Home / Defence Service Homes Insurance Scheme / Determination 724686

Determination 724686

Insurer declined cyclone claim for full replacement of upstairs particleboard flooring

FirmDefence Service Homes Insurance Scheme
Decided2021-04-14
ProductGeneral Insurance · Home building and contents
OutcomeFor the complainant in part
Amount awarded—
Non-financial loss$2,000
Amount claimed$226,228
SourceAFCA PDF

Summary

The complainants claimed cyclone damage to upstairs particleboard flooring and sought $226,227.70 for full replacement. AFCA found the insurer liable only for localised repair and ordered it to obtain a quote and cash settle the repair cost, plus $2,000 for non-financial loss from delays.

The expert evidence showed the cyclone caused only localised water damage at the sliding doors, so the policy covers partial repair rather than full replacement, while claim delays warranted compensation.

Issues

Subjects and remedies

home or building damagenatural disasterpay claimpay non financial loss

Related

All Defence Service Homes Insurance Scheme determinations · Find similar determinations

Text of the determination

Determination Case number 724686 Financial firm Defence Service Homes Insurance Scheme Determination | Case number: 724686 Page 2 of 14 Case number: 724686 24 March 2021 1 Determination overview 1.1 Complaint The complainants hold a home and contents policy with the financial firm (insurer). The complainants submitted a claim for the damage with the insurer sustained following Cyclone Debbie on 28 March 2017. The insurer accepted liability and has cash settled the claim for $405,185.04. The insurer has declined the claim for damage to the upstairs particleboard flooring and say it was not caused by an insured event. The complainants say the flooring must be replaced, was damaged during the Cyclone and this should be covered under the policy. The complainants seek cover for the cost to replace the flooring quoted at $226,227.70. 1.2 Issue and key findings Is the insurer entitled to deny liability for replacement of upper level flooring? No. The Panel damage to the upper particleboard flooring caused by the Cyclone was limited to water ingress surrounding the external sliding door openings. The insurer ‟s liability limited to sanding and partial replacement of the floor. The insurer is not liable to pay for a full replacement of the flooring. Are the complainants entitled to compensation for non-financial loss? Yes. The complainants have suffered an unusual degree of inconvenience and time taken to resolve the claim. It is fair in the circumstances the insurer pay $2,000 compensation for non-financial loss. 1.3 Determination This determination is substantially in favour of the Insurer. Within 14 days of the complainant‟s acceptance of this determination the insurer is to obtain an actionable quote to the repair to the damaged flooring located at the sliding door as set out in section 2.1 of this determination. The insurer can then cash settle the complainants for the cost of repairs. The insurer is to also pay the complainants‟ $2,000 compensation for non-financial loss. Determination | Case number: 724686 Page 3 of 14 2 Reasons for determination The complainants have been assisted by a representative. Reference to submissions by the complainants includes reference to the submissions by the representative. There has been a full exchange of material between the parties and each party has had the opportunity to address the issues raised. The matter has been referred to a Panel for determination. The Panel comprises the lead Ombudsman, a member with significant industry experience and a member with considerable experience as a consumer advocate. The Determination follows consideration of all relevant information. The determination is based on what is fair in all the circumstances having regard to the relevant legal principles, terms of the policy, good industry practice including codes of practice and prior determinations where applicable. 2.1 Is the insurer entitled to deny liability for replacement of upper level flooring? No dispute a storm event caused damage to the property The complainants home policy provides cover for a series of listed events including storm and rain as well as accidental damage subject to conditions and limitations. The complainant‟s property was affected by Cyclone Debbie in March 2017. This is not in dispute and a cyclone claim was accepted by the insurer. The insurer has cash settled the agreed damage for $405,185.04. The remaining issue in dispute is the damage to the particleboard flooring in the upstairs area of the house, what is required to repair that damage and whether any policy exclusions apply. Experts’ reports disagree on the extent and cause of damage Numerous expert reports have been exchanged and are summarised under section 3 of this determination. The complainants say the issue with the damage to the particle flooring and the hump in the flooring was raised at the time of the claim in April 2017, but the insurer ‟ s assessor refused to inspect the flooring. On 26 April 2017, the insurer‟s