Claim denial for water damage from escape of liquid; insurer accepted partially but disputed extent of covered damage
Text of the determination
Determination
Case number 756984
Financial firm Commonwealth Insurance Limited
Determination | Case number: 756984 Page 2 of 11
Case number: 756984 3 June 2022
1 Determination overview
1.1 Complaint
The complainant holds home building insurance with the financial firm (the insurer), covering
his investment property. On 31 July 2018, the complainant lodged a lodged a claim on the
policy, as the insured property had sustained water damage.
The insurer initially declined the claim, on the basis the damage was due to a pipe that had
leaked over an extended period. However, it later accepted that the complainant would not
reasonably have been aware of the leak because the property was tenanted. The parties
agreed that a 12 month drying period was required before further assessment could be done.
After the property was reassessed in October 2019, the insurer offered to cover the cost of
cosmetic internal repairs only. The insurer declined to cover most of the damage, saying it
was caused by long term seasonal moisture changes in the soil, which the policy excludes.
The complainant says all of the damage was due to the claimed escape of liquid event. He
wants the insurer to pay him the building sum insured, loss of rent (LOR), consequential loss,
non-financial loss compensation for stress and inconvenience it has caused and to reimburse
him for professional costs incurred during the claim process.
1.2 Issues and key findings
Is the insurer required to cover more of the claim?
Yes. The available information shows that the proximate cause of the damage claimed was
the escape of liquid event. The extent of the covered damage is set out in the report dated 6
June 2021 from the complainant’s engineer, NE.
Are further investigations required?
Yes. The repair works required, and their cost, have not been adequately assessed. The
insurer is to appoint a new independent engineer to prepare a scope of works (SOW) based
on NE’s description of the covered damage. The insurer is then to get two new independent
builders’ quotes based on the SOW and cash settle the claim on the higher of the two quotes
plus a 15% uplift. LOR may also be payable after the SOW is received.
Is the complainant entitled to any additional payments?
Yes . The insurer’s claim handling caused the complainant undue stress and inconvenience. It
is to pay him $2,500 in non-financial loss compensation. Further, the complainant’s engineer,
NE, particularly assisted in establishing the extent of the covered claim. The insurer is to
contribute $10,000 to the costs NE and UL charged the complainant. However, the
complainant is not entitled to be compensated for his time or for other consequential loss.
Why is the outcome fair?
The outcome is fair because the available information shows the proximate cause of damage
was escape of liquid. Accordingly, it is fair that the insurer pays the claim subject to the
Determination | Case number: 756984 Page 3 of 11
applicable policy limits, once the required repairs and their cost have been adequately
assessed. It is also fair that the insurer pays non-financial loss compensation and contribute
to the complainant’s professional costs given how the claim has been managed.
1.3 Determination
This determination is in favour of the complainant.
Following receipt of notice that the complainant accepts this determination (notice), the
insurer is to:
Within 14 days of receiving the notice, appoint an independent engineer who has not
previously been involved in the claim, to promptly prepare a SOW based on NE’s
description in its report dated 6 June 2021 of the covered damage. The SOW is to include
an estimate of the period during which the tenants will not be able to live in the property
(time estimate)
Within 14 days of receiving the SOW, the insurer is to pay the complainant LOR at the rate
of $400 per week for the time estimate
Within seven days of receipt of the SOW, request two independent builders not previously
involved in the claim, to provide current and actionable quotes based on the SOW
the insurer is to pay the complainant the higher of the two quotes plus a 15% uplift for
repair contingencies and transfer of risk. The maximum amount payable for this aspect of
the matter is $322,500 in light of the gap cover included in the policy
within 21 days of receiving the notice, pay the complainant $2,500 in non-financial loss
compensation and a contribution of $10,000 towards the professional costs the
complainant paid for the reports or NE and UL.
Determination | Case number: 756984 Page 4 of 11
2 Reasons for determination
Both parties have provided numerous expert reports and very detailed submissions. While not
all of that material is specifically referred to below, the panel has read and taken into account
all of the available information when making its determination.
2.1 Is the insurer required to cover more of the claim?
Yes. The available information shows that the proximate cause of the damage claimed was
the escape of liquid event. The extent of the covered damage is set out in the report dated 6
June 2021 from the complainant’s engineer, NE.
