Home / RACQ / Determination 716967

Determination 716967

Claim declined for damage to concrete water tank

FirmRACQ
Decided2020-12-18
ProductGeneral Insurance · Home building and contents
OutcomeFor the firm
Amount awarded—
Non-financial loss—
Amount claimed—
SourceAFCA PDF

Summary

A homeowner claimed for damage to a concrete water tank, attributing it to a storm or a leak from a new liner. AFCA accepted the engineer's evidence that long-term corrosion and poor construction caused the failure, so the damage was not caused by an insured event.

Long-term deterioration from corrosion is excluded, and a leak from the tank or its liner is not covered because the leaking item itself is excluded from the leak cover.

Issues

Subjects and remedies

no remedy

Related

All RACQ determinations · Find similar determinations

Text of the determination

Determination Case number 716967 Financial firm RACQ Insurance Limited Determination | Case number: 716967 Page 2 of 6 Case number: 716967 18 December 2020 1 Determination overview 1.1 Complaint The complainant holds a home insurance policy (policy) with the financial firm (insurer). On 10 May 2019, the complainant lodged a claim seeking cover for damage to a concrete water tank (tank), said to have occurred on 8 May 2019. The insurer has declined the claim and says the damage to the tank is not due to an event covered under the policy. Rather, that the damage is the result of wear, tear and gradual deterioration, which is excluded under the policy. Alternatively, the insurer also says the policy does not cover the item from which a leak occurs. 1.2 Issues and key findings Has the complainant established a valid claim under the policy? No. The information shows that the damage to the tank is because of long term deterioration due to ongoing corrosion and weakening of the internal steel reinforcement and structure, caused by its design and construction. The insurer is entitled to decline the claim as the damage to the tank was not caused by an insured event. 1.3 Determination This determination is in favour of the insurer. The insurer is entitled to decline the claim in line with the policy. Determination | Case number: 716967 Page 3 of 6 2 Reasons for determination 2.1 Has the complainant established a valid claim? The policy is an insured events contract of insurance The policy covers the insured property for loss or damage caused by one or more the insured events listed in the product disclosure statement (PDS). Cover under these insured events is subject to the limitations and exclusions specified in the PDS. There is no dispute the complainant was provided with the relevant policy documentation including the PDS and certificate of insurance (COI). Complainant says the damage is due insured events ‘Storm’ or ‘Leaks’ It is established law that the onus first rests with the claimant to establish, on the balance of probabilities (that is, more likely than not) that the loss falls within the terms of the policy. The complainant says that the damage to the tank is covered under the insured events ‘Storm’ or ‘Leaks’. The complainant believes a recently installed tank liner, which allowed water levels in the tank to rise more than they had previously, has failed (leaked) most likely during a storm. He says this has applied pressure to the tank at its weakest point resulting in the damage claimed. The complainant also notes that the first consultants ‘AR’ appointed to the claim by the insurer advised the damage was due to ground movement. However, this was proved to be incorrect. It was because of this that the insurer appointed engineer ‘SB’, based on who’s report the insurer has declined the claim. The complainant says it is not fair or reasonable that the insurer be allowed to take two bites at the cherry. He is of the opinion the policy does respond to the damage claimed and that he is entitled to at least some cover under the policy. Expert evidence does not support the damage is due an insured event The insurer first appointed AR, who formed the view the damage was the result of ground movement. The complainant was not satisfied with the assessment and so the insurer appointed structural engineer SB to the claim. I acknowledge and accept the complainant’s concern regarding AR’s findings and that there is an absence of reasonable evidence supporting the damage to the tank was the result of ground movement. I have carefully reviewed the report provided by SB dated 12 September 2019 and find this to be compelling. SB is suitably qualified to complete an assessment of the tank and provide his opinions and findings regarding the damage noted. Determination | Case number: 716967 Page 4 of 6 SB’s confirm ed the tank had significant damage in the form of a section approximately 1.5m wide and to the full height of the tank having had sheared away. He noted that the steel bars used