Home / IAG / Determination 769437

Determination 769437

Home insurance claim for ensuite bathroom water damage declined

FirmIAG
Decided2021-08-20
ProductGeneral Insurance · Home building and contents
OutcomeFor the complainant in part
Amount awarded$2,062
Non-financial loss—
Amount claimed$18,000
SourceAFCA PDF

Summary

The complainant sought about $18,000 for water damage to an ensuite bathroom after a leak. AFCA upheld the insurer's decline of the ensuite damage but ordered payment of $2,061.71 for the main bathroom damage the insurer had offered.

An insurer relying on a gradual deterioration or faulty workmanship exclusion must prove on the balance of probabilities that the exclusion applies.

Issues

Subjects and remedies

home or building damagepay claim

Related

All IAG determinations · Find similar determinations

Text of the determination

Determination Case number 769437 Financial firm Insurance Australia Limited Determination | Case number: 769437 Page 1 of 9 Case number: 769437 3 August 2021 1 Determination overview 1.1 Complaint The complainant holds a private plan home insurance policy (the policy) with the financial firm (the insurer). He lodged a claim under the policy in August 2020 advising that water was leaking from the upstairs (ensuite) bathroom to the downstairs (main) bathroom causing damage. The insurer agreed to accept water damage to the main bathroom on a goodwill basis, but not damage to the ensuite bathroom from which the water is escaping. This is because the insurer considers water had been leaking from the ensuite bathroom from before occupation by the complainant and before the policy commenced in January 2020. The insurer also says it is entitled to its position because the leak is a result of gradual deterioration and defective building works, both of which are excluded under the policy. The complainant is dissatisfied with this decision. While he acknowledges that there was a previous leak to the ensuite bathroom, he says the leak was not active at the time he moved in. He says he then used the ensuite shower on a regular basis, during which time it did not leak, up until the leak became apparent in August 2020 at which time he lodged the claim. To resolve the complaint, the complainant says the insurer should cash settle him for about $18,000. The case manager provided the parties with a preliminary assessment on the issues in dispute. The preliminary assessment was in favour of the insurer. As the complainant has not acccepted the preliminary assessment , the complaint has been referred to me for determination . 1.2 Issues and key findings Is the insurer entitled to decline the claim for damage to the ensuite bathroom? The available information establishes on the balance of probabilities the damage to the ensuite bathroom was directly or indirectly caused by or arose out of gradual deterioration. As this cause of damage is excluded from cover, the insurer is entitled to decline the claim. Furthermore, the grout in the ensuite shower required repair in December 2019, and the complainant knew about this and failed to fix it or arrange to have it fixed before the damage occurred after the policy commenced. Why is the outcome fair? The outcome is fair as the insurer is entitled to rely on its expert opinion and its policy terms to decline the claim for the ensuite bathroom. Further it has offered to pay for damage to the main bathroom. Determination | Case number: 769437 Page 2 of 9 1.3 Determination This determination is substantially in favour of the insurer. Should the complainant accept this determination then within seven days of acceptance, the insurer is to pay to the complainant $2,061.71. Otherwise, the insurer is not required to take any further action in relation to the claim or the complaint. Determination | Case number: 769437 Page 3 of 9 2 Reasons for determination I have decided this complaint based on what is fair in all the circumstances, having regard to legal principles, applicable industry codes or guidance, good industry practice and previous relevant determinations of AFCA or predecessor schemes (which are not binding). I have considered all the material submitted by the parties, both before and after the preliminary assessment. I am satisfied that the documentation I have relied on has been provided to both parties. The parties have raised numerous issues in their submissions to AFCA. However, commentary in this determination is restricted to those issues considered relevant to the outcome. After the preliminary assessment was rejected, the complainant sent material which had been provided earlier and essentially reiterated his position. 