Home / Allianz Australia / Determination 698721
Determination 698721
Declined cracking and sloping damage to tenanted home
Summary
The landlord claimed for cracking and floor slope damage to a tenanted home and the insurer declined most of it. AFCA found most damage pre-dated the policy or resulted from excluded wear and tear, but ordered the insurer to pay the accepted kitchen/laundry repair amount of about $9,500.
Under the listed events policy, damage that began before inception or results from gradual deterioration and wear and tear is excluded.
Issues
- Claim denial primary · not upheld“the damage has been gradually occurring over an extended period of time that dates to before the policy was incepted”
- Inadequate claim investigation secondary · not upheld“The complainant has not provided any evidence to dispute this opinion”
Subjects and remedies
home or building damagepay claim
Related
All Allianz Australia determinations · Find similar determinations
Text of the determination
Determination
Case number 698721
Financial firm Allianz Australia Insurance Limited
Determination | Case number: 698721 Page 2 of 11
Case number: 698721 13 November 2020
1 Determination overview
1.1 Complaint
The complainant holds a landlord insurance policy (policy) with the financial firm
(insurer), covering a tenanted property. On 30 September 2019, the complainant
lodged a claim for damage to the insured home in the form of cracking damage to
walls and ceilings as well as a slope in flooring levels.
The insurer, having completed its investigation into the damage claimed, has
accepted to cover some of the damage whilst rejecting a majority of the damage on
the basis it was not caused by an insured event within the period of insurance. The
complainant remains dissatisfied with the insurer‟s assessment of its liability under the
claim.
1.2 Issues and key findings
Is the insurer entitled to limit its liability under the claim in line with the policy?
The policy is a listed events policy subject to several specific exclusions. I am
satisfied, other than the damage to the kitchen/laundry area which has been accepted
under the claim, the insurer is entitled to decline cover for the remaining damage. I
am satisfied the proximate cause of the remaining damage was due to circumstances
clearly excluded from cover under the policy.
1.3 Determination
This determination is in favour of the insurer.
The insurer is entitled to decline cover for the damage to the insured building it has
assessed to be excluded from cover in line with the policy provisions specified in the
product disclosure statement (PDS).
Determination | Case number: 698721 Page 3 of 11
2 Reasons for determination
I have decided this case based on what is fair in all the circumstances, having regard
to the relevant legal principles, good industry practice, industry codes of practice and
previous relevant decisions of AFCA or predecessor schemes.
I have considered all the material submitted by the parties both, before and after the
recommendation. I am satisfied the documentation I have relied on has been provided
to both parties for their consideration and comment.
2.1 Is the insurer entitled to limit its liability under the claim?
The policy covers loss or damage caused by the listed insured events
The policy covers direct or indirect loss or damage to the insured property caused by
one or more of the listed insured events, within the period of insurance. Cover for
such loss or damage is subject to the limitations and exclusions specified in the PDS.
The PDS provides a clear list of events/circumstances, which if result in loss or
damage to the insured property, triggers cover under the policy. This includes loss or
damage which may occur due to an escape or leaking of water (liquid).
The policy is subject to the limitations and exclusions specified in the PDS
Cover for loss or damage to the insured property, even if shown to have been the
result of circumstances covered under the policy, remains subject to the limitations
and exclusions specified in the PDS.
Relevant to this complaint, the policy excludes from cover loss or damage which:
occurs outside the period of insurance e.g. occurs or has been occurring since
before inception of the policy
is not caused directly or indirectly by a listed insured e vent
occurs due to wear, tear, gradual deterioration or depreciation.
2.2 Is the insurer entitled to decline the complainant’s claim ?
The insurer has accepted to cover part of the damage claimed
There is no dispute, on the advice of the consultants appointed by the insurer to
investigate the cause and extent of the damage claimed, that it has accepted to cover
some of the damage noted in the kitchen/laundry area of the property. The insurer
says, in good faith, it accepts that some of this damage is due to the leaking kitchen
waste under the slab, which caused heave of the foundation soils in this area.
I note the cost to repair this damage was quoted to be around $9,500. I also note,
after receiving a supplementary report from appointed engineers „IM‟ dated 4 August
Determination | Case number: 698721 Page 4 of 11
2020, the insurer commented that it may consider withdrawing the offer to accept to
cover this portion of repairs to the kitchen/laundry area.
However, I am not satisfied it was confirmed, to the complainant or AFCA, that the
offer had been withdrawn. Without such confirmation from the insurer, I am satisfied
the offer remains open and is fair in the circumstances.
AFCA has not been provided with a detailed scope of works for these repairs, other
than the quoted estimate of $9,500. The available information says it is possible the
leak in the laundry waste caused a heave of the footings around the laundry/kitchen
which contributed to some of the cracking in these rooms.