assessor A noted: “ a general hump which insured maintains has appeared since the cyclone in the particleboard floor (due to pressures from the cyclone). This hump is located directly outside the bathroom door in close proximity to the shower recess. Water from cyclone did not reach this area and carpet is still intact. ” Determination | Case number: 724686 Page 4 of 14 The insurer‟s engineer GT attended in June 2017 and reported the damage to the floor is due to long term water damage which has resulted from a failure in the bathroom‟s waterproof membrane. GT reported the issues are related to age or workmanship and not the cyclone event. GT did not inspect the roof or under the upper floor carpet. GT later inspected the roof and under the carpet. On 14 November 2017 GT reported that water likely did enter the roof during the cyclone event however found no evidence to suggest that this was in large quantities. GT did not find the presence of any mould. GT considered it possible the waterproofing in the bathroom could have caused damage over time. On review of the Council building file, GT noted a significant defect with the floor framing and believe this is more likely to be the proximate cause of the bulging. GT considered the cyclone could not be the cause of the damage to the particleboard upper flooring. GG, the complainants engineer reported in August 2019 that having inspected under the carpets he found water staining in the particle board floor by the adjacent windows and sliding doors. GG considered water ingress because of the cyclone damaged the particleboard flooring adjacent windows and sliding doors. The saturation of the carpets has caused damage to flooring adjacent to these ingress points. GG concluded the whole of the upper floor particleboard flooring would need to be replaced. GG did not provide detailed reasoning to explain why they have concluded the flooring requires full replacement. It is also noted that GG makes no reference to the Council building file in relation to the property. Following these reports, the insurer instructed another engineer (FC) to report as to the cause of the damaged particleboard and whether it required full replacement. FC was provided all the reports from GT and inspected the damaged flooring. FC found no structural damage or loss of structural integrity of the particleboard sheet flooring that would require complete replacement. The only areas of particleboard which were observed to have cyclone related damage were at the sliding doors, where the flooring has been cut and fitted into and around these door openings. FC says this was modest and very localised roof water ingress, and therefore it is not plausible that wind driven rain reached across and exposed the entire upper floor to rainwater. FC says the damaged flooring is suitable for repair rather than full replacement if the swelling is between 4-6mm. It is noted the complainant have provided photographs of the gapping, several instances in which distortion exceeds 6 -8mm and in 1-2 instances, appears to be as much as 10mm showing 10mm in some places. Conversely, FC reports measuring several locations to be less than 4mm. It is not known when the complainants measured the flooring in comparison to FC. FC considered the „hump‟ in the floor is a result of undersized floor joists combined with Determination | Case number: 724686 Page 5 of 14 the resulting abrupt change in floor deflection between the single spanning floor joists. This is reported as a latent building defect issue associated with the original construction and was not caused or exacerbated by the cyclone. Full replacement of upper flooring not warranted Having weighed all available information contained in the expert reports, the Panel accepts that while there is some damage to the particle board flooring it is not necessary to replace the entire floor. The Panel finds the report of FC to be most persuasive. FC reviewed all reports from GG and GT. The floor was dry when assessed and extensive photographs provided. FC met with the complainant‟s builder and acknowledged the carpet and particleboard was in part wet. FC pas provided detailed reasoning relating to the discolouration and swelling and raised issues of gapping and floor framing unrelated to the storm. FC provides a plausible explanation regarding the extent of the cyclone related damage to the flooring and repairs required. The insurer ‟s liability is limited to sanding and partial replacement of the floor. The insurer is not liable to pay for a full replacement of the flooring. The insurer is to obtain an actionable quote from its builder to cover the cost of the repairs and can cash settle the claim based on the quotation. 