2.1 Is the insurer entitled to decline the claim for damage to the ensuite bathroom? Material and submissions considered The complainant must establish on the balance of probabilities he has suffered a loss caused by an event to which the policy responds. This is known as a prima facie or valid claim. In the context of this claim he must establish he sustained accidental damage during the period of insurance. The insurer accepts that a water leak event has occurred, and the complainant has identified damage following the event. Once so established, the onus shifts to the insurer to prove on the balance of probabilities that an exclusion applies if it seeks to deny or limit its liability for the loss. In the context of this claim the insurer must establish the damage was directly or indirectly caused by or arose out of faulty workmanship or gradual deterioration. Extracts from the relevant policy terms are set out in supporting section 3.2 of this determination. The insurer says it will accept the claim for resulting damages to the main downstairs bathroom. It is prepared to cash settle the complainant for this damage less the excess. It says it is unable to cover the damage to the upstairs ensuite due to pre-existing damage, gradual deterioration and faulty works. The insurer submits it does not cover any claim arising directly or indirectly from faulty workmanship, wear and tear and gradual deterioration. It says it is entitled to rely on expert reports which show a flood test was conducted on the tiled shower base and the base failed. It argues there were also issues with the grouting and builders identified damage to the second-floor bearers, joists, yellow tongue flooring and timber wall framing. It says the available information establishes damage occurred over time as the timbers show rot. The complainant has rectified the damage. He asks for partial payment for the upstairs ensuite bathroom because: > he does not disclaim pre-existing damage or faulty work from the previous owner > materials used were acceptable construction materials applicable at the time of building Determination | Case number: 769437 Page 4 of 9 > once he commenced repairs he found waterproofing membrane in the shower recess > he fixed the ceiling in the main bathroom in early January 2020 > there was no active leak from the ensuite in January 2020 > the moisture test failed at the time of sale because the shower had been in use > once he and his family moved in, the ensuite was consistently used for about seven months and there was no damage despite consistent use for about seven months > if the leak has been occurring over time the damage downstairs would be much greater > it is only in August 2020 he was aware of the leak and the video shows strong water flow through the wall petition upstairs > there was no indication of an active leak until the claim was lodged in August 2020. The complainant reviewed the reports relied on by the insurer. He reiterates the ensuite was used constantly for seven months. He says after he discovered the leak he investigated the second-floor subfloor and found no extensive damage but minor damage to existing bearers and joists. He notes the wall frame bottom plate was significantly rotten for about 800 mm either side. He agrees the wall linings were plasterboard instead of villa board and there were no signs of waterproofing but said waterproofing was found between the tile and the plaster as well as the tiles to the floor. He says these issues could not have been identified when he inspected the property before purchase. He agrees water staining has travelled back up the plasterboard wall lining and agrees there is evidence of a previous leak but where there is evidence of extensive damage he refers to the August 2020 video which shows extensive water flows. Extracts from the reports relied on by the parties are set out in supporting section 3.3 of this determination. Damage has occurred over time I carefully considered the submissions by both parties and their expert reports and photographs and videos provided. I am satisfied the insurer is entitled to rely on the policy exclusions. This is because: > in August 2020, the shower base did not pass the flood test > water leaked from the shower base to the floor below because the grouting between the floor and wall tiles have moved and cracked > in December 2019 the complainant’s dilapidation report identified damage to the grout > in December 2019 moisture tests failed in all showers. This may have been because they had been used within the previous hour but in view of the damage below, it may have also been because the ensuite shower was already leaking. > in December 2019 the ceiling in the main bathroom below the ensuite required patching and painting. I am satisfied the damage has occurred over time on the balance of probabilities because of the opinion of the first builder (IB) engaged by the insurer and his photographs of the timbers which show rot. While I acknowledge the extent of water shown in the video relied on by the complainant, the video was taken by IB when he inspected the property in August 2020. Nonetheless, having taken the video, inspected the damage and the subfloor, IB was still of the opinion that the damage occurred over time. I acknowledge the insurer ’s opinion from a second builder (CF) who inspected the damage in October 2020. He says the water was coming from the ensuite for