Text of the determination
Determination
Case number 726401
Financial firm Insurance Australia Limited
Determination | Case number: 726401 Page 2 of 16
Case number: 726401 3 September 2021
1 Determination overview
1.1 Complaint
The complainant holds a landlord residential insurance policy with the financial firm
(insurer)
In November 2016 he lodged a claim for damage to the property and for resulting loss
of rent. After investigating, the insurer declined the claim. The insurer says the
damage identified to the parapet and the wall of the property is from ground
movement and/or tree roots, and these are excluded under the policy. Further, it says
the property was never uninhabitable, so loss of rent is not payable, and even if it
were, it is capped at 12 months under the policy.
The complainant has repaired the property and it is re-let. He disagrees with the
insurer’s position and says the building damage was caused by the escape of liquid
from a neighbouring property, which is covered by the policy. As well, he says the
property was uninhabitable from the time he lodged the claim, and the policy covers
loss of rent until the date it was re-let.
1.2 Issues and key findings
Is the insurer entitled to deny the claim?
No. The insurer is not entitled to decline the claim. Although the expert reports refer to
a number of possible contributing factors, the available evidence establishes , on
balance, the proximate cause was the escape of water/liquid, which is covered under
the policy. The insurer has not established the exclusions apply.
Is the insurer required to pay loss of rent and other compensation?
Yes. The insurer is required to pay the complainant for 12 months of loss of rent in
accordance with the policy terms, together with interest on that in accordance with
section 57 of the Insurance Contracts Act 1984 (Cth) (the Act). Compensation of
$2,000 for non-financial loss is also warranted in the circumstances.
1.3 Determination
This determination is substantially in favour of the complainant. The insurer is
required to pay:
$159,733.20 for claim-related repairs, and $15,600 for loss of rent, together with
statutory interest on both these amounts, calculated as set out in section 2.1 below
the costs of the complainant’s 3 engineer reports (if not already paid)
$2,000 compensation for non-financial loss.
Determination | Case number: 726401 Page 3 of 16
2 Reasons for determination
2.1 Is the insurer entitled to decline the claim?
Complainant has established a valid claim
The policy provides broad cover for accidental damage, subject to exclusions and
conditions. The policy defines ‘ accidental loss or damage ’ as:
damage to, loss or destruction of the buildings when it is caused by an
unintentional act or an unforeseen and uncontrollable incident.
The policy goes on to state it also covers certain listed incidents under particular
conditions. Amongst those specified ‘incidents’ are:
Water or liquid damage
We will cover your buildings or contents for loss or damage caused by water or
liquid. We will also cover the cost of finding where the water or liquid escaped
from, including the cost of repairing any damage that occurs while looking for the
cause.
We will not cover your buildings or contents for loss or damage caused by
landslide or subsidence, unless we agree to cover the incident as described under
‘Landslide or subsidence’.
Storm, flood, rainwater or wind
We will cover your buildings or contents for loss or damage as a result of storm,
flood, rainwater or wind.
The complainant reported the initial damage as having occ urred in November 2016,
when bricks from the northern boundary parapet above the roof line of the insured
building were blown off during strong winds. Further investigation and invasive work
eventually identified additional, more extensive property damage.
Given the broad scope of cover under the policy, and the circumstances surrounding
the loss, the panel is satisfied the complainant has established a valid claim.
Insurer believes exclusions apply to entitle it to decline the claim
The onus then shifts to the insurer to establish it can rely on a policy exclusion, or is
otherwise entitled to deny the claim.
In this case the insurer relies on the following exclusions:
We will not cover any loss or damage as a result of, or caused by:
Determination | Case number: 726401 Page 4 of 16
• settling, shrink age or any movement of the earth
• erosion, rust, corrosion, gradual deterioration, depreciation, wear or tear…
• roots from trees, plants, shrubs or grass…
• landslide or subsidence, unless we agree to cover the incident as described
under landslide or subsidence…
The insurer first declined the claim on the basis the damage was from long-term
dilapidation, and therefore excluded as gradual deterioration and wear and tear.
