Home / IAG / Determination 768750

Determination 768750

Denial of commercial building damage claim (slab collapse) on basis damage occurred before policy inception

FirmIAG
Decided2021-10-11
ProductGeneral Insurance · Business / commercial
OutcomeFor the complainant in part
Amount awarded$64,691
Non-financial loss$2,500
Amount claimed—
SourceAFCA PDF

Summary

The unit trust complainants claimed for damage to a commercial building's slab caused by leaking saltwater fish tanks, which the insurer denied as pre-dating the policy. AFCA found the claim established for the period on risk and ordered the insurer to pay 80% of the loss including loss of rent, interest, and $2,500 non-financial loss.

Damage occurred during the policy period and the insurer was on risk for about 4.5 years, so a fair apportionment of 80% of the total damage applies.

Issues

Subjects and remedies

business interruptionhome or building damagesmall businesspay claimpay interestpay non financial loss

Related

All IAG determinations · Find similar determinations

Text of the determination

Determination Case number 768750 Financial firm Insurance Australia Limited Determination | Case number: 768750 Page 2 of 11 Case number: 768750 7 October 2021 1 Determination overview 1.1 Complaint The complainants hold a commercial investment property policy with the financial firm (insurer), which provides cover for damage to the property. The complaint concerns the denial of the complainants’ claim for damage sustained to their commercial building when the first-floor cement slab collapsed in May 2020. The slab was damaged from salt water leaking gradually from a fish-tank. The complainants say the damage to the property commenced after the original inception of the policy in 2016. The insurer relies on its engineers in disputing this issue, and concludes the damage occurred prior to policy inception. 1.2 Issues and key findings Have the complainants established a prima facie claim? Yes. The insurer is on risk for damage occurring in the period from 31 January 2016 to 14 May 2020. What amount is payable by the Insurer? The insurer is liable for 80% for the damage to property being a reasonable apportionment for its period on risk. The total damage payable including loss of rent is $64,691.31. Is there an entitlement to compensation for non-financial loss? Yes, there was undue delay in appointing an engineer and the reasons given for denying the claim provided no basis for a complete denial of coverage. An amount of $2,500 is awarded. Does section 46 of the Insurance Contracts Act 1984 (the Act) assist? No. The section has no application. Why is the outcome fair? Damage was initially gradual and continued for the 4.5 years the insurer was on risk and 80% represents a fair apportionment of the total damage. 1.3 Determination This determination is substantially in favour of the Complainant. The Insurer is to pay the amount of $64,691.31 and interest under section 57 of the Insurance Contracts Act 1984 (Cth) from 31 July 2020 to date of payment The Insurer is to pay the amount of $2,500 as compensation for non-financial loss. Determination | Case number: 768750 Page 3 of 11 2 Reasons for determination 2.1 Have the complainants established a prima facie claim? Yes. The insurer is not entitled to deny the claim. The complainants have established that damage or a major part of the damage occurred during the period that the Insurer was on risk, namely from 31 January 2016 to 14 May 2020. Onus on complainant to establish valid claim When lodging a claim with the insurer, the onus first lies with the complainants to establish on the balance of probabilities (that is more likely than not) a valid claim under the policy, otherwise known as a prima facie claim. In this circumstance, the onus is on the complainants to establish the damage occurred during the period of cover. Once the complainants have established a prima facie claim then the onus shifts to the insurer to establish a reason the policy may not apply. Policy covers damage occurring during period of insurance The policy provides cover for loss, destruction or damage to the property that occurs at the insured address during the period that the insurer is on risk. The policy was first incepted on 30 January 2016 and then renewed annually including on 30 January 2020. The collapse of the first floor occurred on or about 14 May 2020 but the evidence is clear that ongoing damage to the slab had been occurring for some time. Damage caused by leaking fish tanks There is no argument from either party or the experts that the damage was caused by the leaking saltwater fish tanks on the floor above where the ceiling collapsed. However, the parties disagree on the timeframe as to when damage occurred, and the method used to reach this timeframe. Expert Evidence as to when damage occurred The insurer, relying on its engineers F and V, concludes the leak likely commenced no later than 2013. This is based on deterministic chloride diffusion modelling completed by the engineers. V confirms its results to the modelling were based on the following assumptions:  the saltwater tanks were installed in the restaurant in 2008  the concrete grade is Fe 