Home / Allianz Australia / Determination 775507

Determination 775507

Insurer declined storm damage claims for three residential dwellings

FirmAllianz Australia
Decided2021-10-18
ProductGeneral Insurance · Other general
OutcomeFor the firm
Amount awarded—
Non-financial loss—
Amount claimed$15,620
SourceAFCA PDF

Summary

The complainant, an investor with a policy covering three residential dwellings, claimed storm damage after 27 July 2020. AFCA found the damage was caused by inherent defects, poor workmanship, wear and tear and inadequate maintenance, which are excluded, and the insurer was entitled to decline the claims.

Storm and water damage cover is excluded where water penetrates through structural defects, poor workmanship, gradual deterioration, wear and tear or inadequate maintenance, and the insurer's consultants' evidence was more persuasive than the complainant's.

Issues

Subjects and remedies

business interruptionhome or building damagenatural disasterno remedy

Related

All Allianz Australia determinations · Find similar determinations

Text of the determination

Determination Case number 775507 Financial firm Allianz Australia Insurance Limited Determination | Case number: 775507 Page 1 of 7 Case number: 775507 18 October 2021 1 Determination overview 1.1 Complaint The complainant holds a residential investor insurance policy (policy) with the financial firm (insurer). The policy covers three residential dwellings (37, 37A and 37B). On 12 August 2020, three claims were lodged, one each for the insured properties, seeking cover for storm damage. The insurer has declined the claims. The insurer says the damage is because of inherent defects, poor workmanship, gradual deterioration, wear and tear and inadequate maintenance which are expressly excluded from cover. The complainant dispu tes the insurer’s assessment of its liability and is seeking cover for the damage to the insured properties. 1.2 Issues and key findings Is the insurer entitled to decline the claims? Yes. The insurer is entitled to decline the claims because damage to the insured properties is most likely the result of inherent defects, poor workmanship, gradual deterioration, wear and tear and inadequate maintenance, which is excluded under the policy. 1.3 Determination This determination is in favour of the insurer. The insurer is entitled to decline the claim and is not required to any further action in the circumstances. Determination | Case number: 775507 Page 2 of 7 2 Reasons for determination 2.1 Is the insurer entitled to decline the claims? The policy is an insured events contract of insurance The policy covers the insured property against loss or damage caused by one or more the listed insured events, including ‘ Storm, rainwater or run-off ’ and ‘Water or other liquid damage’ . Cover under these benefits is subject to the conditions, limitations and exclusions specified in the product disclosure statement (PDS). The complainant has established valid claims The available information shows that all three properties covered under the policy have presented with some stormwater ingress consistent with having occurred on 27 July 2020, the date of the claimed storm event. There is also evidence of property 37B having water damage consistent with water escaping the bathroom shower. The policy covers loss or damage caused by the storm, rainwater and water or other liquid. As the damage is consistent with storm damage the onus rests with the insurer to show, on the balance of probabilities, it is entitled to decline the claims in line with the policy exclusions specified in the PDS. The parties’ consultants’ have provided conflicting information The complainant relies on a letter and a repair tax invoice provided by his appointed consultant ‘IB’ to support his position the damage to the t hree properties is the result of the storm event on 27 July 2020. I note IB has not separate not separate and/or identify the said damage and associated repairs separately for each of the insured properties. Rather, IB’s findings and repair costs have all been discussed together by way of combined commentary. IB attended the three properties on 28 July 2020. IB noted many other houses in the area with storm damage showing lifted and blown away roof sheeting. IB says many of the three insured properties’ r oof sheets had also lifted causing water to leak into the various areas of the houses damaging ceiling plasterboards, downlights, electrical cables and paint. IB says:  the gutters were fairly maintained with the gutters almost free of debris  a good number of the roof sheets were lifted with some sheets and apron flashings too damaged to be salvaged  heavy rainfall exceeded the standard capacity of the roof sheets  winds drove rainwater over the upstream ends of the roof sheets. IB has provided a tax invoice dated 5 August 2020 in the amount of $15,620.00 for repairs said to have been completed in July 2020. The repairs included repair and replacing roof sheets, flashings, gyprock, light fixtures, damaged electric cables and re-painting damaged areas. The ins ured appointed loss adjusters ‘C’, building and roof consultants ‘J’ and plumbing consultants ‘GP’ to inspect the insured properties to determine the extent and cause of the damage claimed. These consultants