Complainant has established a valid claim under the policy
The complainant is required to show on the balance of probabilities (that it is more likely than
not) that he suffered a loss caused by an insured event covered by the policy. This is known
as a valid claim.
The complainant holds a home building policy. Relevant extracts of the policy’s product
disclosure statement (PDS) are set out in section 3.2 of this determination. Subject to its
conditions and exclusions, the policy provides cover for loss or damage caused by the
insured events listed in the PDS, which includes ‘Escape of Liquid’ (EOL).
The available information shows that a burst cold water pipe under the subfloor resulted in
damage to the property. On 24 September 2018, the insurer wrote to the complainant stating
that its appointed building consultant (GC) and structural engineer (IL) had confirmed that the
cause of the property damage was prolonged EOL from a leaking pipe. The insurer said the
claim was excluded as the EOL had occurred over a long period and the complainant had not
promptly notified it of the problem.
The insurer subsequently realised that the complainant would not have been reasonably
aware of the ongoing EOL as the property was tenanted. After further investigation, o n 19
December 2019, the insurer wrote to the complainant confirming it accepted the claim.
In the circumstances, the panel is satisfied that the complainant has established a valid claim.
Once the complainant establishes a valid claim, the insurer is liable for the loss unless it
shows an exclusion or limiting condition applies. The insurer has the onus of proof in
establishing that an exclusion applies. The standard of proof is the balance of probabilities .
Insurer says only limited amount of damage is covered
In its initial report dated 4 September 2018, IL concluded that the EOL event had contributed
to 90% of the property damage, with 10% due to a lack of adequate subfloor cross ventilation.
IL said the recorded floor levels confirmed that the founding soils, particularly in the W/C,
laundry and lounge area, had become saturated and heaved as a result of the EOL. IL
recommended a 12 month drying out period before assessing what repairs were required.
IL reattended the property in October 2019. IL confirmed that the soils had sufficiently
stabilised to enable rectification works to commence. IL also said that the overall variation in
floor levels throughout the dwelling of 50mm in August 2018 had alleviated to 36mm meaning
no structural works to the foundations of the dwelling would be required.
Determination | Case number: 756984 Page 5 of 11
The insurer obtained from GC a scope of works dated 10 October 2019, which costed
covered repairs at $9,990.75.
As the complainant was dissatisfied with GC’s scope of works and said further damage had
occurred, IL reattended the property in December 2019. In its report dated 12 December
2019, IL said the additional damage the complainant had identified was not attributable to the
EOL event. Rather it was pre-existing and/or was due to natural settlement and deterioration
of inadequately compacted fill.
As a result, on 19 December 2019, the insurer wrote to the complainant saying it accepted
the claim for:
Damage to the bathroom, entry hallway, bedroom 1, bedroom 2, bedroom 3, dining lounge,
laundry and kitchen
but said the:
tiled porch slab and other cracking, other than what has been accepted above is not
consistent with being caused by the one-off escape of liquid.
Insurer appoints second engineer, maintains claim only partially covered
The complainant continued to dispute the in surer’s decision. This led to the insurer appointing
a forensic engineer (FM), whose findings were in line with those of IL.
FM has provided five reports during the course of the dispute. In summary, FM says:
the cracks to the veranda tiles existed before 2014
the bathroom movement (gap between vertical edge of vanity and bathroom wall) shows
the floor was not level prior to the 2018 EOL. As the bathroom is remote from the leak and
there is no heave, the damage to it is not related to the 2018 event
the same rationale applies to the damage to the threshold between the kitchen and living
room
the damage to the house has been caused by ongoing long-term variations in the moisture
content of the reactive foundation soils due to seasonal moisture changes
the footings do not meet AS2870 for minimum depth, have contributed to the damage and
replacement of them would be a betterment
soil moisture levels are still high (three years after the pipe was repaired)
an unidentified water source has contributed to the building movement and resultant
damage (not related to the 2018 EOL event)
many of the rooms in the GC scope of works are remote from the leak, indicating long term
ground movement.
In light of the reports of IL and FM, the insurer has maintained its position that its liability
under the policy is limited to attending to the repairs outlined in GC’s statement of works.
Nevertheless, on 10 September 2019, it offered to resolve the complaint for $19,490.75. The
offer comprised of GC’s costing of $9,990.75 less the $500 policy excess, plus $10,000 as a
commercial gesture of goodwill.
