Home / Allianz Australia / Determination 780737
Determination 780737
Claim denial in part for movement and cracking damage to home caused by leaking stormwater pipe
Summary
The complainant claimed for movement and cracking damage to her home caused by a leaking stormwater pipe, and the insurer declined 80% of the damage citing excluded causes. AFCA found the leak caused the damage to the main dwelling and the insurer must settle the claim for that dwelling, but not the garage.
The insurer bore the onus to prove an exclusion applied and did not establish that inherent defects or wear and tear caused the main dwelling damage, so the leak-related claim under the water damage insuring clause was valid.
Issues
- Claim denial primary · upheld
“The insurer is liable to indemnify the complainant for the damage to the main dwelling; insurer has not established a policy exclusion applies.”
- Inadequate claim investigation secondary · upheld
“The panel does not accept a policy exclusion regarding defects can apply based on standards that were not applicable at the time of construction.”
Subjects and remedies
pay claim
Text of the determination
Determination
Case number 780737
Financial firm Allianz Australia Insurance Limited
Determination | Case number: 780737 Page 1 of 7
Case number: 780737 30 June 2022
1 Determination overview
1.1 Complaint
The complainant lodged a claim with the financial firm (insurer) for movement and cracking
damage to her home caused by a leaking stormwater pipe.
The insurer assessed and partially accepted the claim. However, it says the disputed cracking
damage was due to excluded causes, such as differential ground movement caused by
long-term and ongoing settlement of uncompacted fill in the northern section of the property.
The complainant disagrees with the insurer’s decision and says the leak contributed to the
movement damage. Accordingly, she seeks the insurer accepts the claim and repairs the
damage based on the quote she obtained.
1.2 Issues and key findings
Is the insurer liable for repairing the entire property?
Yes, but only to the main dwelling. This is because the available information shows the leak
caused the damage being claimed and the insurer has not established a policy exclusion
applies.
1.3 Determination
This determination is in favour of the complainant.
The insurer is required to settle the claim in the manner set out in section 2.1.
Determination | Case number: 780737 Page 2 of 7
2 Reasons for determination
2.1 Is the insurer liable for repairing the entire property?
Parties disagree on extent of damage covered under insured event for leaks
The complainant has the onus to establish on the balance of probabilities (that is more likely
than not) that the loss or damage falls within the insuring provision of the policy. This is
commonly known as a prima facie, or valid, claim.
It is not in dispute a stormwater pipe is leaking and has at least contributed to the damage
claimed. Therefore, the complainant has established a valid claim.
However, the insurer disagrees that this is the proximate (dominant, efficient or operative)
cause of the loss. The insurer considers the proximate cause is from excluded causes.
The insurer must prove on the balance of probabilities the damage was caused by a policy
exclusion or it is otherwise entitled to deny the claim.
Insurer considers 80% of claimed damage is not covered
On 17 January 2020, the complainant lodged the claim for movement and cracking damage.
The insurer estimates 20% of the damage was attributed to the stormwater. It says most of
the damage is because of ground movement over a long period. The insurer relies on general
exclusions for inherent defects, wear & tear and gradual deterioration to decline cover to 80%
of the damage. The complainant considers the leak caused the damage.
The insurer has relied upon engineering reports from C as well as other reports. C’s initial
report said the settlement occurred by the failure of the bearing capacity of the foundation
soils due to the stormwater leak. After a geotechnical report was obtained though, C revised
its conclusion. This is because it identified 1.3 metres of uncompacted fill material. C says this
is the proximate cause of the settlement and the leak only contributed 20% to the damage.
Further details of the expert reports are outlined in section 3.3 below.
Evidence shows the property has been affected by the leak
Having carefully considered the available expert information, the panel notes the following.
C’s initial report noticed a variance of -252mm towards the north-west corner of the main
dwelling. This is substantive.
Whilst C’s report identified some history of movement, there is nothing to show it was this
severe. According to C, the complainant has resided in the property from 1977, being 45
years. There is nothing to show it has experienced such volatile movements. Whilst some
previous repairs were noted, they appear minor in comparison to the cracks and movements
now identified.
