Text of the determination
Determination
Case number 710755
Financial firm AAI Limited
Determination | Case number: 710755 Page 2 of 21
Case number: 710755 2 September 2020
1 Determination overview
1.1 Complaint
The complainant held a home and contents policy with the financial firm (insurer). On
4 September 2019, the complainant lodged a claim after discovering a water leak in
the bathroom.
After assessing the claim, the insurer offered to cash settle the complai nant for the
repairs to the bathroom, less excess. However, the insurer denied other aspects of
the claim, namely cracking and movement related damage throughout the property.
The insurer says this damage was not due to the leak and is not covered under the
policy.
The complainant disputes the insurer’s assessment stating that the movement related
damage was caused by the water leaking in the bathroom and under the property.
This has caused the foundations to subside. Therefore, the complainant is seeking
the insurer to cover the additional repairs required. This includes re-stumping the
property.
1.2 Issues and key findings
Is the insurer’s settlement offer fair ?
Yes. The available information does not show the movement and cracking damage
was caused by the leaking pipe or is otherwise covered by the policy. Therefore, the
insurer’s settlement is fair.
1.3 Determination
This determination is in favour of the insurer.
The insurer ’s settlement offer is fair.
Determination | Case number: 710755 Page 3 of 21
2 Reasons for determination
2.1 Is the insurer’s settlement offer fair?
Complainant must show a valid claim
The initial onus is on the insured to show, on the balance of probabilities, a loss
claimed falls within the cover provided by the policy of insurance. This is known as
establishing a valid claim. If the complainant can establish a valid claim, the onus
transfers to the insurer to establish it is entitled to decline the claim.
The complainant ’s p olicy covers loss or damage caused by an insured event during
the period of insurance. One of these events is escape of liquid.
The PDS defines an ‘ event ’ or ‘incident’ as:
a single event, accident or occurrence which you did not intend or expect to
happen
There is no dispute that a leaking pipe was identified in the bathroom a nd this has
caused damage. Therefore, a valid claim has been established for this damage.
The dispute is whether this event caused the movement and cracking damage
throughout the property.
Various expert reports have been provided
The insurer has produced various reports to support its position. All of these have
been summarised in section 3. The panel does not propose to go through them in
detail.
The main report is from engineer JH. JH concluded the movement damage is
associated with poor foundation performance over many years.
The complainant has provided no expert evidence in support. The complainant says
that when they levelled the house in 2017, the contractors did not observe the
subfloor being wet. However, no evidence was provided from these contractors
directly.
JH’s evidence is persua sive
Based on the available information, the panel does not accept the information shows
the movement and cracking damage is due to the leaking pipe. This is because JH’s
evidence is persuasive.
JH noted that a leak would cause localised footing movement. However, floor level
surveys show footing movement is global and significant.
Determination | Case number: 710755 Page 4 of 21
There are numerous examples of the property suffering long term footing movement.
This includes the following:
plasterboard cracking that is aged and not proximate to the leak
patched areas in the home that have re-opened
stepped cracking in the brickwork with evidence of repatching
a ‘crudely lain line of concrete’ at the rear of the dwelling which shows an attempt
to keep excessive water from flowing into the property
JH, and other experts, identified several long-term issues with the site drainage. This
includes the following:
insufficient grading of the perimeter – the line of concrete installed at the rear is
consistent with this
a stormwater line was installed above the west side of the property and is
discharging to the surface of the garden – it is unclear when this was installed but
confirms there is an issue with this aspect of the stormwater system
a drain at the rear of the property that was still connected to the original and
disconnected damaged stormwater line – water from the rear of the property is
channelled to the damaged plumbing lines
damage to a sewer line between the kitchen and toilet
a non-compliant plumbing line installed to extend the rear gulley outlet
The long-term movement is consistent with the fact the complainant said he had to
level the property in 2017.
Based on all this, the panel is not persuaded the movement and cracking damage
was caused by the leaking pipe in the bathroom.
Movement and cracking damage is not covered
The panel has considered whether the policy could apply to some of the site drainage
issues identified (e.g. damaged sewer line). The panel does not accept it does for the
following reasons.
The information must show the loss or damage was caused by a single event,
accident or occurrence. It is not clear from the available information that one specific
incident caused the long-term foundation movement or that this incident is an insured
event.
Further, it is far from clear if the event occurred during the period of insurance. The
complainant had incepted the policy on 21 June 2016. The policy lapsed on 21 June
2017. On 26 January 2019, a new policy was arranged which the claim was lodged
under.
Determination | Case number: 710755 Page 5 of 21
The issues identified by JH are long-standing and could have readily occurred before
the insurer was on risk. This is consistent with the fact that when the insurer inspected
the property for a previous claim on 9 June 2016, there was pre -existing damage and
patching evident. This shows the movement was occurring before then.