Following further investigations, it said the cause of the damage to the property was
tree roots and resulting ground movement.
As well, the insurer says that cover for landslide or subsidence does not apply in this
case because that requires the damage to have occurred within 72 hours of the
relevant event:
Landslide or subsidence
We will cover your buildings or contents for loss or damage as a result of a
landslide or subsidence. We will only do this if the loss or damage occurs within
72 hours of: …
• a storm or flood, including rainwater or wind, or
• liquid escaping from a fixed pipe, or an object attached to a pipe, fixed gutter,
fixed tank or drain.
After subsequent evidence identified significant water escape into and through the
property, the insurer also submitted that cover should not apply since there was no
single escape of water/liquid incident. The policy defines ‘incident’ as:
A single occurrence or series of occurrences, including an accident or series of
accidents, arising out of one event.
Reports indicate several possible contributing causes of the damage
The insurer engaged a builder (AJ) to inspect and report on the property. The insurer
then engaged an engineer (CRD) who has produced two reports. The complainant
engaged an engineer (MC) who produced three reports.
The insurer’s first report from AJ is dated 12 December 2016. It says that the most
likely cause of the damage to the parapet is high winds. It notes that winds in the area
on the date the parapet collapsed were approximately 100km/ph.
Determination | Case number: 726401 Page 5 of 16
The insurer’s engineer, CRD, first provide d a report dated 23 January 2017, stating:
the cause of the damage to the wall and the parapet is long term dilapidation
the damage to the wall caused the parapet to collapse
there is a loss of mortar in the wall
there are cracks in the brickwork
the wall is double brick and the two layers of brick are no longer tied together
there is evidence of previous repairs.
CRD inspected the property again and provided a second report dated 1 April 2020
(over three years after the claim was lodged). By that time, significant and unusual
water entry under and around the building had been identified. Relevant points from
that report are:
the proximate cause of the elevated soil moisture is tree-related soil movement
which has displaced the sewerage and/or stormwater pipes on this property or the
adjacent property. This has led to compromised watertightness of those pipes and
water escape
the water present on the day of the inspection is recent and not causative of the
damage
the presence of a large tree (and its roots) would likely have reduced the water in
the soil over time causing settlement of the property
the soil (while not tested) is comprised of clay which is reactive to water ingress
there was long term reduction in the water around the foundation which created
abnormal moisture conditions around the perimeter of the property
mortar deterioration in the wall likely contributed to the damage.
The insurer summarised this as showing the soil had been exposed to large tree roots
which had caused it to dry over time, resulting in ground movement and the damage
to the wall and parapet (as well as significant cracking on both the internal and
external walls).
The insurer concluded that the tree roots were the proximate cause of the damage
and this is not listed event, but is excluded under the policy.
The complainant engaged MC to inspect the property, which was constructed in 1890.
MC ’s original report is dated 23 November 2017. At that time, MC considered that the
cracking and movement in the north boundary wall had likely resulted from a
combination of the following factors:
inherent weakness in the north wall structure caused by a lack of restraints
undermining of footings during construction of the adjoining residence
inadequate footings that could not withstand a change in moisture level
Determination | Case number: 726401 Page 6 of 16
footing movement, from differential soil shrinkage, expansion or settlement, caused
by seasonal changes in the moisture content of the foundation soils
significant vegetation in the form of a row of pencil pines growing adjacent the
north boundary wall on the adjoining property
significant large tree at the rear of the adjoining property
poor stormwater drainage maintenance of the property and the neighbouring
property.