2.2 Is the insurer obliged to pay compensation for non-financial loss? Complainants suffered excessive stress during claim processing The complainants say he claim has been on-going since 2017 and there have been significant delays in the handling of their claim. The complainants say the delays have caused significant stress and inconvenience. The complainants noted experts from the insurer and its representatives attended at different inspections and were in contact to try and resolve the matter. The panel considers the inconvenience to the complainants, although also acknowledges the insurer‟s view that it made efforts to try and bring the matter to a resolution. The insurer concedes some deficiencies in the earlier handling of the claim, but for the most part its claims team responded to the complainants‟ requests in a timely manner, actioned concerns and made the required payments regarding variations as soon as possible. While the panel notes the insurer was entitled to spend time on obtaining expert reports and clarification, the matter has spanned over three years, and caused significant stress and inconvenience to the complainants. Determination | Case number: 724686 Page 6 of 14 Considering the claim processing, the length of time taken to resolve the complaint overall, and the stress on the complainants, the panel considers the insurer is to pay $2,000 in compensation for non-financial loss. Determination | Case number: 724686 Page 7 of 14 3 Supporting information 3.1 Relevant policy provisions Page. 16 Product Disclosure Statement: 6 Storm, snow or hail What we insure you for We insure you for loss or damage to the home caused by storm (including cyclone), snow or hail. By „storm‟ we mean a violent wind that may occur wit h thunder or heavy rain. What we do not insure you for We do not insure you for loss or damage caus ed by wind, rain, snow or hail entering the home unless it enters because of structural damage to the home that is directly caused by the storm, snow or hail. 7 Rain What we insure you for We insure you for loss or damage to the home caused by rain. Rain includes that part of the rainfall that is not absorbed by the soil but runs off as surface water. What we do not insure you for We do not insure you for loss or damage caus ed by rain seeping into or ent ering the home because of: • defects in the structure or design of the home • defects in building work done on the home • an opening made in the home so that it could be added to, renovated, repaired or modified • failing to properly maintain the home. Determination | Case number: 724686 Page 8 of 14 3.2 Relevant expert reports Record Key points Insurer’s Expert (A) Loss Adjuster Report 26 April 2017  The upstairs flooring finish is carpet stuck onto particleboard flooring. This presents in an aged but satisfactory condition from where we can see it under the home (under kitchen area). Under the bathroom cannot be seen from underneath as there is suspended ceiling in this bedroom.  There is a general hump which ins ured maint ains has appeared since the cyclone in the particleboard floor (due to pressure s from the cyclone). This hump is located directly outside the bathroom door in close proximity to the shower recess. Water from cyclone did not reach this area and carpet is still intact.  this is more likely in our view to be related to a leak from the shower recess or moisture over time from people walking out of the bathroom wet, soaking the carpet and being absorbed by the floor (due to its close proximity to the doorway) .  lifting the ca rpet in this area or exposing the ceiling underneath this area will show the tracking of moisture to this part of the floor from the bathroom. Insurer’s Expert (GT) Engineer Report June 2019  The roof structure was not inspected as part of our review.  Bul ging to main bedroom floor – the observed damage is located outside the first - floor bathroom. An approximate assessment of the falls in adjoining ens uite was made by observing the flow of a cup of water spilled onto the floor. The water did not flow to the floor waste as would be expected to occur. This lack of fall in the bathroom floor provides a mechanism for any wat er that penet rates the waterproofing to spread to other areas of the floor resulting in damage similar to that observed.  We do not believe t hat this damage can be plausibly be attributed to the cyclone event and is instead due to long term water damage which has resulted from a failure in the bathroom‟s waterproof membrane  We are of the opinion that the issues are relat ed to age or workmanship and not the cyclone event.  We do not believe that damage to the interior of the residence can be attributed to the cyclone … T he required conditions did not exist inside the residence. Insurer’s Expert (GT) Engineer Report 24 October 2017  We suggest that the images which claim to show wat er damage are reasonably consistent with what could be expected to have occurred during the event; i.e. relatively small amounts of wind driven water entering through gaps in cladding or flashings. We are n ot convinced that the images show evidence of water ingress in sufficient volume to have caused the damage to the floor below the manhole; nor do we find it likely that this could have occurred without resulting in staining to the ceiling or Determination | Case number: 724686 Page 9 of 14 Record Key points damaging ceili ng mounted fixtures.  