Accordingly, the information does not show the loss occurred whilst the insurer was
on risk or was caused by an insured event.
Therefore, the panel does not accept the insurer is liable for the movement and
cracking damage claimed.
Insurer’s offer is fair
The insurer has provided a scope of works to repair the bathroom damage. This
includes mould remediation limited to the bathroom.
There is no evidence to show this scope of works is unreasonable.
The insurer has agreed to cash settle the complainant as follows:
$17,439.51 – this is based on the builder’s quote for these scope of works
$3,487.90 – this is a 20% uplift/transfer of risk given the insurer is cash settling the
claim
$3,000 for temporary accommodation – this is based on a daily rate of $150 over
20 days
The panel accepts it is reasonable for the insurer to cash settle the claim given the
other maintenance issues identified.
The panel also agrees the amount is reasonable. It is based on a quote with a 20%
uplift. This uplift should account for the fact the quote is not actionable and the risk of
the works are being transferred to the complainant. There is also no evidence to
refute the fact that the rate of accommodation or the time required to conduct the
mould remediation (two weeks) in the bathroom is reasonable.
Accordingly, the panel accepts the insurer’s cash settlement is fair in all the
circumstances.
Determination | Case number: 710755 Page 6 of 21
3 Supporting information
3.1 AFCA Approach
This complaint has not been the subject of a recommendation. Due to the nature of
the complaint, it has been referred directly to a panel for determination, in line with the
Operational Guidelines to the AFCA Rules. The panel consists of an Ombudsman
and two representatives with consumer and insurance experience .
The panel has decided this complaint based on what is fair in all the circumstances,
having regard to legal principles, applicable industry codes or guidance, good industry
practice and previous relevant determinations of AFCA or predecessor schemes
(which are not binding).
There has been a full exchange of all material information relied on for the purposes
of this determination and each party has had the opportunity to address any issues
raised by the other.
The panel has reviewed and considered all the material provided by the parties. While
the parties have raised numerous issues in their submissions, for the purposes of this
determination the panel has restricted its commentary to those issues that it considers
directly relevant to the outcome only.
3.2 Relevant Policy Terms
Page Product Di sclosure Statement
22 Escape of Liquid
We cover
Loss or damage to the building caused by liquid leaking, overflowing
or bursting from any of the following:
refrigerators, freezers, dishwas hers and washing machines;
any drain, fixed pipes, roof gutters or guttering and rainwater
downpipes, drainage and sewage systems
fixed tanks
swimming pools or spas
waterbeds
baths, sinks, toilets and basins
fixed heating or cooling system;
water main, fire hydrant or water supply pipe;
an aquarium.
We do not cover
loss or damage caus ed by flood or storm surge;
Determination | Case number: 710755 Page 7 of 21
Page Product Di sclosure Statement
wear and tear, or loss or damage by the escape of liquid occurring
as a result of a gradual process of leaking, splashing, dripping or
overflowing over a period of time when you could reasonably be
expected to be aware of this condition
37 What we do not cover – general exclusions (cont’d)
You are not covered under any section of your policy for damage,
loss, cost or legal liability that is caused by, arises from or involves:
Defect, structural fault or design fault
a defect, structural fault or design fault that you knew about (or
should reasonably have known about) and did not fix before the loss
or damage occurred (e.g. if there are signs that a defect previously
caused damage, we will not pay a later claim for further damage
from this defect). a defect, structural fault or design fault that you
knew about (or should reasonably have known about) and did not fix
before the loss or damage occurred (e.g. if there are signs that a
defect previously caused damage, we will not pay a later claim for
further damage from this defect).
Ground movement
erosion, vibration, subsidence, landslip, landslide, mudslide,
collapse, shrinkage or any other earth movement, but we will cover
landslide or subsidence that is specifically covered under the
following insured events:
• ‘Storm’;
• ‘Flood’ (but only if you have cover for ins ured event ‘Flood’);
• ‘Earthquak e and Tsunami’;
• ‘Explosion’.
40 What we do not cover - general exclusions (cont’d)
You are not covered under any section of your policy for damage,
loss, cost or legal liability that is caused by, arises from or involves:
Wear, tear and gradual deterioration
wear, tear, rust, fading, rising damp, mould, mildew, corrosion, rot,
action of light, atmospheric or climatic conditions or gradual
deterioration such as, but not limited to:
• tiles and their adhesive or grouting breaking down;
Determination | Case number: 710755 Page 8 of 21
Page Product Di sclosure Statement
• weathering of roof tiles or roof ridge capping;
• gradual weathering and breakdown of bricks, mortar or concret e.