a period of months rather Determination | Case number: 769437 Page 5 of 9 than years. However, I do not find this opinion sufficiently compelling in view of the opinion from IB and the photographs of the timber. Further, there is some ambivalence in the report as CF admits the exact date of the initial water ingress from the ensuite shower cannot be determined. The complainant argues if the leak has been occurring over time the damage downstairs would be much greater. However, there is conflicting evidence about how much the ensuite bathroom was used. Although the complainant says it was used twice a day for seven months, nonetheless he told both IB in August 2020 and CF in October 2020 that when using the ensuite shower for the first time water went into the bathroom below and the shower was not used since. I find contemporaneous statements are usually more accurate. Further, due to the cause of damage and the nature of the damage, I accept the leak became worse and the damage became apparent over time as the grouting in the ensuite shower and the timber and materials below and near the ensuite shower continued to deteriorate. Taking all matters into account I am satisfied the available information establishes on the balance of probabilities the damage has occurred through gradual deterioration. As this cause of damage is excluded from cover, the insurer is entitled to decline the claim. Grouting required repair in December 2019 Further, I am satisfied the insurer is entitled to rely on the other policy exclusion. This is because it is not in dispute the grout in the ensuite shower required repair in December 2019, and the complainant knew about this and failed to fix it or arrange to have it fixed before the damage occurred after the policy commenced. IB has provided a scope of works. IB costed the repair to the main bathroom at $2,561.71. The policy excess is $500. Should the complainant accept this determination then within seven days of acceptance, the insurer is to pay to the complainant $2,061.71. Otherwise, the insurer is not required to take any further action in relation to the claim or the complaint. 2.2 Why is the outcome fair? The outcome is fair as the insurer is entitled to rely on its expert opinion and its policy terms to decline the claim. Further it has offered to pay for damage to the main bathroom. Determination | Case number: 769437 Page 6 of 9 3 Supporting information 3.1 Process AFCA’s approach to this complaint It is an accepted principle of general insurance law that the insured bears the onus to establish on the balance of probabilities that they have suffered a loss caused by an event to which the policy responds. This is known as a prima facie or valid claim. Once so established, the onus shifts to the insurer to prove on the balance of probabilities that an exclusion applies if it seeks to deny or limit its liability for the loss. How we assess complaints AFCA is not a court of law. We do not have the power to take or test evidence on oath, or to require third parties to give evidence. When we assess complaints, we consider available documents, the recollections of the parties, and all relevant circumstances. We give more weight to documents created at the time the events occurred. If there is no relevant documentation, we will decide what is most likely to have occurred based on the information provided to us. If there are conflicting recollections and these are evenly weighted, we may find that a claim cannot be established. 3.2 Relevant policy terms The relevant policy extracts are referred to in the correspondence between the parties and in the insurer’s Notice of Response. Both the policy document and the Notice of Response have been exchanged with the complainant. Product disclosure statement (PDS) page 13: General definitions applying to words We use in this Plan … Accident means a sudden, unexpected and unintended event which:  you did not intend or expect; and  a reasonable person in your position and with your knowledge and experience would not have expected. ‘ Accidental ’ and ‘ Accidentally ’ have corresponding meanings … PDS page 14: … Period of Insurance means the period shown as the ‘Period of Insurance’ on Your Certificate of Insurance PDS page 16: What you are insured against This policy insures you against accidental damage… occurring during the period of insurance Determination | Case number: 769437 Page 7 of 9 … What is not insured This policy does not insure You against: … 2. damage directly or indirectly caused by or arising out of: … a structural fault, faulty design or faulty workmanship if You knew, or ought to have known about the structural fault, faulty design or faulty workmanship and failed to fix it or arrange to have it fixed before the damage occurred or commenced to occur … PDS page 17: … 11. wear, tear, rust corrosion or gradual deterioration … PDS page 20: Additional Benefits The following additional benefits are in addition to any sums insured shown on the Certificate of Insurance for ‘Building’ and ‘Contents’. … Escape of liquid If liquid overflows, leaks or bursts from a fixed system at your home during the period of insurance and damages or is likely to damage insured property, we pay for the reasonable cost to investigate the cause of damage or likely damage. We pay up to $2,500 for this benefit. We do not pay to repair or replace a faulty part identified by the investigation, but we pay the cost to repair damage directly caused by the investigation. We only pay this benefit if building is shown on the certificate of insurance 3.3 Extracts from material relied on by the parties Date Action Dilapidation report (AI) 2 December 2019  Main bat hroom requires patch and paint due to ceiling damage. Plaster moisture damage not ed due to tastic not working.  