Home / Suncorp Group / Determination 754458

Determination 754458

Claim declined under ground movement exclusion

FirmSuncorp Group
Decided2021-06-17
ProductGeneral Insurance · Home building and contents
OutcomeFor the firm
Amount awarded—
Non-financial loss—
Amount claimed$77,000
SourceAFCA PDF

Summary

The complainants claimed for storm and septic leak damage to their home and sought rebuild costs and $77,000 in consequential losses. AFCA agreed with the insurer that long-term ground movement was excluded and ordered no payment.

The proximate cause of damage was ground movement over time, which the policy excludes, rather than the single storm or the escape of liquid.

Issues

Subjects and remedies

home or building damagenatural disasterno remedy

Related

All Suncorp Group determinations · Find similar determinations

Text of the determination

Determination Case number 754458 Financial firm AAI Limited Determination | Case number: 754458 Page 2 of 13 Case number: 754458 17 June 2021 1 Determination overview 1.1 Complaint The complainants hold a home insurance policy with the financial firm (insurer). On 23 March 2020, a claim was lodged for damage to the home following a storm in February 2020. The complainants say the damage caused by storms followed a lengthy dry period. This in turn caused leaks in the greywater drainage and septic tank which contributed to the damage and the development of mould. The insurer declined the claim. It says the damage was caused by differential ground movement over time which is excluded from cover under the terms of the policy. The complainants seek payment for the cost of demolishing and rebuilding the property, as well as compensation for financial and non-financial loss. 1.2 Issues and key findings Is the insurer entitled to rely on its policy exclusions to decline the claim? Yes. The panel accepts, given the available information, that most likely the damage to the property arose because of ground movement occurring over time. Such damage is excluded from cover under the terms of the policy. Are the complainants entitled to compensation for non-financial or consequential loss? No. The panel acknowledges the stress and pressure that the claim has placed on the complainants. However, the insurer has acted fairly and reasonably in assessing and reviewing the claim. The claims handling has not caused any unusual delay nor is there evidence that the insurer had acted unreasonably. 1.3 Determination This determination is in favour of the insurer. The insurer is entitled to rely on the terms and conditions of the policy to refuse payment of the claim. Determination | Case number: 754458 Page 3 of 13 2 Reasons for determination 2.1 Is the insurer entitled to rely on its policy exclusions to decline the claim? Policy provides cover under specific circumstances The complainants ’ policy is an insured events policy covering a series of listed events including storm and the escape of liquid. A storm is defined to include violent wind, cyclone, tornado, rain, thunderstorm, hail, snow and landslide or subsidence that happens immediately as a result of a storm. ‘Escape of liquid’ includes loss or damage caused by liquid leaking, overflowing or bursting from any drain, fixed pipes, fixed tanks, drainage and sewage systems. Circumstances of claim On 23 March 2020, the complainants lodged a claim saying ‘ I was digging to prep a deck around the house. I have dug down to the footings as I wanted to bolt to the slab, and upon reaching the footings I noticed large cracks in it ’ . The complainants say this change in weather patterns with heavy rain in mid- February to March 2020 caused the septic tank at the property to crack allowing liquids to escape from the tank and under the footings of the house, causing the house to move. The complainants believe movement of the footings has caused displacement of the roof system which is allowing water ingress into the property, causing widespread mould throughout. Bureau of Meteorology records at Lyons close to the complainants’ property indicate 69mm of rainfall was recorded on 11 February 2020 (the highest daily rainfall), and February 2020 had a monthly rainfall of 218mm. There is no dispute there was heavy rainfall during February 2020 or that there was a leaking sewer line. However, the insurer says the proximate cause of damage to the complainants’ property was not the storm event or escape of liquid, but long-term differential ground movement. Such damage is excluded under the terms of the policy. Expert reports differ as to cause of the damage The insurer has relied on reports from engineer (KM) and building consultant (AB), a geotechnical engineering firm (S) and hygienist (CFE) to support its position. The complainants have relied on reports from an engineer (BES) and building inspection from (X). The reports are summarised i n section 3 of this determination. The insurer says the reports while confirming the presence of leaks in the sewer line from the original septic tank and in the grey water line do not support the complainants ’ claim. Determination | Case number: 754458 Page 4 of 13 KM in its first report identified cracking visible in the footings, a gap visible between the footings and floor slab, cracking in the external wall cladding and cracking to the internal finishes. KM says this could not be attributed to the single reported rain event in February 2020. KM considered leaks detected in the house drainage system is isolated to the south eastern corner of the house. The general damage to the wall finishes and proximity of the leaks from the footing cracks indicate that the damages are not consistent with a single leak event. KM attributed the damages to natural ground movement over the life of the building, normal building movement, nature of the brittle finishes and the construction method. Following receipt of additional information from AB and S , KM concluded:  Damage to the house cannot be attributed to the single storm event.  