55 Well maintained and in good condition
means the building does not have any faults or defects that might
cause loss or damage to building, loss or damage to property of
others or injury to people. This includes but is not limited to the
following:
• the roof does not leak when it rains;
• there are no areas of the roof that are rusted through;
• there is no wood rot, termite or white ant damage to the building;
• there are no holes in floors, walls, ceilings or any other parts of
your building (e.g. external wall cladding, internal plaster,
floorboards);
• there are no boarded up or broken windows;
• there are no steps, gutters, flooring, walls, ceilings or any other
areas of the buildi ng that are loose, falling down, missing or rusted
through;
• all previous damage including damage caused by flood has been
repaired;
• the building is not infested with vermin;
• there are no squatters or unauthorised persons occupying the
building.
3.3 Relevant Expert Reports
Record Key points
Insurer Plumber ( BB )
Report
6 September 2019
a rrived on site to conduct a leak detection.
a hissing noise could be heard in the main bathroom.
t he cold line pressure test failed.
u sed acoustic listening to locate the burst.
t raced noise to below the bath tub area.
g ained limited access to under the house, noted the ground is very
wet with water pooling.
t he burst could be seen on the plastic line near to the bat h trap as
indicate d in the photo.
a dvis ed the Insured to isolat e at the meter when not i n use.
Determination | Case number: 710755 Page 9 of 21
Record Key points
Repair the burst on the cold line unde r the hous e near the bath
trap
Insurer Builder (A1)
Report
9 September 2019
the customer has informed approximately a week ago a
noticeable hissing sound could be heard in the bathroom
the sound was occurring continuously and the ground beneath
the house was wet
cracks have occurred to the wall in the living room which may
be related to the leak
it was explained to the customer that to repair the leak was not
claimable and should be rectified immediat ely to prevent any
damage occurring
the customer advised that they were unable to find a prompt
plumber to repair the leak
a leak could be heard occurring wit hin the lower wall cavity in
the bathroom adjoining the laundry
the subfloor area beneath the house was wet from the leak.
the cracks observed in and around the living room archway to
the entry were observed to be old and not considered to be
consistent with damage caused by the eve nt as they were not in
the vicinity of the leak
leak from cold water pipe in bathroom
a hissing noise could be heard in the main bathroom.
the cold line pressure test failed.
used acoustic listening to locate the burst.
traced noise to below the bath tu b area.
gained limited access to under the house, noted the ground is
very wet with water pooling.
the burst could be seen on the plastic line near to the bat h trap
repair the burst on the cold line under the house near the bat
trap
old hairline cracks t hroughout the hous e wall and ceiling linings
– general wear and tear
old cracks to several floor tiles in kitchen - general wear and
tear
water damage to laundry ceiling – not related to event.
inadequate drainage to rear of property allowing water to flow
towards and under hous e extension
Insurer Builder (A1)
Amended Report
9 October 2019
arrived on site to conduct a leak detection
burst pipe located on the previous inspection has been repaired,
mains pressure test passed
carried out a leak detection to the shower, breach test passed
there is no silicone behind the spindle penetrations allowing large
amounts of water to escape, moisture was
seen with the thermal to adjacent walls and flooring in the hallway
water will be discharging under ho use
w hen flood testing the shower base water was escaping onto floor
tiles from the screen.
Determination | Case number: 710755 Page 10 of 21
Record Key points
i nspected the laundry.
t he trough breac h passed.
s ome wat er is leaking to the below cabinetry from the washing
machine waste entry.
w ashing machine is sound.
REPAIRS TO BE CARRIED OUT:
r epair the leaking shower enclosure. · Repair sealing around the
trough
Insurer Mould Remediation
(FR)
Scope of Works
14 October 2019
t he following quotation has been prepared based on the
information gathered from the onsite inspection conducted by our
Project Manager on 02/10/19 in the presence o f Mrs. Insured and
A1 Builders
t he leaking pipe was underneath the bathroom floor, the bath has
been remove d in order to rectify the leak
t he Insured has installed new tile underlay over the sub - floor
where the bath was and up the walls
p erformed moisture readings with the use of a moisture met er set
on hammer probe mode which indicated timber sub - floor is 80%
moisture affected at depth throughout
i nspected photos from the plumbing leak detection report, which
showed evidence of visual mould growt h on timbers underneath
the house
n on - claim related damages evident in the bathroom around the
shower and vanity;
e ntire house has a lot of non - claim related issues;
s ource removal to be undert aken in bathroom before crawl space
drying can be fully quot ed for;
h ouse is very old and a high chance of containing asbestos,
testing may be required before source removal is undertaken;
Insurer Asse ssor (AS)
Report
22 October 2019
assessor and A1 are of the expert opinions that the pre - existing
damages have been present and occurring over many years
(highly likely to be 10+ years) which has not been maint ained to a
satisfactory standard
due to the p oor deteriorating condition of this property Assessor is
of the opinion that this customer has failed their ‘Duty Of
Disclosure’ when taking out the policy with AAMI
customer’s son his father purchased the home approx. 4 - 5 years
ago
there is clear evidence that this home was purchased with multiple
defects and pre - existing damage throughout the home
there are only 3x external downpipes around the entire home
(located on the LHS of the home) – insufficient downpipes
installed to exist ing guttering
guttering is in poor condition and silicone has been used to seal up
corner junction connections.
