Home / Westpac / Determination 779375

Determination 779375

Pool shell damage claim declined under exclusions

FirmWestpac
Decided2021-07-21
ProductGeneral Insurance · Home building and contents
OutcomeFor the complainant
Amount awarded—
Non-financial loss—
Amount claimed—
SourceAFCA PDF

Summary

The complainant's pool shell was damaged after a burst water main, and the insurer declined the claim under the defects and earth movement exclusions. AFCA found the claim valid and the exclusions not established, and ordered the insurer to accept the claim (repair or cash settle at quotes plus 15%) and reimburse expert report costs.

The insurer bears the onus of proving an exclusion applies and did not provide compelling evidence for its expert's alternative causes.

Issues

Subjects and remedies

home or building damagepay claimpay compensation

Related

All Westpac determinations · Find similar determinations

Text of the determination

Determination Case number 779375 Financial firm Westpac General Insurance Limited Determination | Case number: 779375 Page 1 of 8 Case number: 779375 20 July 2021 1 Determination overview 1.1 Complaint The complainant has a home building and contents policy (policy) with the financial firm (insurer). He noticed his pool was losing water and on investigation it was found the pool‟s shell had distorted and cracked. On 20 August 2019, a claim was lodged for the damage to the pool. The insurer declined the claim and says the policy excludes cover for loss or damage caused by defects in design, structure, materials, workmanship or construction as well as earth or soil movement. The complainant maintains the damage to the pool is due to a burst water main pipe which occurred some six weeks or so before the damage to the pool was noted. T he complainant disagrees with the insurer‟s decision to decline the claim . 1.2 Issues and key findings Has the complainant established a valid claim? Yes. On the balance of probabilities, the burst water pipe caused the damage to the pool which falls within cover available under the insured event „Escape of liquid‟. Is the insurer entitled to decline the claim under the policy? No. The insurer has not established, on the balance or probabilities, that the damage claimed is due to circumstances excluded from cover under the policy. 1.3 Determination This determination is in favour of the complainant. The insurer is to accept the claim and authorise repairs to the pool. Alternatively, the insurer can cash settle the claim based on the repair quotes sourced by the complainant with a 15% mark up to allow for contingencies and the transfer of risk resulting from the claim being cash settled. Subject to the complainant providing the insurer with proof of payment, the insurer is to reimburse the complainant for costs he has incurred in arranging the expert reports in support of his claim. Determination | Case number: 779375 Page 2 of 8 2 Reasons for determination 2.1 Has the complainant established a valid claim? The policy provides cover for insured events The policy covers the insured property against for loss or damage arising from insured events, including Escape of liquid. Cover under the policy is subject to the conditions, limitations and exclusions specified in the product disclosure statement (PDS). The relevant policy provisions have been provided in section 3 of this determination. The complainant has established a valid claim The complainant bears the onus to establish, on balance, the loss claimed is caused by one or more of the listed insured events. This is known as establishing a prima facie claim. Cover under the escape of liquid insured event is triggered when there is loss or damage because of a sudden and accidental escape of liquid from any fixed pipe, fixed tank, waterbed, fish tank, or fixed item used to hold liquid. Cover under this insured event also extends to the reasonable exploratory costs incurred in locating the source of the damage, if the insurer accepts a claim for damage under the escape of liquid event. Circumstances of the loss There is no dispute a water mains pipe at the front of the property, some six meters away from the pool, burst. This was discovered on 16 June 2019. The complainant witnessed the strength of the pressure from the burst mains pipe located outside the front of the insured property and says he felt the vibration in the ground standing some 10m away. Some six weeks after this event, the complainant noticed the pool had started to lose water (water levels decreasing). The pool had been installed in 2011 with no issues noted until August 2019. The complainant arranged some investigations into the loss of water from the pool through consultants „G‟ who had installed the pool in 2011, „CP, the pool‟s manufacturer and „F” to complete a pool test report. These investigations eliminated the pool‟s h ydrostatic valve as the cause of or a contributing factor for the loss of water. However, a crack to the pool shell was identified on the wall closest to the front of the property (where burst water mains pipe was located) by F and temporary repairs were completed to the crack. The complainant lodged the claim seeking cover for the cost to repair the pool under the policy. The experts have different opinions The insurer appointed engineers „ SW ‟ to assess the cause and extent of the damage subject of the claim. The insurer relies on several reports provided by SW as a basis to decline the claim. SW maintains the damage to the pool is not the result of the burst mains water pipe. Rather, it says it is more likely due to issues with manufacture of the pool ‟s fibreglass shell and possibly long-term deterioration to the pool wall due to long term reactive clay movements, pool usage, inadequate pool tread support and long-term weather/soil exposure. Determination | Case number: 779375 Page 3 of 8 The complainant dissatisfied with SW‟s findings appointed engineer „RK‟ to complete an assessment of the cause and extent of the damage. I note „C , who has completed the reports from RK, is a member of the Standards Committee for the revision of AS1838 and AS1839, the two Australian Standards governing the construction of fibreglass pools. C has also over the previous 36 years investigated a significant number of pools, both concrete