Home / QBE / Determination 741883
Determination 741883
Claim declined for fire damage to rear mounted compressor under wear, tear, rust or corrosion exclusion
Summary
A business complainant's compressor was damaged by fire and the insurer declined under a wear, tear and corrosion exclusion based on a forensic engineer's report. AFCA found the insurer had not established the exclusion applies and ordered the insurer to meet the claim under the policy.
The insurer bears the onus of establishing an exclusion, and potential causes identified by its expert do not establish on balance that wear and tear caused the fire.
Issues
- Claim denial primary · upheld“The insurer has not been able to directly link the fire to the lack of maintenance and wear and tear.”
- Inadequate claim investigation secondary · upheld“K's conclusion provides a detailed examination, but he does not show how the wear and tear and lack of maintenance led to the fire.”
Subjects and remedies
small businesspay claim
Related
Text of the determination
Determination
Case number 741883
Financial firm QBE Insurance (Australia) Limited
Determination | Case number: 741883 Page 2 of 10
Case number: 741883 15 December 2020
1 Determination overview
1.1 Complaint
The complainant holds a heavy fleet and haulage insurance policy with the financial
firm (insurer), which provides coverage in the event of accidental loss and damage.
The complainant submitted a claim for damage as a result of a rear mounted
compressor (the Compressor) catching fire on 2 February 2020.
It was uncertain of how the fire in the Compressor started, therefore the insurer
instructed a forensic engineer to assess the cause of the damage.
As a result of the engineer’s findings, the insurer declined the claim based on an
exclusion in the policy for depreciation, wear, tear, rust or corrosion.
A dispute has arisen as the complainant says the proximate cause of the damage
was the fire, which is covered under the policy. Accordingly, the complainant says the
damage should be covered and the claim paid. The complainant is represented by a
broker and reference to the complainant in this Determination is reference to both
parties
1.2 Issues and key findings
Does the complainant have a valid claim?
Yes. There is no dispute the complainant has established a valid claim under the
terms of the policy. The policy provides cover for accidental damage and the damage
sustained to the Compressor accidental.
Is the insurer entitled to deny the claim?
No. Based on the available information I am not satisfied the likely cause of the
damage to the Compressor is excluded under the policy.
1.3 Determination
This determination is in favour of the complainant.
The insurer is to meet the claim under the terms of the policy.
Determination | Case number: 741883 Page 3 of 10
2 Reasons for determination
I have decided this case based on what is fair in all the circumstances, having regard
to the relevant legal principles, good industry practice, industry codes of practice and
previous relevant decisions of AFCA and predecessor schemes. I have considered all
material submitted by the parties. I am satisfied the documentation I have relied on
has been provided to both parties.
2.1 Does the complainant have a valid claim?
The complainant has established a valid claim
It is well established in insurance law that an insured has the onus of establishing that
they have suffered a loss caused by an event which the policy covers. This is called a
prima facie or valid claim.
The complainant has comprehensive cover under the policy, which provides cover for
accidental loss or damage. Accidental loss or damage is not specifically defined in the
policy but is typically known to mean damage that is the consequence of an
unforeseen or unintended happening.
I am satisfied the fire was accidental for the purposes of the policy. The complainant
has established a valid claim under the policy on the information provided.
The insurer’s onus is to establish the basis on which it otherwise seeks to deny the
claim, including the application of any policy exclusion.
2.2 Is the insurer entitled to deny the claim?
Insurer refers to exclusion for depreciation, wear, tear, rust or corrosion
On the basis the complainant has a valid claim for damage to the Compressor, the
onus moves to the insurer to establish either an exclusion applies, or it is otherwise
entitled to decline the claim.
It is not disputed that a fire has caused damage to the Compressor. The question is in
relation to the cause of the fire and therefore, whether the cause is excluded. The
insurer has referred to exclusions in the policy relating to depreciation, wear, tear, rust
or corrosion to decline the complainant’s claim. The insurer says the lack of regular
maintenance has contributed to the failure of the Compressor, resulting in damage
from fire.