inspected each of the insured buildings and have provided reports on each of the insured properties. Determination | Case number: 775507 Page 3 of 7 Insured property 37 The complainant is seeking cover for patching and repainting of approximately 10m2 of ceiling to the front entrance foyer. C attended the property on 28 August 2020 and says the tenant confirmed that t he damage was first discovered around 27 July 2020 when they noticed water leaking above the front door. Further, that from an outside inspection it appeared to be because of a failed membrane on the guttering above. J has provided a report dated 16 September 2020 which says the roof leak damage to the first floor in because of non-compliant installation of the entire small roof area. It noted the patchy silicone seal on the balcony skirting tiles and flashings were not watertight. A spray test of the front balcony failed and showed water to leak from the ceiling both inside and outside the entry door. With regards to the roof, J confirms that there was no evidence of any storm related damage. When it rains, water is leaking over the laps of the roof sheeting and through holes in the roofing. The balcony and the foyer roof are under pitched and do not comply with section AS3500.5 of the NCC Building Standards (Standards) for the installation of Custom Orb Sheeting. There was no evidence of a storm created opening. Property 37A C attended the property on 28 August 2020 and says the tenant confirmed that the damage was first discovered around 27 July 2020 when they noticed water leaking above the front door. GP has provided a report dated 16 September 2020 and says the damage to the ceiling inside the front door is below the balcony. GP inspected the balcony and found no silicone seal and a skirting tile had fallen off on the corner next to the sliding door. There was cracking noted to the blue board rendered wall near the fallen skirting tile. The front balcony was spray tested and this showed water leaked from the ceiling around the downlight. GP says the waterproofing had failed in the corner where the cracking and fallen skirting tile were found. J in its report of 16 Septem ber 2020 concurs with GP’s findings. J also notes that the roof slope was under -pitched, and that it did not comply with the Standards for the installation of Custom Orb roof sheeting. The roof above the rear alfresco area was also under-pitched and did not comply with the Standards. J found a leak between the wall flashing and the brick wall due to the separation of silicon sealant and non-compliant wall flashing. J says there was no evidence of any physical damage or a storm created opening to the roof and says the cause for the water leak is faulty construction, design and workmanship. Property 37B C ’s attendance confirmed there was water damage to this insured building in the areas of the hallway, garage and bathroom. The tenant they noted stormwater ingress above the front door on 27 July 2020. GP in its report on the insured building confirms there is water damage inside the garage and hallway below the main bathroom. GP inspected the balcony and found no silicone seal with the blue boards sideway moving and possibly not sealed. GP noted the hallway flooring to main bathroom is water damaged as well as the shower door. Determination | Case number: 775507 Page 4 of 7 GP spray tested the balcony which failed, and water leaked from the ceiling in the garage. Flood tested the ensuite shower and main bathroom shower, which both failed. Dampness started to appear at the bathroom door in area of the damage. GP says the waterproofing had failed causing issues at the door and ceiling below. J says the damage to the garage ceiling was due to the non-compliant under pitched roof for Custom Orb sheeting that had been installed. This in combination with water that is being dispersed by the down pipe spreader located on the roof above the balcony is overloading the roof area above the garage. The causes water to leak over the roof sheeting and enter the garage through the non-compliant flashings. J says water is also entering the garage through a large gap in the wall linings of the main first floor brick wall and the first-floor balcony wall. Water damage to the lounge room ceiling was due to water leaking between the flashing and the brick wall due to the separation of silicon sealant with possible secondary entry point through gaps around a window located on the first floor. The insurer’s consultants did not find any evidence of repairs or replacement of the roof materials during their attendance, such as a colour variance in new roof sheeting. This is what would have been expected if any roof sheeting had been replaced as claimed. The insurer’s evidence is more persuasive I have considered the several reports from the consultants and find the information provided by C, J and GP to be the more persuasive. This is because their reports and opinions are supported by strong evidence in the form of detailed documentation of the different areas of damage as well as from where the leaks are occurring. This includes clear and supporting photographic evidence of the damage and concerns found with the insured buildings. I am not satisfied the available information shows that stormwater ingress is the result