Home / Westpac / Determination 722888

Determination 722888

Claim for cracking and foundation movement denied as ground movement

FirmWestpac
Decided2021-04-27
ProductGeneral Insurance · Landlord
OutcomeFor the complainant in part
Amount awarded$5,000
Non-financial loss—
Amount claimed—
SourceAFCA PDF

Summary

The landlord's claim for foundation cracking, attributed to a leaking sewer pipe, was denied by the insurer. AFCA upheld the denial but ordered the insurer to contribute up to $5,000 towards the complainant's professional engineering costs.

The proximate cause was ground movement, which is excluded, but the complainant reasonably obtained engineering advice, so professional costs were reimbursable under AFCA Rule D.5.

Issues

Subjects and remedies

home or building damagepay compensation

Related

All Westpac determinations · Find similar determinations

Text of the determination

Determination Case number 722888 Financial firm Westpac General Insurance Limited Determination | Case number: 722888 Page 2 of 12 Case number: 722888 27 April 2021 1 Determination overview 1.1 Complaint The complainant held a Landlords policy with the Financial firm (insurer) and has lodged two claims with the financial firm (insurer) for cracking damage and foundation movement at her property. The first claim was lodged in 2013. The insurer denied this claim and says the complainant has not shown an insured event occurred. The second claim was lodged in 2015. A leak was detected however, the insurer said there was no resultant damage from the leak. The complainant withdrew the claim. The complainant contacted the insurer again in 2019 to report movement to the property. A new claim was not lodged, and the insurer says the claimed damage was not caused by an insured event and instead was caused by ground movement and shrinkage. The complainant disputes the claim denial and says a leaking sewer pipe under a step caused the damage. 1.2 Issues and key findings Has the complainant established a claim within the terms of the policy? No. The policy is a listed events policy. The available information indicates the damage was not caused by escape of liquid but caused by earth movement which is excluded from cover under the terms of the policy. Is the complainant entitled to compensation for professional costs? Yes. The insurer i s to contribute up to $5,000 of the complainants’ professional costs incurred as set out under section 2.2 of this determination. 1.3 Determination This determination is in favour of the insurer. The insurer is entitled to maintain its denial of the claim in accordance with the terms and conditions of the policy. The insurer is to contribute up to $5,000 to the complainant’s professional costs subject to the complainant providing the relevant receipts. Determination | Case number: 722888 Page 3 of 12 2 Reasons for determination 2.1 Has the complainant established a valid claim within the terms of the policy? Complainant has not established a claim within the terms of the policy. Complainant has onus to prove claim falls within terms of the policy. It is established insurance law that a complainant has the onus to prove, on the balance of probabilities, that is more likely than not, a claim that falls within the terms of the policy. This is commonly called a valid ( prima facie ) claim. The complainant’s policy provides cover for various listed events including loss or damage caused by an accidental escape of liquid from a fixed pipe during the period of insurance. The complainant says that the escape of liquid from a leaking pipe has caused the foundation movement and resultant cracking. Insurer says no insured event and exclusion applies to 2013 claim The policy was incepted in January 2013 and the first claim lodged on 1 August 2013 for cracking damage to the home. The insurer appointed an assessor (CL) and an engineer (MO). MO later changed their company name (to IM) however, for clarity the panel will refer to both names as MO. Neither CL n or MO identified any leaks at the complainant’s property in 2013. The complainant was also unable to identify a leak at that time. MO considered the foundation movement to be most likely due to moisture fluctuations in the soil resulting from seasonal and environmental factors. MO also noted signs that the property had moved throughout its life. As a result, the i nsurer denied the claim and said there was no insured event (no escape of liquid). It also says the cracking damage was caused by ground/foundation movement which is specifically excluded by the policy. 2015 claim was withdrawn for no resulting damage The second claim was lodged on 9 April 2015 following water leaking/rushing from under the house. The insurer appointed CL and a plumber (OR) who completed a leak detection test. OR found the sewer had blocked causing overflow from an inspection point under the house. The claim was withdrawn on the basis there was no resultant damage from the leak. Determination | Case number: 722888 Page 4 of 12 Complainant reopened claim in 2019 In 2019 the complainant contacted the insurer seeking to reopen the 2015 claim saying the damage had worsened. During the subsequent investigation the complainant identified a leaking pipe under the rear porch. The complainant says the porch was installed prior to her purchasing the property. Expert reports differ as to cause of damage The insurer obtained engineering reports from MO dated 14 November 2019 and LO dated 12 March 2020, 7 August 2020 and 22 October 2020. The complainant provided reports from MA dated 19 June 2020, 29 July 2020 and 9 October 2020, that disagree with the findings of MO and LO. A summary of the reports is contained in section 3.2 of this determination. MO considered there were several factors contributing to the damage including: the highly reactive soil being influenced by tree