Bedroom 2 ensuite has cracked floor tiles and wall tiles suggest full replacement.  Bedroom 3 ensuite slight gaps in wall to floor tile suggest that floor was laid after walls incorrect process.  Bedroom 3 ensuite minor damage to tile grout. Hard to determine extent due to grout being black - suggest Determination | Case number: 769437 Page 8 of 9 regrout as good measure.  Moisture test failed in all showers due to being used within the previous hour. Insurer’s plumber (AP) 21 August 2020  Inspected, photographed and tested bathroom/ensuite .  F lood test performed. Shower base did not pass flood test. Water leak downstairs after about 30 seconds.  Concluded shower leak is from movement to the shower. The grouting between the floor and wall tiles has moved and cracked.  B elieve there is no wet seal to the shower of bathroom. Insurer’s builder (IB) 21 August 2020  Inspected and photographed 21 August 2020.  Complainant advised he purchased property early 2020. While using upstairs shower for the first - time water leaked into the bathroom ceiling below.  Complainant accessed the second - floor subfloor and wall frames and found extensive damage to the timber bearers, wall frames and yellow tongue flooring which was pre - existing. Wall linings of plasterboard not v illa board and no signs of waterproof ing .  IB notes and photographs damage to the second - floor bearers, joists, yellow tongue flooring and timber wall framing. Says these damages have happened over a long period of time as the timbers have signs of rot.  Water staining appears to be travelling back up the plasterboard wall ceiling.  Bathroom ceiling downstairs has signs of water staining and paint peeling. Timber window architrave has minor cracking.  Complainant to wat erproof the bathroom which will require the removal of the existing bat hroom.  Repair estimate $20, 688.75  Concluded due to the long - term shower base leak property damaged – due to the damages present, believe this is a pre - existing issue before the insured purchased a property in early 2020. Insurer’s building consultant (CF) 21 October 2020  Inspected and photographed property 12 October 2020 and reviewed parties’ reports .  Comp lainant told him he purchased the property in March 2020 but had lived there since early January 2020 and when using the shower for the first time he saw wat er going int o the bat hroom below and has not used the shower since.  Inspected inside the roof cavity and noted the floor under the e nsuite is standard particleboard floor.  Timber softwood wall frame and particleboard floor of the ensuite displayed staining consistent with water ingress. Determination | Case number: 769437 Page 9 of 9  Says standard particleboard should not be used when there is risk of contact with water.  Used digi tal moisture meter and materials in a dry state.  Says the use of standard core plasterboard wall linings within the ensuite is defective building work.  Noted staining to the wall frames, deep floor joist and backing of the plasterboard wall linings of the ensuite but saw no advanced deterioration of these materials which would indicate long - term water ingress.  Grout between all floor tiles in the shower enclosure is deteriorated and displaced with separation bet ween the wall / floor tiles indicating movement of the deep floor joist which is typical with this type of construction. The deteriorated grout is a maintenanc e related item.  Removed the gr a t e from the floor waste of the shower enclosure but could not locate a waterproofing membrane which is defective building work .  E xact date of the initial water ingress from the ens uite shower will not be able to be determined but in the absence of advanced deterioration of materials particularly the plasterboard wall linings of the ens uite and the plasterboard ceili ng linings of the bathroom below indicat es short - term wat er ingress ( months ) from the ensuite shower as opposed to damage that has been occurring for an extended period ( years ). 3.4 Other relevant material considered and relied on  Parties’ submissions /emails and all attachments to all submissions/emails.  Parties’ expert reports and quotations.  Photographs and videos.  Correspondence between the parties.

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.