Home / QBE / Determination 723801
Determination 723801
Storm damage to roof flashings claim declined
Summary
The landlord claimed for storm damage to rental property flashings, which the insurer declined as poorly installed and deteriorated. AFCA found the storm was not the dominant cause of the damage, so the insurer was entitled to decline.
The complainant must establish a valid claim on the balance of probabilities, and equally plausible pre-existing wear and tear could not be ruled out.
Issues
- Claim denial primary · not upheld“The available information does not establish that the property's flashings were probably damaged by storm, so no valid claim is established.”
Subjects and remedies
home or building damageno remedy
Related
Text of the determination
Determination
Case number 723801
Financial firm QBE Insurance (Australia) Limited
Determination | Case number: 723801 Page 2 of 6
Case number: 723801 17 November 2020
1 Determination overview
1.1 Complaint
The complainant’s tenanted property was insured with the financial firm (insurer)
under a landlord policy. He claimed for damage to the property ’s flashings , saying
they were damaged in a storm on 18 February 2020.
The insurer declined the claim, saying the flashings were poorly installed and no
resultant damage arose from the storm. It also says any resultant damage would not
be covered in any event as the policy excludes damage caused by:
water entering a building due to inadequate gutter design or unrepaired damage
wear and tear, and deterioration of the property’s flashing .
1.1 Issue and key findings
Is the complainant entitled to indemnity for the claim?
The complainant is not entitled to indemnity. The available information does not
establish that the property ’s flashings were probably damaged by storm. Accordingly,
the complainant has not established a valid claim for the damaged flashings.
1.2 Determination
This determination is in favour of the insurer.
The insurer is entitled to decli ne the complainant’s claim and is not required to take
any further action in relation to the claim or complaint.
Determination | Case number: 723801 Page 3 of 6
2 Reasons for determination
2.1 Is the complainant entitled to indemnity for the claim?
I have decided this case based on what is fair in all the circumstances, having regard
to the relevant legal principles, good industry practice, industry codes of practice and
previous relevant decisions of AFCA or predecessor schemes.
I have considered all material submitted by the parties, both before and after the
preliminary assessment. I am satisfied the documentation I have relied on has been
provided to both parties.
The preliminary assessment concluded that the insurer was not required to meet the
claim because the property’s damage was caused by excluded events.
The preliminary assessment was accepted by the insurer but was rejected by the
complainant. He maintains his property was damaged by storm because:
it would have experienced water entry earlier if the flashings were poorly installed
photos show the flashings were bent and damaged due to storm activity.
Complainant must prove a valid claim
The complainant must establish, on the balance of probabilities, he suffered a loss
caused by an event to which the policy responds. This is known as a prima facie or
valid claim. Once established, the onus shifts to the insurer to prove, on balance, an
exclusion applies if it seeks to deny or limit its liability for the loss.
The relevant policy extracts are set out in section 3.1 of this determination.
Complainant says flashings were damaged by storm
The parties accept the complainant’s property was subject to a storm on or around 18
February 2020, resulting in water overflowing into the carport area. The overflowing
water did not however cause damage to the property.
The issue is whether the storm damaged the property’s flashings, which then caused
water to overflow into the carport area.
The complainant says it did and this was why water had entered the carport. He
refers to the bent condition of the flashings on the roof and the fact he has not had
any issue with water entry since owning the property in 2011 until now.
Insurer says flashings were poorly designed and installed and had deteriorated
The insurer disputes that the property was damaged by storm, saying:
the flashings were poorly installed and had deteriorated
the complainant was aware of its inadequacy and that they were already leaking
but failed to rectify it.
Determination | Case number: 723801 Page 4 of 6
The insurer relies on the report of its appointed builder (AR). This report said the
p roperty’s tenant , who had been living there for eight years, had reported that:
water would overflow the gutters at the rear of the property and at the side of the
carport during heavy rainfall events
this began in the last 3-6 months and only happens during heavy rains
the complainant had carried out some work to improve the property’s stormwater
system at these areas, but the gutters still overflow during heavy rainfall.