25MPa  the concrete is a general purpose (GP) cement-based concrete  the concrete has design cover to top (12mm 0) reinforcing steel = 25mm. It says, based on this information, the corrosion of the top reinforcement slab would be within 5 years (the tanks were installed in 2008). Further, the delamination and spalling of the slab would likely occur between 2-4 years after the corrosion initiation. The complainant’s engineer (P) d iscussed its concerns with the accuracy of the modelling as it was based on assumptions rather than any site-specific data. Determination | Case number: 768750 Page 4 of 11 P concludes “there is insufficient site -specific data and far too many unknown variables involved to support the current corrosion modelling results.” The expert evidence does rely on assumptions. Neither the reports of the complainant nor the insurer give an accurate determination made on characteristics, such as the grade of cement or size of the slab or extent of the steel reinforcement. One assumption of the Insurer expert which is difficult to accept is that leaking commenced immediately upon installation of the saltwater tanks in 2008. There seems no reason why the process of leaking could not have started at any time in the period between 2008 and 2020. In fact, by implication of the Insurer’s expert the damage started at the latest by about 2013 (2020 minus 7 years). If so then a 4 year period of corrosion would mean damage was still occurring when the Insurer came on risk in 2016. V’s model may be reasonable but the results are dictated by the data input and assumptions uploaded. I agree with P’s concerns regarding the modelling results , but the complainant s ha ve not provided any information to establish a different timefram e. P itself is unable to provide a more definitive timeframe and recommends more testing be completed to obtain accurate data for the modelling. When did damage occur The Insurer submits: “ any further damage caused by the ongoing leak after policy inception in 2016 was negligible compared to the damage that had already occurred prior to that time. Even if the leak had been stopped in 2016 at the time the CGU policy was taken up, the first floor slab was already so significantly damaged that significant excavation works would have been required to rectify the damage caused by the leaking fish tank”. This submission is not supported by the expert evidence. The damage in 2015/16 may well have been substantially latent but it was certainly not even noticed by th e Complainant’s pre - purchase building inspection expert. It seems plain that further damage occurred and some 4 years later the ceiling collapsed. It is simply not feasible to assert that all the damage had occurred before policy inception in January 2016 and that the floor was then stable but mysteriously collapsed 4 years later. Furthermore, the leaking of saltwater by itself is not damage. Nor is corrosion by itself necessarily damage. Damage commenced at some point when delamination and spalling occurred and there was a weakening of the concrete slab. The evidence viewed objectively is persuasive that we are unable to be certain when damage actually began but that the damage was ongoing until the ceiling collapse. The insurer is liable for the whole of the damage or alternatively for the proportion of damage that occurred in the period from 30 January 2016 to 14 May 2020. There is also a reasonable basis to submit that the moment of the collapse during the 2020 policy period was the major part of the damage especially as there was consequential damage to the whole ceiling and the floor below. Further it seems likely that the overall repair costs were likely increased by the collapse. 2.2 What amount is payable by the Insurer? The Insurer has based its denial of indemnity on the argument that the damage had occurred before it came on risk. The Insurer has not sought to rely on any exclusions in the policy such as corrosion and or gradual deterioration. I am unable to speculate on the reasons for this. I deal below with the issue as to the timing and apportionment of damage. The Complainant has held the policy for approximately four and a half years. It does seem reasonable that some part of the damage may have occurred before 31 January 2016. However, it is unreasonable for an Insurer to suggest it is not on risk for any part of the damage and not on risk for the actual collapse of the slab which could well have caused loss Determination | Case number: 768750 Page 5 of 11 of life. In my assessment I consider a fair apportionment to the Insurer for that four and a half year period is for 80% of the total damage. By email dated 30 September 2021 the Insurer confirmed its understanding of the quantum of the loss as follows:  Repairs to Chinese restaurant (main claim) = $38,343.75 (80% is $30,675)  Repairs to Aluminium business (secondary claim) = $23,625.80 (80 % is $18,900.64)  Loss of rent = $15,115.67 The 80% total of the first two items is $49,575.64. The loss of rent component is presumably covered by virtue of the section 2, loss of income section in the policy. Page 22 of the policy says “ we will cover you if the business is interrupted or interfered