MC re-attended and provided a second report on 26 August 2020. By that time,
underpinning work which the complainant had begun in January 2019 was still on-
going. This report includes reference to several detailed discussions MC had with a
representative of the complainant’s underpinning contractor (PPU), who was also
present at the time of the re-inspection. Those discussions (together with information
reported by the complainant to MC) reveal the significant extent of ongoing water
issues encountered in the course of the underpinning works. That includes PPU
saying that within days of e xcavations starting, they encountered ‘quite a lot of water’,
from an unknown source; water problems continued during work in other areas of the
property; there were delays as water repeatedly needed to be pumped from trenches;
and they had ‘real concerns’ about the volume of water encountered. The local water
authority then became involved and undertook investigations and testing, and PPU is
reported as emailing the complainant to say ‘…[the] water has obviously been the
cause of the footing problems’.
MC reports PPU told him that their experience of the past 3.5 years of underpinning
work at the complainant’s property was the worst water inundation they had
experienced, apart from a natural spring.
MC more specifically concludes that:
damage to the parapet brickwork occurred reportedly during strong winds, however
in our opinion the weather is not the proximate cause of this damage. In our
opinion, the saturation of the north wall’s foundation soils caused rotation of the
north wall’s fo otings, which reduced the stability of the parapet, and is the
proximate cause
subsurface observations during underpinning works clearly indicate water
inundation of the foundation soils, with water ingress from beyond the property
boundary (upslope) in the silts and fill overlying clay. This was not evident during
the initial inspection
there has been ongoing movement in this building, aerial imagery suggests the
north wall problem became significantly worse in 2016 leading to a collapse of the
parapet brickwork
the collapsed section of wall became significantly worse in a short period of time;
this suggests the problem has become significantly worse with water inundation
around that time
Determination | Case number: 726401 Page 7 of 16
significant water inundation had been occurring in foundation soils on this site. The
source of water was increased by a combination of sewerage leaking from upslope
vitreous clay pipes and possible leaks in internal water supply systems in adjacent
properties
the major cause of cracking and movement damage in this building is the water
ingress saturating the foundation soils and causing a loss of bearing capacity for
the footings.
In his final report of October 2020, MC concludes the time over which the leaks and
escape of water operated to cause the damage are dependent on several factors,
most of which cannot be known. However, given the rapid deterioration during the
2016 summer, MC is of the opinion that the leaks caused the damage over a short
period, most likely measured in months.
MC also acknowledged that, in their initial report, they had highlighted the possible
impact of trees. However, given their later inspection and ‘ subsurface observations of
the quantity of water in the foundation soils, and minimal tree root invasion ’ , they
considered the effects of vegetation to be minor.
The complainant relies on MC’s reports to say that the damage to both the wall and
parapet were caused by the escape of liquid from a neighbouring property and was
not as a result of ground movement, normal gradual deterioration and/or wear and
tear. (In the alternative, the complainant submits that AJ ’s report supports the
contention that the damage to the parapet was caused by wind and is covered under
the definition of storm.)
The panel also notes the video evidence provided by the complainant, taken in
February 2019, soon after excavation/underpinning works began; together with
photographs from February and April 2019, all showing significant water flowing
near/under the house. The complainant has said that issue occurred a number of
times: they dug out, noticed water flowing, then contacted the local water authority
and the water stopped flowing. That is supported by information from the local water
authority which confirms there were 5 leaking pipes at the neighbouring propert y(ies).
In response to MC ’s reports, the insurer says:
t he insured property’ s parapet was bowing as far back as November 2013
the policy covers subsidence damage caused by liquid escaping from a fixed pipe
only when the loss occurs within 72 hours of a leak
MC says the damage may be the result of as many as five separate leaks forming
over time, and the policy covers loss or damage caused by a single incident, so
this claim is outside the terms of the policy
settlement resulting from leaking stormwater or sewerage lines is very unlikely, as
the volume of liquid entering the soils is not enough to saturate them
Determination | Case number: 726401 Page 8 of 16
the cause(s) of these underground pipes failing can be summarised as gradual
deterioration and tree roots, which are both excluded by the policy wording. As the
pipes failed due to excluded factors, any loss attributable to the failed underground
pipes saturating the foundation soils would be excluded by the operation of the
policy wording
the proximate cause of the damage was tree roots and that is not a listed event so
the complainant has not established a valid claim.
