Home / NTI Limited / Determination 717116
Determination 717116
Commercial insurance claim for excavator hydraulic pump and track damage denied
Summary
The complainant's excavator was damaged during a flood-related recovery and the insurer denied the claim as wear and tear and excluded track damage. AFCA upheld the denial of the main claim but ordered the insurer to pay towing, testing and oil change costs.
The insurer's expert evidence showed the hydraulic damage resulted from pre-existing wear and cavitation, and the policy excludes cut or ruptured rubber tracks.
Issues
- Claim denial primary · not upheld“The panel is satisfied that the insurer is entitled to rely upon its policy exclusions to deny this aspect of the claim.”
- Poor claim handling secondary · not upheld“The panel is not satisfied that the complainant has established that the claim was mishandled by the insurer.”
Subjects and remedies
business interruptionpay claim
Related
All NTI Limited determinations · Find similar determinations
Text of the determination
Determination
Case number 717116
Financial firm NTI Limited
Determination | Case number: 717116 Page 2 of 9
Case number: 717116 16 March 2021
1 Determination overview
1.1 Complaint
The complaint relates to a claim by the complainant under his Commercial Insurance
policy held with the financial firm (insurer) in relation to damage to an excavator,
resultant expenses and loss of income.
The insurer has denied the complainant’s claim and says that th e losses are excluded
from coverage under the policy provisions.
1.2 Issues and key findings
Is the insurer entitled to deny the complainant’s claim for the damage to the
excavator?
Based on the exchanged material, the insurer has established the application of
policy exclusions which entitle it to deny the complainant’s claim for the damage to
the excavator.
Is the insurer entitled to deny the complainant’s claim for resultant expenses
and loss of income?
The complainant has not established a valid claim under the terms of the policy for
the damage to the excavator and the result is that the insurer is entitled to deny the
balance of the complainant’s claim.
Is the insurer required to pay the complainant compensation for the way in
which it handled the claim?
The insurer is not required to pay the complainant compensation for the way in which
it handled the claim.
1.3 Determination
This determination is in favour of the insurer.
The insurer is not required to pay the complainant’s claim for damage to the
excavator, additional expenses incurred or loss of income.
The insurer is required to pay the complainant for the towing of the excavator from the
scene of the loss to the repair shop, the initial testing costs of $445.50 and $280.50
respectively and for the hydraulic oil change costs of $420.50.
Determination | Case number: 717116 Page 3 of 9
2 Reasons for determination
There has been a full exchange of all material information relied for the purposes of
this determination and each party has had the opportunity to address any issues
raised by the other.
This complaint has been determined based on what is fair in all the circumstances,
having regard to the relevant law, good industry practice, codes of practice and
previous decisions where applicable.
A panel has determined this complaint. The panel consists of the panel chair
Ombudsman, a representative with extensive experience in the insurance industry
and a representative with extensive experience in consumer claims.
While the parties have raised numerous issues in their submissions, for the purposes
of this determination, commentary has been restricted to those issues considered
directly relevant to the outcome only.
2.1 Is the insurer entitled to deny the complainant’s claim for the damage to
the excavator?
Coverage of the policy
The coverage provided by the complainant’s Commercial Insurance policy is detailed
within the Product Disclosure Statement (PDS) and the Certificate of Insurance (COI).
The policy provides coverage in the event of damage to an insured vehicle in an
accident during the period of insurance.
Accident and accidental are defined within the PDS to mean:
A sudden, unintended, unforeseen, unlooked for event or mishap, which is not
expected nor designed.
The coverage provided by the policy is subject to exclusions which are also detailed
within the PDS.
The PDS details:
…
Determination | Case number: 717116 Page 4 of 9
…
It is accepted insurance law that the complainant carries the initial onus to establish a
loss which is covered by the policy. This is known as establishing a valid clai m.
The primary circumstances of the loss are not in dispute and there is no suggestion
that the loss was not an unintended, unforeseen, unlooked for event or mishap. There
is no dispute that the loss was either expected or designed.
Having reviewed the exchanged material, the panel is satisfied that it is the cause of
the damage to the hydraulic pump which is in dispute and not whether it was sudden
for the purposes of the coverage provided by the policy.
Having reviewed all the exchanged material, the panel is satisfied that the
complainant has established a loss which meets the coverage requirements of a valid
claim under the policy.
The onus now shifts to the insurer to establish the application of an exclusion within
the policy upon which it says it is e ntitled to deny the claim.
Circumstances of the loss
The exchanged material confirms that on 18 January 2020, the complainant’s
excavator was involved in an incident.
Whilst the fact that an incident occurred is not in dispute, there is not necessarily
agreement between the parties as to the details of the incident.
When lodging his claim with AFCA, the complainant advised that he received a call
from a work colleague stating that his excavator was about to be submerged with
rising water and that on arri val at the site, the complainant attempted to remove the
machine from the water, during which time, it sustained damage.