customer’s son advised there LHS front corner brickwork which
has dropped and been patched up with mortar/silicone (cracked
Determination | Case number: 710755 Page 11 of 21
Record Key points
brickwork) was pres ent when they purchas ed the home.
customer’s son advised there is a blockage to the earthen ware
pipes underground which they have not unblocked (and have been
well aware of) and rather installed illegal stormwat er plumbing
above ground to the existing 3x downpipes which discharges into
the front yard
customer’s father has installed a risen section (py ramid style) of
roughly installed concrete to the rear concrete path, to prevent
water from flowing in under the subfloor area. This suggests there
has been an ongoing issue of years of rainwat er run off getting in
under the home into the subfloor area
insufficient grade / fall to the concrete path surrounding the home
there are multiple plumbing defects / issues present.
rotted timber fascia boards, cracked p anes of glass windows
sealed with silicone, and cracking to external brickwork around the
home, internal cracking to plaster walls, cornices.
customer’s son advised his father had the existing stumps ‘jacked
& packed’ and relevelled approximately 2 - 3 year s ago.
•pre - existing poor attempt to repair rood ridge capping tiles evident
in photos (long term damage). Roof is in poor condition.
the subfloor (soil / dirt) has turned into a wet area / very muddy
due to a lot of dampness that has entered the subfloo r area (this
all has not been caused by the leak in the bathroom).
client Manager to follow up with (Fraud & Intelligence this
claim/policy
client Manager to forward entire claim and policy to (Fraud &
Investigations) team to review, duty of disclosure is a concern.
client Manager to chase up with *** of A1 Building Group the
following two reports to be obtained
roofing expert report
plumbing CCTV Camera inspection leak detection expert report
Insurer Leak Detection ( LD )
Report
30 October 2019
a rrived on site to carry out a CCTV ins pectio n of the storm
water and sewer
t he storm water runs along the west side of the house in PVC
above the ground inadequat ely supported and discharges onto
the front garde n
o ld earthenware downpipe entry points are still visible and filled
w ith debris
t here is a surface drain to the rear of the property which is still
connected to an ol d eart henware storm water line
t he PVC sewer line was inspected from the toilet and kitchen, a
break was identified nearby as shown in the mud map
t he bathroom and laundry run to a gully which is under the
extension. Unable to access the gully to inspect
i t appears a non - complaint horizontal extension of the gully
outlet has been fit ted as shown in mud map
w hen running both bathroom and laund ry fixtures no water seen
at I/O downstream rear of the property, instead water was seen
discharging under the extension by the gully with wat er po oling
Determination | Case number: 710755 Page 12 of 21
Record Key points
likely due to a blockage
engage a licensed plumber to;
‒ run compliant storm water to the legal point of discharge
‒ connect the surface drain to the storm water
‒ blank old eart henware downpipe entries
‒ repair the break in the sewer
‒ gain access to the gully under the extension, clear blockage
and address non - compliant installation
Insurer Roofer ( RR )
Report
30 October 2019
conducted a roof report
located multiple cracked tiles
some tile are siliconed between joins
various repairs have been carried out previously to ridge capping,
however cracks and gaps remain in mortar
maintenance issues – cracked tiles and m ortar
Insurer Engineer (JHA)
Report
9 January 2020
Conc erns were raised in relation to the condition of the dwelling
following the recent discovery of a plumbing leak under the
bathtub in the bat hroom.
Initially, during the inspection the insured pointed out the location
at which the leak occurred in the bathroom. The insured explained
that the leak had recently been identified by a plumber. It was
advis ed that the bathtub had been removed to repair the damaged
plumbing line.
The insured also pointed out cracking in the interior walls
throughout the dwelling including cracking in the hallway and
meals area during the inspection.
Furthermore, the ins ured explained that mould had recently grown
on some of the ceilings throughout the dwelling.
During an inspection of the exterior the insured advised that the
valley iron and rear guttering had been replaced. However, several
significant structural issues were observed during the inspection.
Further enginee ring investigation of the structure was therefore
required to determine their cause, influenc e on the structure and
the resulting condition of the structure, and whether any of the
damage may be attribut ed to the recent escape of liquid.
The following pho tos indicate the condition of the dwelling at the
time of the inspection
A structural inspection of the dwelling was conducted in order to
determine its condition as well as the cause and extent of any
evident damage. Prior to the JHA inspection the bathtu b had been
removed from the bathroom in order to repair the detected leak.
During the inspection the insured pointed out the location of the
leak as well as some location of minor cracking, separation and
mould throughout the interior. The insured also po inted out repairs
conducted the roof including the replac ement of the valley iron and
guttering.