of damage or openings created by the storm subject of the claims. The issues such as failure of waterproofing resulting in the buildings not being water tight are consistent with having occurred over time due to wear, tear, gradual deterioration, inherent defects and a lack of maintenance. The policy does not cover stormwater ingress damage unless it is due to a single insured event and has entered through a storm created opening. The policy excludes loss or damage caused by water entering because of water seeping, percolating and penetrating due to poor workmanship, gradual deterioration, wear and tear and inadequate maintenance. Further, I have considered the evidence from IB, however, in addition to lacking detail and persuasive supporting evidence, it seems to be inconsistent with the evidence from the insurer. IB claims to have completed the repairs in July 2020 with a repair invoice dated in August 2020. The evidence from GP and J after their attendance in September 2020 indicates the damage had not been repaired and was still present. J and GP have both advised in their opinion there was no evidence of recent repairs to the roofs nor internally. This is supported by the many photos provided of the damage and which supports in some areas, in particular the garage, the damage appeared dated and the result of multiple water ingress events. I note the concerns raised by the complainant about the insurer’s delay in arranging for it consultants to attend and this is why he had to arrange his own consultant to complete repairs. I am not satisfied the evidence supports this, given the complainant appointed IB the Determination | Case number: 775507 Page 5 of 7 day after the claim was lodged and IB says he commenced repairs on 30 July 2020, two days after claim lodgement. The insurer is entitled to decline the claims For the above reasons, I am satisfied the damage to the three insured buildings is more likely because of the identified inherent defects, poor workmanship, gradual deterioration, wear and tear and inadequate maintenance, which is excluded under the policy. Accordingly, I determine the insurer is entitled to decline the claims in line with the policy provisions. Why is the outcome fair? The outcome is fair because the available evidence establishes the damage to the insured buildings is because of circumstances which the policy specifically and generally excludes from cover. The complainant has not been successful in showing the damage claimed is covered under the policy and as such it is fair in all the circumstances that the insurer be permitted to rely on the policy provisions to decline the claims. Determination | Case number: 775507 Page 6 of 7 3 Supporting information 3.1 The AFCA process AFCA’s approach is based on fairness AFCA has determined this complaint based on what is fair in all the circumstances, having regard to:  the legal principles  applicable industry codes or guidance  good industry practice  previous decisions of AFCA or its predecessor schemes (which are not binding). The respective parties have completed a full exchange of the relevant information, and each party has had the opportunity to address any issues raised. We have reviewed and considered all the information the parties have provided. While the parties have raised a number of issues in their submissions, we have restricted this determination to the issues that are relevant to the outcome. 3.2 Relevant policy provisions 9. Storm, rainwater or run-off (Applicable whether you have buildings and/or contents cover) We will pay for loss or damage caused by storm, rainwater or run-off. We will not pay for loss or damage: a. … f. to the external paintwork or other exterior coatings of the buildings caused by rainwater; g. caused by water seeping, percolating or otherwise penetrating into the buildings as a result of: • structural defects; • faulty design of the buildings; • faulty workmanship in the construction of the buildings; or • your failure to adequately maintain the buildings; Determination | Case number: 775507 Page 7 of 7 h. caused by wind, rainwater, hail or snow entering the buildings through an open window or door or any opening not made by the storm, unless the loss or damage is caused by run- off; or … …. We will not pay a claim under your policy 1. This policy does not cover loss, liability, injury or damage: f. Wear and tear arising out of depreciation, gradual deterioration, wear and tear; g. Inherent defects caused directly or indirectly through inherent defects, faulty design, structural defects or poor workmanship; … 2. Unless we state differently in your policy schedule, we will not pay for: b. any loss or damage which is not caused directly by one of the insured events; … 12. Water or other liquid damage (Applicable whether you have buildings and/or contents cover) We will not pay: a. for loss or damage caused as a result of the gradual escape of liquid over a period of time:  where you or a reasonable person in the circumstances could be expected to have been aware of such gradual escape of liquid;  due to lack of maintenance, wear and tear, or neglect; or  caused by water escaping from a shower base, shower recess, shower alcove or the walls surrounding the shower;

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.