Claim denied for damage to basement retaining wall

FirmSuncorp Group
Decided2021-04-01
ProductGeneral Insurance · Home building and contents
OutcomeFor the firm
Amount awarded—
Non-financial loss—
Amount claimed—
SourceAFCA PDF

Summary

The complainant's building insurer declined a claim for a damaged basement retaining wall, which he attributed to a disconnected stormwater pipe or heavy rain. AFCA accepted the engineering evidence that the damage stemmed from long-term moisture and construction issues rather than a single insured event, and found the insurer entitled to deny the claim.

The complainant must first establish a valid claim for an insured event, and the evidence did not show the damage resulted from a single storm or the leaking pipe.

Issues

Subjects and remedies

no remedy

Related

All Suncorp Group determinations · Find similar determinations

Text of the determination

Determination Case number 765149 Financial firm AAI Limited Determination | Case number: 765149 Page 2 of 7 Case number: 765149 1 April 2021 1 Determination overview 1.1 Complaint The complainant holds a building and contents insurance policy with the financial firm (insurer). On 1 September 2020, the complainant lodged a claim in relation to a wall in his basement area, when he noticed the wall appeared to be leaning or moving and the area seemed to be damp. The insurer denied the claim. A preliminary view, in favour of the insurer, was provided by the case analyst in this matter. The complainant rejects this view and the matter has been referred for determination. 1.2 Issues and key findings Is the insurer entitled to deny the claim? On the information provided to me, I am satisfied:  the broken and disconnected storm pipe did not cause the damage to the wall  the complainant has not provided any information that establishes that a valid claim has occurred under the policy  the proximate cause has not been established as an insurable event. The insurer is entitled to deny the claim. 1.3 Determination This determination is in favour of the insurer. The insurer is not required to undertake any further action. Determination | Case number: 765149 Page 3 of 7 2 Reasons for determination I have decided this case on what is fair in all circumstances, having regard to the relevant legal principles, good industry practice, industry codes of practice and previous relevant decisions of AFCA and predecessor schemes. I have considered all the material submitted by the parties both before and after the preliminary assessment. I am satisfied the documentation I have relied on has been provided to both parties. 2.1 Is the insurer entitled to deny the claim? Onus on complainant The onus is on the complainant to establish, on the balance of probabilities, that they have suffered a loss caused by an event to which the policy responds. This is known as a prima facie or valid claim. If the complainant is able to establish a valid claim, the onus shifts to the insurer to prove, on the balance of probabilities, that an exclusion applies if it is to seek to deny or limit its liability for the loss. The insurer must establish that all or some of the claimed loss was caused by an exclusion. Insurer denies that the complainant has established a valid claim The complainant says that they noticed that the wall was damp and leaning. The wall is in a lower section of the property. The complainant also says that the period when they noticed the damage, February 2020, the rainfall recorded was the highest ever and that this is the likely cause of damage to the wall. The insurer says that the complainant has not established a valid claim. Expert Witnesses The insurer appointed an engineer (GC). GC in a report dated 21 September 2020 found the following:  the damage is as a result of long term exposure to moisture  the wall’s design is unsuitable for the amount of soil it retains  there is no damp proof course installed  there was no evidence of vertical subsoil drainage layer between the damaged wall and the soil it retains  there is evidence of prior repairs to the mortar bedding of the brick piers and the wall in the area of damage  February 2020 had the highest monthly rainfall for the area In DW’s report of 21 September 2020, he came to the following conclusion: Determination | Case number: 765149 Page 4 of 7 RC carried out a leak detection test on 7 September 2020 and reported as follows: The client advised in recent months after heavy rainfall they observed the brick wall within the subfloor area to begin to move. The client advised after heavy rainfall the structural movement gradually increases. Upon attendance we observed the pathway to the entrance of the house to of dropped to one side (see attached pic). The path way is on the opposite side of the effected wall. All nitrogen pressure tests to hot water lines passed with no evidence of burst or leaking pipe work. We were unable to pressure test the cold water lines as the water meter tap would not fully turn off. Although we were unable to test we made observations of the water meter for 20 minutes observing the meter not to move. We do not believe there is a leaking cold water pipe throughout the property. We carried out an inspection to the storm water line from the do wn pipe at the front of the premises. Upon inspection we observed the line to be completely disconnected (see attached pic). The disconnected pipe is directly below the driveway. The location of the disconnected pipe work is around 1M below ground surface. We were unable to carry out a make safe due to the extent of work that would have to be carried out to get to the pipe e.g concrete cutting. In closing, the disconnected down pipe would be causing some subsidence but the affected area is some distance away. We believe that the structural movement is not related to a plumbing issue. Determination | Case number: 765149 Page 5 of 7 DW carried out a further inspection on 1 December 2020. He referred to the leak detection test and concluded: … it is considered that the inwards displacement or the RW [retaining wall] is related primarily to the RW construction being unsuitable for the level of retaining observed with hydrostatic pressures associated with surface and subsurface water flows through the land areas to the north of the RW contributing to displacement of the RW over time. It is considered unlikely that surface water discharged from the detached downpipe would have contributed any significant way to the observed RW displacement noting the absence of any differential settlement related cracking to the driveway slab areas locally around the downpipe and also the general slope of the driveway areas around the downpipes location which would tend to initially direct surface water flows to the NE and away from the RW. . Complainant disputes findings The complainant says that the damage to the wall is as a result of a disconnected water runoff pipe and should be covered under the claim as it was caused by storm. He has not provided any experts who have disagreed with those provide by the insurer. He does state that February 2020 was a very wet month and that he noticed the problems after the high rainfall Product Disclosure Statement (PDS) The PDS covers the property for storm, subject to exclusions, but provides in respect of escape of liquids: ...We do not cover wear and tear, or loss or damage caused by the escape of liquid occurring as a result of a gradual process of bursting, leaking, splashing, dripping or overflowing over a period of time when you could reasonably be expected to be aware of this condition. The PDS further qualifies the escape of liquids as follows: Determination | Case number: 765149 Page 6 of 7 Determination | Case number: 765149 Page 7 of 7 The PDS also defines insured event as follows: means the insured events on pages 16 to 25. In addition, an insured event is always a single event, accident or occurrence which you did not intend or expect to happen. In response to this, the insurer says that the damage has not occurred by a single insurable event and otherwise is excluded under the policy. Insurer not liable for claim The complainant has provided information setting out his reasoning for the claim. He has raised the issue of the leaking stormwater pipe and also information about heavy rain. The information provided in the report of DW is compelling. On this information, I am not satisfied that the condition of the wa ll is related to either a single event, storm or the leaking stormwater pipe. DW has provided strong information to show that the damage to the wall is related to other circumstances and certainly, there is no information that has been provided that shows that it is either the result of the leaking pipe or of the weather, including storm. The insurer has contended that the damage has not occurred as the result of a single event. I am satisfied that this is correct. The proximate cause of the damage is rela ted to several issues as set out in DW’s report, but none are in respect of a single storm or the leaking pipe. The complainant has not provided satisfactory information as to why DS’s report should not be accepted. Whilst I am sympathetic to the complaina nt’s claim, the complainant needs to establish that an insured event has occurred before it requires the insurer to show that the claim should be denied for other reasons. On the information provided, I am not satisfied that the complainant has been able to show that there is any damage that has occurred as the result of an event that is insured under the policy. Instead, the damage to the wall appears to be several causes, but none of which are covered under the policy. The insurer is entitled to deny the claim.

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.