I nsurer’s liability depends on the proximate cause of the damage
In order to determine w hether the complainant’s claim should be covered, it is
necessary to determine the proximate cause of the loss. Identifying the proximate
cause is the question of fact, depending upon the circumstances of each case.
It is well established that a proximate cause is not necessarily the first or last or the
sole cause of the loss. It is the effective, dominant or operative cause of the loss. If
there are several causes operating contemporaneously, then each must be examined
for the qualities of predominance and efficiency as the active efficient cause that sets
a relevant train of events in motion.
Courts have said that if one cause would have resulted in the harm in any case and
the other would not have done so in the absence of the first, then the first is t he
proximate cause.
There may also be circumstances where it is reasonable to conclude that there were
two causes which were equal or concurrent in their efficiency in bringing about the
damage. If one of those causes was an insured event, and the other an excluded
event, then the excluded event would prevail.
If it is not possible to identify which of two or more causes is the proximate cause then
they will be regarded as concurrent proximate causes. Concurrent causes can occur
where there are two or more events, each of which is independently capable of
causing the loss, or where there are two events each of which, without the other,
could not have caused the loss. In either case they are only concurrent if of equal
efficiency.
Damage was not from subsidence
The panel accepts MC’s position that sometime in 2016 there was a rapid and
substantial amount of saturation to the foundation soils. (This has not been shown to
have been a gradual process, and so cannot be excluded on that basis.) This is
consistent with a pipe(s) breaking at either the insured property or the neighbouring
property. As the observable external damage occurred in summer, it is unlikely that
poor stormwater drainage contributed to the damage in a meaningful way.
The panel also accepts that, due to the condition of the footings and the inherent
weakness in bearing the load of the wall (neither of which is unexpected given the
Determination | Case number: 726401 Page 9 of 16
age of the building), the property was susceptible to damage, and there may have
been some previous movement. However, the evidence suggests that without the
rapid initial escape of liquid and change in the moisture levels of foundation soil, this
damage would not have occurred when or to the extent it did.
It is also relevant to note MC’s clear statement that:
damage behaviour is consistent with saturation of foundation soils causing a loss of bearing
capacity and subsequent wall rotation. Footing settlement has occurred, soil settlement has
not occurred. Foundation soils have lost their bearing strength. We confirm soil subsidence
has not occurred.
In other words, MC’s professional opinion is that this was not a case of subsidence as
such. On that point, t he panel notes the insurer’s acknowledgement in its third denial
letter (of 1 October 2019) that the complainant did possibly have a valid claim for
water or liquid damage since that is not time-limited and it also allows for damage
caused by heave rather than subsidence.
The panel is satisfied, on balance, this was not a case of soil subsidence, and so the
insurer is not entitled to decline the claim on the basis that it did not occur within 72
hours of the escape of liquid.
Damage not shown to have been from tree roots
Another important question is whether the pipe(s), from which water had clearly been
escaping, burst as a result of the tree(s) at the complainant’s and neighbouring
properties. That is, without the trees taking moisture from the foundation soils over a
period of time, would the pipe(s) have burst in the first place?
While both CRD and initially MC refer to tree roots as likely being involved in the
damage to the property, they differ as to the degree of impact on the volatility of the
surrounding soil and on the pipes which might be attributable to the tree roots. It is
also worth noting that no specific soil testing was conducted to definitively gauge the
effect of that factor.
CRD considers there was long-term settlement of the foundation caused by tree roots
which was important in both weakening the footings and structure of the wall, as well
as contributing to the vulnerability of the pipe(s) that ultimately burst.
MC, on the other hand, emphasises the proximate cause of the damage was the rapid
inundation of the foundation soil from a burst pipe(s). While noting the presence of
trees in the area, MC does not accept these had any significant role in the damage to
the property. Importantly too, the available evidence does not actually show the tree
roots did cause damage to the pipes that burst/started leaking: there are, for example,
no photographs of pipes showing an encroachment of tree roots, or roots in the
vicinity.
