Home / Allianz Australia / Determination 698721

Determination 698721

Declined cracking and sloping damage to tenanted home

FirmAllianz Australia
Decided2020-11-13
ProductGeneral Insurance · Landlord
OutcomeFor the complainant in part
Amount awarded$9,500
Non-financial loss—
Amount claimed—
SourceAFCA PDF

Summary

The landlord claimed for cracking and floor slope damage to a tenanted home and the insurer declined most of it. AFCA found most damage pre-dated the policy or resulted from excluded wear and tear, but ordered the insurer to pay the accepted kitchen/laundry repair amount of about $9,500.

Under the listed events policy, damage that began before inception or results from gradual deterioration and wear and tear is excluded.

Issues

Subjects and remedies

home or building damagepay claim

Related

All Allianz Australia determinations · Find similar determinations

Text of the determination

Determination Case number 698721 Financial firm Allianz Australia Insurance Limited Determination | Case number: 698721 Page 2 of 11 Case number: 698721 13 November 2020 1 Determination overview 1.1 Complaint The complainant holds a landlord insurance policy (policy) with the financial firm (insurer), covering a tenanted property. On 30 September 2019, the complainant lodged a claim for damage to the insured home in the form of cracking damage to walls and ceilings as well as a slope in flooring levels. The insurer, having completed its investigation into the damage claimed, has accepted to cover some of the damage whilst rejecting a majority of the damage on the basis it was not caused by an insured event within the period of insurance. The complainant remains dissatisfied with the insurer‟s assessment of its liability under the claim. 1.2 Issues and key findings Is the insurer entitled to limit its liability under the claim in line with the policy? The policy is a listed events policy subject to several specific exclusions. I am satisfied, other than the damage to the kitchen/laundry area which has been accepted under the claim, the insurer is entitled to decline cover for the remaining damage. I am satisfied the proximate cause of the remaining damage was due to circumstances clearly excluded from cover under the policy. 1.3 Determination This determination is in favour of the insurer. The insurer is entitled to decline cover for the damage to the insured building it has assessed to be excluded from cover in line with the policy provisions specified in the product disclosure statement (PDS). Determination | Case number: 698721 Page 3 of 11 2 Reasons for determination I have decided this case based on what is fair in all the circumstances, having regard to the relevant legal principles, good industry practice, industry codes of practice and previous relevant decisions of AFCA or predecessor schemes. I have considered all the material submitted by the parties both, before and after the recommendation. I am satisfied the documentation I have relied on has been provided to both parties for their consideration and comment. 2.1 Is the insurer entitled to limit its liability under the claim? The policy covers loss or damage caused by the listed insured events The policy covers direct or indirect loss or damage to the insured property caused by one or more of the listed insured events, within the period of insurance. Cover for such loss or damage is subject to the limitations and exclusions specified in the PDS. The PDS provides a clear list of events/circumstances, which if result in loss or damage to the insured property, triggers cover under the policy. This includes loss or damage which may occur due to an escape or leaking of water (liquid). The policy is subject to the limitations and exclusions specified in the PDS Cover for loss or damage to the insured property, even if shown to have been the result of circumstances covered under the policy, remains subject to the limitations and exclusions specified in the PDS. Relevant to this complaint, the policy excludes from cover loss or damage which:  occurs outside the period of insurance e.g. occurs or has been occurring since before inception of the policy  is not caused directly or indirectly by a listed insured e vent  occurs due to wear, tear, gradual deterioration or depreciation. 2.2 Is the insurer entitled to decline the complainant’s claim ? The insurer has accepted to cover part of the damage claimed There is no dispute, on the advice of the consultants appointed by the insurer to investigate the cause and extent of the damage claimed, that it has accepted to cover some of the damage noted in the kitchen/laundry area of the property. The insurer says, in good faith, it accepts that some of this damage is due to the leaking kitchen waste under the slab, which caused heave of the foundation soils in this area. I note the cost to repair this damage was quoted to be around $9,500. I also note, after receiving a supplementary report from appointed engineers „IM‟ dated 4 August Determination | Case number: 698721 Page 4 of 11 2020, the insurer commented that it may consider withdrawing the offer to accept to cover this portion of repairs to the kitchen/laundry area. However, I am not satisfied it was confirmed, to the complainant or AFCA, that the offer had been withdrawn. Without such confirmation from the insurer, I am satisfied the offer remains open and is fair in the circumstances. AFCA has not been provided with a detailed scope of works for these repairs, other than the quoted estimate of $9,500. The available information says it is possible the