Generally we have observed that when wat er ent ers the ceiling in significant volumes it mixes with dust (or other residue); this solution then travels through the ceiling resulting in clear staining to the internal finishes. In some b uildings the ceiling is clean enough for this not to cause such obvious stains, but the ingress of water is still clearly apparent. We do not believe that any such observations have been made here. Insurer’s Expert (GT) Engineer Report 14 November 2017  Roof interior - Evidence of water ingress was observed in several locations throughout the roof… we suspect this deterioration is due to moisture ingress causing corrosion over a long period of time.  Water staining was observed to the top surface of the plaster ceiling lining in several locations.... We suspect that water is able to enter at the ridge and drain ont o the ceiling at locations where the sarking has deteriorated; we do not attribut e this d eterioration to the cyclone.  There was no sign of any significant mould inside the roof cavity. Although we have reported evidenc e of water ingress (water staining), there was no evidence that plaster had became saturated as a result; this indicates that w ater did not enter in large volumes.  Bathroom floor hump ; there was some discoloration but no evidence of actual moisture damage.  The floor framing was inspected from inside the garage … based on obs ervations and a review of the structural documentation w e believe there are issues with the floor framing which significantly contribute to the hump observed.  it is the opinion of CCFNQ that water entering the ceiling cavity during the cyclone has drained onto the timber particle board floor and r es ulted in the observed damage. Although it is not stated outright in the report, this conclusion depends on three conditions holding true, namely : - That water did enter the roof cavity, - That water which entered the cavity drained through the manhole causing the flo or below to become wet, and - That the type of particle board used in the floor is susceptible to water damage as would occur from an isolated single event.  we believe that water likely did enter the roof during the cyclone event however we found no eviden ce to suggest that this was in large quantities  Structatlor may be exposed to the weather tor up to 3 months . … it is extremely unlikely that the floor would be damaged by water in such a short period of time as has been reported, regardless of whether it was exposed to water as claimed.  it is possible that a breakdown of the waterproofing may allow moisture to penet rate the floor space and over a long period of time this could result in damage. Although we still believe this is possible (likely be a contr ibuting factor rather than the primary issue), we have subsequently had the opportunity to review the Council building file and have noted a significant defect with the floor framing and believe this is more likely to be the primary cause of the bulging. Determination | Case number: 724686 Page 10 of 14 Record Key points Insurer’s Expert (FCE) Engineer Report 3 March 2020  Except for flooring in extremely close proximity to external sliding door openings, water exposure related discolouration of the particleboard flooring generally did not appear to be significantly concen trated or worse inside of external window and door openings where maximum wind driven rainwater ingress during the claimed cyclone event could be expected, nor did the discolouration appear concentrated under or around the central ridge of the roof. Instea d, fairly constant water exposure related discoloration of the flooring was observed right across the residence. The consistency of wat er exposure related discolouration suggests the discoloration of the flooring to this residence is predominately related to past weather exposure during the original construction of the residence; Internal Particleboard Flooring - Swelling  At sliding door locations, some extremely localised curvat ure, stepping and water exposure related edge swell of the particleboard flooring was observed to have occurred. We believe this has been caused by the following:  Drying shrinkage in the early life of the residence and resulting settling of the originally green or unseasoned structural timber floor framing members. We believe t his has caused floor sheeting to locally curl up (bed 1 & lounge) and vertically step up to the small slithers of infill flooring (meals & bed 2) where the edge of the floor sheeting is additionally supported by the external clay block walls across the sli ding door openings;  By the particleboard flooring around the sliding door openings having saw cut edges that will have exposed bare particleboard timber fibres without the normal external water - resistant coating;  Exposure to rain during the original constr uction of the residence;  The expected occurrenc e of cyclone Debbie related wind driven rainwater ingress through the sliding doors  The local floor sheet edge lift and swell condition at the four sliding door openings can be suitably resolved by replacing t he tiny slithers of particleboard flooring inside the sliding doors to the rear meals and bedroom 2 areas and by locally sanding the floor edges around the four upper level sliding door open in gs to bed 1, lounge, meals and bed 2. Internal Particleboard Fl ooring – Gapping  the gaps observed bet ween the floor sheets and the resulting uneven movement of the unsupported floor sheet edges under concentrated offset loading is a very long - term building issue which has not been directly caused by or exacerbated by the cyclone Debbie event.  