Determination | Case number: 726401 Page 10 of 16
The panel does not accept it has been shown that the tree roots alone,
predominantly, or in equal measure with any other factor (if at all), were responsible
for the damage to the property.
Instead, the panel considers that the possible encroachment or spread of tree roots (if
any) would more likely than not be the result of the leaking pipes - in that the roots
would have followed the excess water – and not the cause.
Proximate cause of damage was escape of water/liquid
The panel is satisfied, on balance, the proximate cause of the damage to the building
was the escape of water/liquid from burst or leaking pipes. The panel considers that
represents an ‘unforeseen and uncontrollable incident’, consistent with the intended
broad policy cover for accidental damage.
The panel also notes that MC indicates he believes the majority of the water
inundation which has clearly occurred came from the neighbouring property, over
which the complainant does not have any authority or control.
Initial investigations, however, were not invasive or focussed enough to discover the
water issue at the time, but tended to rely instead on a range of possible contributing
factors (none of which has been shown, on the available evidence, to be concurrent
or equal in its efficiency in bringing about the damage). It was only in the course of the
complainant’s repair/underpinning works that the significant extent and impact of the
water became apparent. There is nothing to show that water ingress and impact was
only a recent development (that is, that it only happened since the observable building
damage occurred in 2016).
The insurer has submitted that there were several broken pipes and that does not
represent a single insured incident. The available evidence does point to a number of
leaking pipes in the vicinity of the complainant’s property, and it is not possible to
apportion responsibility for the damage to individual leaks. At the same time, on
balance, each leak was still an insured incident contributing to the resulting damage
to some degree.
In the particular circumstances, the panel is satisfied it is fair to treat the escape of
water as a single insured incident.
Fair and appropriate that insurer covers the claim-related damage
The complainant has paid for the repairs of the property totalling $196,173, although it
is not clear that all components of that total cost are specifically attributable to the
claim-related damage – for example, the floor sanding and carpeting, or painting.
However, $156,000 relates to underpinning – including locating and repairing the
cause of the damage, which the panel is satisfied should be covered as being the
result of the water/liquid escape. There are also several other components of costs
(totalling $2,895.20) which the panel considers should reasonably be included as
expenses for claim-related damage, each marked with a single asterisk in the
Determination | Case number: 726401 Page 11 of 16
complainant’s breakdown of costs which appears in section 3.2 of this determination
below.
In the particular circumstances, it is fair that the insurer pays $159,733.20 towards
claim-related repairs, subject to the complainant providing reasonable evidence of
having incurred those costs (such as invoices).
The insurer is also required to pay statutory interest on this amount (under section 57
of the Act). Interest is to be calculated from the date the complainant paid the relevant
repair invoices, until the date of settlement.
Insurer to pay the costs of the complainant’s expert reports
The complainant engaged MC to provide expert opinion in this matter. The panel
found these reports to be of assistance in determining this complaint. Under AFCA
Rul es, we may require the insurer to reimburse the complainant’s reasonable costs
incurred for these 3 reports.
In his breakdown of claim-related costs, the complainant has identified $4,467.10 for
MC’s reports (marked with a double asterisk in the complainan t’s breakdown of costs
in section 3.2 below). The panel is satisfied it is fair and appropriate that the insurer
also reimburses those costs (if they have not already been paid), subject to provision
of relevant invoices from the complainant.
2.2 Is the insurer required to compensate the complainant for loss of rent?
The complainant’s property was uninhabitable
The damage to the property was significant, including the collapse of part of the roof
and one wall of the property. The parties have provided photos of the property and
the panel accepts it was uninhabitable prior to the repairs being completed.
The policy restricts the loss of rent benefit to 12 months
The complainant argues he is entitled to loss of rent for 32 months, being from the
time the property was damaged until it was re-let. The amount claimed by the
complainant is $41,600 ($1,300 per month for 32 months).
