Home / Youi / Determination 701813

Determination 701813

Bathroom water damage declined under shower-leak exclusion; claims handling

FirmYoui
Decided2021-02-18
ProductGeneral Insurance · Home building and contents
OutcomeFor the complainant in part
Amount awarded—
Non-financial loss$500
Amount claimed—
SourceAFCA PDF

Summary

A home insurer declined bathroom water damage under the shower-leak exclusion, and the complainant argued a cold-water pipe leak contributed. AFCA upheld the decline but ordered $500 compensation because the insurer initially refused an acoustic leak test.

The insurer proved the damage came from an excluded shower leak, and the complainant did not establish a pipe leak, but poor claims management justified non-financial loss compensation.

Issues

Subjects and remedies

home or building damagepay non financial loss

Related

All Youi determinations · Find similar determinations

Text of the determination

Determination Case number 701813 Financial firm Youi Pty Ltd Determination | Case number: 701813 Page 2 of 10 Case number: 701813 29 January 2021 1 Determination overview 1.1 Complaint The complainant holds a home and contents insurance policy with the financial firm (insurer). The complainant lodged a claim for water damage to the bathroom. The insurer says the cause of damage is a long -term water leak from the shower cubicle which is excluded from cover. The complainant disputes the insurer’s decision and says a leak in the cold-water line could have contributed to the damage to the bathroom and is seeking cover for the bathroom repairs and compensation for non-financial loss due to stress and inconvenience. The case analyst provided the parties with a recommendation on the issues in dispute. The recommendation was in mostly in favour of the insurer. As the recommendation was not accepted by the complainant, the complaint has been referred to me for determination . 1.2 Issues and key findings Is the insurer entitled to decline the claim for property damage? Yes. The available information establishes on the balance of probabilities the damage was caused by water escaping from a leaking shower. As this cause of damage is excluded from cover the insurer is entitled to decline the claim. Is the complainant entitled to compensation? Yes. The available information establishes the insurer’s claims handling would have interfered with the complainant’s expectation of enjoyment or peace of mind. 1.3 Determination This determination is partially in favour of the insurer. Should the complainant accept this determination, then within seven days of notification of acceptance, the insurer is to pay to the complainant $500 compensation. Determination | Case number: 701813 Page 3 of 10 2 Reasons for determination I have decided this complaint based on what is fair in all the circumstances, having regard to legal principles, applicable industry codes or guidance, good industry practice and previous relevant determinations of AFCA or predecessor schemes (which are not binding). I have considered all the material submitted by the parties, both before and after the recommendation. I am satisfied that the documentation I have relied on has been provided to both parties. While the parties have raised numerous issues in their submissions, for the purposes of this determination, commentary has been restricted to those issues considered directly relevant to the outcome only. After the recommendation was rejected, the complainant essentially reiterated her position, made no further submissions and provided no new material. 2.1 Is the insurer entitled to decline the claim for property damage? Complainant has established a valid claim The complainant must establish on the balance of probabilities she has suffered a loss caused by an event to which the policy responds. This is known as a prima facie or valid claim. In the context of this claim the complainant must establish damage to the bathroom was caused by escaping water which occurred suddenly and without warning or slowly over a period and she could not have been reasonably aware of it. The relevant policy terms are set out in supporting section 3.3 this determination. A builder and two plumbers inspected the damage not long after the claim was made. A summary of expert material is set out in supporting section 3.2 of this determi nation. The available evidence indicates the escaping water occurred slowly over time. The complainant says she was not aware of the escaping water until the claim was made. On the available evidence, I accept the complainant was not reasonably aware of t he escaping water causing damage. I am satisfied the complainant has established a valid claim. Material from parties considered Once so established, the onus shifts to the insurer to prove on the balance of probabilities that an exclusion applies if it seeks to deny or limit its liability for the loss. There are two exclusions. The insurer does not rely on the first exclusion: that is, the complainant was reasonably aware of damage caused by water escaping slowly over a period. Determination | Case number: 701813 Page 4 of 10 The insurer must establish on the balance of probabilities the damage was caused by water escaping from a leak in the shower base, recess or cubicle. The insurer’s builder first inspected the damage on 6 January 2020. He noted damage to the floor tiles and timber flooring. Because of waterproofing issues, the bathroom needed to be replaced. The builder reported the floor tiles were damaged by water seeping from the shower recess through deterioration of wall tiled grout joints, deterioration to the seala nt to the recess and shower screen and failure of the waterproofing membrane. Two days later, employing a spray test and thermal imaging, the insurer’s plumber confirmed water was leaking into the wall at the front left corner of the shower and between the bottom of the shower screen and shower base which spread across the subfloor. He identified several deteriorated seals in the shower recess. On 11 February 2020 the complainant’s plumber made similar findings. He said the shower screen was in poor condition and when he conducted a splash test, the right- hand side leaked immediately. He identified that water was leaking from the shower screen on both the left and right sides, from the shower base and along the bottom of the shower. He said the leaks had been occurring for several months. The complainant does not