We advise this issue could be readily resolved on site and without needing to replace the flooring, by the installation of solid timber blocking bet ween floor joists beneath the unsupported edges of the floor sheets. Existing floor framing  This is a latent defect in the original construction of the residence that has not been in any way influenced by the cyclone Debbie event. In our opinion the undersized floor joists Determination | Case number: 724686 Page 11 of 14 Record Key points combined with the resulting abrupt change in floor deflection between the single spanning floor joists is the cause of a claimed “hump” in the bedroom 1 floor just outside the bathroom. This is again a latent building defect issue associated with the original construction of the residence and will not have been caused or exacerbated by the cyclone Debbie event.  How could water from the cyclone have possibly reached all areas in the entire upper floor? Given the glazing of the external doors and windows did not fail during the cyclone Debbie event and only modest and very localised roof water ingress occurred, it is not plausible that wind driven rain reached across and exposed the entire upper floor to rainwater.  Why has a once off short - term water exposure damaged floors at all? As the flooring generally remained in a fair condition, it is our opinion that the flooring would have generally remained protected by its normal water - resistant coating and therefore would not be damaged from a single additional exposure to rainwater. However, where the edges of t he floor sheets have been cut to fit into and around the external sliding door openings, the cut edges will have exposed raw timber that is no longer protected by the original water resistant coating applied over the floor sheeting. At these particular loc ations only, we believe it is possible that the flooring would likely be damaged from short term exposure to water, such as that which is claimed to have occurred during the cyclone Debbie event.  Is there genuine event related cyclone damage to the Struct aflor particleboard flooring inside the windows/sliding doors? Yes. We believe there is highly localised water damage inside the sliding door openings where the flooring has been cut and fitted into and around these door openings. This condition does not e xtend to window areas where the flooring has not been cut in a similar fashion and is offset from the external walls.  Is there any presence of long - term seepage through doors generally due to maintenance issue s as di stingui shed from cyclone damage? No. Al l external sliding doors are well covered by the roofed patio areas and therefore would not typically experience exposure to rainwater other than during extreme storm events such as cyclone Debbie.  Is there presence of any actual structural damage to the Structaflor given their built - in moisture re si stance properties? No. We believe the particleboard flooring remains structurally sound and any swelling of the particleboard sheet edges remains within an allowable range that can be readily addressed by simpl e floor sanding.  Is it possible to repair the damaged areas only? Yes. We believe the event related water exposure to the particleboard Determination | Case number: 724686 Page 12 of 14 Record Key points flooring can be readily resolved by replacing the small slithers of flooring installed inside of the sliding door openi ngs to the rear meals and bedroom 2 areas and by sanding the floor to reduc e the sheet edge lift and swell. Insurer’s Expert Engineer Email 19 July 2019  I see not hing in [GWG] reports that suggests I should review our original conclusions.  [GWG] have made no reference to any research they may have preformed to support their assessment on the need to replace the existing floor sheeting - staining does not necessarily mean structural impairment nor continuing degradation - there has been no cl ear definition on the extent of sheeting that has been "damaged" and thus recommended for replacement.  [GWG] have made several statement's suggesting that certain damage is relat ed Cyclone damage (such as the bulging wall sheeting) without providing any m echanism to explain the connection.  [GWG] appear to have glossed over the inadequate roof sheeting fixings by calling them "unconventional".  [GWG] discussions with Mr H from the Cyclone Testing Station with respect to sheeting side lap distortion appears to be not entirely consistent with our own discussions with Mr Henderson and sheeting manufacturers on this matter, particularly with reference to water penetration. Complainant ’ s Expert (GG) Engineer Report 23 January 201 8  Wind entering the roof cavity was evident due to damage to sarking, this appears to be approximat ely in the position where water ingress was observed in the living room ceiling area.  extent of damage to the roof is limited to roof sheeting, barge flashings and the front guttering.  