with as a result of a physical loss…occurring during the period of insurance”. The Insurer does not dispute the calculation. I propose to allow the Complainant 80% of the repair costs on the basis as explained above, that 20% of the damage occurred before the insurance commenced. However, the loss of income was triggered by the physical collapse which occurred in 2020. Accordingly, I see no reason to discount the loss of rent component. The loss of rent was confined to the period of insurance. Accordingly, the total loss payable for the damage and loss of rent is $64,691.31. The Insurer should pay interest under the Insurance Contracts Act on the amount of $64,691.31 for the period from 31 July 2020 to date of payment. The Complainant may well have rights against whichever insurer was on risk in 2015, being the first year in which the Complainant became the owner of the property. 2.3 Is compensation payable for non-financial loss Under AFCA rule D3.3 AFCA can award compensation of up to $5400 for non-financial loss where there is an unusual degree of physical inconvenience or time taken to resolve a situation. The complainant here is not an individual but a unit trust. In light of the above findings the position taken by the Insurer on indemnity was unreasonable and undoubtedly caused additional expense to the Complainant. Further the Insurer failed to have its own engineer attend the site until several weeks after the collapse of the slab. The Complainant was required to proceed with urgent repairs without any assurance as to indemnity. This made subsequent investigation and examination of the site more difficult. The Insurer is to pay the amount of $2,5000 as compensation for non-financial loss. 2.4 Does section 46 of the Act assist the complainants? Section 46 of the Act does not apply in the circumstances The complainants raised whether section 46 of the Act applies in the circumstances as the complainant was not aware of the damage prior to May 2020. Section 46(2) of the Act says: Where, at the time when the contract was entered into, the insured was not aware of, and a reasonable person in the circumstances could not be expected to have been aware of, the defect or imperfection, the insurer may not rely on a provision included in the contract that has the effect of limiting or excluding the insurer's liability under the contract by reference to the condition, at a time before the contract was entered into, of the thing. Determination | Case number: 768750 Page 6 of 11 The insurer is not relying on a policy provision or exclusion to deny the claim. Rather the insurer is relying on the argument that damage commenced prior to when the complainant first took out insurance with it. In these circumstances, section 46(2) of the Act does not apply. 2.5 Why is the outcome fair? The outcome provided is fair in the circumstances Damage was initially gradual and continued for the 4.5 years the insurer was on risk and 80% represents a fair apportionment of the total damage. Determination | Case number: 768750 Page 7 of 11 3 Supporting information 3.1 The AFCA process AFCA’s approach is based on fairness AFCA has determined this complaint based on what is fair in all the circumstances, having regard to:  the legal principles  applicable industry codes or guidance  good industry practice  previous decisions of AFCA or its predecessor schemes (which are not binding). The respective parties have completed a full exchange of the relevant information, and each party has had the opportunity to address any issues raised. We have reviewed and considered all of the information the parties have provided. While the parties have raised a number of issues in their submissions, we have restricted this determination to the issues that are relevant to the outcome. We assess complaints on available information and circumstances AFCA is not a court of law. We do not have the power to take or test evidence on oath, or to require third parties to give evidence. When we assess complaints, we consider:  available documents  the recollections of the parties  all relevant circumstances. We give more weight to documents created at the time the events occurred. If there are no relevant documents, we will decide what most likely occurred based on the available information. If there are conflicting recollections and these are evenly weighted, we may find that a claim cannot be established. Report summary Record Key points Complainants’ expert (N) Engineering report 15 May 2020  t he slab in the store - room area behind the saltwater tanks is broken out and shows heavily corroded steel reinforcement and a hole where the slab spalled away during the break - out  t he area of spalling is immediately adjacent to a metal framed structure that contains several saltwat er tan ks  t he timber flooring and metal frame along the floor is damaged from the leaking tanks above  suspended reinforced concrete slabs are constructed with concrete encapsulating steel bars  the size of the compound known as rust is approximat ely six (6) times larger than steel; this means that when corrosion of steel occurs, it imparts an expansive pressure on the concrete  when this pressure exceeds the