Damage cannot be attributed to the plumbing leaks detected.  Both conclusions are still valid given the additional information provided by S and recent floor level survey.  The damage to the house would have occurred over its life and is attributed to natural ground movement and the construction method. The insurer appointed mould experts (CFE) considered it unlikely that mould contamination in the residence was caused by water entering the building via the roof above the northwest corner of Bedroom 1 or water flowing from the western side of the residence. A roofing report from AB indicates there was little to no maintenance completed on the roof and ceiling and that mould throughout the dwelling walls and ceiling is environment mould growing on the paint. The worst affected area is the bathroom where there is a low ceiling and poor ventilation, and steam from showers is contributing to the mould. Leaks identified were considered unlikely to cause the mould growth. The complainants ’ report from engineer (BES) on the other hand says:  There were some cracked/broken plumbing pipes at the rear right-hand side corner (where the slab and footings appear to have settled). This leads to an undergro und water/sceptic tank.  The exact condition of the tank is unknown at the time of writing the report.  The structure needs immediate rectification works to enable people to continue living within.  The cause of the damage to the property is most likely due to the extreme weather event resulting in large soil movement which in turn, has resulted in damage occurring to the property.  This initial damage has quite likely caused cracking to the pipes which could be leading to a continuation of the effects/worse ning of the effects from the initial damage that occurred. Determination | Case number: 754458 Page 5 of 13 The building inspection report from (X) identifies damages at the premises but does not provide any opinion on what caused the damages. The report provides a recommendation to have a structural engineer and geotechnical engineer attend the premises. Most likely proximate cause of damage is ground movement The panel is persuaded by the information provided by the insurer that the proximate cause of damage, that is the effective cause of the damage, is ground movement over a period and not the result of a single storm or escape of liquid. BES’s report is not as persuasive as those provi ded by the insurer’s experts . The panel accepts that when lodging the claim, the complainants believed an escape of liquid event had occurred and was the dominant cause of the damage. However, the evidence suggests that although there are cracks to the septic tank and pipes around the property, the leaks had no significant contribution to the damage at the property. Un der the insured event ‘storm’ the policy says the insurer will provide cover loss or damage to the building caused by a landslide or subsidence proved to have occurred within 72 hours of, and directly because of, a storm and not because of erosion over time, structural fault or design fault. There is no evidence of a landslide or subsidence. There is no evidence to confirm the damage to the property occurred within the allotted 72-hour period following the storm event. While the report from X identifies damages to the property it does not provide any opinion on what caused the damages. Information within KM’s reports indicates cracking throughout the property appears to be extensive and pre-dates the claimed storm event. This suggests the property has been subject to ongoing ground movement issues. The panel is satisfied the evidence shows damage to the property was most likely caused by general ground movement due to seasonal changes in the soil around the property. These changes appear to have occurred over time and pre-date the storm event. This is supported by the findings by BSE who reported the soil surrounding the property appeared to be really dry, with surface cracks evident towards the front of the property. There is also localised areas of soil mounds and valleys present in the neighbouring fields, and this indicates that the site is likely to undergo large amounts of seasonal movement. As the policy does not cover loss or damage arising from ground movement, the insurer is entitled to decline the claim. Determination | Case number: 754458 Page 6 of 13 2.2 Are the complainants entitled to compensation for non-financial or consequential loss? Complainants say insurer should pay compensation The complainants say they have been experiencing both financial and personal stress following the decline of the claim, with further damage occurring to their property. The complainants have not been able to return to live in their home and have been living in a caravan (owned by the complainants) in their front yard. The complainants are seeking compensation in the amount of $77,000, for costs associated with lost time from work, running costs, fuel and labour costs that have risen since they have