dispute the bathroom was damaged by water leaking from the shower base, recess or cubicle. The complainant argues the damage to the bathroom has also been caused by a leaking pipe. This is because the complainant’s plumber conducted a water pressure test on the cold line which failed. The plumber also said that until he knew where the water leak is on the cold line he could not rule out that as a contributing factor to the damage to the bathroom floor. He recommended an acoustic leak detection test to determine the location of the water leak on the cold-water line. This finding was different to the insurer’s plumber. He conducted a pressure test between the shower rose and the shower breach and said there was no loss of pressure over five minutes. He said there were no leaks in the wall between the rose and the breach. The acoustic leak detection test did not occur. The complainant says:  the insurer rejected the need for acoustic testing based only on an opinion  the claim process took too long, and they needed to repair the bathroom, so the acoustic leak detection test did not later occur  the method used by the insurer’s plumber to test water pressure was inadequate Determination | Case number: 701813 Page 5 of 10  the test did not get any other information about any other pipe leak and so was unreliable  when she repaired the bathroom, there was a lot of water damage which is not possible from shower use which is minimal. The insurer says:  an acoustic test was not required as it had sufficient information to make its claims decision  an acoustic test was offered in good faith in the IDR letter, but the complainant did not want to proceed with the test as she did not want to extend the dispute due date  there is no evidence of a leaking pipe  water bills may have a variance, but they do not confirm a leaking pipe in the bathroom. Policy exclusion established by insurer I have considered all the available material including photographs provided. I am satisfied the available evidence establishes on the balance of probabilities the claimed damage was caused by water escaping from a leak in the shower base, recess or cubicle. I am satisfied the insurer is entitled to decline the claim. Complainant has not established leaking pipe contributed to the damage The complainant bears the onus to establish on the balance of probabilities a leaking pipe contributed to the damage. The reports and photographs provided are insufficient to meet this onus. Firstly, I did not accept the available evidence establishes the insurer’s plumber’s testing was inadequate. The report is comprehensive, and the photographs provided support his contentions. Secondly, the complainant’s plumber’s report is insufficiently persuasive. While he identifies an issue in the cold-water line he does not know where the water leak is. While acoustic leak detection test may have assisted, the onus rests with the complainant to provide persuasive independent objective material that if there was a leak in the cold-water line it was in the bathroom and caused or contributed to the claimed damage. The material provided is insufficiently comprehensive and persuasive. Thirdly, while I have reviewed the material from her contractors, the va riance in water bills and the damage which was seen when the bathroom was demolished on 25 February 2020, this does not establish a leaking pipe in the bathroom probably caused the claimed damage. Moreover, the available evidence establishes the shower was leaking for several months. Determination | Case number: 701813 Page 6 of 10 In all the circumstances, for the reasons stated, I am satisfied the insurer is entitled to decline the claim based on the policy exclusion relied on. 2.2 Is the complainant entitled to compensation? AFCA may award compensation in some circumstances The complainant complains about the way her claim was handled. She is aggrieved because initially the insurer did not agree to pay for the acoustic testing. The insurer says it did not believe that an acoustic test was required as the leak was investigated and excluded under the policy. It later offered to make further inquiries as to why the pressure had dropped when the complainant’s plumber inspected the damage. AFCA will award compensation (capped at $5,000) if there has been an unusual degree or extent of physical inconvenience, time taken to resolve a complaint or interference with the complainant’s expectation of enjoyment or peace of mind. AFCA takes a conservative approach to awarding compensation. We do not award compensation because the complainant has suffered some inconvenience and anxiety. AFCA expects complainants to be moderately robust and to bear the normal degree of inconvenience experienced when a problem occurs and to take reasonable steps to manage the situation. Fair the insurer pays $500 compensation I have considered all the available information including the claim file notes. I have listened to the call recording. The claim was made on 31 December 2019, a builder and a plumber inspected the property and the claim was declined on 15 January 2020. The decline was confirmed in its final decision letter on 13 March 2020. I am satisfied the claim was dealt with in a timely fashion. Although the insurer initially refused to conduct an acoustic test, it later changed its position. By this time, the complainant had commenced repairs. I acknowledge the material relied on by the insurer to take the position it did, but I consider good claims management and customer service would have led to an agreement to the re quest particularly in complainant’s family circumstances. The claim notes show the insurer paid the complainant for the cost of her report in the sum of $242. It was not required to make this payment. I am satisfied an award of compensation of $500 is fair in the circumstances. Determination | Case number: 701813 Page 7 of 10 3 Supporting information 3.1 Our Approach It is an accepted principle of general insurance law that the insured bears the onus to establish on the balance of probabilities that they have suffered a loss caused by an event to which the policy responds. This is known as a prima facie or valid claim. Once so established, the onus shifts to the insurer to prove on the balance of probabilities that an exclusion applies if it seeks to deny or limit its liability for the loss. 3.2 Key expert material and findings Record Key points Insurers builder (A) Report 6 January 2020  Damage to floor tiles and timber flooring. Bathroom needs to be replaced.  