roots, seasonal changes, land redevelopment to the north, possible leaks from sewer and water from a do wn pipe at the SW corner. MO concluded that some influence from the sewer may have been seen, but given the long-term movement and the history, the degree, if any could not be established. LO says the pattern of footing movement is not consistent with a localised increase in moisture content from the reported sewer overflow. LO considered the cause of damage was not sewer overflow but long-term moisture content variation, inadequate foundation depth and other construction issues. MA considered the escape of water from the sewer was the main cause of the soil swell leading to the cracking damage. Following a pressure test on 8 October 2020, MA says different plumbers have now confirmed numerous leaks in the sewer pipes on the Southern side. MA believes this has caused heave in the foundations and the resulting damage. In response to this LO says the latest tests are only indicative of escape of liquid under pressure which does not simulate normal flow conditions. LO maintains the position that the amount of water from the leaking sewer would be minimal as flow would not be under pressure and only when occasionally full. Given soil tests conducted at the same vicinity were dry and the report does not reveal any breaks LO considers any water pipe leaks would be insufficient to cause such significant wetting and movement. The insurer says both MO and LO confirm an escape of liquid was not the cause of the damage noting that while the leaking sewer cannot be ruled out as a contributing factor the property was extensively damaged prior to the sewer leak. Determination | Case number: 722888 Page 5 of 12 Proximate cause of damage is ground movement The panel is not satisfied the information exchanged is sufficient to establish that most likely the damage has been caused by the insured event escape of liquid. Having carefully considered all relevant information, the panel is satisfied, that most likely, the proximate cause of the foundation movement is general ground/earth movement caused by multiple factors including seasonal moisture changes and environmental changes. The floor level survey taken in September 2013 shows the foundations were significantly out of level. The floor level survey taken in November 2019 shows significant change in the floor level since 2013. The property had significant cracking damage in 2013 as shown in the photographs taken at the time. Assuming the foundations were constructed approximately level the propert y’s foundations had also undergone significant movement prior to September 2013 when the initial floor level survey was done. The surveys show the house has risen around 20mm in the southwest near the sewer leak however, an extension added to the house only a few metres to the west of the leak has dropped more than 70mm compared to its 2013 level. Overall the house has undergone widespread movement and a significant change in level between 2013 and 2019. There was no leak detected in 2013 and no information to show any escape of liquid prior to the 2015 claim lodgement. Although MA considers the events in 2015 and 2018 have caused heave as evident in the movement of the foundations he does not appear to have considered prior movement. MA has not provided an explanation of what caused the foundation movement prior to the sewer overflow and to what extent this has, or has not, contributed to the current damage. The panel is persuaded by the reports from MO and LO over the reports provided by MA. The reports prepared by LO are very extensive and supported by reasoning. LO does not dispute that the sewer overflowed in 2015 and 2018. However, in summary, his conclusion is that whilst these events may have contributed to damage, they were not the proximate cause. In considering the latest testing LO has acknowledged the possibility of a new and formerly undetected and undisclosed defect in the sewer line. LO considered that the extent and accuracy of the plumbing testing is not sufficient to provide new evidence to alter its view LO recommended more thorough testing of the line is necessary to determine the nature or existence of a defect. This should involve the commission of an independent plumber appointed by the insurer with sufficient expertise to CCTV the line. LO Determination | Case number: 722888 Page 6 of 12 considered this is critical given the initial plumbing investigation undertaken by in October 2019 identified no cracks in the sewer line. LO considered that the nature of the potential defect will be paramount in determining if an escape of water is the cause of footing movement and damage. Insurer is entitled to refuse payment of the claim The available information is not sufficient to establish on the balance of probabilities that the foundation movement was caused by the escape of liquid. It is not sufficient to establish a valid claim within the terms of the policy. Further, t he policy excludes loss or damage caused by ‘settling, expansion, shrinkage or any earth movement other than earthquake’. The panel is satisfied the proximate cause of the damage and foundation movement is general ground/earth movement. The claim does not fall within the terms of the policy. Fair that insurer arranges CCTV inspection of sewer as recommended by LO The panel acknowledges the latest reports and pressure testing indicate a possible previously undetected leak. The panel considered it fair that the insurer arranges an independent plumber to conduct a CCTV inspection of the line to determine if there are any breaks. The complainant has advised that due to the continued deterioration the property was no longer suitable for tenants and has been demolished. In the circumstances there is no point in the insurer arranging a further detection test. 2.2 Is the complainant entitled