C estimated the contribution of the damage by the 1.3 metres of uncompacted fill material to
be 80%. However, this appears inconsistent with the fact the property has not experienced
such significant movements in its history. Instead, this severe movement has only manifested
recently and with the discovery of the leak.
C has indicated the depth of the uncompacted fill material to be a defect and cited AS 2870 –
Residential slabs and footings. However, it is not clear if this standard was applicable at the
Determination | Case number: 780737 Page 3 of 7
time the property was constructed. The panel does not accept a policy exclusion regarding
defects or faulty workmanship can apply based on standards that were not applicable at the
time of construction. The standard cited by C does not make any reference that it applied on
or before 1977.
It is clear wear and tear, or gradual deterioration, does not apply. This only applies to damage
that occurred through ordinary, or natural use, over time. There is no dispute the leak has at
least contributed to the damage. This damage would not be through ordinary, or natural, use.
For the garage, C’s evidence is persuasive. The leak was not proximate to the garage. The
floor movements are nowhere near as severe. There was evidence of pre-existing trees.
These factors are consistent with C’s conclusion about the cause being unrelated to the leak.
Insurer liable for the damage to the main dwelling
The insurer is not liable for the garage damage. This is because the available information
does not show it was caused by the leaking pipe.
For the main dwelling, the panel accepts the complainants have established a valid claim. A
leak has been identified. This leak has caused the damage claimed. This is consistent with
the following:
the damage is proximate to the leak
the substantive settlement identified is proximate to the leak
the substantive movement and cracking damage were identified more recently and when
the leak was discovered
if the uncompacted fill was the sole proximate cause, then it is not clear why such
substantive damage was not evident in the property’s history
the geotechnical report shows the ground is very wet, consistent with the leak being a
cause
Whilst the uncompacted fill could have caused, or contributed, to the loss, the panel is not
persuaded this engages an exclusion. The insurer has not shown this was a defect, or faulty
workmanship, given no evidence was provided of the standard practices at the time of
construction.
For reasons explained, the panel is not persuaded wear and tear, or gradual deterioration,
applies. Neither is the panel persuaded the insurer has shown another exclusion applies by
reference to this fill.
Therefore, the insurer is liable to indemnify the complainant for the damage to the main
dwelling. In the event the insurer decides to cash settle this claim, it should do so based on
the following:
engage an independent structural engineer to inspect the property and provide a full scope
of works for all the required repairs – engineer should be one agreed to by the parties and
whose costs are payable by the insurer
obtain a current actionable quote from an independent repairer agreed to by the parties for
damage to the main dwelling
cash settle the complainant based on this quote, plus a 15% uplift of the repair quote to
allow for the transfer of risk and the likely possibility of variances to the work
interest is not payable given the settlement will be based on a current quote
If the parties are unable to agree on the quantum, the complainant can lodge a new complaint
at AFCA for a decision on this point.
Determination | Case number: 780737 Page 4 of 7
Determination | Case number: 780737 Page 5 of 7
3 Supporting information
3.1 The AFCA process
AFCA’ s approach is based on fairness
AFCA has determined this complaint based on what is fair in all the circumstances, having
regard to:
the legal principles
applicable industry codes or guidance
good industry practice
previous decisions of AFCA or its predecessor schemes (which are not binding).
The respective parties have completed a full exchange of the relevant information, and each
party has had the opportunity to address any issues raised. We have reviewed and
considered all of the information the parties have provided.
While the parties have raised a number of issues in their submissions, we have restricted this
determination to the issues that are relevant to the outcome.
A panel determined this matter
Due to the nature of this complaint, we referred it to a panel for determination. The panel
includes:
an ombudsman
a member with significant experience in consumer and small business advocacy
a member with extensive experience in the insurance industry.
We assess complaints on available information and circumstances
AFCA is not a court of law. We do not have the power to take or test evidence on oath, or to
require third parties to give evidence.