Floor tiles damaged by water seeping from the shower recess through deterioration of wall tile d grout joints, deterioration to sealant to the recess and shower screen, and from failure of the waterproofing membrane.  Damages are maintenance related due to gradual deterioration and indicative of long - term water expos ure having occurred slowly and would have been reasonably noticeable.  Damages are not from a sudden and unexpected escape of water from a single event. In surer’s plumber (S) Report 8 January 2020  Tested and inspected 8 January 2020 and found large extent of damage to the subfloor in the bathroom. Make safe team appointed and installed a sheet of ply wood across the floor.  Tested shower to see if possible l eak from the shower is causing damage. Conducted a pressure test between shower rose and shower breach. No loss of pressure over five minutes. Therefore, no leaks in the wall between the rose and the breach.  Inspected shower seals and found the grout lines and silicon seals have started to deteriorate and wat er is leaking through the cracks and gaps. Tested the seals by conducting a spray test. Used a thermal imaging camera and found clear evidence of water leaking into the wall at the front left corner of the shower.  Water leaked through between the bottom of the shower screen and the shower base which spread across the subfloor.  Tested toilet, water and waste connections and found them in good condition and watertight.  D amage has been caused by the show er as d ue to several deteriorated seals between the wall tiles and along the recess, water is able to leak through the deteriorated seals into the wall. Determination | Case number: 701813 Page 8 of 10 Record Key points  W ater has then spread across the subfloor, causing part of the damage.  F urther damage is being caused by water leaking through between the shower screen and the shower base, as this has not been sealed correctly. W ater can easily leak through the seal and pool along the subfloor, which would be another contributing factor.  Recommend entire shower is re - waterproofed to ensure it is completely watertight. Remove and replace silicone seals between the shower base and shower screen to ensure wat ertight. Complainant’s plumber (T) Report 11 February 2020  A water pressure test pa ssed on the hot line but failed on the cold.  Couldn’t test shower or bath breach. Shower waste, bath and basin draining properly and toilet flushing properly.  Shower screen is in poor condition. Splash test on right side leaked immediat ely.  Tested walls in shower and water leaked from both corners at the point of the screen joins the tiles.  Shower wall with taps – water leaking from nut which is leaking into shower recess.  Shower base is in poor condition. Silicone along the edges has gaps and is allowin g water to leak out of the shower rec ess.  Shower base – failed - wat er leaked from the front and side of the shower.  Water is leaking from the shower screen on both the left and right sides. Water is also leaking from the shower base.  O wner advis ed that they put their foot through the floor in the bat hroom next to the shower. Since then they have noticed wat er damaged to the floor around the shower.  Leak has been occurring for several months.  Damage caused by: A water pressure test passed on the hot lin e but failed on the cold. It dropped from 500kpa to 0kpa in 3min. Water is leaking from the shower screen on both the left and right sides. Water is also leaking from the shower base. Silicone seal along the bottom of the shower is faulty and is allowing w ater to leak from the base. Until we know where the water leak is on the cold line we can’t rule that out as a contributing factor to the damaged caused to the bathroom floor. Both the shower breach and the bath breach are external to the bathroom walls, so we didn’t need to complet e a pressure test. Shower nut on breac h had a small leak but this wouldn’t be a factor in the bathroom damage.  Recommend that an acoustic leak detection be completed to determine the location of the water leak on the cold line a nd that the shower Determination | Case number: 701813 Page 9 of 10 Record Key points recess be reconstructed and resealed. Complainant’s plumber (NP) Invoice 28 June 2020  Found leaking / losing pressure upon removal of floor.  Found deterioration and damage of existing cooper pipes causing subfloor damage to joist and bearers.  Work included removal and renew hot and cold - water copper pipes throughout the entire bathroom to rectify leaking pipes and make good Complainant’s builder (CD) Report 4 August 2020  Commenced demolition of bathroom 25 February 2020. Subfloor bet ween toilet and shower base had collapsed due to water damage.  Upon removal of floor tiles, m ore than three quarters of the existing subfloor between the wall of the shower base and the wall where the existing hand basin was situated had significant water damage.  Y ellow tongue subfloor was completed soaked/ rotten and swelling, the smell of rotting timber was extreme. 3.3 Policy wording Record Key points Product Di sclosure Statement Page 13 8. Escaping Water What is covered? Loss or damage to the insured property caused by escaping water that occurred:  suddenly and without warning; or  slowly over a period of time and you could not have been reasonably aware of it. If you have home buildings cover the most we will pay after excess is $7,500 in total for all buildings damage th at occurs in a contract period. I f a building claim is accepted, we will pay the reasonable cost to find the source of the escaping water. This cost is based on using the most appropriate method to find the source and we will also rest ore the damage caus ed while doing so. What is not covered? Determination | Case number: 701813 Page 10 of 10 Record Key points Loss, damage or legal liability which was:  caused by water escaping: o slowly over a period of time and you could reasonably have been aware of it; o from a leak in a shower bas e, recess or cubicle … 3.4 Other relevant material considered and relied on  Parties’ submissions/emails and all attachments to all submissions/emails both before and after the recommendation  Parties’ expert reports  Photographs, invoices and quotes  Water bills  Call recording  Correspondence between the parties

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.