compensation for professional costs? Complainant is entitled to reimbursement of professional costs Paragraph D.5 of the AFCA Rules provides that we may determine an insurer should contribute up to $5,000 towards a complainant’s professional costs in pursuing a complaint. AFCA aims to provide a dispute resolution process which is accessible to complainants, without the need for professional advisors. Accordingly, professional costs will only be reimbursed where external advice is reasonably required, given the nature of the dispute. Given the extensive nature of the damage the panel accepts it was reasonable for the complainant to obtain independent engineering advice from MA. Further as indicated by LO the latest pressure testing arranged by the complainant has identified a possible leak identified which has resulted in a recommendation for further testing. Although the panel has not been persuaded by MA’s findings, the reports have assisted in reaching this determination. The Panel considers it fair in the circumstances that the insurer contributes a maximum of $5,000 to the cost incurred by the complainant in obtaining the engineering reports from MA and the latest leak Determination | Case number: 722888 Page 7 of 12 detection report. Payment is subject to the complainant providing the relevant invoices. Complainant is not entitled to compensation for non-financial loss Under rule D3.3 AFCA may also award compensation for non-financial loss (capped at $5,000) where a complainant suffers an unusual degree of physical inconvenience or time taken to resolve a situation. AFCA looks at what is reasonable and fair in all the circumstances. In considering what is fair in all the circumstances, it is appropriate to factor the overall claims experience rather than focusing on specific individual events. The complainant says the insurer has mishandled the claim and misled her to believe she would be covered under the policy. Further she believes the insurer failed to properly investigate the claim and the insurer ’ s conduct led her to remain insured with the insurer when it had no intention of accepting her claim. There is no indication that the complainant was misled. In 2013 the insurer obtained an engineering report and based its decision on that report. That was not unreasonable. In 2015 it obtained reports from its loss adjuster and a plumber into the escape of liquid. It identified and confirmed the complainant ’ s claim relating to the overflow of the sewer. No damage was detected to the home and at that time the claim was not pursued. The latest claim was lodged in July 2019. As the complainant was overseas it was not possible for the insurer to inspect the property until October 2019. Engineering reports and a plumber report were obtained. There is no indication the insurer misrepresented its position on the claim or unduly delayed any assessment. The claim was denied in May 2020 after a further engineering report was obtained. The panel appreciates the complainant has been under considerable stress because of the damage to the property. The complainant has had the worry and inconvenience of the cracking to the house getting worse over time as well as the i nconvenience of a claim denial. However, the panel considers the insurer dealt with the claims in 2013, 2015 and more recently fairly and consistently with the terms of the policy. It has appointed appropriate experts, reviewed information provided by the complainant and responded reasonably to that information. The panel is not satisfied the complainant is entitled to compensation for non-financial loss. Determination | Case number: 722888 Page 8 of 12 3 Supporting information 3.1 Our approach to this complaint Complaint has been expedited to determination by a panel This complaint has been considered under AFCA’s legacy jurisdiction. Due to the nature of the complaint we have considered it appropriate to expedite this complaint in accordance with the Operational Guidelines to the AFCA Rules. Accordingly, thi s complaint has not been the subject of a preliminary assessment and has proceeded directly to determination. The determination is made by a panel consisting of the ombudsman together with a consumer representative who has extensive experience in consumer claims and an industry representative who has extensive experience in the insurance industry. This complaint has been determined based on what is fair in all the circumstances, having regard to the relevant law, good industry practice, codes of practice and previous decisions (which are not binding). Parties have had the opportunity to respond There has been a full exchange of all material information relied on for this determination and each party has had the opportunity to address any issues raised by the other. All material provided by the parties has been reviewed and considered. While the parties have raised numerous issues in their submissions, for the purposes of this determination, commentary has been restricted to those issues considered directly relevant to the outcome only. 3.2 Summary of Expert reports The insurer’s engineer, MO, report 14 November 2019 : > no tests undertaken on the underground stormwat er pipes, it is possible leaks in these pipes are contributing to the house’s movement > the floor level surveys show movement since 2013. This could be interpreted as settling along the northern side, heaving along the southern side, or a combination of both > soils are highly reactive clay which expand significantly with moisture content increase and shrink with a reduction in moisture content > damage to the building is consistent with differential footing movement caused by changes in the moisture content of the foundation soils > the moisture changes have been caused by many factors including: > moisture demands of nearby trees > seasonal moisture fluctuations > environmental changes including the redevelopment of the northern neighbours site > leaking pipes (sewer and stormwater) > discharge from the downpipes in the southwestern corner of the house MO could not conclude the house has not been influenced, to some degree, by the plumbing issues. Determination | Case number: 722888 Page 9 of 12 The insurer engineer (LO) report 12 March 2020 > trees to the east and west of the property were removed about 10 years ago > no current defect in the sewer lines > pressure drop in mains wat er line, no wat er escape observed > leaking garden tap is likely caused of pressure drop > no localised heave to the southwest near the reported sewer overflow > pattern of foundation falls towards the nort heast side consistent with footing settlement however, it is not near to, and is to the high side of, the sewer overflow and any overflow would be redirected away from this area > pattern of footing movement is not consistent with a localised increase in moisture content from the reported sewer overflow > site falls towards the southwest, reported sewer overflow and gully trap are to the sout hwest and any escape of water would flow away from the building > escape of liquid would caus e localised movement and damage, crack pattern analysis indicates wides pread movement and damage > the cause of damage is not the reported sewer overflow but is instead long-term moisture content variation, inadequate foundation depth and other construction issues. LO report 7 August 2020 > MA asserts that our investigation did not consider the MP reports and survey results. I confirm that these reports and results were not provided to us during our investigation. However, I have reviewed the MP survey results included in MA’s report. I advise that the results from MP further support our findings and conclusion. > The survey results from MP confirm widespread building movement occurring over the years consistent with the extremely reactive soil. The survey results confirm no anomalous movement localised to the vicinity of t he claimed overflow. Movements of greater degree were detected in areas remot e from the overflow indicating an overflow is not the cause of building movement. The past engineers also came to the same conclusion. > the assertion that wides pread leaking of the se wer line is occurring is contrary to the findings of the independent plumbing investigation undertaken by P and I therefore dismiss this. > > MA’s assertion of wides pread leaking due to pressurisation of the pipe as highly speculative and unsupported. No defects were detected to the sewer line and assertions of leaks cannot be substantiated. > a second overflow in 2018 is also unsupported and unconfirmed by the owner. If the second overflow did occur, the owner reports that it occurred from the overflow relief gully evidenc ed by toilet paper observed in the gully grate. This indicates MA’s assumption that water is overflowing from beneat h the porch is incorrect. By Ma’s own analysis, water overflow from the overflow relief gully onto the concrete will not affect any soils. > MA ’s assertion that widespread leaking is occurring is completely unsubstantiat ed and uns upported and cont rary to the independent plumbing advice and inconsistent with the results of the surveys, crack pattern analysis and soil testing. It is my opinion that this unsupported assertion is simply to rebut the evidence of widespread elevations which M could not be ex plain from the initial claim of overflow beneat h the porch. > MA avoids discussing the impact of an inadequat ely designed footing system. Inadequate design of a footing system will compromise the performanc e of the structure. > Given the extreme soil reactivity, solid brick construction without articulation and abnormal soil moisture conditions caused by trees, the inadequate design of the footings is expected to result in wides pread and ongoing footing movement issues, which is consistent with the results of the building survey. MA completely fails to address this. > MA ’ s dismissal of abnormal soil moisture conditions caused by the groups of trees is incorrect. Determination | Case number: 722888 Page 10 of 12 > I fail to see how MA dismisses obvious and undisputable facts such as inadequately designed footings and tree root influence yet argues that unsubstantiat ed and u nproved speculation of wides pread leaks is the primary cause of damage. > MA also fails to note the evidence of wides pread prior repairs and damages to the building and absence of any localised damage to the direct vicinity of the claimed overflow. This further indicates no localised movement caused by the overflow. LO report 22 October 2020 > Notwithstanding, this further testing indicates the possibility of a new and formerly undetected and undisclosed defect in the sewer line. > the extent and accuracy of the plumbing testing is not sufficient to provide new evidence to alter the findings of our investigation. The plumber has not identified the nature or location of the claimed defect. > the reduction in water level during the static test can be occurring due to a break or leaking joints that leak water under pressure. This does not mean the line is leaking under normal flow conditions. > a soil investigation was undertaken during our attendance in the direct vicinity of the newly claimed sewer defect, and the foundation soils were found to be dry with no anomalous elevation in soil moisture consistent with an ongoing escape of water. This indicates water escape under normal flow conditions is not occurring. > more thorough testing of the line is necessary to determine the nature or existence of a defect. This should involve the commission of an independent plumber appointed by (insurer) with sufficient expertise to CCTV the line. > This is critical given the initial plumbing investigation