Within its internal dispute resolution documentation, the insurer describes the
excavator as allegedly becoming bogged and sustaining water damage to the
hydraulic pump and cuts to the rubber tracks.
The engineer (CES) engaged by the insurer says it contacted the complainant and
within CES’s report dated 23 March 2020, CES says:
He informed me that the excavator was parked on a bank when the machine
required moving due to impending floodwaters. I was provided photos of the
machine adjacent to floodwaters by (the insurer). The insured informed me the
machine was on a steep and slippery slope that made relocating the machine
Determination | Case number: 717116 Page 5 of 9
difficult and it took approximately one hour to move the machine away from the
floodwater to safety. This required operating the engine at maximum RPM and
using the bucket of the machine to push it up the bank as the tracks were slipping.
After recovering the machine, the insured noticed reduced hydraulic performance
and damage to the tracks. The insured advised me his company had moved the
earth that created the bank, and it had shale in it.
Within a report dated 27 November 2020, from an automotive consulting engineer
(PJS) engaged by the complainant, it is stated:
The machine owner has reported the machine was recovered from the threat of
flood waters approaching a job site… During the course of this recovery, the
machine was subjected to operation at maximum power for a period of
approximately one hour due to the angle of the slope and the slippery condition of
the ground surface. The operator utilised the excavator boom to assist by both
digging the slope to reduce the incline and also to assist in pushing the machine
up the incline and away from the impending flood waters.
Within submissions provided by the complainant, he says:
… the machine was parked at the base of the bank on flat ground and was
removed from water approximately one metre deep and rising, causing the
machine to become bogged in the water and difficult to remove….
The complainant has provided a photograph and video of the incident event.
Further, the complainant says that the photograph shows the pump would have been
under water and that the pump, cooled by water whilst over-heating, would cause the
metal in the pump to expand and contract irregularly, possibly causing internal
clearances to vary outside manufacturer’s limits.
The complainant says that the video supplied shows that whilst digging, the rear of
the machine was propped up on the blade keeping the pump out of the water when
attempting to climb the bank. When the blade had to be raised, the rear of the
machine was lowered, submerging the pump and this was done repeatedly during the
event.
Having inspected the excavator, CES confirmed his view that the damage to the
hydraulic system is a result of wear and tear and not the result of a single incident.
CES specifically concluded that it was most likely that the pump was already suffering
from wear issues and the recovery event expediated the failure.
The panel does not propose to repeat the full details of CES’s three reports here, but
notes the following conclusions from CES:
The failure has occurred at approximately 3,680 hours, which is approximately 280
hours after the insured purchased it second hand.
Determination | Case number: 717116 Page 6 of 9
CES was informed by the insured there was no service history prior to the machine
being purchased second hand, which CES says means approximately 3,400 hours
of unaccounted use and service history.
The P3 hydraulic pump has been damaged by cavitation, which CES says is
agreed to by PJS.
Cavitation is a form of fatigue failure. Fatigue failures do not occur over three hours
as thousands often millions of repeated loading cycles are required.
Unacceptable levels of ferrous material were found in the oil sample taken by ( the
manufacturer) which CES says supports PJ S’ theory of excessive wear caused by
cavitation.
The hydraulic oil showed no sign of water contamination in either of the two
samples taken after the incident and analysed by two separate laboratories.
Further, CES is of the view that the hydraulic pump was not submerged in water, but
internal areas of the machinery were sprayed with water.
CES describes the hydraulic system as a closed system with a filler and breather well
above the reported flood water levels.
The panel notes that PJS did not have the opportunity to personally inspect the
excavator and his report is based upon materials provided by the complainant and
detailed within PJ S’ report , including the report from CES dated 23 March 2020.
Within the report from PJS, he says:
… I am of the opinion that the damage to this hydraulic pump would have been
possible and probable due to the extreme operating circumstances at the time of
the recovery of the machine. This opinion is further supported by the fact the
machine was being used on a site under contract requirements that detail the
condition and serviceability required of the machinery on that site… Had the
hydraulic pump been damaged prior to the incident as stated by (CES) there
would be positive results from the oil analysis that supported his opinion. In this
case, that evidence was not found in the oil samples. It is therefore more probable
than not that the damage to the hydraulic pump occurred during the recovery of
the machine from the impending flood waters.
The panel notes that in his report, PJS challenges the chain of custody of the oil
samples.
The panel does not accept the concerns of PJS in relation to the chain of custody as
there is no evidence to suggest that the oil was contaminated in some other way.
Further, the panel is satisfied that CES has specifically addressed the concerns of
PJS in relation to the oil contamination and the concern of possible water
contamination.