Compl ainant’s experts say EOL caused structural damage
The complainant engaged three experts - structural engineer (N) and structural/geotechnical
engineers (SM and UL). SM provided one report and NE and UL two each. These experts
disagreed with the findings of the insurer’s experts .
Determination | Case number: 756984 Page 6 of 11
SM’s report dated 6 February 2019 says:
the site’s soil is P (Problem Site), highly reactive and is drainage poor
damage to the structure has been caused by a combination of the water leak and previous
moisture influences from trees on the eastern boundary
SM cannot apportion damage without further information, but subfloor ventilation is not a
contributing factor
SM recommends a 12 month drying period.
In its reports dated 23 November 2020 and 25 October 2020, UL says:
The foundation soil is highly water-reactive and capable of swelling and lifting the house
stumps and other footings causing gaps and cracks in internal and external walls and floor
and roof distortions (as have been observed)
There are higher moisture levels outside the front veranda at a depth of 0.5 to 1.0 metre.
W ater from the ‘spraying’ water pipe has spread a signi ficant distance, wetting a significant
area laterally by water flow and clay suction and vertically through soil cracks
it’s ‘c ommission did not include any need for an argument about the testing of all
possibilities since ‘ipso facto’ we knew the source of the water and the owner and tenants
assured [UL] there had been no house damage or movement prior to the leak ’
UL believes the complainant had also been told by tenants, who have rented the property
since 2002, they did not previously notice internal movements like those recently observed
The moisture levels are so high, the drying process will take at least another two to three
years, and movement will continue in the meantime. UL recommends steps be taken to
accelerate the drying process.
In its main report dated 6 June 2021, NE says:
the roof and masonry walls are out of alignment, exceeding tolerance levels
cracking in walls and gaps between pavement and masonry have most likely occurred due
to rotation of footings due to horizontal sub-floor soil expansion
the amount of water exposed to the subfloor area has shortened the life of timber flooring,
bearers and joists, structural durability has also been affected
the most extensive cracking is found in the vicinity of the laundry
concrete stumps may have become misaligned or risen and subsided due to different
stages of flooding, causing floor to become uneven
floor level variations exceed maximum tolerance
extensive repairs or demolishment are required.
Complainant’s expert evidence is more persuasive
It is not in dispute a water leak totalling 600,000 litres occurred over the course of 73 days
underneath the complainant’s house. This is a significant amount of water. Both parties have
provided a number of reports from appropriately qualified experts on the extent of damage as
a result.
The insurer has sought to mitigate its exposure by maintaining the cause of most of the loss
was not the EOL event, but rather was due to long term seasonal ground movement,
inadequate footings and an as yet unidentified water source.
However, the panel considers that the insurer’s c riticism that the complainant’s experts have
failed to sufficiently substantiate their respective positions, can also be levelled at the
insurer ’s experts . For example, the suggestion that an unidentified water source has
contributed to the damage is speculative.
Determination | Case number: 756984 Page 7 of 11
Further, the insurer has not responded to NE’s comment that AS2870 did not exist when the
house was built so is irrelevant. Nor has it acknowledged written statements from the tenants
and previous owners of the house that support the complainant’s position .
Overall, the panel is persuaded that the complain ant’s expert evidence establishes that the
EOL event was the proximate or dominant cause of the damage NE outlined in its report
dated 6 June 2021. In particular, the reports of NE and UL provide a logical and
comprehensive explanation of what has occurred, which is consistent with the statements of
the tenants and the former owner. Further, the insurer has not provided a report from an
expert with the geotechnical expertise held by UL.
Therefore, the insurer is required to cover the cost of repairing the damage NE has outlined.
2.2 Are further investigations required?
Yes. The repair works required, and their cost, have not been adequately assessed. The
insurer is to appoint a new independent engineer to prepare a statement of works (SOW)
based on NE’s description of the covered damage. The insu rer is then to get two new
independent builders’ quotes based on the SOW and cash settle the claim on the higher of
the two quotes plus a 15% uplift. LOR may also be payable after the SOW is received.
Further assessment of necessary repairs and their cost is required
As noted above, the insurer obtained an SOW and costing from GC, totalling $9,990.75.
However, the SOW and costing is based on the insurer’s conclusion that its liability under the
policy is only for the internal damage. The panel has found the insurer’s liability is much more
extensive.