However, the policy caps loss of rent payments at 12 months:
With this option, if your buildings or sections of your buildings suffer loss or
damage and are uninhabitable as a result, we will cover any loss of rent equal to
the weekly amount as stated on your rental agreement or periodic tenancy
agreement for up to 12 months. The most we will pay is the sum insured, as listed
on your schedule.
If you choose this option it will be listed on your schedule as ‘Loss of Rent’.
Determination | Case number: 726401 Page 12 of 16
This cover applies when:
• loss or damage to your buildings or contents occurs as a result of an incident as
listed in this PDS
• access to your rental property is preve nt due to loss or damage to other property
located near your rental property.
We will only cover loss of rent while your property is uninhabitable
On the complainant’s submissions , 12 months’ loss of rent would be $15,600. The
insurer is required to pay this amount (or such other amount as the following required
evidence shows is payable), subject to the complainant providing the insurer with a
copy of the lease agreement and proof of the amount payable by the tenant per
month.
It is fair the insurer should also pay statutory interest on the loss of rent amount,
calculated from the date the claim was first declined (28 January 2017) until
settlement.
Compensation for non-financial loss is warranted
The damage occurred in 2016. The complainant was living overseas at the time. He
returned to Australia and arranged extensive investigations into the cause. He paid for
all repairs and made the necessary applications, while also reverting to the insurer a
number of times to have the matter accepted.
The insurer has raised a number of exclusions (including another new one in its more
recent submissions), but has not established, on balance, that they apply to the
circumstances to entitle it to decline this claim.
In the meantime, the complainant has had the considerable inconvenience and
concern of attending to the claim-related repairs himself.
The panel considers it fair in the circumstances that the insurer pays $2,000 as
compensation for non-financial loss.
Determination | Case number: 726401 Page 13 of 16
3 Supporting information
3.1 AFCA approach
There has been a full exchange of all material information relied on for the purposes
of this determination and each party has had the opportunity to address any issues
raised by the other.
This decision has been made by a Panel consisting of an Ombudsman, a
representative with extensive experience in the insurance industry and another
representative with extensive experience in consumer claims.
The decision follows consideration of all the material exchanged. It is based on what
is fair in all the circumstances having regard to the relevant legal principles, terms of
the policy, good industry practice including codes of practice and previous decisions
where applicable.
While the parties have raised numerous issues in their submissions, for the purposes
of this determination, commentary has been restricted to those issues considered
directly relevant to the outcome.
3.2 Relevant documents
Complainant’s breakdown of repair costs he has paid
Item Cost Provider
* Remove/stack bricks, cover exposed area 451.00 BPR
Vacancy surcharge on insurance 172.70
** Structural Investigation Report 4,467.10 MC
* Underpinning of foundations, plus additional costs
re water ingress labour & time, re - stumping &
flooring
156,838.00 PPU
* CHW 24.20 Initial water tests
* Replace original brickwork, etc 2,420.00 RDB
Plumbing, incl brickwork flashing 4,213.00 PJC
Plastering 8,800.00 BAP
Floor sanding/polishing 1,985.00 BSFS
Painting repairs 13,167.00 CP
Determination | Case number: 726401 Page 14 of 16
Carpeting of rear room and 3 bedrooms 3,395.00 RDC
Repair window & frame, floor repairs 340.00 RJJ
Sub - Total $19 6 , 173 .00
Rental income foregone 4 1,60 0 01/07/17 – 27/02/20 = 32
months @ $1,300/month (this
assumes no indexation over
the period)
Total $2 37 , 773 .00
Engineering reports
Record Key points
AJR
12 December
2016
Damage to the property most likely caused by high winds
Winds in the area were recorded at approximately 100km/ph on the date of loss
CRD
23 January
2017
the cause of the damage to the wall and the parapet is long term dilapidation
the damage to the wall caus ed the parapet to collapse
there is a loss of mortar in the wall
there are cracks in the brickwork
the wall is double brick and the two layers of brick ar e no longer tied together
there is evidence of previous repairs.
