The complainant’s
engineer D sent another email on 21 September 2021. It says:
We hereby confirm that when we first visited the above residence in September 2020 we
found that there was extensive cracking throughout the house and that the chimney had
rotated towards the east. We immediately notified the owner of our belief that there was a
leaking pipe contributing to movem ent.
Determination | Case number: 787756 Page 4 of 9
Following investigations by R a leaking sewer was found on the east side of the
residence. It is our belief that the leaking pipe has caused the movement. The clays
supporting the footings or the floaters supporting the footings ha ve been subject to
alternate wetting and drying causing the supporting clays to powder.
This has then caused settlement and movement of the structure which has transferred
through the house by m embrane action of the roof.
S provided its final response (fourth supplementary report) on 1 October 2021, saying in
summary:
The Owner’s Engineer’ s premise that “alternate wetting and drying [is] causing the supporting
clays to powder” is not consistent with accepted principle of geotechnical behaviour and soil
mechanics.
For a clay soil to turn powder would require all the bonds between the soil particles to be
broken, this would only occur if the soil were completely desiccated (i.e. all the moisture were
removed and the moisture content of the soil were at or close to zero).
This would not happen in practice and could only be achieved in laboratory conditions (i.e. in
a ventilated oven over several days). For example, products made from clay and fired in a kiln
maintain the bonds between the soil particles hence they maintain their form.
The panel notes no further response was provided by D to refute S’s conclusions or to further
support the claim the clays had powdered.
On balance, proximate cause is not the leaking pipe
Damage can have more than one cause. When deciding whether the policy covers the
damage, we need to identify what the proximate cause of the damage was.
This is a question of fact depending on the circumstances in each complaint. The proximate
cause is not necessarily the first or last or the sole cause of the loss. It is the effective,
dominant or operative cause of the loss. If there are several causes operating at the same
time, AFCA will consider each one to determine which cause set the train of events in motion.
Courts have said that if one cause would have resulted in the harm in any case and the other
would not have done so in the absence of the first, then the first is the proximate cause.
The panel has reviewed all the available information provided by the complainant, her expert
and those of the insurer. In order to uphold the claim, the panel would need to be satisfied the
proximate (operative or dominant) cause of damage is the leaking drain/sewer line, as
opposed to the ground movement, inadequate footings and tree root drying as submitted by
the insurer and its experts.
Based on the information made available, the panel is not satisfied the complainant has
established, on balance, the proximate cause of damage was the leaking drain/sewer line.
This is because the insurer’s experts have provided detailed, comprehensive and methodical
reasoning to show the likely proximate cause was, on balance, long-term ground movement
due to seasonal changes in the moisture content of the foundation soils. The panel is satisfied
that even in the absence of the leaking pipe, the movement and cracking would still have
happened.
Determination | Case number: 787756 Page 5 of 9
That means the insurer is entitled to decline the claim.
2.2 Has insurer mishandled/unreasonably delayed the claim?
Claim handled reasonably overall
The complainant had excavation/underpinning works carried out in October 2019 and the
sewer line replacement in November 2019. She says after lodging the claim (and during the
insurer’s denial and internal review process) the insurer did not advise her she should obtain
her own expert report.
She says the insurer’s decision to decline came as a complete surprise to her and she was
given no indication the claim would not be accepted. She says this is because her engineer
and plumber advised her the leaking pipe had caused or contributed to the damage in the
house.
The available information shows the insurer did not specifically advise her she should obtain
such a report until 24 February 2021, the claim having been originally declined on 31
December 2020. However, the panel notes the insurer did agree to appoint another engineer
when the complaint was lodged with AFCA.
Having regard to the weight of the evidence that is available, the panel is satisfied in any case
that the insurer’s decision to decline the claim is based on compelling expert evidence. The
panel is not persuaded that any delay or omission in the complainant obtaining further
evidence to support her position will have changed that outcome. The insurer is entitled to
assess the claim and make a decision on it prior to inviting the complainant to engage her
own expert. The complainant has since had the opportunity to provide additional information.