The complainant has provided a 127 page report dated 10 August 2021, from MQ, quantity
surveyors. MQ has set out two rectification options with detailed breakdowns of the costs
involved:
Option one (rebuild): $731,500
Option two (repair): $1,007,963.
The panel notes that, overall, the expert evidence supports repairing rather than demolishing
and rebuilding the insured property.
However, the panel is not satisfied that MQ’s costing of either option should be rel ied upon
because:
the insurer is yet to have the opportunity to obtain an SOW and costing based on the
finding it is liable for the damage NE says is due to the EOL event
MQ’s costing was provided nearly 12 months ago and pricing will have changed since it
was provided
the further drying period UL suggested was needed has substantially expired
the maximum amount payable for the building under the policy is $322,500 (sum insured of
$258,000 as at the date of loss plus the gap cover of up to a further 25% of that amount if
the sum insured is exceeded). It is fair that a current costing is obtained before the insurer
is obliged to make a total loss payment.
Accordingly, while mindful that the EOL event occurred four years ago, the panel is satisfied
that fairness dictates that further assessment is required, as follows:
the insurer is to appoint an independent engineer who has not previously been involved in
the claim, to promptly prepare a SOW based on NE’s descript ion in its report dated 6 June
Determination | Case number: 756984 Page 8 of 11
2021 of the covered damage. The SOW is to include an estimate of the period during
which the tenants will not be able to live in the property
within seven days of receipt of the SOW, the insurer is to request from two independent
builders not previously involved in the claim, current and actionable quotes based on the
SOW
the insurer is to pay the complainant the higher of the two quotes plus a 15% cash
settlement uplift for repair contingencies and transfer of risk. The maximum amount
payable for this aspect of the matter is $322,500 given the gap cover included in the policy.
LOR may also be payable
The policy includes as an additional benefit, cover for LOR. The cover is available where the
damage at the insured address is so extensive that it can no longer be lived in by the tenants.
The amount payable is the average weekly rent paid over the 52 weeks preceding the claim
event. LOR will be paid for a maximum period of 52 weeks while the property is repaired,
rebuilt or otherwise becomes liveable.
The LOR benefit is in addition to the sum insured for the building.
To date, there is no LOR entitlement given the complainant has confirmed the tenants have at
no stage moved out since the EOL event. He says he has had to leave rent frozen at $400
per week and seeks to be paid the 3% annual increase he says he would have applied had
the claim event not occurred.
However, such a loss does not fall within the terms of the LOR additional benefit set out in the
policy. Further, the loss of opportunity to increase rent is a consequential loss. The policy
specifically excludes consequential losses and loss of profit.
Nevertheless, the panel is satisfied that the LOR benefit will apply to the extent the tenants
have to move out during the period required for repairs to be completed. The average weekly
rent for the 52 weeks preceding the EOL was $400.
The SOW the insurer is to obtain is to include an estimate of the period (if any) during which
the tenants will not be able to live in the property. Within 14 days of receiving the SOW, the
insurer is to pay the complainant LOR at the rate of $400 per week for the time estimate.
2.3 Is the complainant entitled to any additional payments?
Yes. The insurer’s claim handling caused the complainant undue stress and inconvenience. It
is to pay him $2,500 in non-financial loss compensation. Further, the complainant’s engineer,
NE, particularly assisted in establishing the extent of the covered claim. The insurer is to
contribute $10,000 to the costs NE and UL charged the complainant. However, the
complainant is not entitled to be compensated for his time or for other consequential loss.
AFCA may award non-financial loss compensation in certain circumstances
Under paragraph D.3 of the AFCA Rules, we may award compensation for non-financial loss
(capped at $5,400) where the insurer ’s actions have caused an unusual amount of:
physical inconvenience
time taken to resolve the situation
interference with the complainant’s expectation of enjoyment or peace of mind.
Determination | Case number: 756984 Page 9 of 11
Insurer has caused stress and inconvenience
The complainant says that the claim process has amounted to an exhausting trial. He says
the property being in a water damaged state for years while the insurer has unreasonably
refused to fully the cover the loss has been highly stressful and inconvenient. He feels that
the insurer has not assessed the claim in a professional or fair manner.
