Determination 741883

Claim declined for fire damage to rear mounted compressor under wear, tear, rust or corrosion exclusion

FirmQBE
Decided2020-12-15
ProductGeneral Insurance · Business / commercial
OutcomeFor the complainant
Amount awarded—
Non-financial loss—
Amount claimed—
SourceAFCA PDF

Summary

A business complainant's compressor was damaged by fire and the insurer declined under a wear, tear and corrosion exclusion based on a forensic engineer's report. AFCA found the insurer had not established the exclusion applies and ordered the insurer to meet the claim under the policy.

The insurer bears the onus of establishing an exclusion, and potential causes identified by its expert do not establish on balance that wear and tear caused the fire.

Issues

Subjects and remedies

small businesspay claim

Related

All QBE determinations · Find similar determinations

Text of the determination

Determination Case number 741883 Financial firm QBE Insurance (Australia) Limited Determination | Case number: 741883 Page 2 of 10 Case number: 741883 15 December 2020 1 Determination overview 1.1 Complaint The complainant holds a heavy fleet and haulage insurance policy with the financial firm (insurer), which provides coverage in the event of accidental loss and damage. The complainant submitted a claim for damage as a result of a rear mounted compressor (the Compressor) catching fire on 2 February 2020. It was uncertain of how the fire in the Compressor started, therefore the insurer instructed a forensic engineer to assess the cause of the damage. As a result of the engineer’s findings, the insurer declined the claim based on an exclusion in the policy for depreciation, wear, tear, rust or corrosion. A dispute has arisen as the complainant says the proximate cause of the damage was the fire, which is covered under the policy. Accordingly, the complainant says the damage should be covered and the claim paid. The complainant is represented by a broker and reference to the complainant in this Determination is reference to both parties 1.2 Issues and key findings Does the complainant have a valid claim? Yes. There is no dispute the complainant has established a valid claim under the terms of the policy. The policy provides cover for accidental damage and the damage sustained to the Compressor accidental. Is the insurer entitled to deny the claim? No. Based on the available information I am not satisfied the likely cause of the damage to the Compressor is excluded under the policy. 1.3 Determination This determination is in favour of the complainant. The insurer is to meet the claim under the terms of the policy. Determination | Case number: 741883 Page 3 of 10 2 Reasons for determination I have decided this case based on what is fair in all the circumstances, having regard to the relevant legal principles, good industry practice, industry codes of practice and previous relevant decisions of AFCA and predecessor schemes. I have considered all material submitted by the parties. I am satisfied the documentation I have relied on has been provided to both parties. 2.1 Does the complainant have a valid claim? The complainant has established a valid claim It is well established in insurance law that an insured has the onus of establishing that they have suffered a loss caused by an event which the policy covers. This is called a prima facie or valid claim. The complainant has comprehensive cover under the policy, which provides cover for accidental loss or damage. Accidental loss or damage is not specifically defined in the policy but is typically known to mean damage that is the consequence of an unforeseen or unintended happening. I am satisfied the fire was accidental for the purposes of the policy. The complainant has established a valid claim under the policy on the information provided. The insurer’s onus is to establish the basis on which it otherwise seeks to deny the claim, including the application of any policy exclusion. 2.2 Is the insurer entitled to deny the claim? Insurer refers to exclusion for depreciation, wear, tear, rust or corrosion On the basis the complainant has a valid claim for damage to the Compressor, the onus moves to the insurer to establish either an exclusion applies, or it is otherwise entitled to decline the claim. It is not disputed that a fire has caused damage to the Compressor. The question is in relation to the cause of the fire and therefore, whether the cause is excluded. The insurer has referred to exclusions in the policy relating to depreciation, wear, tear, rust or corrosion to decline the complainant’s claim. The insurer says the lack of regular maintenance has contributed to the failure of the Compressor, resulting in damage from fire. In reaching its position, the insurer has relied upon an asse ssor’s report from A and the reports of a forensic engineer (K). In K’s r eport and further supplementary report, the engineer indicates several factors that have had significant effect to the resultant fire, which K says are related to lack of maintenance. K lists the following factors to have contributed to the fire: Determination | Case number: 741883 Page 4 of 10  Separator and filter out of test date since 2013  Lack of maintenance records since 2015 and 2018 respectively.  Pressure switches encapsulated in dirt.  Rotors of compressor oxidised (rusted) K essentially concludes that the filter within the separator was not maintained, and as such the Compressor failed as a result of lack of appropriate maintenance. Whilst K has come to this conclusion the complainant says that neither A or K have shown how the lack of maintenance led to the fire. A was unable to determine the cause of the fire and that was the reason K was asked to inspect the machinery. K’s report provided as follows in relation to the examination and causation: Compressor Examination: 1. As the compressor was assembled with only the separator housing top flange removed it was necessary to dismantle the compressor whilst on site, to make a definitive decision that the insurer could effectively consider. The parts are heavy and required the implementation of primitive adaptors and lifting equipment to facilitate this dismantling process. Determination could not occur other than workshop intervention that was not possible. 