In reaching its position, the insurer has relied upon an asse ssor’s report from A and
the reports of a forensic engineer (K). In K’s r eport and further supplementary report,
the engineer indicates several factors that have had significant effect to the resultant
fire, which K says are related to lack of maintenance. K lists the following factors to
have contributed to the fire:
Determination | Case number: 741883 Page 4 of 10
Separator and filter out of test date since 2013
Lack of maintenance records since 2015 and 2018 respectively.
Pressure switches encapsulated in dirt.
Rotors of compressor oxidised (rusted)
K essentially concludes that the filter within the separator was not maintained, and as
such the Compressor failed as a result of lack of appropriate maintenance.
Whilst K has come to this conclusion the complainant says that neither A or K have
shown how the lack of maintenance led to the fire.
A was unable to determine the cause of the fire and that was the reason K was asked
to inspect the machinery.
K’s report provided as follows in relation to the examination and causation:
Compressor Examination:
1. As the compressor was assembled with only the separator housing top
flange removed it was necessary to dismantle the compressor whilst on site,
to make a definitive decision that the insurer could effectively consider. The
parts are heavy and required the implementation of primitive adaptors
and lifting equipment to facilitate this dismantling process. Determination
could not occur other than workshop intervention that was not possible.
2. Initial examination of the oil separator filter, determined that ignition of
the element had occurred resultant of oil vapour ignition. As fire and the
primary ignition requires the three elements of Oxygen, Fuel, and an
Ignition source, it was determined that this was the primary area of
ignition. The non-definitive point that this ignition relates to, is related to
causation that I will later address.
As the element is combustible to a limited degree the area of ignition
has concealed the primary cause. This element is an entrapment filter
and should be replaced at specified intervals, albeit no record of its
changing has been recorded on any documentation received.
3 . Screw compressors have large helical rotors that generate the
pressure.
A common failure of this type of compressor relates to the helical gear
bearings. To confirm thi s, it was necessary t o make i ntrusi on i nto
this area by dismantling. With the assistance of site staff, we were able
to
remove the end casings of the stator and extract the helical gears to
Determination | Case number: 741883 Page 5 of 10
determine, if a bearing failure had occurred. This failure usually is
exhibited by the helical rotors establishing contact with a high frictional
contact occurring, this did not occur.
On extraction the surfaces of the helical rotors did not exhibit any
influence of male to female contact which is normally exhibited by galling
(scoring), this has not occurred. Close inspection of the rotors revealed
the presence of oxidisation(rust) which is illustrative of moisture being
present in the system or in the alternative high humidly environment.
4. Examination of the intercooler matrix did not reveal any evidence of
degradation that would impede the cooling effect.
5. Examination of the rotor roller bearings exhibited scoring consequent
upon general wear, however to the degree that would cause a contact
between the rotors when rotating, as the rotors do not illustrate any
evidence of surface to surface contact.
6. The capillary that senses the temperature of the air on discharge was not removed
due to the obse se rvations made when we extracted the compressor rotors ,
notwithstanding no test facilities were available.
7. The pressure sensors on the unit were devoid of appropriate covers and
would have warranted replacement at a preceding time.
8. From my observations the oil separator is a classified pressure vessel, under
the Pressure Vessel CodeAS3788 -2006 relates that the pressure
_ vessel/separator should be subjected to statutory testing to comply . The
label on the side of the receiver relates it was last due for testing in 2013.
9. The safety pressure relief valve on the side of the separator that relieves
any pressure is seized, thereafter did not illustrate any evidence of venting,
resultant of the fire · event that occurred
Causation:
In eliminating the prevailing factors, I have taken into consideration the
following potentials of failure:
1. Hole in oil filter separator providing a high velocity airflow resulting in
localised overtemperature.
2. Static discharge.
Determination | Case number: 741883 Page 6 of 10
3. Failure of oil temperature sensor increasing oil temperature at oil
separator.