The inspection noted that the dwelling was constructed on
concrete stumps set into clay - based founding soils. The exposed
Determination | Case number: 710755 Page 13 of 21
Record Key points
subfloor soils founding the dwelling remained very moist indicating
evidence that the recent leak may have caused structural
damages. However, extensive pre - existing and long - term
damages were noted all throughout the dwelling. Further
investigation of the structure was therefore conducted
T he inspection of the dwelling interior observed the reported leak
location in the bathroom. It was noted that the bat htub had been
removed to repair the plumbing leak prior to the engineering
inspection. Fibre cement sheeting had been installed over the
fl ooring and walls as a temporary lining following the removal of
the bathtub.
An inspection of the remaining floor and wall linings within and
around the bathroom did not observe evidence of recent cracking
or movement - related damage throughout this area. An inspection
of the sunroom extension at the rear of the bathroom also did not
note any furt her evidenc e of recent cracking or movement - related
damage.
It is important to not e that when significant leaks occur, the
reactive founding soils of the subfloor often swell at the leak
location. This swelling can cause differential movement of the
structure and cracking to the brittle materials lining the interior
such as the floor tiles and plasterboard walls at the leak location.
There was a noticeable lack of recent cracking observed
throughout the bathroom and the surrounds.
During the inspection ot her areas of damage were obs erved
throughout the dwelling. Cracking was observed through the
plasterboard walls and ceilings in many locations. However, close
insp ection at eac h location found that each of the cracks
presented chipped and stained edges consistent with damage that
had occurred many years prior to recent events.
Furthermore, the cracks were locat ed all throughout the dwelling.
Typically, cacking caus es by a plumbing leak is contained to a
localised area within close proximity to the leak. This is also known
as a zone of influence. Damage was noted all throughout the
dwelling and was not contained to a zone of influence .
The insured advised that there were concerns in relation to mould
growth throughout the dwelling. The inspection observed mould
across the cornice in the front bedroom. It was noted that while
mould was evident in this location, it was more significant at the
front corner of the dwellin g than it was at the location of the leak in
the bathroom. There was also minimal mould growth in the
hallway and rooms surrounding this location. The obs erved mould
growth did not appear to be consistent with mould caused by the
recent plumbing leak.
Fur ther inspection throughout the interior observed cracks that had
been previously patched and painted. Patching was observed all
throughout the dwelling. Some of the patched locations had since
re - cracked. It was also observed that the bottom of the front e ntry
door was damaged and had been planed off. The insured advised
that the door had been misaligning for many years causing it to
Determination | Case number: 710755 Page 14 of 21
Record Key points
catch at the bottom. The inspection noted that these damages
were consistent with damages that had occurred many years prior.
The damages were also consistent with damages often attributed
to long - t erm foundation movement.
The inspection conducted through the kitchen and meals room
areas noted the bubbling of paint as well as poorly repaired
cornices and walls. The evidence sug gested that repairs were not
effectively conducted in this location following the reporting of the
damages not ed in the 2016 claim.
An inspection of the subfloor was conducted through the floor
hatch in the bedroom wardrobe. The inspection noted that the
subfloor soil below the hatch was very wet. Elsewhere throughout
the subfloor excessive moisture was also apparent.
An inspection of the dwelling exterior was then conducted. The
inspection observed that the roof’s tiled hips had been re - bedded
and re - poin t ed. The bedding and pointing however, was not
repaired to a professional standard or a tradesman - like manner.
The insured advised the previously - det eriorate valley iron and
guttering had been replaced.
Further inspection of the exterior observed many iss ues. The
downpipes on the left of the dwelling had been redirected to
above - ground plumbing lines. The stormwater is then
concentrated to an area in the front yard. This attempt to repair the
dwelling’s stormwater system indicates a significant pre - existin g
plumbing issue. The evidence indicates that significant amounts of
water have leaked from the stormwater line into the subfloor prior
to this repair being attempted.
Furthermore, the October 2019 Bay & Beyond plumbing report
also indicated that a drain a t the rear of the property remains
connected into this damaged stormwater line. It is likely that this is
the source of the continued and significant moisture issue in the
subfloor.
In addition to the redirected plumbing line, efforts have been made
to co ntrol the flow of water from the backyard into the subfloor.
The inspection noted that a crudely laid line of concrete had been
installed on the pathway across the rear of the dwelling. This
appears to be an attempt to prevent excessive wat er from flowing
into the subfloor from the rear of the property. This repair attempt
indicates a pre - existing and long - term subfloor moisture issue.
The evidence suggests that long - term and ongoing stormwat er
and site drainage issues have caused a significant amount of
water to build up under the dwelling over many years. The
excessive moisture throughout the subfloor indicates that previous
rectification attempts remain ineffective.
An inspection of the brickwork observed step cracking on both the
left and right sides of the dwelling. The presence of step cracking
may indicate that a dwelling has sustained structural movement
from the foundation level.