2. Initial examination of the oil separator filter, determined that ignition of the element had occurred resultant of oil vapour ignition. As fire and the primary ignition requires the three elements of Oxygen, Fuel, and an Ignition source, it was determined that this was the primary area of ignition. The non-definitive point that this ignition relates to, is related to causation that I will later address. As the element is combustible to a limited degree the area of ignition has concealed the primary cause. This element is an entrapment filter and should be replaced at specified intervals, albeit no record of its changing has been recorded on any documentation received. 3 . Screw compressors have large helical rotors that generate the pressure. A common failure of this type of compressor relates to the helical gear bearings. To confirm thi s, it was necessary t o make i ntrusi on i nto this area by dismantling. With the assistance of site staff, we were able to remove the end casings of the stator and extract the helical gears to Determination | Case number: 741883 Page 5 of 10 determine, if a bearing failure had occurred. This failure usually is exhibited by the helical rotors establishing contact with a high frictional contact occurring, this did not occur. On extraction the surfaces of the helical rotors did not exhibit any influence of male to female contact which is normally exhibited by galling (scoring), this has not occurred. Close inspection of the rotors revealed the presence of oxidisation(rust) which is illustrative of moisture being present in the system or in the alternative high humidly environment. 4. Examination of the intercooler matrix did not reveal any evidence of degradation that would impede the cooling effect. 5. Examination of the rotor roller bearings exhibited scoring consequent upon general wear, however to the degree that would cause a contact between the rotors when rotating, as the rotors do not illustrate any evidence of surface to surface contact. 6. The capillary that senses the temperature of the air on discharge was not removed due to the obse se rvations made when we extracted the compressor rotors , notwithstanding no test facilities were available. 7. The pressure sensors on the unit were devoid of appropriate covers and would have warranted replacement at a preceding time. 8. From my observations the oil separator is a classified pressure vessel, under the Pressure Vessel CodeAS3788 -2006 relates that the pressure _ vessel/separator should be subjected to statutory testing to comply . The label on the side of the receiver relates it was last due for testing in 2013. 9. The safety pressure relief valve on the side of the separator that relieves any pressure is seized, thereafter did not illustrate any evidence of venting, resultant of the fire · event that occurred Causation: In eliminating the prevailing factors, I have taken into consideration the following potentials of failure: 1. Hole in oil filter separator providing a high velocity airflow resulting in localised overtemperature. 2. Static discharge. Determination | Case number: 741883 Page 6 of 10 3. Failure of oil temperature sensor increasing oil temperature at oil separator. 4. Failure of air temperature sensor, allowing compressor to have a high discharge temperature. 5. Failure of separator safety valve to operate and relief pressure preceding ignition. 6. Oxidisation in system due to moisture accumulation. 7. No documented evidence that separator filter was replaced in October 2017 as recommended by manufacturer … Complainant disagrees with forensic engineer’s findings K refers to the separator and filter being overdue for testing since 2013. The complainant’s Pumps Manager (W), who carries out the maintenance on this machine says the element was changed at 2908 hours, the next change due at 3908 hours (as per the service report of 02.10.2015 . At the time, the machine was at 3545 hours) . However , looking at the service report, it states the ne x t service was due at 3150 hours. The information provided does not show the service occurred at 3150 hours. I am satisfied the service was therefore overdue. Further, W says the “ m achine has only done 650Hr s since 2015 and has had 4 services between now and then. The machine was fully serviced before going out to the job when it failed after only 50Hrs of operation .” K points out that the services history pr ovided are in reference to the Compressor and the engine that drives the compressor. That is, although there have been invoices provided to show service history subsequent to 2015, there has been no information provided to evidence further service performed specifically on the Compressor or the s eparator, being the subject of the claim. The complainant is unable to determine the cause of the fire and maintains the fire is the proximate cause of the damage. The complainant has not provided information regarding W’s qualifications and as such has not provided expert opinion in contradiction to the conclusions provided by K. Insurer has not established exclusion applies The insurer’s expert K provided two reports, both of which conclude that the fire and subsequent damage occurred as a result wear and tear and corrosion. K says that the wear and tear came about as result of a lack of maintenance. T he complainant’s Pu mp Manager has provided comment to dispute these findings. Determination | Case number: 741883 Page 7 of 10 Ultimately, the K concluded the fire was caused by wear and tear because of lack of maintenance. Unfortunately, K’s conclusion provides a detailed examination, but he does not show how the wear and tear and lack of maintenance led to the fire. He has a list of what he refers to as “potentials of failure . ” My concern is that he has not been able to provide, on balance, a definitive explanation of what caused the fire. The fact the machinery may not have been maintained does not of its self, lead to a conclusion that that was what caused the fire. The “potentials of failure” are n o more than potential reasons for the fire. The policy provides for accidental damage (subject to exclusions) which is an unforeseen or unintended