4. Failure of air temperature sensor, allowing compressor to have a high
discharge temperature.
5. Failure of separator safety valve to operate and relief pressure
preceding ignition.
6. Oxidisation in system due to moisture accumulation.
7. No documented evidence that separator filter was replaced in October
2017 as recommended by manufacturer …
Complainant disagrees with forensic engineer’s findings
K refers to the separator and filter being overdue for testing since 2013. The
complainant’s Pumps Manager (W), who carries out the maintenance on this machine
says the element was changed at 2908 hours, the next change due at 3908 hours (as
per the service report of 02.10.2015 . At the time, the machine was at 3545 hours) .
However , looking at the service report, it states the ne x t service was due at 3150
hours. The information provided does not show the service occurred at 3150 hours. I
am satisfied the service was therefore overdue. Further, W says the “ m achine has
only done 650Hr s since 2015 and has had 4 services between now and then. The
machine was fully serviced before going out to the job when it failed after only 50Hrs
of operation .” K points out that the services history pr ovided are in reference to the
Compressor and the engine that drives the compressor. That is, although there have
been invoices provided to show service history subsequent to 2015, there has been
no information provided to evidence further service performed specifically on the
Compressor or the s eparator, being the subject of the claim.
The complainant is unable to determine the cause of the fire and maintains the fire is
the proximate cause of the damage. The complainant has not provided information
regarding W’s qualifications and as such has not provided expert opinion in
contradiction to the conclusions provided by K.
Insurer has not established exclusion applies
The insurer’s expert K provided two reports, both of which conclude that the fire and
subsequent damage occurred as a result wear and tear and corrosion. K says that the
wear and tear came about as result of a lack of maintenance.
T he complainant’s Pu mp Manager has provided comment to dispute these findings.
Determination | Case number: 741883 Page 7 of 10
Ultimately, the K concluded the fire was caused by wear and tear because of lack of
maintenance.
Unfortunately, K’s conclusion provides a detailed examination, but he does not show
how the wear and tear and lack of maintenance led to the fire. He has a list of what he
refers to as “potentials of failure . ”
My concern is that he has not been able to provide, on balance, a definitive
explanation of what caused the fire. The fact the machinery may not have been
maintained does not of its self, lead to a conclusion that that was what caused the
fire. The “potentials of failure” are n o more than potential reasons for the fire.
The policy provides for accidental damage (subject to exclusions) which is an
unforeseen or unintended happening. The insurer has not argued that the fire was
foreseeable or intended, nor would I expect them to. K was not able to dismantle the
machinery and without this having occurred it is difficult determine what happened.
The insurer has not been able to directly link the fire to the lack of maintenance and
wear and tear. It is a possibility but, on the information provided, on balance I am not
convinced the wear and tear led to the damage
In the absence of any information to the contrary, the conclusion that the proximate
damage was caused by the unexplained fire, not any wear and tear, is compelling.
I therefore accept, based on the information provided, the insurer has not established
the exclusion applies and is not entitled to decline the claim.
Determination | Case number: 741883 Page 8 of 10
3 Supporting information
3.1 Key policy sections
Page 8, PDS
Types of cover
We offer several different types of cover, as described below. The type of cover
you have selected is shown on the Policy Schedule.
1. Comprehensive - All sections of this Policy will operate.
This cover provides:
(a) insurance against theft or accidental loss or damage to your vehicle,
[…]
The causes of events not covered are described under 'What you are not insured
against' and the 'General exclusions'.
Page 14, PDS:
General Exclusions
Additional exclusions applying to all sections of this Policy
This Policy does not cover:
2. loss of or damage to your vehicle due to depreciation, wear, tear, rust or
corrosion,
3.2 Key expert reports
Record Key points
Insurer’s expert (A)
Report
(undated email)
From our inspection we are unable to determine the cause of the
Fire.