The roof of this residenc e does show effects from Tropical Cyclone Debbie with regards to impact damage and scratching from flying debris, at least 12 roof sheets show damage from impact and scratching.  During the inspection it w as noted that some connections of the timber floor framing to the bearer and pole plate were deficient and would have allowed additional movement during Tropical Cyclone Debbie than would normally occur.  Wind driven rain, was the cause of water ingress int o the residence, through side lap buckling and overlap of the verandah and main roof sheeting. Windows also allowed wat er ingress  The displacement of the floor and wall adjacent the stairs needs further investigation to determine the cause of the damage. W e agree wit h [GT] that the extent of water ingress in these areas to cause this damage does not appear evident.  This office did conduct an in - roof and on - roof inspection. The hardwood roof framing and hold down did not appear compromised from the in - roo f inspection. The on - roof inspection did show damaged sheets from impact and scratching from windblown objects during Tropical Cyclone Determination | Case number: 724686 Page 13 of 14 Record Key points Debbie. The guttering along the front of the residence was missing Complainant ’ s Expert (GG) Engineer Report 8 August 2018  The out of level of the stairs from the lower level to the upper level and the bowing of the wall, does not appear to be from raking of the building due to no evidenc e of horizontal cracking in the external masonry walls. Internal linings would need t o be removed to determine if damage was pre - existing or from structural members being compromised during Tropical Cyclone Debbie  The probability of [stairs, bulging wall, bulging bedroom floor, cracking to cornices and separation of cabinetry] damage resul ting from the cyclone is highly likely and could be considered consistent with the effects of internal increased pressures experienc ed in a cyclonic event. Complainant ’ s Expert (G G) Engineer Report 15 April 2019  An inspection of the upper level flooring was undertaken once the floor covering was removed. Water staining in the particle board floor is evident adjacent windows and sliding doors. Swelling at joints of the particle board and bowing in the flooring was evident.  An inspection of wall framing at the rear of the shower was undertaken to determine if any water ingress damage resulted from a leaking shower. No evidence of leaks around the shower area was detected  The extent of damage to the particle board flooring is mainly adjacent windows and slid ing doors as this was the access point of water ingress during Tropical Cyclone Debbie. Carpets being saturated has caused damage to flooring adjacent the access points nominated above.  High wind forces and heavy rain during Tropical Cyclone Debbie resulte d in water ingress through seals and drainage tracks in the windows and external sliding doors.  This office is under the opinion that in order to certify the flooring and floor framing the particle board flooring would need to be replaced.  Recommended pr oposed works: - Remove particle board flooring on the upper level and replace; - Inspect external masonry at the top corners on the western gable during roof and soffit remedial works. Complainant ’ s Expert (GG) Engineers Report 24 September 2019  Re .[GWG] have made no referenc e to any research they have performed to support their assessment on the need to replace the existing floor sheeting” The staining is an indic ation where ingress of water did occur. Staining was evident adjacent most windows and extern al glass sliding doors. The photos and attachments in Appendix B and C indicate it did necessarily mean structural impairment occurred.  Re “ There has been no clear definition on the extent of sheeting Determination | Case number: 724686 Page 14 of 14 Record Key points that has been “damaged and thus recommended for replac ement .” Removal of damaged sheets at these locations and where saturated carpet existed, covered the majority of the upper floor level. It would be expected to be more economical (a builder would need to confirm) too remove all sheets and replace, than try ing to save part sheets in different areas in which solid blocking would have to be installed between the existing joists at joint locations.  [GT] again states… that the internal ceiling and wall sheeting damage may appear similar in nature to that of the external areas which he agrees is cyclone relat ed.  In our opinion no evidence has been submitted by [GT], only his opinion, whic h in some cases contradicts his opinion, to dispute the findings of our report. We have attached literature in the appendix of this response to verify our conclusions.

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.