Home / QBE / Determination 724526
Determination 724526
Home retaining wall collapse claim declined
Summary
The complainant's claim for collapse of a front timber retaining wall during a February 2020 storm was declined by the insurer. AFCA found the wall had deteriorated over several years before the storm and ruled the insurer could rely on the previous unrepaired damage exclusion.
The storm exacerbated pre-existing forward rotation and defective construction, so the policy exclusions for gradual deterioration and previous unrepaired damage apply.
Issues
- Claim denial primary · not upheld“The insurer is entitled to decline the claim as the policy excludes cover for previous damage which has not been repaired.”
Subjects and remedies
home or building damageno remedy
Related
Text of the determination
Determination
Case number 724526
Financial firm QBE Insurance (Australia) Limited
Determination | Case number: 724526 Page 2 of 8
Case number: 724526 11 November 2020
1 Determination overview
1.1 Complaint
The complainant holds a building and contents insurance policy (policy) with the
financial firm (insurer) covering his home (insured property). On 14 February 2020,
the complainant lodged a claim for damage to the front timber retaining wall, whi ch
partially collapsed during a storm on or about 9 February 2020.
The insurer has declined the claim and says the damage is the result of
circumstances clearly excluded from cover, which the complainant rejects and is
seeking a review by AFCA.
1.2 Issues and key findings
What does the policy cover?
The policy covers the insured building against the listed insured events as well as
accident damage subject to the conditions, limitations and exclusion provisions
specified in the product disclosure statement (PDS).
The policy excludes from cover loss or damage that is directly or indirectly caused by:
erosion, rust, corrosion, gradual deterioration, depreciation, wear or tear
a defect in an item, structural defects, faulty or poor workmanship or design
previous damage that has not been repaired.
Is the insurer entitled to decline the claim in line with the policy?
The available information shows, on the balance of probabilities, the damage to the
front retaining wall (wall) had been developing gradually over an e xtended period of
time. It was present before and remained unrepaired after the complainant purchased
the property in 2010, until its actual collapse in February 2020.
Accordingly, the insurer is entitled to decline the claim as the policy excludes cover for
previous damage which has not been repaired.
1.3 Determination
This determination is in favour of the insurer.
The damage to the wall claimed is the result of circumstances clearly excluded from
cover under the policy. The insurer is entitled to decline the claim.
Determination | Case number: 724526 Page 3 of 8
2 Reasons for determination
I have decided this case based on what is fair in all the circumstances, having regard
to the relevant legal principles, good industry practice, industry codes of practice and
previous relevant decisions of AFCA or predecessor schemes.
I have considered all material submitted by the parties both, before and after the
preliminary assessment. I am satisfied the documentation I have relied on has been
provided to both parties.
2.1 What does the policy cover?
The policy includes the optional cover for accidental damage to the building
The policy covers the insured building against loss or damage caused by one of more
of the listed insured events specified in the PDS. The complainant, in addition to this
cover, also purchased the optional cover for accidental damage to the insured
building.
Accidental damage, as explained in the PDS, covers the insured building against
unintended and unexpected loss or damage. There is no dispute between the parties
or an assertion that the damage was caused intentionally or was reasonably expected
by the complainant.
Therefore, I am satisfied the damage to the wall is accidental and as such the
complainant has been successful in establishing a valid claim under the policy.
Cover under the policy is subject to the policy limitations and exclusions
Cover under the policy, even when a valid claim has been established, remains
subject to the conditions, limitations and exclusions specified in the PDS. There is no
dispute the insurer provided, and the complainant received the relevant policy
documentation including the certificate of insurance (COI) and PDS.
Therefore, I am satisfied the insurer is entitled to rely on the policy provisions to
assess its liability under the complainant’s claim.
The insurer has sought to rely on the below policy exclusions to decline the claim.
The policy excludes from cover loss or damage that is directly or indirectly caused by:
erosion, rust, corrosion, gradual deterioration, depreciation, wear or tear
a defect in an item, structural defects, faulty or poor workmanship or design
previous damage that has not been repaired.
The insurer is of the opinion the damage to the wall is due to defective and
inadequate construction for its purpose, the damage has occurred gradually over a
Determination | Case number: 724526 Page 4 of 8
period of time and, on balance, has existed for several years. On this basis, it is of the
view, the storm event in February 2020, is not the proximate cause for the damage.
2.2 Is the insurer entitled to decline the claim?
The available info rmation supports the insurer’s decision to decline the claim
In determining the proximate or effective cause of the damage, it is necessary to
consider the facts of the situation alongside the terms of the relevant policy. It is a
well-established principle of insurance law that the proximate cause of the loss is not
the first, or the last, or the sole cause of the loss but the effective or dominant or
effective of the loss.
The insurer relies on the information and opinions provided by the consultants ‘K’ and
‘E’ (Structural engineers) it appointed to the claim in order to investigate the cause
and extent of damage to the wall.
The policy excludes previous damage that has not been repaired
The insurer says the damage to the wall is due to defective and inadequate
construction for its purpose, the damage has occurred gradually over a period of time
and, on balance, has existed for several years without being repaired.
On this basis, it is of the view, the storm event in February 2020, is not the proximate
cause for the damage. The policy excludes from cover damage due to gradual
deterioration and existing damage which has not been repaired.
The insurer has provided very helpful photographic historical data in the form of aerial
photos as well as images from google street maps. This information, on balance,
clearly shows that the wall since as early as 2010, had begun showing signs of
irregular alignment and forward rotation (leaning).