We requested that a Forensic Engineer be appoint ed and
determine the cause of the fire.
The Compressor appears to have a Poor Service History as
Separator and Filter out of Test date since 2013.
Determination | Case number: 741883 Page 9 of 10
Record Key points
Insurer’s expert (K )
Report
02.04. 2020
I nitial examination of the oil separat or filter, determined that
ignition of the element had occurred resultant of oil vapour
ignition.
From my observations the oil separator is a classified pressure
vessel, under the Pressure Vessel CodeAS3788 - 2006 relates
that the pressure _vessel/separator should be subjected to
statutory testing to comply. The label on the side of the receiver
relates it was last due for testing in 2013.
The safety pressure relief valve on the side of the separator that
relieves any pressure is seized, the reafter did not illustrate any
evidence of venting, resultant of the fire ·event that occurred
The following factors to have contributed to the fire:
Separator and filter out of test date since 2013
Lack of maintenance records since 2015 and 2018
respectiv ely.
Pressure switches encapsulated in dirt.
Rotors of compressor oxidised (rusted)
A compressor of this age, should require manufacturers
intervention to ensure reliability and safety.
From my examination the abovementioned factors contributed to
the ine vitable failure.
Insurer’s expert (K )
Supplement ary report
01.05. 2020
The compressor comprises of two main components, being that
of the compressor that generates high pressure air to power the
drilling head motor. The second component is the engine which
drives the compressor, this is a separate component. The failure
occurred within the compressor only.
In reading this transmission it must be perceived that you should
only interpret that we have three components being the Air
Compressor and Drive engine , thereafter the Truck engine. The
tax invoices place this into confusion and must be segregated
into the respective components.
latest work undertaken on this Compressor and Drive engine that
was undertaken on 19 - 9 - 19. The work undertaken by MTR
relates predominantly to the Truck engine and suspension
components
On 23 - 9 - 19 Service truck as per check list> Remove exhaust and
muffl er from compressor motor repair and weld. This is the drive
engine for the compressor, Not the compressor that compresses
the air.
The latest “maintenance” undert aken on the Compressor is dated
Determination | Case number: 741883 Page 10 of 10
Record Key points
27 - 3 - 19 where the engine was subjected to an oil and filter
c hange on the engine only >No repairs were undertaken on the
Compressor itself.
Oil in a compressor is hygroscopic relating that it will absorb
moisture. The oxidisation /rust evident on the rotors, clearly
signifies lack of maintenanc e.
The condition of t he safety controls does not exhibit a good or
any standard of maintenance on this unit.
The Separator was due for testing in 2013 and was not
undertaken.
The safety valve that relates to any overpressure in the
Separator is also seized.
I retain my opinion that the filter wit hin the separator was not
maintained, thereafter this compressor unit sustained failure
consequent upon lack of appropriate maint enance by the
respective agent.
Complainant’s expert (W )
Email
DD Month YYYY
[re:] Separator and fi lter out of test since 2013 : Element
changed at 2908Hrs next due at 3908Hrs as per attached service
report (machine now has 3545Hrs)
[re:] Lack of maintenance records since 2015 and 2018
respecti vely Machine has only done 650Hrs since 2015 and has
had 4 se rvices between now and then. The machine was fully
serviced before going out to the job when it failed after only
50Hrs of operation (Info attached)
[re:] Pre ssure switch encapsulated in dirt Still operational and
would not turn off if there was an interna l fire anyway
[re:] Rotors of compre ssor oxidized (rusted) Does not affect
the operation or cause internal fire
The rotor and compressor were not fully disassembled to
determine the cause of the internal fire, I don’t know how a
conclusion could be ascert a ined if the complete air end is not
disassembled and checked for damage or failure.
if anything, we have over servic ed the mac hine. Oil vapor could
be the cause of the fire but not caused from the filter as it has
only had 565Hrs use.
The rotors were rusty when pulled out, this would be from having
a fire in the system and then the machine sitting around for a
long time before been inspected.