concrete’s resistance to the Determination | Case number: 768750 Page 8 of 11 pressure; lifting (drumminess), cracking and spalling may occur  in this instance , the presence of saltwater from the leaking of the tanks has exposed the slab to chloride in the form of salt in the water; the corrosion of the steel and spalling is a direct result of this exposure. Insurer’s expert (F) Engineering report 19 August 20 20  it is suspected the cause of the damage to the concrete slab is due to a leaking saltwater tank in the Chinese Restaurant on the first floor of the subject building, however it is unknown when the leak occurred and how long it has been occurring  the lea k is estimated to have occurred sometime between 2008 (when the building and the restaurant were refurbished), and early 2020 (when the spalling was first discovered)  at the time of the ins pection, however, the damaged section of the concrete floor had bee n already reinstated with new concrete and steel reinforcement bars  the observed corrosion to the reinforcing steel in the first - floor slab is located beneath the saltwater tanks of the restaurant  the observed damage to the concrete slab is in the form of delamination and spalling  it is highly unusual for a concrete slab within an enclosed building to exhibit spalling, as expected design period of carbonation induced deterioration of the concrete under normal condition is 40 - 60 years  in this case, however, the spalling was located adjacent to tanks holding saltwater, which cont ains chloride ions  chloride ions from the leaking saltwater have penetrated the concrete surface of the first - floor slab in sufficient concentration to initiate and propagate corrosion to the reinforcing steel  the process of the reinforcing steel corrosion has led to the expansion of the steel causing the cracking, delamination and spalling of the concrete slab surrounding the corroding steel bars  d eterministic chloride diffusion modell ing for a general purpose (GP) cement based 25MPa concret e with 2Smm cover and reinforcing steel indicates that expected corrosion initiation of the top reinforcement would occur within 5 years  g iven the information that the saltwater tanks were installed in 2008, it is estimated that the steel corrosion would have begun around 2013  c racks, delamination and spalling of the concrete induced by the corrosion and subsequent expansion of the steel reinforcing bars are expected to occur within 2 - 4 years of corro sion initiation  a s such the observed damage to the concrete slab to the subject building is expected to have begun to occur in around 2015 – 2017  in conclusion, based on the site observations and review of the supplied information, the observed damage to t he concrete slab of the subject building is directly caused by the corrosion initiation of the top reinforcement resulting from the leaking saltwater tanks Determination | Case number: 768750 Page 9 of 11  the steel corrosion would have begun around 2013 and caused the observed damage to the concrete slab starting in around 2015 - 2017. Insurer’s expert (V) Engineering report 10 Aug 2020  t he photographs supplied by others show corrosion to the reinforcing steel In the first - floor slab section beneath the saltwater tanks of the restaurant  t he visible damage to the first - floor slab section at the Property was understood to be of the form of delamination and spalling  i t is highly unusual that concrete within an enclosed building will exhibit spalling; design standards, such as AS3600, provide appropriate cover to accommodate expected carbonation - induced deterioration for a design period of 40•60 years  h owever. in this case the spalling was located adjacent to tanks holding saltwater  s altwater contains chloride ions, which. as discussed above. can result i n corrosion of embedded reinforcing steel  c hloride ions from the saltwater of the restaurant tanks have penetrated (predominantly by diffusion) the concrete of the first - floor slab section in sufficient concentration to Initiate (and propagate) corrosion t o the reinforcing steel  during the lifetime of a reinforced conc rete structure two basic periods with respect to corrosion and corrosion protection of reinforcement can be defined - the initiation period (to). when critical or threshold amounts of chloride s have not reached the reinforcement and/or when carbonation has not progressed to reinforcement depth so that the reinforcement remains passive. and the propagation period (t,) when reinforcement corrosion proceeds  the time to chloride induced reinforceme nt corrosion initiation can be estimated using deterministic chloride diffusion modelling; it is then understood that the following assumptions apply to the first - floor slab and Its exposure to saltwat er from the restaurant tanks namely  the saltwater tanks were installed in the Brook vale Chinese Restaurant In 2008  Fe 25MPa concrete grade  general purpose (GP) cement based concrete  design cover to top (12mm 0) reinforcing steel= 25mm  deterministic chloride diffusion modelling, for a GP cement based 25MPa conc rete and (top) reinforcing steel cover of 25mm, indicates corrosion initiation of top slab reinforcement