Close inspection of the cracking on the right side of the dwelling
revealed that the cracks presented smoothed and sta ined edges
Determination | Case number: 710755 Page 15 of 21
Record Key points
consistent with damage that had occurred many years prior.
The inspection of the cracking through the left side brickwork
revealed that the cracking had been patched at a time prior to
recent events. The patched step cracking had re - cracked due to
this ineffective method of repair.
Separation was also observed bet ween the brick wall and the
carport beam at the rear right corner of the dwelling indicating
differential movement between the carport and dwelling. The
evidence therefore suggests tha t foundation movement have
occurred for many years prior to recent events.
During the inspection the insured also advised of the movement or
separation of the middle control joint in the concret e driveway
beside the dwelling. This was not considered a sig nificant issue; it
does however indicate the likelihood that significant long - term
moisture issues have caused the movement of the founding soils
throughout the property.
The evidence suggested that the dwelling may have sustained
movement - related crackin g prior to the recent leak incident.
Further investigation was therefore required to det ermine whether
the observed cracking and separation was related to the recent
leak incident or whether it was caused by a long - term foundation
movement issue.
Further assessment of the foundation was therefore conducted
The results of the hydraulic level survey indicated significant and
wides pread foundation movement all throughout the dwelling. The
location at which the gross movement was most significant was in
the lo unge room, however areas of significant variance were
detected all through the dwelling.
The difference in floor level across the dwelling was greater than
50mm. The greatest level variance was detected bet ween the rear
sunroom and front lounge room. The flooring height in the front
right corner of the lounge room was approximately 54mm lower
than the highest recorded level. This was a similar level variance
to the flooring at the front left corner of bedroom 1 which was
54mm lower than the highest recorde d level.
When a leak occurs, it increases the moisture content of the soil
surrounding the leak location. In a reactive site the clay particles
react by chemically absorbing wat er into the matrix of the particle.
The absorption of the water int o the clay p article results in an
increase in volume of the particle – the soil swells.
In reactive foundation soils a moisture - related volume increase will
cause a localised ex pansion can occur. This is referred to as a
doming effect. The extent of the expansion dim inishes over
distance away from the broken pipe. When reviewing contour
surveys, you may see the contours radiating out from the location
of the break in the pipe. The high point is detected close to the
break in the pipe where the expansion is the great es t.
In this case however, the contours at the bathroom on the level
survey mud map did not indicate a localised expansion. There is
no evident doming in this location.
Determination | Case number: 710755 Page 16 of 21
Record Key points
An area of raised or expanded reactive soil foundation is observed
when a leak impacts reactive founding soils. The evidence of the
cause of damage is therefore not consistent with a recent leak
from the bat hroom plumbing line.
This available evidence indicates that the foundation movement
was not consistent with movement that has occurred as a res ult of
a recent escape of liquid from the bathroom plumbing line.
The contours of the level survey indicate that localised subsidenc e
has occurred in many areas of the dwelling. The level survey
contours have detected areas of subsidence in these locations
rather than the doming observed in zone of influence at the leak
location.
The foundation movement in the loc ations outside of the zone of
influence was attributed to poor foundation performance over a
prolonged period. These areas foundation mov ement can be
attributed to the following factors.
The Cause of the Foundation Movement
The cause of the movement is attributed to a number of factors:
1. Subgrade Movement – The soil in this area is mainly a clay -
based soil which was estimated to have a site classification of S to
H. Variation in the strength and content of the soil occurs in this
area, hence some element of soil can provide a greater load
bearing pressure t han others. With the construction of the building,
additional weight is placed on the soil. This additional weight
results in consolidation of the soil and over time, the soil settles
under the weight.
The majority of this type of movement occurs in the f irst ten years
following construction. After the consolidation occurs, further gross
movement due to this effect dramatically diminishes. Subsoil
movement is considered to be the main cause of the observed
differential foundation movement.
2. Soil Type – The soil in this area is noted as being reactive. With
cycling of moisture content, variations in volume of the soil occur.
If the footings are not adequately constructed this variation in soil
volume can result in movement of the footings. This is particu larly
noticeable in the first three to seven years following construction.
As this may occur unevenly, cracking and movement of the
dwelling can occur.
3. Environmental Conditions – The type of soil on which the
house is constructed is subject to swelling and shrinkage,
dependent upon the amount of rainfall. Loss of moisture over
depth has resulted in volumetric change in the soil, i.e. the soil
shrinks and, as a result, foundational support is lost.
4. Site Drainage – Water can run under the subfloor are a and can
pond/build - up against stump footings - uneven wetting of founding
soils can cause unequal compression of founding soils and
possible building movement.