and fibreglass, for both insurance companies and state government departments. RK noted the pool was installed in 2011 and had eight years of trouble free operation until the burst water mains pipe event. RK considered the damage to the pool is consistent with an external event. RK considered, the only logical explanation is that the damage to the pool was the result of the burst water mains pipe 6m uphill of the pool. RK says:  the burst water main released water under very high pressure impacting on the north wall of the pool  this water would have exploited any available route and the sheer volume of water under pressure would create its own ever-increasing size of corridor for the passage of the water. As the corridor increased in diameter, so the pressure on the pool would increase  the sand cement backfill at the back of the fibreglass shell would offer some resistance, but not for long.  fibreglass has the strength of steel, but the stiffness of timber. It will therefore deflect significantly under a burst of high-water pressure without breaking. The resultant deflection would lead to the development of high stress at a point of stiffness eventually the shell would crack. I note pool specialists „MK‟, who also completed an assessment of the pool concluded the damage was consistent with being the result of an external event and was not the result of faulty installation or manufacturing defect. I acknowledge SW does not agree with RK‟s findings an d says it is unlikely that the damage to the pool shell is the result of the leaking water mains pipe. This is because of the nature of the clay soils at the site, the strength/pressure of the escape of liquid would only be similar to a tap on full and there would have only been a limited amount of water that escaped as the pipe was repaired the same day. However, I am not satisfied SW has provided any compelling evidence in support of these views. There is no information as to how long the leak may have been occurring for before it finally broke ground. I note SW and therefore the insurer when given the opportunity to make further inquiries with the relevant water department about the burst pipe event, formed the view that this would not be helpful. Further, I note when given the opportunity to undertake further exploratory works between the location of the leak and the pool, again SW and therefore the insurer, declined and said this would not be of much assistance and would be a costly exercise. With res pect to the pressure of the escape of liquid, I note SW‟s view s are in direct conflict with RK, however for which no evidence is provided. I note the complainant witnessed the escape of liquid and confirms it was escaping under very high pressure, so much so that he felt the ground vibrating some 10m away from the leaking water mains pipe. Complainant has established a valid claim After considering all the information, I find the complainant‟s appointed consultants to be the more persuasive and consistent with the circumstances subject of the claim. I am satisfied, on the balance of probabilities that is more likely than not, that the damage to the pool is the result of the burst water main pipe event. Determination | Case number: 779375 Page 4 of 8 Accordingly, I determine the complainant has established, on balance, a valid claim for the damage to the pool within the terms of the policy. The onus therefore rests with the insurer to show, on balance, an entitlement to decline the claim in line with one or more of the policy exclusions. 2.2 Is the insurer entitled to decline the claim? The insurer has not established an entitlement to decline the claim The insurer relies upon several policy exclusions, which have been listed in the section 3 below. It says the damage claimed is excluded from cover because it is likely due to defects relating to manufacture or and/or installation of the pool shell. Also, it is possible but less likely that the damage is because of long term deterioration of the pool shell (wall) because of reactive clays and associated earth movement, inadequate pool tread support and long-term weather/soil exposure. As indicated under section 2.1, I am not satisfied the insurer has established either defects in the pool manufacture or installation were a cause of damage or that it was due to earth movement. There is an absence of any evidence establishing any defects in the manufacture of the pool shell or its installation. There is no evidence which establishes any ongoing or gradual earth movement to the area or damage consistent with exposure to the elements. The insurer was afforded the opportunity to source further information in support of its position, however, it elected not to. In the absence of such supporting information, I am satisfied the evidence and opinions provided by RK, G and CP, details of which are provided in section 3, are the more compelling and consistent with the physical location and circumstances leading up to when the damage to the pool was discovered. Accordingly, I determine the insurer has not established, on balance, that it can rely on any of the quoted policy exclusions to decline the complainant‟s claim under the policy. The insurer is to accept the complainant‟s claim and authorise repairs in line with its obligations under the policy. Alternatively, the insurer may choose to cash settle the claim, if so, this is to be based on quotes obtained by the complainant with a 15% mark up to allow for contingencies and the transfer of risk arising from the claim being cash settled. Subject to the complainant providing the insurer with proof of payment, the insurer is to reimburse the complainant for costs he has incurred in arranging the expert reports in support of his claim. Explain why the outcome is fair The outcome is fair in all the circumstances because the insurer has not provided enough information to show that the likely cause of the damage is excluded under its policy. The complainant ‟ s information provides a more plausible explanation for the cause of the damage. The insurer chose not to obtain further information when allowed the opportunity, and as such it is fair to require the insurer to cover the complainant for the damage to the pool under the claim. Determination | Case number: 779375 Page 5 of 8 3 