for reinforcement in the tanks construction had corroded and all sheared away at the failure point in the concrete. SB says the construction of the tank was not to standard with the concrete cover between the inside face of the tank and the internal steel bars being only around 10mm. In line with the required Australian Building standards (AS 3735), concrete cover should range between 35-75mm, and for constructions like the tank, 40mm would be required. Concrete cover allows for corrosion prevention. In SB’s opinion, the failure of the tank is directly rel ated to the ongoing corrosion and weakening of the steel reinforcement bars over an extended period. This being due to the poor design and construction of the tank. The insurer provided information that there was no rainfall or storms in the area of the insured property on the date of loss or the days leading up to it. Given this, I am not satisfied storm can be accepted to be the cause for the damage to the tank. I acknowledge the complainant’s view that the damage is due to a leak from the liner installed in the tank. However, in the absence of information to support this, I am not satisfied this leak, if it existed, has been shown to the be the cause for the damage. The PDS, under the insured event ‘ Leak s’ , covers loss or damage caused by the leak, however, clearly excludes from cover the item from which the leak occurs. In this instance, had it been shown that the damage was due to a leak from the tank (which it has not), the tank would be considered the leaking item and as such the damage to the tank would not be covered under the policy. I accept it is reasonable to consider the liner to form part of the tank. The insurer is entitled to decline the claim As the damage to the tank was not caused by an insured event, the insurer is entitled to rely on the terms and conditions of the policy to refuse payment of the claim. Determination | Case number: 716967 Page 5 of 6 3 Supporting information 3.1 AFCA approach to this complaint This complaint has been determined based on what is fair in all the circumstances, having regard to the relevant law, good industry practice, codes of practice and previous AFCA decisions (which are not binding). There has been a full exchange of all material information relied on for the purposes of this determination and each party has had the opportunity to address any iss ues raised by the other. All the material provided by the parties has been reviewed and considered. 3.2 Expert evidence Record Key points SB Engineers Report 12 September 2019  c ompleted an assessment at the insured home on 26 August 2019  t he tank is approximat ely 2.2m tall and 5.5m diameter  a new tank liner was installed recently before the failure  the damage wa s not visible from the top and is located t o the no rth - western area of the  a section of the tank wall (approximately 1.5m wide and full height) has sheared away  t he base of the tank wall is around 100mm thick and tapers up to the top where the thickness is only around 45mm thick  noted there are steel bars in the tank wall at around 200mm centres . The bars have all corroded and all sheared at th e failure point in the conc rete  c oncrete cover between the inside face of the tank and the internal steel bars is only around 10mm  relevant Australian Standards for these structures is AS 3735, first published in 1991. Section 4.4.3 states concrete cover should range between 35 - 75mm depending on the conditions and type of construction  SB estimates in this case the concrete cover required would be 40mm, however, w as far less at 10 - 20mm  ample concrete cover allows corrosion prevention  the tank lacks in design and construction  In SB’s view, the failure of the tank is directly related to the ongoing corrosion and weakening of the internal steel reinforcement due to long term deterioration and lack of concret e cover . Determination | Case number: 716967 Page 6 of 6 3.3 Relevant policy terms Leaks Leaks are liquids that are leaking, bursting, discharging or overflowing from certain items or devices. … Yes ✔ The following items or devices malfunction at or near your h ome and leaks from them cause loss or damage to your home or contents: • … • fixed domestic items which include water tanks, lavatory cisterns and pans, baths, basins and sin ks … … No ✘ Loss or damage to the item or device which leaked … What we don’t cover This section outlines the general things we don’t cover under your policy. They are known as general exclusions. Loss not linked  Loss to your home or contents which can’t be l inked to any identifiable event... Rust and mould  Rust, corrosion, rot, mould or gradual deterioration caused by light, air, the climate (which includes wind, rain or sand) or the passage of time. Wear and tear  Wear and tear through normal use.

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.