Therefore, within 14 days of the complainant accepting the determination, the insurer
is to arrange for the above noted payment to be made to the complainant or
alternatively, arrange for the said repairs to be completed.
The complainant says claimed damage occurred after he bought the property
The complainant says the property sustained significant cracking damage including
sloping of the floor because of an escape of water from damaged/leaking stormwater
pipes. The complainant says none of the below issues were present at the time he
purchased the insured property in April 2015:
cracking of the cornices
cracking of ceiling and walls
hallway door not closing
failure of the roof trusses by way of nailplate backout.
The property was tenanted, and the sloping floor issue was not brought to his
attention until July 2017.
The damage has been present and/or increasing from before policy inception
I am satisfied the insurer has established, on balance, the damage to the insured
property (other than that accepted under the claim) is not directly or indirectly related
to an insured event.
The insurer appointed loss adjusters „C, plumber „PP‟ and engineers IM. The
complainant has not provided any expert evidence. He advised that a plumber was
initially appointed, however, that this plumber did not provide a report and given the
extent of damage noted, he recommended the complainant to lodge a claim under the
policy.
The complainant, despite requests from the insurer and AFCA, has not made
available a pre-purchase building inspection report for the insured property.
Determination | Case number: 698721 Page 5 of 11
PP confirmed there were many issues relating to the home‟s stormwater and waste
pipes. It noted all the waste pipes at the rear of the home had sheared off and were
leaking into the soil between the rear pavement and wall each time they were used.
IM acknowledged this, however, says that there is no evidence of localised footing
heave that would be expected if the leaks had contributed to the damage to the
insured building. Other than the damage in the kitchen/laundry area which has been
accepted, IM considered the damage to the property was not caused by the leaks.
IM says movement of the building has been an ongoing problem for the property with
the home being in a distorted shape for an extended period of time due to seasonal
and environmental influences. It says this is also reflected in the internal floor levels
survey, which shows a planar type tilt down towards the southern (front) side of the
house.
IM says the shearing of the pipes at the rear of the insured building was the result of
the long-term tilt of the home supported by the gap between the wall and rear
pavement. The pipes shearing was the result of the movement as opposed to the
leaking pipes being the cause of movement and associated damage to the pipes.
IM reiterates that the brick course levels survey does not show a heave pattern of
movement, which is what it would expect to observe if the leaks had caused the
damage. In IM‟s opinion, the pattern is consistent with a drying sett lement towards the
home‟s front
The overall slant/sloping reported in the inspection reports has been dominantly
caused by the same settlement mechanism described with regards to the
superstructure. IM acknowledges this is the primary area of concern fo r the
complainant, however, the slope is towards the south-western corner, which is also
the area that IM believes has suffered from the most severe settlement.
IM says, although the differential footing movement may only have recently been
noted by the property manager/complainant, this is a process that does not occur
suddenly. Rather, it occurs overs over an extended period of time, which IM says is
consistent with the historical photographic data made available for review.
These pictures show presence of movement damage at the insured property at the
time it was advertised for sale in 2015.The images span from 2011 to 2015 and
establish, on balance, the movement of the building had been ongoing for a long time
including before the complainant purchased the property.
I note this view is further supported by photographic evidence that forms part of the
R‟s ( property manager) routine inspections. I accept refere nce to such damage may
not have been made until 2017, however, the photos show existence of cracking
damage from 2015. On balance, I accept this damage was present before the
complainant purchased the property.
Determination | Case number: 698721 Page 6 of 11
The complainant says no repairs to the insured building were authorised or
undertaken by him relating to these issues discussed above. However, IM found
evidence of, and for which photos have been supplied, showing such repairs had
been previously completed, which therefore on balance occurred before the
complainant purchased the property.
Without evidence to the contrary, I am satisfied, on balance, that the damage has
been gradually occurring over an extended period of time that dates to before the
policy was incepted. Such damage is excluded from cover in line with the policy
provisions.
Damage noted to roof trusses is a separate event and excluded from cover
I am satisfied the damage to the roof trusses did not arise from an insured event but
was most likely due to gradual deterioration and wear and tear.
IM noted that the dimpling and cracking damage to the ceilings was due to their
longitudinal alignment which it says is evidence of poor performance of the roof
framing.
IM found there was evidence of nailplate backout, which is a progressive failure of the
roof trusses due to the nailplates withdrawing from the timber. IM explains that this
occurs when the teeth or nails of the plate are progressively worked out of the timber
because of the expansion and contraction of the timber due to variations in moisture
content.
This has weakened the trusses over time which has resulted in the cracking and
dimpling of the ceiling and cornices.
In IM ‟s opinion, the damage to the ceiling and cornices is unrelated to building
movement because of the reactive foundation soils. Rather, it relates to the failure of
the roof framing.