Supporting information 3.1 The AFCA process AFCA’s approach is based on fair ness AFCA has determined this complaint based on what is fair in all the circumstances, having regard to:  the legal principles  applicable industry codes or guidance  good industry practice  previous decisions of AFCA or its predecessor schemes (which are not binding). The respective parties have completed a full exchange of the relevant information, and each party has had the opportunity to address any issues raised. We have reviewed and considered all the information the parties have provided. While the parties have raised a number of issues in their submissions, we have restricted this determination to the issues that are relevant to the outcome. We assess complaints on available information and circumstances AFCA is not a court of law. We do not have the power to take or test evidence on oath, or to require third parties to give evidence. When we assess complaints, we consider:  available documents  the recollections of the parties  all relevant circumstances. We give more weight to documents created at the time the events occurred. If there are no relevant documents, we will decide what most likely occurred based on the available information. If there are conflicting recollections and these are evenly weighted, we may find that a claim cannot be established. 3.2 PDS/SPDS and Expert Information Product Disclosure Statement/ Supplementary Product Disclosure Statement Document Wording PDS/ SPDS Escape of Liquid Covered. Loss or damage caused by the sudden and accidental escape of liquid from any fixed pipe, fixed tank, waterbed, fish tank, or fixed item used Determination | Case number: 779375 Page 6 of 8 to hold liquid. We will also pay reasonable exploratory costs in locating the source of the damage, provided we have agreed to pay for the loss or damage c aused by the escape of liquid. Not covered.  Loss, damage or repairs to the item from which the liquid escaped, and if the liquid escaped from a shower recess, the cost of re - tiling the walls or floor of the shower recess,  repair or replacement of undamaged parts of your building and/or contents to match property that has been repaired or replaced, or  loss or damage caused by gradual escape of liquid which is eviden t and which you fail to rectify. … General Exclusions Your policy does not cover any loss or damage that is caused by or arises from: Maintenance and building. • defects in design, structure, materials, workmanship or construction… Wear and tear, and environmental conditions. • wear and tear, gradual deterioration, or fading, • …. atmospheric conditions, • earth or soil movement (other than earthquake) including landslide, subsidence, erosion or heave, • settling, expansion, shrinkage or vibration, Determination | Case number: 779375 Page 7 of 8 • hydrostatic pressure, or • tree roots Expert Information Record Key points Complainant’s expert (F ) Pool technician Report (undated)  Structural Test Pool Shell FAILED  Hydrostatic Valve Test PASSED  RESULT Located a structural crack in the fibreglass shell on the shallow end wall of the pool. Complainant’s expert (MK ) Report (undated)  …my pro fessional opinion that this type of damage is caused by an external event and not a result of faulty installation or any manufacturing defects Complainant’s expert (C P ) Email - m a n ufacturer (undated)  … all records indicate that pool number 31724 was built to [manufacturer] specifications for materials and workmanship  [manufacturer] has built over 40,000 pools over the last 40 years and in checking our warranty database, we receive approx. 0.2% warranty claims per year  Of the warranty claims received i n the last 12 months, only 4 relate to the type of damage consistent with the[complainants] pool in pools installed since 2011, and one of those claims was the [complainants] pool  [manufacturer] does not have a substantive pattern of pools suffering from structural cracks in the location of the [complainants] pool in pools installed since 2011 Complaints expert (RK ) Engineers Reports 7 May 2020 and 22 November 2019  ..suggestion has been made that the event of June 2019 was of little consequence and that in all probability the problem was a manufacturing or design issue. It must be accepted by all parties that a pool built in 2011 suddenly became a problem in 2019 fol lowing a burst pressurised waternain (hydrant) in June 2019. A burst hydrant is not a storm wat er line. It is not a sewer line. It is water under high pressure  The distortion of the north wall would distress the north - east  corner of the wall and the power of the water would creat e pressure on both the north and eastern walls in excess of normal static pressure. It is a pressurised wat ernain. If a person stood in front of it, it would blow the person off their feet. Clearly, this is an event.  …we suggest tha t the water pressure arising from a burst hydrant would seriously damage any pool. Financial firm’s expert (SW )  …most probable cause of the localised wall damage is Determination | Case number: 779375 Page 8 of 8 Record Key points Engineer Report 13 November 2019 ….considred to be related to…localised manufacturing/ fault.design to the pool wall (most likely) …long term deterioration…due to long term reactive clay movements and …long term weather /soil exposure Financial firm’s expert (SW ) Engineer Report 13 December 2019  ….supplied engineering report did not prov ide a feasible mechanism to explain how the leak had caused the  subject damage to the northern wall of the subject pool. Financial firm’s expert (SW ) Engineer Report 27 July 2020  The additional information provided in the Engineering Report and the Pool Manufacturer's email, do not offer  any new evidence to confirm that the supply water main leak has caused damage to the subject northern pool  wall.  …Our conclusions remain largely unchanged, Financial firm’s expert (SW ) Engineer Report 4 December 2020  The damage to the pool has not been caused nor c o ntributed to by the reported escape of liquid from the water main..  “Wash - out” of soil material around the pool is not expected to have occurred  …refer to previously issued [SW] reports where the causes of damage are summarised…

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.