been residing in the caravan. The insurer says it is entitled to rely on its policy exclusions, and as such has not made any offers to the complainants to resolve the complaint. Complainants are not entitled to compensation The panel is sympathetic to the situation the complainants find themselves in. There is however no information to indicate the insurer unreasonably delayed the consideration of the claim or acted inappropriately in handling the claim. The loss as identified has been fairly assessed and the insurer has responded to issues such as mould in a timely manner. The panel accepts the insurer has acted reasonably and determines the insurer is not liable to pay compensation as claimed. Determination | Case number: 754458 Page 7 of 13 3 Supporting information 3.1 Relevant policy sections Section What you are covered for - Insured Events ) Storm We cover  Loss or damage to the building caused by a storm. We do not cover  loss or damage caus ed by erosion, vibration, subsidence, landslip, landslide, mudslide, collapse, shrinkage or any other earth movement, but we will cover loss or damage to the building caused by a landslide or subsidence proved to have occurred within 72 hours of, and directly because of, a storm and not because of erosion over time, structural fault or design fault; […] E scape of liquid We cover Loss or damage to the building caused by liquid leaking, overflowing or bursting from any of the following:  refrigerators, freezers, dishwas hers and washing machines;  any drain, fixed pipes, roof gutters or guttering and rainwate r downpipes, drainage and sewage systems;  fixed tanks;  swimming pools or spas;  waterbeds;  ba ths, sinks, toilets and basins;  fixed heating or cooling system;  water main, fire hydrant or water supply pipe;  an aquarium. What we do not cover - general exclusions You are not covered under any section of your policy for damage, loss, cost or legal liability that is caused by, arises from or involves: […] Ground movement erosion, vibration, subsidence, landslip, landslide, mudslide, collapse, shrinkage or any other earth movement, but we will cover landslide or subsidence that is specifically covered under the following insured events:  ‘Storm’;  ‘Flood’ (but only if you hav e cover for insured event ‘Flood’);  ‘Earthquake and Tsunami’;  ‘ Explosion’ Determination | Case number: 754458 Page 8 of 13 3.2 Expert reports Report Findings Building consultant (AB ) report 29.05. 2020  In my professional opinion I do not believe the cause of the building movement is due to the one single storm event and I do not believe it is attributed to an escape of liquid event either. It is my professional opinion that the damage to the property is resultant from building movement over a time.  There is an old septic tank whic h has a crack on the hous e side of the rear RHS of the septic tank. Although the crack is not wide it is approx 1.5 to 2 meters long and runs vertically.  The septic tanks existing water level and solids level was at the current outlet invert level. If the septic tank had a substa ntial leak the level would be lower than the septic tank outlet invert level. rear of the property and these required to be emptied and inspected to ens ure that they have not attributed to any of the building movement.  At this stage I am unable to quote t he resultant damage as I believe the engineer needs to review the LLR to determine cause and to aid in a policy determination prior to submitting a quote.  If it was found that the septic tank leak has resulted in the building movement damage I believe the estimated repair costs would exceed $100,000 including make safe costs hence this would have to be considered major loss. Building consultant (AB) leak report 02.06. 2020 It is in my professional opinion there are three causes for the water ingression into the RHS rear corner:  The 100mm sewer line that connects to the rear 2,000 original septic tank is cracked and has been allowing black water to soak into the ground over a time.  The 100mm grey water line that has a temporary damaged duct work connectin g the two sections toget her was obviously damaged prior to the section being cut out by the insured.  It is my opinion that this has been leaking for a very long period and has saturated the rear RHS foundations of the dwelling.  I make this opinion as the 100mm drain is connected to the only bathroom in the dwelling and the shower/bath combination would be utilised at least twice to four times per day.  Considering the dwelling has dropped on that rear RHS corner I believe that the grey water waste pipe is t he major cause of the issues.  The only other way to test my theory would be soil testing at three locations at the rear RHS, next to the sewer cracked pipe and the second between the septic and the dwelling and the third down next to the broken grey water line.  After our inspection today, I found the old septic tank has a crack on the house side of the rear RHS septic tank. Although the crack is not wide it is approx 1.5 to 2 meters long and runs  vertically.  When I opened the septic tank the existing wate r leaves and solids level was at the current outlet invert level. Determination | Case number: 754458 Page 9 of 13 Report Findings  If the septic tank had a substantial leak the level would be lower than the septic tank outlet invert level. Building consultant (AB) roof report 05.10. 2020  Insured reported water ingress to the ceiling space during rain events over the bedroom on south west corner of dwelling.  