The complainant has not provided any evidence to dispute this opinion. Based on the
available information, I am not satisfied the damage to the ceiling and cornices is the
result of an insured event. In my view, the damage was caused by wear and tear or
gradual deterioration which is excluded under the policy.
Insurer is entitled to limit its liability
Accordingly, for the reasons considered above, and without information to the
contrary, I determine the insurer is entitled to limit its liability under the terms of the
policy to the damage in the kitchen/laundry area.
Determination | Case number: 698721 Page 7 of 11
3 Supporting information
3.1 AFCA approach to this complaint
This complaint has been determined based on what is fair in all the circumstances,
having regard to the relevant law, good industry practice, codes of practice and
previous decisions of AFCA or its predecessor schemes (which are not binding).
A full exchange of the relevant information has taken place between the respective
parties. Each party has had the opportunity of addressing any issues raised.
All the provided material has been reviewed and considered. The parties have raised
numerous issues in their submissions to AFCA. However, commentary in this
determination is restricted only to those issues considered relevant to the outcome.
3.2 Consultants’ evidence
Record Key points
C 1 st Asse ssment Report site attendance for 1 October 2019
f urther investigation by a plumber and engineer is required.
PP Leak Investigation Report
9 October 2019
visible cracking and movement throughout h ouse
a test of all internal and external mains water pip e work recorded a
static result
n o leaks were detected in the water supply pipework (including
both hot and cold).
n umerous issues were found with the stormwater drainage around
the home (mostly associated with installation issue s that are
readily observable)
a blockage and a separate break were found in the stormwat er
pipe in front of the home‟s south - western corner
a break in the stormwater pipe was found adjacent to the north -
western corner
t he sewer was found to be in poor c ondition, with several breaks
/ misalignments of joints in the earthenware pipework that extends
adjacent to the rear elevation
a ll waste pipes were broken where they exited the rear elevation‟s
footing and before they connected to the main sewer drain. PP
expect these pipes are leaking with each use of the servic es they
drain.
PP believe the laundry waste pipe is leaking beneath the floor
slab.
IM Engineers Report
10 December 2019
attended 5 November 2019
IM provide d the following opinions.
- t he cracking and distortion to this home has been caused by
differential footing movement because of moisture fluctuations i n
the reactive clay foundation
- s easonal and environmental influences are the dominant cause of
Determination | Case number: 698721 Page 8 of 11
Record Key points
the damage causing movement identified in Item 1
- m ovement has been an ongoing problem for this home, and the
home has been in the noted distorted shape f or an extended
period (including prior to the complainant purchasing the home)
- it is possible the kitchen waste leak has contributed to some of the
damage (particularly around the kitchen/laundry)
- IM does n ot believe the other leaks identified have caused
movement to the home (rat her, the lea ks have been caus ed by the
movement)
- t he damage to the ceiling has been caused by progressive failure
of the roof trusses from nailplat e backout and needs urgent
attention
IM Supplementary Report
4 August 2020
JC attended the site on 22 June 2020
carried out a second perimeter brick cours e levels survey
also carried out an internal floor levels survey
o ur position on this matter remains as outlined in IM‟s previous
report. That is :
- the gross movement to the home has been caused by a
long - term sett lement trend towards the home‟s front, and
- it is possible the leak in the laundry waste has caused a
heave of the footings around the laundry / kitchen area,
which has contribut ed to some of the cracking in these
rooms – although IM consider s this possibi lity is less likely
after most recent inspect ion
i n fact, in IM‟s opinion, the front lawn being reported as “dry” and
shown as dry in some of the summer / autumn inspection reports
supports its position that the foundation beneath this home
(particularly at its front) has been subject to considerable seasonal
and environmental changes in soil moisture, which exacerbates
long - term drying settlements.
IM also reiterate that the brick course levels survey does not show
a heave pattern of movement, which is w hat we would expect to
observe if the leaks had caused the damage. In IM‟s opinion, the
pattern is consistent with a drying settlement towards the home‟s
front
this is also believe reflected in the internal floor levels survey,
which shows a planar type ti lt down towards the southern (front)
side of the house.