5. Plumbing Lines - A PVC stormwater line has been installed
above the ground along the west side of the property. The new
stormwat er line is not adequately supported and discharges water
Determination | Case number: 710755 Page 17 of 21
Record Key points
to the surface of the garden at the front of the dwelling. The
original earthenware plumbing lines that the new PVC lines
replace are still visible and filled wi th debris. This indicates that
significant pre - existing plumbing issues have not been suitably
repaired.
Furthermore, a drain at the rear of the property was found to be
still connected to the original disconnected and damaged
stormwat er line. Water from the rear of the property is therefore
channelled to the damaged plumbing lines around the dwelling
during rainfall events.
Additionally, damage to the sewer line bet ween the toilet and
kitchen was identified. A non - compliant plumbing line has been
install ed to extend the rear gully outlet to below the rear dwelling
extension. Water from the bathroom and laundry fixtures appeared
to be discharging under the dwelling extension via the gully. Water
pooling in the subfloor was likely to have occurred due to a
blockage.
It is noted that the subfloor is uncharacteristically very wet and
muddy. Each of these pre - existing plumbing issue appear to be
contributing to the ongoing and long - term build - up of excessive
moisture throughout the subfloor. The repeated and constant
uneven wetting of founding soils is likely to cause the movement of
founding soils and building movement.
The results of the hydraulic level survey detected widespread
foundation movement consistent with pre - existing, long - term
issues that have ca used differential movement and damage all
throughout of the structure.
It is recommended that the insured engages a suitable structural
engineer to further analyse the dwelling, monitor its movement and
design an adequate design solution for rectification of the damage
attributed to the significant differential movement throughout the
dwelling.
It is also recommended that the insured engages a suitable
plumbing specialist be engaged to repair and correct the many
significant plumbing issues around the dw elling including the
repair of the stormwater, sewer and site drainage issues.
It is important to not e that the soil in the subfloor currently remains
saturated. The soil will dry out over the 12 months following the
repair of the plumbing lines and durin g this time the structure is
likely to settle back down into its resting position. Further cracking
may occur through the linings such as the floor tiles and
plasterboard walls as the dwelling settles. It is therefore
recommended that the insured delays ae sthetic repairs until after
this time.
CONCLUSION
An engineering investigation of the dwelling was conducted
following the discovery of several significant structural issues to
the dwelling including foundation and roofing damage. There were
concerns that a recent plumbing leak may have contributed to the
damages.
Determination | Case number: 710755 Page 18 of 21
Record Key points
In order to determine the condition of the dwelling and the cause
of the damage, a review of past reports was conducted as well as
a visual inspection and a hydraulic level survey. Further
inves tigation was conducted to separate pre - existing damages
from those that may have been attributed to the recent plumbing
leak in the subfloor below the bathroom.
The available evidence indicates that the foundation of the
dwelling has subsided over a prolo nged period causing differential
movement throughout the structure. The build - up of stresses
through the structure has caused cracking and separation of the
interior and exterior.
The investigation found that the damage was not consistent with
damage caus ed by a plumbing leak but was consistent with poor
foundation performance over many years. The evidence indicates
that the movement is a long - term issue caused by several
contributing factors listed in the body of this report.
It is recommended that the i nsured engages a suitable structural
engineer to further analyse the dwelling, monitor its movement and
design an adequate design solution for rectification of the damage
attributed to the significant differential movement throughout the
dwelling.
It is r ecommended that the insured engages a suitable plumbing
specialist to repair and correct the many significant plumbing
issues around the dwelling including the repair of the stormwater,
sewer and site drainage issues.
It is also recommended that the insur ed employs a 6 - 12 month
dry out period following the repair of the plumbing issues prior to
the commencement of aesthetic repairs due to the current
saturated condition of the founding soils.
It should also be noted that proper site drainage be maintain ed at
all times, so as to prevent any surface water ponding or laying
near the foundations of the building.
The attached appendices A, B & C have been supplied to provide
further information regarding the assessment of foundation
performance, the classifi cation of damage and effective foundation
maintenance.
Insurer Builder (A1)
Report
9 June 2019
Due to the recent heavy storm events that have passed in the area
of the Insured’s property, the Insured had advised wat er has
leaked through the kitchen and bedroom areas. As a result there is
a small water stain affecting the kitchen ceiling close the entry to
the living room. The paint is slightly
bubbling to the top right - hand side corner of the a rchitraves in the
living room opening as well.
- Inspection of the roof directly above the affected rooms found
that the pointing under the valley tiles
was cracked and allowing water to leak through. The valley iron
directly above had rusted under the
til es and was allowing water to enter and damage the ceilings
below. The valley iron requires
Determination | Case number: 710755 Page 19 of 21
Record Key points
replacement prior to repairs proceeding.
- Pre - existing damage and patch up work was noticed to the
ceiling plaster joins and a crack along the
wall join directly be low. It appears to the patch up was to a crack in
the ceiling and the wall crack was
a result of the house movement, and not moisture from the recent
event. The floor level beneath felt
uneven which also confirmed movement of the foundations.