Caus e of water ingress is wind driven rain ent ering the ceiling space through the gaps between the trim deck roof sheets and the batten where the gutter is lower th an the roof sheets.  During the spray test to the roof a small amount of water made of between the Trimdek roofing and batten into the soffit.  No water made it to the bedroom however over prolonged periods of rain I can see how this would allow water to eve ntually run into the ceiling space in the corner of bedroom Geotechnical engineer (S) report 10.11. 2020  Site is moderately reactive ‘Class M’ soil from the testing done from the boreholes.  A difference in soil profile and soil moisture is present to the eastern and western sides of the house.  The western soil profile consists of more clay and has a higher moisture content compared to the eastern side of the house.  The eastern soil profile generally consists of more sand and has a lower moisture content compared to the western side of the house Engineer (KM) report 14.04. 2020 External  A vertical crack is visible in the top and face of the western wall footing.  Crack is in the middle point of the western wall.  Crack is approximately 10mm wide and is a consistent width over its height.  Crack is generally full of dirt and debris.  When the owner ran the hose in the top of the crack, water came through the western face crack.  The crack appears to be old as indicated by the discoloured concrete visible inside the crack, the rounded dull edges to the crack and the crack shape is a consistent width over its height.  A straight crack is visible in the top of the northern wall footing.  Crack is in the middle point of the northern wall (directly under some uneven pavers in the path bet ween the house and shed).  Crack is approximately 5mm wide and is a consistent width  Crack is generally full of dirt and debris.  When the owner ran the hose in the top of t he crack, the ponded water shortly drained through the crack when the hose is turned off.  The crack appears to be old as indicated by the discoloured concrete visible inside the crack in the rounded dull edges to the crack.  Uneven pavers are visible in thr ee (3) locations in the nort hern path between the house and shed.  One (1) location of uneven pavers is against the northern wall of the house. These pavers were removed by the owner and Determination | Case number: 754458 Page 10 of 13 Report Findings exposed the crack discovered in the northern wall footing.  Two (2) loc ations of uneven pavers is against the southern wall of the shed.  A gap is visible between the house slab and footings along the western and southern side where it is exposed.  Gap varies in width from 2mm wide in the south eastern corner and up to 30mm wid e in the north western corner.  The gap appears to be old as indicated by the discoloured concrete and build - up of dirt inside the gap.  No reinforcement is visible in the gap.  Diagonal cracking is visible in the external wall cladding.  Cracks are generally diagonal and occur at the lower corners of the wall cladding (generally cracks occur ~100mm away from the corners).  Some of the cracks occur at screw fixing locations.  Paint is visible inside some of the cracks. In other loc ations no paint is visible insid e the cracks.  Cracking is visible in the paint over the FC sheet joint cover strips to the external wall cladding.  The sanitary drainage pipe has a temporary repair with a flexible pipe where it enters the ground from the house. The owner reported that the y noticed the crack in the pipe after the February 2020 reported rain event. Internal  A straight crack is visible in the concrete slab to the nort hern edge of the living room where the owner pulled back the vinyl floor covering to expose the slab.  The crack is up to 0.5mm wide and opens towards the north.  The crack is visible in the external exposed northern edge of the slab. The crack in the expos ed edge opens towards the top of the slab.  Cracking and gaps are generally visible to the internal finishes to the house in locations.  Cracks occur in the ceiling cornice mitre joints and splice joints.  The cracks are generally up to 1mm wide (reported to have occurred in February 2020). Prior repair is visible in locations.  Gaps visible in the joint between th e ceiling cornice and wall / ceiling lining. The gaps are up to 4mm wide and generally are 1mm wide (reported to have occurred in February 2020).  The gap in the laundry ceiling cornice and wall / ceiling lining is up to 7mm wide (reported to have  occurred in December 2019).  Cracks are visible in the paint over the cover strip joints to the ceiling and wall lining. The cracks are generally up to 1mm wide (reported to have occurred in February 2020). Internal floor level survey  An internal floor level survey has been conducted by us on 30 March 2020. Refer to Appendix B for the reduced internal floor Determination | Case number: 754458 Page 11 of 13 Report Findings level survey plan. The survey results are summarised below.  The floor has a 58mm vertical difference in height.  The lowest point in the floor is in the eastern e dge of the laundry.  The highest point in the floor is along the western edge of the living room.  The floor is locally sloping 58mm from the highest to lowest point in the floor over 6 .3m. This equates to a localised floor slope deviation of 1 in 109.  Hous e floor is generally sloping towards the eastern edge of the laundry.  