When we assess complaints, we consider:
available documents
the recollections of the parties
all relevant circumstances.
We give more weight to documents created at the time the events occurred. If there are no
relevant documents, we will decide what most likely occurred based on the available
information.
If there are conflicting recollections and these are evenly weighted, we may find that a claim
cannot be established.
Determination | Case number: 780737 Page 6 of 7
3.2 Terms of the policy
Date Action
Insured events we will pay 11. Water or other liquid damage
(Applicable whether you have buildings and/or contents cover)
We will pay for loss or damage which results directly from the
bursting, leaking, discharging or overflowing of:
fixed apparat us,
dishwashers,
washing machines,
fixed tanks,
fixed pipes,
waterbeds, or
aquariums designed to hold more than 20 litres of water.
When we will not pay a claim
under your policy
This policy does not cover loss, liability, injury or damage:
…
f. Wear and tear
arising out of depreciation, gradual deterioration, wear and tear;
g. Inherent defects
caused directly or indirectly through inherent defects, faulty
design, structural defects or poor workmanship;
3.3 Expert reports
Record Key points
Insurer’s engineer (CR)
Report
15 - 04 - 2020
Several 0.5 - 1mm wide cracks observed in the wall and ceiling linings at
the south section of the dwelling. Several 1 - 10mm wide cracks in the
wall and ceiling linings at the north section of the dwelling.
This indicates the footing movement mainly occurred at the nort h
section of the dwelling.
Signs of previous repair indicate the dwelling cracked and was repaired
in the past.
Laundry door jammed. This is consi stent with differential ground
movement.
There are a 5mm wide stepped crack to the eastern brick wall of the
garage, and a 2mm wide stepped crack to the western brick wall of the
garage.
There are no articulations joints within the brick walls of the gara ge.
The floor level survey indicates the northern section of the dwelling has
relatively settled.
The location of the maximum settlement coincides with the location of
the pipe leak.
The survey indic ates the north - eastern side of the garage has settled
re lative to the remainder of the structure.
This settlement is consistent with the location of pre - existing trees at
Determination | Case number: 780737 Page 7 of 7
the eastern side of the garage.
Based on loc al knowledge and experience, the soil profile at the site is
of reactive clay founding soils. Alt hough this was not tested .
Pipe leak tests indicate the stormwater pipes do not slope away from
the dwelling to discharge rainwater to the legal point of discharge.
Rainwat er backflows towards the dwelling and escapes from the
downpipe at the northwest co rner of the dwelling.
The pipe leak saturated and compromised the bearing capacity of the
foundation soils and caused settlement in the northwest section of the
dwelling over the long term.
Insurer’s engineer (CR)
Supplement ary report
24 - 07 - 2020
The primary cause of subsidence is the consolidation settlement of the
fill material.
It is likely the stormwat er drain leading to the west side of the house
was originally installed correctly but has shifted and subsided with the
house. The drain now gra des back towards the house.
The excess water from this leaking drain lowers the strength and
friction within the fill material, and, in turn, adds to the settlement and
consolidation of this material.
It can be assumed the subsidence of the front northern part of this
house has been occurring since the house was first constructed.
The subsidence has caused some plumbing and drainage problems to
develop. These problems have exacerbated the subsidence and
distortion of the house slab.
This house has been bu ilt incorrectly on a site with a substantial depth
of loose fill material covering the northern part of the property.
The consolidation settlement of the filling has caused the house to
subside.
The drains now leak as a result of the subsidence.
Insurer ’s plumber (LP)
Report
04 - 03 - 2020
Ran a hose down the rear downpipe. Immediately, water started
backing up the pipe on opposite corner, and ran out onto ground.
When it rains, all rainwater runs out onto ground here, at the corner of
the house which has sunk.
All sewer is on the opposite corner to damaged corner, and runs down
past the garage, into the laneway behind.
The street stormwater outlet only trickled, while most wat er ran back
through pipe to the damaged corner.
Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.