Determination | Case number: 717116 Page 7 of 9
Having reviewed all the exchanged material, the panel prefers the evidence of CES
that there was no evidence that water had entered the hydraulic system and further
that there is evidence that the oil was contaminated as a result of the wear a nd tear
associated with the hydraulic system.
The panel also accepts the evidence that the relevant parts generally have a longevity
of 10,000 hours.
Whilst the complainant says the excavator has previously been serviced by someone
suitably qualified, there is no evidence of this.
Further, the fact that the excavator had been operating with no issue prior to the
event, does not establish that it was well maintained, despite the suggestion from the
complainant that he had contractual obligations to ensure that the machinery was well
maintained.
Having reviewed all the exchanged material, the panel is more persuaded by CES
and his assessment of the excavator and the cause of the damage to the hydraulic
system.
Regarding the damage to the hydraulic system of the excavator, the panel is satisfied
that the insurer is entitled to rely upon its policy exclusions to deny this aspect of the
claim.
The excavator tracks
The panel notes that there is some dispute as to whether the damage to the tracks
occurred during the loss event.
Having reviewed all the exchanged material, the panel is satisfied that there is
evidence to support the complainant’s contention that the tracks were in f act
damaged during the loss event.
Whilst CES advised it was difficult to prove if damage to the tracks has occurred prior
to the incident or not, from the description given by the insured of the tracks slipping
on the steep rocky ground, CES was satisfied that it was plausible that damage would
have occurred during the recovery of the excavator.
However, the policy provisions detailed above contain a specific exclusion for loss or
damage caused to rubber tracks through cuts and/or ruptures.
The panel is satisfied that the insurer is entitled to rely upon this exclusion to deny this
aspect of the claim.
The complainant also says that the cables were damaged during the loss event.
The complainant’s onus of establishing a valid claim under the poli cy, extends to
establishing the extent of the damage claimed for.
Determination | Case number: 717116 Page 8 of 9
Having reviewed all the exchanged material, the panel is satisfied that evidence does
not establish that this event caused damage to the cables.
In the absence of this, the insurer is also entitled to deny this aspect of the
complainant’s claim.
2.2 Is the insurer entitled to deny th e complainant’s claim for additional
costs and loss of income?
The complainant says that because of an email he received from the insurer, he was
induced to hire an excavator to continue working on site. The complainant says that
he was indemnified under a clause of the policy for these costs.
Whilst the panel accepts that the email sent by the insurer may have given this
impression, the panel notes that the email was sent to the broker for the complainant.
In the panel’ s view, the broker should have known that the coverage for an alternate
excavator was always subject to acceptance by the insurer of the claim.
Further, the panel notes that the complainant had contractual obligations regarding
the work which was being carried out at the time of the loss event.
In those circumstances, the complainant would have needed an alternate excavator
to complete his contractual obligations. Thus, he was always likely to incur some
costs.
In any event, any obligation the insurer had to the complainant for alternate hire costs
were subject to acceptance of the claim by the insurer.
The panel is also satisfied that any claim for loss of income made by the complainant
is subject to acceptance of the claim.
The insurer is entitled to deny these aspects of the complainant’s cl aim.
2.3 Is the insurer required to pay the complainant compensation for the way
it handled the claim?
Under AFCA’s Rules, we may award compensation (capped at $5,000) for non -
financial loss where a complainant has suffered an unusual degree or extent of
physical inconvenience, time taken to resolve the situation or interference with their
expectation of enjoyment or peace of mind.
However, we adopt a conservative approach to the award of compensation for non-
financial loss. We expect complainants to be modestly robust and bear the usual
stress and inconvenience associated with an insurance claim.
The onus is on the complainant to establish he has suffered a loss because the
insurer mishandled the claim.
Determination | Case number: 717116 Page 9 of 9
The exchanged material confirms that the loss event occurred on 18 January 2020
and the claim was declined on 2 April 2020.
There is no doubting that the claim was complex and required expert opinion.
During the period between the claim event and denial of the claim, the insurer
engaged an expert engineer (CES) who provided a detailed report.
It was based upon this detailed report from CES, that the claim was denied.
It is accepted insurance law and a provision of the policy that the insurer is entitled to
investigate the circumstances of a loss.
Having reviewed the circumstances of the claim and the timeframes involved, the
panel is not satisfied that the complainant has established that the claim was
mishandled by the insurer.
The insurer is not required to pay the complainant compensation.
2.4 Additional matters
The complainant has made an additional claim for towing expenses and other items.
Having reviewed all of the exchanged material, the panel is satisfied that having
requested inspection of the excavator, it is fair that the insurer pay the cost to tow the
excavator from the loss site to the repair shop, to pay the initial testing costs of
$445.50 and $280.50 respectively and to settle the complainant for the hydraulic oil
change costs of $420.50.
The insurer is not required to take any further action regarding this matter.