happening. The insurer has not argued that the fire was foreseeable or intended, nor would I expect them to. K was not able to dismantle the machinery and without this having occurred it is difficult determine what happened. The insurer has not been able to directly link the fire to the lack of maintenance and wear and tear. It is a possibility but, on the information provided, on balance I am not convinced the wear and tear led to the damage In the absence of any information to the contrary, the conclusion that the proximate damage was caused by the unexplained fire, not any wear and tear, is compelling. I therefore accept, based on the information provided, the insurer has not established the exclusion applies and is not entitled to decline the claim. Determination | Case number: 741883 Page 8 of 10 3 Supporting information 3.1 Key policy sections Page 8, PDS Types of cover We offer several different types of cover, as described below. The type of cover you have selected is shown on the Policy Schedule. 1. Comprehensive - All sections of this Policy will operate. This cover provides: (a) insurance against theft or accidental loss or damage to your vehicle, […] The causes of events not covered are described under 'What you are not insured against' and the 'General exclusions'. Page 14, PDS: General Exclusions Additional exclusions applying to all sections of this Policy This Policy does not cover: 2. loss of or damage to your vehicle due to depreciation, wear, tear, rust or corrosion, 3.2 Key expert reports Record Key points Insurer’s expert (A) Report (undated email)  From our inspection we are unable to determine the cause of the Fire.  We requested that a Forensic Engineer be appoint ed and determine the cause of the fire.  The Compressor appears to have a Poor Service History as Separator and Filter out of Test date since 2013. Determination | Case number: 741883 Page 9 of 10 Record Key points Insurer’s expert (K ) Report 02.04. 2020  I nitial examination of the oil separat or filter, determined that ignition of the element had occurred resultant of oil vapour ignition.  From my observations the oil separator is a classified pressure vessel, under the Pressure Vessel CodeAS3788 - 2006 relates that the pressure _vessel/separator should be subjected to statutory testing to comply. The label on the side of the receiver relates it was last due for testing in 2013.  The safety pressure relief valve on the side of the separator that relieves any pressure is seized, the reafter did not illustrate any evidence of venting, resultant of the fire ·event that occurred  The following factors to have contributed to the fire:  Separator and filter out of test date since 2013  Lack of maintenance records since 2015 and 2018 respectiv ely.  Pressure switches encapsulated in dirt.  Rotors of compressor oxidised (rusted)  A compressor of this age, should require manufacturers intervention to ensure reliability and safety.  From my examination the abovementioned factors contributed to the ine vitable failure. Insurer’s expert (K ) Supplement ary report 01.05. 2020  The compressor comprises of two main components, being that of the compressor that generates high pressure air to power the drilling head motor. The second component is the engine which drives the compressor, this is a separate component. The failure occurred within the compressor only.  In reading this transmission it must be perceived that you should only interpret that we have three components being the Air Compressor and Drive engine , thereafter the Truck engine. The tax invoices place this into confusion and must be segregated into the respective components.  latest work undertaken on this Compressor and Drive engine that was undertaken on 19 - 9 - 19. The work undertaken by MTR relates predominantly to the Truck engine and suspension components  On 23 - 9 - 19 Service truck as per check list> Remove exhaust and muffl er from compressor motor repair and weld. This is the drive engine for the compressor, Not the compressor that compresses the air.  The latest “maintenance” undert aken on the Compressor is dated Determination | Case number: 741883 Page 10 of 10 Record Key points 27 - 3 - 19 where the engine was subjected to an oil and filter c hange on the engine only >No repairs were undertaken on the Compressor itself.  Oil in a compressor is hygroscopic relating that it will absorb moisture. The oxidisation /rust evident on the rotors, clearly signifies lack of maintenanc e.  The condition of t he safety controls does not exhibit a good or any standard of maintenance on this unit.  The Separator was due for testing in 2013 and was not undertaken.  The safety valve that relates to any overpressure in the Separator is also seized.  I retain my opinion that the filter wit hin the separator was not maintained, thereafter this compressor unit sustained failure consequent upon lack of appropriate maint enance by the respective agent. Complainant’s expert (W ) Email DD Month YYYY  [re:] Separator and fi lter out of test since 2013 : Element changed at 2908Hrs next due at 3908Hrs as per attached service report (machine now has 3545Hrs)  [re:] Lack of maintenance records since 2015 and 2018 respecti vely Machine has only done 650Hrs since 2015 and has had 4 se rvices between now and then. The machine was fully serviced before going out to the job when it failed after only 50Hrs of operation (Info attached)  [re:] Pre ssure switch encapsulated in dirt Still operational and would not turn off if there was an interna l fire anyway  [re:] Rotors of compre ssor oxidized (rusted) Does not affect the operation or cause internal fire  The rotor and compressor were not fully disassembled to determine the cause of the internal fire, I don’t know how a conclusion could be ascert a ined if the complete air end is not disassembled and checked for damage or failure.  if anything, we have over servic ed the mac hine. Oil vapor could be the cause of the fire but not caused from the filter as it has only had 565Hrs use.  The rotors were rusty when pulled out, this would be from having a fire in the system and then the machine sitting around for a long time before been inspected.

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.