e vidence obtained during the most recent inspection also indicates
it is less likely that the leak from the laun dry waste has caused any
damage
a review of photos of the crack in the kitchen wall adj acent to the
rangehood (which was one of the cracks that IM considered could
have been caused by the leak) has narrowed since IM‟s original
inspection. In IM‟s opinion, this is evidence that this cracking has
more likely been caused by seasonal and environ mental
influences – not the leak
t he complainant al so advised IM that he had not carried out any
repairs to cracking to the home during his ownership. During IM‟s
Determination | Case number: 698721 Page 9 of 11
Record Key points
most recent inspection, it observed evidence of repairs to cracking
above the laundry door (photo 3 below). Other evidence of past
differential movement to and around the home i s shown in the
photos
d espite the complainant‟s view that the home had not suffered
from at least some form of damage causing differential footing
movement prior to his o wnership, in IM‟s opinion, there is evidenc e
that it had
t herefore, IM maintain s the opinion th at the movement evidenced
in its levels survey has occurred over an extended period of time,
and that differential footing movement has been a long - term
problem for this home
in IM‟s opinion, the overall “slant” reported in the insp ection
reports, and to which it believes is the insured‟s primary concern
with the floor, has been dominantly caused by the same
settlement mechanism described with regards to the
super structure
IM un derstand s the area of primary concern is towards the floor‟s
south - western corner, which is also the area that IM believed has
suffered from the most severe settlemen t A
a ny contribution from the laundry waste (if such a contribution
exists) , would be limited to the area around the laundry and
kitchen, and would not have a noticeable influence on the floor‟s
south - western corner .
3.3 Real Estate’s property inspection reports
Inspection
Report
17/09/ 2015
There are some Issues that have been brou ght up. They are ongoing but not a
drama (as per previous report)
Rusty rear gutter
Drain pipe outlets not connected properly (images 1 and 2 of bathroom basin and
kitchen sink external det ached pipes provided)
Gap in corner back fence
Report and images fu rther show cracking to kitchen wall near the ex haust though
not mentioned in the report is clearly visible in Image 5
Inspection
Report
13/04/ 2016
Kitchen - Issues with stove and cracking to wall near the exhaust
Leaking in the pergola
Rusty rear gutter
Drain pipe outlets not connected properly (images of bathroom basin and kitchen
sink external det ached pipes provided)
Image 8 shows house is on a slant, but this has been mentioned for the first time
only in 27/07/2017 report
Inspection
Report
16/08/ 2 016
Kitchen - Issues with stove and cracking to wall near the exhaust
Determination | Case number: 698721 Page 10 of 11
Inspection
Report
17/09/ 2015
There are some Issues that have been brou ght up. They are ongoing but not a
drama (as per previous report)
Rusty rear gutter
Drain pipe outlets not connected properly (images 1 and 2 of bathroom basin and
kitchen sink external det ached pipes provided)
Gap in corner back fence
Report and images fu rther show cracking to kitchen wall near the ex haust though
not mentioned in the report is clearly visible in Image 5
Inspection
Report
6/12/2016
Kitchen - Issues with stove and cracking to wall near the exhaust
Crack in toilet S Bend
Inspection
Report
4/04/2017
Crack in toilet S Bend
Inspection
Report
27 /07/ 2017
Crack in toilet S Bend
Kitchen - Issues with stove and cracking to wall near the exhaust
Inspection
Report
23/11/ 2017
Flooring of house always feels like it's on the slant
Crack to toilet s bend
Still waiting on plumber to look at leaking tap
Property inspection report mentions cracks to:
Kitchen cornices, ceiling near the exhaust and adjacent to the lounge room
Lounge room wall
Entrance hall wall above the door frame
Inspection
Report
19/07/ 2018
Back fence has cracks and gaps
Tenant reports the bathroom basin hot tap leaking toilet cistern won't stop filling
Flooring of house always feels like it's on the slant
Property inspection report mentions cracks to:
Kitchen cornices, ceiling near the exhaust and adjacen t to the lounge room
Lounge room wall
Entrance hall wall above the door frame
Inspection
Report
13/11/ 2018
It feels like house is dropping
Kitchen tap is dripping
Back fence has cracks and gaps
Flooring of house always feels like it's on the slant
Property inspection report mentions cracks to:
Kitchen/ dining cornices, ceiling near the exhaust and adjacent to the lounge room
Lounge room wall
Determination | Case number: 698721 Page 11 of 11
Inspection
Report
17/09/ 2015
There are some Issues that have been brou ght up. They are ongoing but not a
drama (as per previous report)
Rusty rear gutter
Drain pipe outlets not connected properly (images 1 and 2 of bathroom basin and
kitchen sink external det ached pipes provided)
Gap in corner back fence
Report and images fu rther show cracking to kitchen wall near the ex haust though
not mentioned in the report is clearly visible in Image 5
Inspection
Report
12/03/ 2019
Tenant reports the bathroom basin hot tap leaking toilet cistern won't stop filling
Flooring of house always feels like it's on the slant
Property inspection report mentions cracks to:
Kitchen cornices, ceiling near the exhaust and adjacent to the lounge room
Lounge room wall
Entrance hall wall above the door frame
Lots of movemen t and cracking in the driveway
Rain water pipe in the air at the rear is broken and separated
Inspection
Report
9/07/2019
Flooring of house always feels like it's on the slant
Lots of cracks noted too:
Kitchen cornices, ceiling near the exhaust and adjacent to the lounge room
Lounge room wall
Entrance hall wall above the door frame
Fencing to No.14 is on a lean