undert aken by Pinnacle in October 2019 identified no cracks in the sewer line. This can indicate that either (i) the defect is new, or (ii) the escape of water is not occurring from a break in the line but is leaking under pressure from pipe connections and joints. If scenario (ii) is occurring, then water escape under normal flow is not expected. > the nature of the potential defect will be paramount in determining if an escape of water is the cause of footing movement and damage. However, I advise that review of the building survey results from our investigation, and previous investigations indicat e an escape of water from this new location is not the proximate cause of footing movement. Complainant engineer (MA) report 19 June 2020 > sewer pipework was leaking in vicinity of rear porch > the sewer blocked and water overflowed from under the porc h via the joint where the porch meets the house > soils are highly reactive > the escape of water from the sewer was the main cause of the soil swell leading to the cracking damage > the cracking is mainly along the southern side and is non -existent along the northern side > the damage is consistent with heave along the southern side of the hous e. MA report 29 July 2020 DISCUSSION AND CONCLUSION > The Insurer has based their decision regarding the c urrent claim on the report and comments by LO and have not considered other relevant facts. > The LO report (12 March 2020) and comments (30 June 2020) do not consider the following facts: > Comparison of the building surveys undertaken in 2013 and 2020 clearly show that the southern side of the house has heaved, in particular at the kitchen area. > Significant plumbing defects were shown (by excavation) to be current under and around the porch area of the house, which is adjacent to the kitchen. These defects include: Determination | Case number: 722888 Page 11 of 12 > IP ’ s were not extended to ground/paving level. > The tops of multiple IP ’ s were not installed correctly, un-grout ed, or broken (penetrated by rods). > The vitreous clay sewer piping is in very poor condition and a static head test could not be performed. > The soil under the porc h area was found to be very wet when excavated in 2020. > It appears that a sewer pipe from the kitchen is loose and leaking. > the sewerage black flow event in 2015 and again in 2018, would have pressurised the sewer pipe system, causing leaks into the soil under the southern side of the house > The water escape events would have provided water under pressure directly into the clay stratum under most of the southern side of the house, causing wetting of the soil and heave. > This heave showed in the survey results of 2013 compared to 2019/2020. > The events occurred in 2015 and most recently in 2018 and would not have dried since this time. Henc e the comments that no recovery of damage has been noted on site with closure of cracking. > There was some cracking damage and movement to the house in 2013, but his worsened significantly after 2015. > The trees LO claim to have been removed from adjacent to the house were not planted in the ground but were stored on the ground in landscape bags. > The street trees LO claim to be a caus e of drying are located east of the house and consist of only one tree, not multiple trees. This single tree is toward the outer limit of its zone of influenc e, as it is 10m tall and 10m from the building. Hence, it would have minimal effect. > If the trees were t he cause of edge settlement, it would be expected that the eastern edge of the house would dry and settle. This does not appear to be the case and does not match the damage noted to the hous e, or the survey results. MA report 9 October 2020 > The plumber found that the sewer pipe is leaking adjacent the eastern wall of the kitchen, which is along the southern side of the building. > it has been shown by plumber’s numerous times that all the sewer pipework (which extends along the southern side of the house and slopes down to the east) is leaking and allowing water to enter the soil. > the last three surveys were undertaken by different parties in 2019 and 2020 and all showed similar results – that the southern side of the house was 20 to 30mm higher than the northern side. > It has been agreed that the soils under the house are highly expansive and will swell with an increase in the moisture content. > It has been shown that there were sewer backflow events in 2015 and 2018, which resulted in the sewer system along the southern side of the house become pressurised and overflowing. > It has been shown that the southern side of the house has risen 40 to 50mm relative to the northern side of the house over the period 2013 to 2020. > Henc e, it is concluded that water leakage from the sewer pipes, particularly during the 2015 and 2018 blockage events, have caused a water escape event and caused heave along the southern side of the house 3.3 Relevant policy wording General exclusions Exclusions. We do not insure you for any loss or damage that is caused by or arises from: … Determination | Case number: 722888 Page 12 of 12  settling, expansion, shrinkage or any earth movement other than earthquake. … Residential Home and Contents Insurance Residential Home and Contents Insurance insured events. We will insure your building and contents at the site against loss or damage caused by the following events if they occur during your period of insurance. … Escape of liquid We will cover Loss or damage caused by accidental escape of liquid from any:  fixed pipe  fixed tank  waterbed  fish tank, or  any fixed item that is used to hold the liquid. We will also pay for the reasonable exploratory costs in locating the source of the damage, provided we have agreed to pay for the loss or damage caused by the escape of the liquid.

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.