This claim has taken an extended period of time. Some of the delay, such as the need for
drying periods and difficulties caused by COVID-19, was unavoidable. However, the panel is
satisfied the insurer has contributed to the delay and overall should have better managed the
claim. The insurer initially unreasonably denied the claim. Further, it appears the insurer
became entrenched in its coverage position rather than considering the merits all of the
complaint’s submissions.
The insurer has caused the complainant unnecessary stress and inconvenience. It is to pay
him $2,500 in non-financial loss compensation.
Insurer is to contribute to the complainant’s costs
The AFCA rules enable AFCA to require an insurer to contribute to the professional costs
incurred by the complainant. These costs are, however, usually capped at a total of $5,000
per complaint, regardless of the number of claims or issues raised in it or the types of costs
incurred. If special circumstances apply, AFCA may require an insurer to contribute more
than the usual $5,000.
When considering whether to require a financial firm to make a costs contribution, AFCA
takes into account the complexity of the complaint and whether the particular complainant
needed to incur costs to understand or establish their claim. An example of possible special
circumstances is where the complaint is complex and involves a very large amount of money
for the complainant.
The complainant has incurred costs for expert reports totalling $16,923.50. Of the reports, the
panel has particularly found those of NE and UL useful in establishing the extent of the
covered claim. The complainant has been charged a total of $6,710 by NE and $4,136 by UL.
Given the complexity of the issues involved, the potential quantum of the complainant’s
losses and the amount he has incurred in professional fees, the panel is satisfied that special
circumstances apply. The panel is satisfied that it is fair that the insurer pays the complainant
$10,000 as a contribution to the fees NE and UL charged him.
The complainant seeks a further $50,000 for his own ‘time negotiating claim/rebutting denial
of liability ’ . However, as previously noted, the policy excludes cover for consequential loss
claims.
2.4 Why is the outcome fair?
The outcome is fair because the available information shows the proximate cause of damage
was escape of liquid. Accordingly, it is fair that the insurer pays the claim subject to the
applicable policy limits, once the required repairs and their cost have been adequately
assessed. It is also fair that the insurer pays non-financial loss compensation and contribute
to the complainant’s professional costs given how the claim has been managed.
Determination | Case number: 756984 Page 10 of 11
3 Supporting information
3.1 The AFCA process
AFCA’s approach is based on fairness
AFCA has determined this complaint based on what is fair in all the circumstances, having
regard to:
the legal principles
applicable industry codes or guidance
good industry practice
previous decisions of AFCA or its predecessor schemes (which are not binding).
The respective parties have completed a full exchange of the relevant information, and each
party has had the opportunity to address any issues raised. We have reviewed and
considered all of the information the parties have provided.
While the parties have raised a number of issues in their submissions, we have restricted this
determination to the issues that are relevant to the outcome.
A panel determined this matter
Due to the nature of this complaint, we referred it to a panel for determination. The panel
includes:
an ombudsman
a member with significant experience in consumer and small business advocacy
a member with extensive experience in the insurance industry.
We assess complaints on available information and circumstances
AFCA is not a court of law. We do not have the power to take or test evidence on oath, or to
require third parties to give evidence.
When we assess complaints, we consider:
available documents
the recollections of the parties
all relevant circumstances.
We give more weight to documents created at the time the events occurred. If there are no
relevant documents, we will decide what most likely occurred based on the available
information.
If there are conflicting recollections and these are evenly weighted, we may find that a claim
cannot be established.
Determination | Case number: 756984 Page 11 of 11
3.2 PDS extracts
PDS page 41
Escape of Liquid
What is covered
Your building and/or contents are covered for loss or damage caused by the sudden and
unexpected escape of liquid from any:
Fixed wat er pipe
What is not covered
Your building and/or contents are not covered under this Insu red Event for:
loss or damage caus ed by any escape of liquid of which you were aware and
failed to notify us of within a reasonable period;
loss or damage caus ed by any gradual escape of liquid;
PDS pages 75 and 77
General Exclusions
Under this policy there is no cover provided for any loss, damage or liability caused
directly or indirectly by or in any way connected with:
8. Subside nc e or landslide…;
9. The vibration, settling, shrinking or expanding of earth or any building, foundation, wall,
pavement or path … ;
We will also not cover:
35. Gradual loss or damage of any kind;
36. consequential losses or loss of profit;
Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.