- Inspection to the bedroom revealed water marks to the walls
where the water was entering from
under the cornice. The patch up to the wall plaster join along the
affected wall was finished uneven
and not from the effects of the event.
- Further inspection of the roof directly above revealed the gutters
were rec ently cleared as the drain
had become blocked causing the water to overflow into the eaves
and into the bedroom. No roof tile
damage was visible above the affected area.
- Other maintenance issues to the roof inc luded the remaining roof
area had visible cracking to the
pointing under the ridge/hip capping tiles and roof valleys.
Debris was present within the gutters.
- The pointing under the valley tiles was cracked and allowing
water to enter. The valley iron dir ectly
above had rusted under the tile and was allowing water to enter
into the roof space to cause water
damage to the kitchen/meals area. The valley iron will need to be
replaced to prevent furt her water
ingress.
- The remaining roof wit h the cracking of the pointing under the
ridge/hip capping tiles and valleys
will lead to water ingress in the fut ure if not attended to.
Refer to insurer/ Due to maintenance issues with the roof. The
Insured’s policy excess if far higher than the estimated repair cost,
the refore the Ins ured may wish to withdraw their claim.
Insurer Plumber (DPR)
Report
25 October 2016
The roof has been observed to be approximately 25 years old
During our detailed inspection of the roof area we found that the
roof was in good condition
We envisage the overall life expectancy of the existing roof, not
taking into consideration insurance related damage to be 15+
years
Issues to the family home have come from several areas over the
roof. First area was on the tile roof next to the skylight, wh ere a
broken tile was staining the hallway ceiling. Second issue was
over the kitchen area, where the tiles next to the valley have been
silicone, creating issues around that area. The valley itself has
rust. Third issue was the breakdown of the heater flu e cowl and
decktite on the metal roof. Water has entered over the sunroom
causing water problems. Fourth area in the bedroom we could not
Determination | Case number: 710755 Page 20 of 21
Record Key points
find water stains on the plaster inside of roof space. No issues on
the roof above. The crack may have come from movem ent over
time.
Overall the roof appears to be compliant to relevant Australia
Standards
Issues to the family home have come from several areas over the
roof. First area was on the tile roof next to the skylight, where a
broken tile was staining the hallway ceiling. Replacing tiles around
the hallway area is required. Second issue was over the kitchen
area, where the tiles next to the valley have been silicone, creating
issues around that area. The valley itself has rust. Valley to be
replaced due to rust an d tiles that have been silicone to be
replaced over kitchen area. Third issue was the breakdown of the
heater flue cowl and decktite on the metal roof. Replacing dec k tite
and replace rusted gas cowl is vital. Water has entered over the
sunroom causing wate r problems. Fourth area in the bedroom we
could not find water stains on the plaster inside of roof space. No
issues on the roof above. The crack may have come from
movement over time. Ceiling to be looked at. Addressing these
issues on the roof is recomme nded before works inside of home
Insurer Asse ssor
Report
24 October 2016
On 24/10/2016 we attended the above residenc e in the presence
of Mrs M to ascertain the damages
sustained to the property for the claimed storm.
Mrs M advised that on 17/10/2016 that during the storms her
property was damaged. The Insured wife
claimed that they had lodged storm claim a few months ago. She
then claimed that the insurance company
sent out a person at that time to siliconed the roof tiles, and placed
bags on the roof .
The Insured then stated that no one had turned up to do anything
further to her roof until she called again a
week ago. Insured said that she has owned this property for the
past 9 months and that the property is approx.
55 years old. Insureds wife expla ined that she notes that water
runs down the walls in the master bedroom
mainly the bed head wall. We have found that the roof report
indicated no water entry to this room. This
would be condensation rather than wat er leaking.
The roof report indicated tha t the roof has leaking issues, the the
valley rusted, cracked tiles silicone (Mrs
claimed done by insurance company). The hip has dislodged tiles.
Water entry at the rear is non storm related
this is due to a poor heat er flu and boot flashing leaking.
The cause of water entry to this roof area is due to maintenance
required to the insureds roof. No storm
related damage was found to this roof.
LEFT SIDE 1/2 SHARED FENCE
Insured also claimed that this has been damaged due to the
recent strong winds.
Determination | Case number: 710755 Page 21 of 21
Record Key points
We have f ound that the fence is leaning and loose not damaged
due to recent storms requires also some
maintenance repairs to be done.
Yes as the roof report attached indicates many areas need repairs
Upon inspection of the residence there was found to be damages
su stained to the as scoped internal minor
painting
Roof is maintenance related
As scoped
3.4 Other documentation
Insurer’s assessor reported dated 20 December 2019
FR Mould Remediation Scope of Works 31 December 2019
TRU underpinning quote 20 February 2020
JLG Scope of works 25 October 2016.
Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.