would occur within 5 years (i.e. In - 2013 given that the saltwater tanks are understood to have been installed in 2008  many factors affect the corrosi on rate of steel in concrete (e. g. availability of oxygen, anodic process polarisation, pit chemical conditions, resistance between anodic and cathodic sites, potential difference bet ween anodic and cathodic sites, Determination | Case number: 768750 Page 10 of 11 environment conditions, concrete quality, concrete cover, reinforcement type and diamet er, etc) and consequently the time to reinforcement corrosion propagation and the evidence of visible concrete damage  for the assumed GP cement based 25MPa concrete, 12mm diameter reinforcing bars of cover 25 m m, cracking, delamination and spalling of the top reinforcement in the first floor slab beneath the saltwater tanks is likely to have occurred within 2 - 4 years after corrosion initiation (i.e. 2015 - 2017). Complainant’s expert (P) Structural report 24 Sep 2020  we have reviewed your insurance claim decision/ determination and the reports attached and are concerned that the assessment has not been based on site specific data but instead on estimates/averages provided by your original inspecting engineer (who was not engaged in a forensic capacity), and as such, may not accurately represent the actual conditions on site  we must also not e that we generally agree with the method of analysis used to predict or backdate the damage and/or the process to date, howeve r, the lack of site specific dat a used in the modelling of both the initiation and propagation phase means that the results are somewhat erroneous and are potentially misleading  as identified in a number of the reports provided to date, corrosion initiatio n is dependent on a number of factors including the cover to the steel (depth), the surfac e concentration of chlorides and the diffusion rate through the concrete, and if we break this down furt her, surfac e concentration is directly related to the flow rat e and/or chloride content of the water on top of the slab and the diffusion rat e is directly related to the water/cement ratio and density of the concrete mat rix, so as you can see by the number of factors influencing the time to first corrosion, if we don ’t use input dat a that reflects the conditions on site then the out puts will be largely inaccurat e  similarly, the propagation of cracking is influenced by numerous factors including but not limited to:  t he concrete cover  t he concrete strength (t ensile resi stance to cracking)  the steel reinforcement size, material composition and layout (including any additional shrinkage mesh)  the oxygen available to react with  the electrical resistivity of the concrete material (and availability of electrons etc.)  the humidity  the pH level of the concrete, and Determination | Case number: 768750 Page 11 of 11  t he temperature over time  we understand that it is quite difficult to measure and/ or retros pectively assess things like the leakage rate of the tanks, salt content of tank water, temperature, oxygen/humidity level s etc. and that these items would need to be assumed based upon historic data etc., however, a lot of the site specific geometric and material properties of the slab could have been, and could still be, determined using any number of non - invasive investiga tion techniques and would have reduced the potential margin of error in the modelling  for example, the concret e strength and composition of the surrounding slabs could have been assessed/tested to determine the density of the material and to verify the or iginal assumption of 25MPa, and the cover, spacing and arrangement of steel reinforcement could also have been determined using a number of conc rete scanning tools that are readily available for hire  further to the above, and to cast further doubt on the a ccuracy of the model, we not e that there was additional reinforcement (mesh) in the slab observed by Mr DH at the time of the repairs  this does not feature in the assumptions outlined in the report prepared by V and/or has been overlooked, however, it is e ntirely possible that the additional steel reinforcement (depending on the depth/location) may have contribut ed to a shorter corrosion initiation phase and/or could have accelerat ed the corrosion of the underlying bars by providing larger connectivity to t he surrounding slab zones (completing the electrochemical circuit)  once again, there are a number of factors that influence the time from initiation of the corrosion to cracking or spalling, and as such, the wrong input data can sometimes have significant impacts on the final res ults/conclusions. This is also further reinforced by the upper/l ower bound results used by V in their report for their assessment of time until spalling (2 - 4 years)  in summary, and in light of the above concerns regarding th e data u sed/relied upon by V & FMG, we are of the opinion that there is insufficient site - specific dat a and far too many unknown variables involved to support the current corrosion modelling results (and subsequent predicted timelines) in their current format.

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.