In the same report, AR also said there was no damage to the roof and explained the
cause of water entry as follows:
The gutter design of the side carport area is considered poor, the gutter is not
sufficient to disperse the large amount of water that is collected on the
garage/carport roof. The insured has installed a rain head sump to the downpipe
in the garage area, however this has not improved the overflow issue. We have
also noted non-compliant and poorly installed flashings where the carport roof
joins the fascia of the main dwelling.
It appears that if the eaves gutters of the main dwelling on the carport side
overflow, water will then enter the carport/garage area.
… It is our opinion that the garage roof and gutter design needs to be improved to
allow excess rainwater to be collected and dispersed effectively.
The flashings installed where the carport roof meets the main dwelling fascia
require replacement.
Having said that, AR also recognised that:
It should be noted that it’s possible there is a blockage in the stormwater system
downstream. This would need to be investigated further and possible CCTV
inspection carried out. We have not arranged any further investigation as there
has been no resultant damage to the property.
Evidence suggests February 2020 storm could damage flashings
Photos provided by the parties show that th e roof on the property’s main dwelling and
carport generally appear to be in good and serviceable condition, but for the flashings
installed at the point where the property’s c arport meets the main dwelling.
The photos show the flashings have lifted off or disengaged from the roof and building
structure at certain places. On balance, this appears to be the likely cause of the
water entry into the carport as water can now get under or behind the flashings.
Bureau of Meteorology records for the property’s l ocation show the area likely
experienced winds of up to 80km/h on around 5:34pm 18 February 2020, and some
Determination | Case number: 723801 Page 5 of 6
47.8mm worth of rainfall overnight. I note that these windspeeds and rainfall were the
highest for the month of February 2020.
According to the Beaufort wind scale, winds between 75km/h to 88km/h are
considered a ‘strong gale’ and can cause ‘slight structural damage’.
But evidence also suggests flashings were damaged before February 2020
While this can support that the relevant flashings were damaged during the February
2020 storm , it does not explain the tenant’s report that water had already began
overflowing into the carport area during heavy rains some 3-6 months earlier.
On balance, this suggests that the flashings likely became damaged earlier and the
storm on 18 February 2020 merely exacerbated the issue.
Insufficient evidence flashings were damaged by storm
There is no information in the exchanged material to assist in determining if the first
incident of water entry was because:
the flashings were damaged by a storm then, or
the seals or fixings that attaches the flashings to the property’s roof or building
structure had already failed due to natural wear and tear or deterioration by then.
The evidence before me is that nine years have passed since the complainant owned
the property. It also appears he was aware of prior incidents of water entry in the last
three to six months, and there is also no information to suggest the roof and its
drainage systems were periodically inspected and maintained from the time he owned
it up to the first incident of water entry.
Considering these matters, I cannot reasonably rule out equally plausible possibilities:
natural wear and tear of the relevant flashings seals and fixings may have already
reached a point of failure some months before the February 2020 storm
the February 2020 storm merely exacerbated existing damage to the flashings,
rather than caused the damage.
Complainant has not established valid claim for damaged flashings
For these reasons, I am not satisfied that the 18 February 2020 storm (or any other
storm) was, on balance, the dominant cause of the claimed flashings damage.
This means the complainant has not successfully established a valid claim for the
flashings damage, and the insurer is entitled to decline the claim.
Determination | Case number: 723801 Page 6 of 6
3 Supporting information
3.1 Relevant policy wordings
Insured events
…
Insured
event
What we’ll cover We won’t cover
…
Storm, rain
or flood
Damage caused
by storm, rain or
flood
Damage caused by:
Water penetrating or entering
your building if it’s not
properly maintained and/or
existing damage hasn’t been
repaired
Water penetrating or entering
your building because of a
design fault, structural defect
or defective workmanship
…
General exclusions
…
What we won’t cover
If the incident arises from or is connected wit:
…
Wear and tear, depreciation, deterioration
…
Previous damage that hasn’t been repaired
3.2 Relevant link to access Beaufort Wind Scale
https://www.anbg.gov.au/jrc/kayak/beaufort.html