Eastern edge of the house is generally lower than the western edge of the house. Engineer (KM) second report 10.11. 2020  Damage to the hous e cannot be attributed to the single storm event.  Damage cannot be attributed to the plumbing leaks detected.  Both conclusions are still valid given the additional information provided by S and recent floor level survey.  The damage to the house would have occurred over its life and is attributed t o natural ground movement and the construction method. Engineer (BES) report provided by complainants 13.10. 2020  The investigation was focused on determining the cause for what appears to be substantial slab movement resulting in large cracking through t he residence.  There has been major soil movement to the property, resulting in the front LHS corner of the slab appearing to have separat ed from the footings supporting it.  This coincides with the back RHS corner of the slab appearing to have undergone soil settlement.  The combination of the two events, have resulted in large cracks spreading throughout the residence, both in the foundation slab, as well as in the walls.  Fur ther damage to the structure appears to be in the form of tiles cracking/falling off walls due to the differential movement.  There is also water damage to the ceiling, which the property owner has advised only occurs now due to the combination of the exten t of differential movement undergone by the slab and the low - pitched roof system currently installed now not having sufficient fall to prevent water penetration.  This water penetration has led to mould being present wit hin the property.  The surrounding soi l area appears to be really dry, with surface cracks evident towards the front of the property.  There is also localized areas of soil mounds and valleys present in the neighbouring fields. This indicat es that the site is likely to undergo large amounts of seasonal movement.  During the site investigation, it was noted that there were some cracked/broken plumbing pipes at the rear RHS corner (where the slab and footings appear to have settled). This leads to an Determination | Case number: 754458 Page 12 of 13 Report Findings underground wat er/sceptic tank. The exact condi tion of the tank is unknown at the time of writing this report.  The owner advised that there has been an extreme weather event in February, resulting in a very significant amount of rainfall in a short period of time. This extreme weather event coupled wit h the extremely dry soils pres ent would result in very large amounts of soil swelling over a small period of time.  Based off the findings from the site investigation as well as the information provided by the owner, it is my belief that the structure needs immediat e rectification works to enable people to continue living within.  The cause of the damage to the property is most likely due to the extreme weather event resulting in large soil movement which in turn, has res ulted in damage occurring to the prop erty.  This initial damage has quite likely caused cracking to the pipes mentioned earlier in this report, which could be leading to a continuation of the effects/worsening of the effects from the initial damage that occurred. Hygieni st (CFE) report 18.10. 2020 It is our considered opinion that:  there is very limited evidence of significant mould contamination in the residence that would be a result of water entering the building via the roof above the northwest corner of Bedroom 1;  there is little evi dence to support the proposed scenario of water flowing from the western side of the Residenc e to cause mould growth in the bathroom. It is more probable that mould growth in the bathroom is a result of water condensing on the cooler surfaces of the bathr oom aft er use, and/or as a result of not turning off water taps that would produce elevated Relative Humidity in the bathroom. It would be expected that any mould growth due to these conditions will re - occur and would be more prevalent in winter. Factors that may reduce the probability of mould growth in this room include:  the installation and proper operation of an appropriately sized exhaust fan.  the installation and proper operation of heat lamps.  the installation of insulation in the ceiling. While th ere was no evidenc e of mould growth in the surface samples, the elevated concent ration of settled spores on the carpet gripper in Bedroom 1 may be attributed to water damage. This area would need to be appropriately remediated. Elevated concentrations of airborne mould in the residence are most probably a combination of –  fungal structures entering the residence from an outdoor source,  the re - suspension of fungal structures and other particulat e matter during the ins pection activities of other persons. Determination | Case number: 754458 Page 13 of 13 Report Findings The most practical way to confirm whether water is leaking through the roof and flowing over to the bathroom is by removing roofing sheets above the north - west corner of Bedroom 1 and inspecting the ceiling space. If substantial water damage is found in th e area, then damaged areas of the ceiling and adjacent walls may have to be removed and the area remediat ed. If the claim is deemed to be an insurable event, then mak e safe operations on the roof must be undertaken to ensure future precipitation events do not cause further damage to the house. Building consultant (X) report 25.1.2121  refer to section 2.2 of determination

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.