Given the length of time for expert attendances to occur and reports to be submitted (which is
not necessarily within the insurer’s control) , the panel is also satisfied the timeframe within
which the claim decisions were made was not unreasonable in the circumstances.
2.3 Why is the outcome fair?
The outcome is fair because, on balance, the insurer has shown the proximate cause of
damage to be long term ground movement, an exclusion under the policy.
It would not be fair to require the insurer to accept liability for a claim which does not fall
within the scope of cover under the policy.
Determination | Case number: 787756 Page 6 of 9
3 Supporting information
3.1 The AFCA process
AFCA’s approach is based on fairness
AFCA has determined this complaint based on what is fair in all the circumstances, having
regard to:
the legal principles
applicable industry codes or guidance
good industry practice
previous decisions of AFCA or its predecessor schemes (which are not binding).
The respective parties have completed a full exchange of the relevant information, and each
party has had the opportunity to address any issues raised. We have reviewed and
considered all of the information the parties have provided.
While the parties have raised a number of issues in their submissions, we have restricted this
determination to the issues that are relevant to the outcome.
A panel determined this matter
Due to the nature of this complaint, we referred it to a panel for determination. The panel
includes:
an ombudsman
a member with significant experience in consumer and small business advocacy
a member with extensive experience as in the insurance industry.
We assess complaints on available information and circumstances
AFCA is not a court of law. We do not have the power to take or test evidence on oath, or to
require third parties to give evidence.
When we assess complaints, we consider:
available documents
the recollections of the parties
all relevant circumstances.
We give more weight to documents created at the time the events occurred. If there are no
relevant documents, we will decide what most likely occurred based on the available
information.
If there are conflicting recollections and these are evenly weighted, we may find that a claim
cannot be established.
Determination | Case number: 787756 Page 7 of 9
3.2 Supporting information
Record Key points
Complainant’s expert (R )
Drainage Report
13 - 10 - 2020
To determine whether leaking sewer or stormwater drains are
causing structural damage.
Notes underpinning works to brick chimney in the centre of the
house .
Sewer drain has fau l t s in quite a few of the joints .
There are leaking joints in the sewer and tree roots in the sewer
drain, damage to the stormwat er drain at the front of the property.
Leaking corroded spouting next door has contributed to the
movement o f the chimney.
Insurer ’s expert (B)
Building Report
29 - 10 - 2020
Notes external cracking to conc rete pavers on right - hand side of
property (on top of collapsed pipe which caused the damage).
Caus e of damage to property is water leak from a broken
combined earthen - ware sewer line running between insured
property and adjoining property
Condition of sewer line is quite poor – most joins misaligned along
entire length of line with numerous cracks and sever breaks
Recommends claim acceptance, quotes cost of repa irs at
$112,586.35
Insurer’s expert (E )
Engineer Report
12 - 11 - 2020
Large and most extensive cracks observed along chimney and
adjacent wall junctions.
Notes underpinning works underneath the chimney in progress.
Observes subfloor ground is dry and excavation for underpinning
the foundation material is dry.
Location or broken sewer pipe is outside the southeast bedroom
and lounge.
Stormwater drain is broken near the southeast corner of the
residence.
Soil classified as high reactive.
Concludes cracki ng is long term and likely due to seasonal
changes in the moisture content of foundation material and
inadequate footings .
Complainant’s expert (D )
Email
13 - 01 - 2021
Says from 1998 - 2019 there was no cracking noticed then
suddenly there was excessive movement – there has to be a
change in foundations causing movement – if there was a general
footing problem it would have been noticed over the past 20 years
Large rock floaters were found during underpinning – believes
most likely they moved due the leak ing pipes causing mo vement
of chimney and cra cking walls etc.
Insurer’s expert (S )
Engineer Report
03 - 06 - 2021 (attendance date
21 April 2021)
Reviews reports provided but notes majority of Discussion,
Conclusions and Recommendations are redacted.
Confirms opinion that soil is highly reactive.
A large tree was removed from the south of the property in 2016
Determination | Case number: 787756 Page 8 of 9
Record Key points
then a new one planted, apparently in late 2017.
Floor levels taken, maximum variation 54 mms, lowest point
towards southeast of the house.