CRD
1 August 2020 the proximate cause of the damage to the wall and parapet is excessive water in
the soil caused by damaged sewage or water pipes on a neighbouring property
caused by tree roots
the water present on the day of the inspection is recent and not causative of the
damage
the presence of a large tree (and its roots) would likely have reduced the water
in the soil over time causing settlement of the property
the soil (while not te sted) is comprised of clay which is reactive to water ingress
there was long term reduction in the water around the foundation which created
abnormal moisture conditions around the perimeter of the property
mortar deterioration in the wall likely contribut ed to the damage
MC
23 November
2017
The cracking and movement in the north boundary wall has likely resulted due to a
combination of the following factors:
Determination | Case number: 726401 Page 15 of 16
Record Key points
Inherent weakness in the north wall structure caused by a lack of regular
perpendicular restraints and lack of a robust cellular structure along the northern
wall;
Undermining of footings during construction of the adjoining residence;
Inadequate footings to resist adverse changes in the moisture content of the
foundation soils;
Footing movem ent, from differential soil shrinkage, expansion or settlement,
caused by seasonal changes in the moisture cont ent of the foundation soils and
exacerbated by abnormal soil moisture conditions from:
Significant vegetation in the form of a row of pencil pine s growing adjacent the
north boundary wall on the adjoining property;
Significant large tree at the rear of the adjoining property;
Poor stormwater drainage maintenanc e of 312 and 314 Neill Street including
built - up leaf debris in gutters, poor drainage tr apping stormwater adjacent
footings in the atrium of 314 Neill Street and gutters of 312 Neill Street holding
water, indicating spill over would occur
MC
26 August
2020
Damage to the parapet brickwork occurred reportedly during strong winds,
however in our opinion the weather is not the proximate cause of this damage.
In our opinion, the saturation of the north wall’s foundation soils caused rotation
of the north wall’s f ootings, which reduced the stability of the parapet, and is the
proximat e cause.
As the north wall rotated further out of alignment, the neighbouring property
started to provide some support to the wall. This applied pressure and stress to
the wall at the point of support. The parapet brickwork then being unrestrained
above roof level at the rear of the building and being significantly out of level and
with aged mortar, had reduc ed capacity to resist wind loads.
Whilst there has been ongoing movement in t his building, historic al aerial
imagery suggests the north wall problem became significantly worse in 2016
leading to a collapse of the parapet brickwork. Whilst there is some suggestion
of wall alignment issues from 2013 onwards, the collapsed section of wall
became significantly worse in a short period of time before the parapet collapse.
In our opinion, this suggests the problem has become signific antly wors e with
water inundation around this time.
The underpinning works provided subs urface observations and further site and
building observations.
Significant water inundation in the form of a perched water table had been
occurring in foundation soils on this site. The source of water wit hin the perched
water table had been artificially increased by a com bination of sewerage leaking
from upslope vit reous clay pipes and possible leaks in internal water supply
systems in adjacent properties.
In our opinion, from all the information available, the major cause of cracking
and movement damage in this building is the water ingress saturating the
foundation soils and causing a loss of bearing capacity for the footings. Water
ingress and saturation of the foundation soils had caused a change of
conditions, where an inherently weak footing system could no longer ad equately
Determination | Case number: 726401 Page 16 of 16
Record Key points
support the building loads.
MC
14 October
2020
The time the leaks would have needed to operate to cause this level of
movement is dependent on several factors, most of which are unknown.
The proximity of the leaks to the site, the leak volumes (as sewer leak volumes
are undetected) and the existing soil moisture levels. The bearing pressure
exerted by the building on the soils is relatively constant, therefore once
saturation of the clayey silt occurred to a level sufficient to cause a loss of
bearing capacity, the movement was triggered and could progress.
In our opinion, the significant water inundation during underpinning works in the
middle of summer indicates that the leak volumes were high and therefore the
time required to cause the move ment was relatively short.
In our opinion, if the leaks were from any of the upslope houses in this area, the
timeframe from the leak to the footing movement would be expected to be in the
order of months, rather than years .
Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.