E considered the wall collapse may have coincided with the storm, but the storm was
not responsible for its collapse. It was experiencing forward rotation for several years.
I note E’s assertions that the walls construction was defective and not fit for purpose.
However, as correctly pointed out by the complainant’s appointed consultant ‘AC’, E
has not provided reasonably compelling supporting information in this regard, such as
the relevant Australian Building standards in place at the time of the walls
construction.
K noted the damage was present for up to 3 years given the complainant advised the
wall had a slight lean when the property was purchased in 2016. K considered the
cause for the damage is long term movement.
The information establishes, on balance, that these issues of alignment and forward
rotation continued to gradually worsen and ultimately led to the walls collapse during
the storm in February 2020. It is not in dispute, that the wall presented with this
Determination | Case number: 724526 Page 5 of 8
forward rotation and irregular alignment and of which the complainant was aware,
when he purchased the property in or around October 2016.
I have not been provided with any evidence which would shows the complainant
undertook or arranged any repairs to rectify this issue with the wall.
Having considered the information from AC, it is clear this information is not based on
a site visit or physical assessment of the wall. Further, there is no comment or
evidence refuting the fact the wall presented with these aforementioned issues for
many years prior to its ultimate collapse.
Therefore, without information to the contrary, and considering the evidence as a
whole, I am satisfied it has been shown that the wall was gradually deteriorating and
losing alignment due to forward rotation over several years. Also, that in the absence
of information to the contrary, this is the proximate cause for its collapse.
I accept its actual collapse occurred during a storm event, however, I am not
convinced the storm was the proximate cause for its collapse, rather, it only
exacerbated the already damaged and weakened state of the wall.
Accordingly, I determine it is fair that the insurer be allowed to maintain its decision to
decline the claim on the basis the collapse of the wall is the result of previous damage
which had remained unrepaired over previous years.
Determination | Case number: 724526 Page 6 of 8
3 Supporting information
3.1 AFCA approach to this complaint
This complaint has been determined based on what is fair in all the circumstances,
having regard to the relevant law, good industry practice, codes of practice and
previous decisions of AFCA or its predecessor schemes (which are not binding).
A full exchange of the relevant information has taken place between the respective
parties. Each party has had the opportunity of addressing any issues raised.
All the provided material has been reviewed and considered. The parties have raised
numerous issues in their submissions to AFCA. However, commentary in this
determination is restricted only to those issues considered relevant to the outcome.
3.2 Consultants’ relevant evidence
Record Key points
K’ s Site Inspection Report attended the insured property on 9 March 2020
noted the timber retaining wall to the front of the property had
completely disengaged
in K’s opinion the damage was present for up to 3 years given the
complainant advised the wall had a slight lean when the property
was purchased in 2016
the cause f or the damage is long term movement
K recommended an engineer be appointed for furt her investigation
E Structural Engineer and
Builder’s Report
23 March 2020
this is a joint structural engineering and builders report
attended the insured property on 20 March 2020
complainant advised he had owned the property since October
2016
the wall has existed in some form since January 2010
the home fac es north west and the site slopes from south east to
north west
complainant advised that the alignment of the wall was previously
deformed, but it actually collapsed in the storm on 9 February
2020
no indication of drainage provisions immediately behind the wall
test excavations at the base of two vertical posts expose d
embedment deficiencies
west corner showed no embedment into undisturbed ground
aerial photos show a history of forward rotation of the wall before
pre - dating the storm event
the walls construction for this task, is not only defective above
ground, but totally inadequate in generating adequate embedment
anchorage below ground
E concludes that the wall is under designed and poorly
constructed
its collapse may have coincided with the storm, but the storm was
Determination | Case number: 724526 Page 7 of 8
Record Key points
not responsible for its collapse. It was experie ncing forward
rotation for several years.
AC Engineer’s Memorandum
(Report)
22 July 2020
AC provides that this is a preliminary structural engineering review
of the findings outlined in investigation reports pertaining to the
front boundary retaining wall collapse
there are vague referenc es made in E’s reports regarding
recommendations for a log retaining wall arrangement which come
from a timber supplier, with no reference to the Australian
standards
this leads to the question as to whet her any engine ering analysis
or design review has been conducted in accordance with the
Australian standards
the wall was able to retain the lateral portion of the load (about
40%) for 14 years, so this shows it possessed some capacity as a
retaining wall as opposed to E’s opinion that it had ear zero
resistance capacity
recommends that a furt her review of the collapse should occur
with some form of analysis of the loading imposed on the wall, as
well as, the walls capacity to retain loads
E’ s re sponse to the
complainan t 3 June 2020
and Supplementary Report 7
September 2020
Google street map images show the rotated/separated condition of
the wall in May 2019
Aerial photos from 2010, even before the complainant bought the
policy, show the irregular alignment of the wall, indicating an
already degraded condition
pipe shown by the complainant is most likely part of the
stormwat er drainage from the house roof to street outlet
deficiencies and failures of the wall were clearly evident
the pre - existing forward rotation of the w all is indicative of the
inability of the walls design and construction and was not fit for
purpose
‘some capacity’ to retain was clearly not sufficient.
3.3 Relevant policy wording
BUIDLINGS AND CONTENTS COVER EXCLUSIONS
We will not pay for any loss or damage caused directly by indirectly by:
…
erosion, rust, corrosion, gradual deterioration, depreciation, wear or tear
Determination | Case number: 724526 Page 8 of 8
a defect in an item, structural defects, faulty or poor workmanship or
design
previous damage that has not been repaired.