Dept h of chim ney footing relati vely shallow - given the footings are
expected to be founded in clay soils, cannot identify how an
increase in moisture content could lead to settlement in this
footing
Damage has been caused by footing movement caused by long
term and ongoing differential moisture content variations within
the underlying reactive clay soils , lack of adequate footings (to the
house and underneat h the chimney ) and tree root drying
Damage has not been caus ed by or contributed to by the sewer
line or a sing le definable event.
Complainant email response
to S’s first report
09 - 06 - 2021
Conc erned about inclusions of extracts from H’s reports.
Queries accuracy of soil tests and S’s reliance on them
Queries soil classification inconsistencies.
Queries how S found chimney footings were noted as shallow
when not visible any more.
Says there is no reference to the large pieces or rock (floaters) in
S’s report.
Says there are inaccurate and contradictory comments about the
location and severity of cracking
Asks how th e drying effect of t r ee roots ‘particularly’ contributed to
the damage, says leaking sewer in closest proximity to the
damage has been dismissed.
Insurer’s expert (S )
Response to complainant emai l
(Supplementary report # 1)
18 - 06 - 2021
Says use of H’s report was only to provide additional information
that would not have been available through non - invasive testing –
would have reac hed same conclusion without them.
Says soil properties would not be expected to change in six
months. Soil moisture cont ent is not considered to be a good
measure of how much moisture the soil has absorbed. Says
Geotech findings are consistent with S’s expectations given the
site location.
Says classifications are not inconsistent – trees in the vicinity
affect the classificati ons
Says chimney footings were not measured but H’s photos are
clear and allow a reasonable estimate of footing dept h.
Says rock floaters would not have affected the reactivity of the
clay soils where they are located – not es D’s comments about the
rocks b ut he does not propose a mechanism about how the
leaking pipes moved them – so had no bearing on S’s findings
S notes no specific leak was report ed near the chimney, it is likely
the misalignment of the pipe joints has been caused by forum
movement – not g round movement caused the leaking pipes
Acknowled ges complainant saying no speci f ic roo t s have been
encountered but says this does not negate the fact that drying tree
Determination | Case number: 787756 Page 9 of 9
Record Key points
roots close to the site will affect soil moisture conditions on the
site.
Says the amoun t of water leaking would have to turn the soil to
mud and this will not happen if the footings are adequate.
Complain ant email response
to S’s Supplementary Report
# 1
05 - 07 - 2021
Says investigation is not independent.
Says H’s reports cannot be considered as they were altered –
insurer has refused to provide the soil test .
Says there is little site - specific data .
Says S has incorrectly identified leak location
Says drying effect of tree roots inconclusive.
Insurer’s expert (S )
Response to complainant email
(Supplementary report s # 2
and 3
22 - 07 - 2021 and 03 - 08 - 2021
Refutes complainant statement re independence.
Says the only information relied on from H was photographic
Restates position from first report – says is up to the insurer to
provide the test report
Says it has used best and most relevant data and met hodology
and complainant has provided no new information to alter its
findings.
Complainant’s expert (D )
Letter to complainant
17 - 09 - 2021
On discovering the extensive c racking throughout the house and
chimney rotation to the East, notified complainant there was
leaking pipe cont ributing to the movement and this was confirmed
by R’s report.
Says the clays supporting the footings or float ers of the floaters
supporting the footing have been subject to alternate wetting and
drying causing the supporting clays to powder.
This has then caused settlement and movement to the structure
which has transferred through the house vie membrane action of
the roof.
Insurer’s expert (S )
Response to D’s email and
information request from AFCA
- Supplementary report # 4
01 - 10 - 2021
Says it has not ignored submissions made about the basalt
boulder (floaters), reiterates this was not relevant to its opinion on
cause of damage.
Says D’s commen t about the clay powdering is not consistent with
the accepted principle of geotechnical behaviour and soil
mechanics – this could not occur in practice – could only be
achieved in laboratory conditions
Says it is unclear what mechanisms D refers to when t alking about
the membran e action of the roof, although sometime damage can
manifest in remote locations, it would most likely be through the
walls.
Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.