leak in the laundry waste caused a heave of the footings around the laundry/kitchen which contributed to some of the cracking in these rooms. Therefore, within 14 days of the complainant accepting the determination, the insurer is to arrange for the above noted payment to be made to the complainant or alternatively, arrange for the said repairs to be completed. The complainant says claimed damage occurred after he bought the property The complainant says the property sustained significant cracking damage including sloping of the floor because of an escape of water from damaged/leaking stormwater pipes. The complainant says none of the below issues were present at the time he purchased the insured property in April 2015:  cracking of the cornices  cracking of ceiling and walls  hallway door not closing  failure of the roof trusses by way of nailplate backout. The property was tenanted, and the sloping floor issue was not brought to his attention until July 2017. The damage has been present and/or increasing from before policy inception I am satisfied the insurer has established, on balance, the damage to the insured property (other than that accepted under the claim) is not directly or indirectly related to an insured event. The insurer appointed loss adjusters „C, plumber „PP‟ and engineers IM. The complainant has not provided any expert evidence. He advised that a plumber was initially appointed, however, that this plumber did not provide a report and given the extent of damage noted, he recommended the complainant to lodge a claim under the policy. The complainant, despite requests from the insurer and AFCA, has not made available a pre-purchase building inspection report for the insured property. Determination | Case number: 698721 Page 5 of 11 PP confirmed there were many issues relating to the home‟s stormwater and waste pipes. It noted all the waste pipes at the rear of the home had sheared off and were leaking into the soil between the rear pavement and wall each time they were used. IM acknowledged this, however, says that there is no evidence of localised footing heave that would be expected if the leaks had contributed to the damage to the insured building. Other than the damage in the kitchen/laundry area which has been accepted, IM considered the damage to the property was not caused by the leaks. IM says movement of the building has been an ongoing problem for the property with the home being in a distorted shape for an extended period of time due to seasonal and environmental influences. It says this is also reflected in the internal floor levels survey, which shows a planar type tilt down towards the southern (front) side of the house. IM says the shearing of the pipes at the rear of the insured building was the result of the long-term tilt of the home supported by the gap between the wall and rear pavement. The pipes shearing was the result of the movement as opposed to the leaking pipes being the cause of movement and associated damage to the pipes. IM reiterates that the brick course levels survey does not show a heave pattern of movement, which is what it would expect to observe if the leaks had caused the damage. In IM‟s opinion, the pattern is consistent with a drying sett lement towards the home‟s front The overall slant/sloping reported in the inspection reports has been dominantly caused by the same settlement mechanism described with regards to the superstructure. IM acknowledges this is the primary area of concern fo r the complainant, however, the slope is towards the south-western corner, which is also the area that IM believes has suffered from the most severe settlement. IM says, although the differential footing movement may only have recently been noted by the property manager/complainant, this is a process that does not occur suddenly. Rather, it occurs overs over an extended period of time, which IM says is consistent with the historical photographic data made available for review. These pictures show presence of movement damage at the insured property at the time it was advertised for sale in 2015.The images span from 2011 to 2015 and establish, on balance, the movement of the building had been ongoing for a long time including before the complainant purchased the property. I note this view is further supported by photographic evidence that forms part of the R‟s ( property manager) routine inspections. I accept refere nce to such damage may not have been made until 2017, however, the photos show existence of cracking damage from 2015. On balance, I accept this damage was present before the complainant purchased the property. Determination | Case number: 698721 Page 6 of 11 The complainant says no repairs to the insured building were authorised or undertaken by him relating to these issues discussed above. However, IM found evidence of, and for which photos have been supplied, showing such repairs had been previously completed, which therefore on balance occurred before the complainant purchased the property. Without evidence to the contrary, I am satisfied, on balance, that the damage has been gradually occurring over an extended period of time that dates to before the policy was incepted. Such damage is excluded from cover in line with the policy provisions. Damage noted to roof trusses is a separate event and excluded from cover I am satisfied the damage to the roof trusses did not arise from an insured event but was most likely due to gradual deterioration and wear and tear. IM noted that the dimpling and cracking damage to the ceilings was due to their longitudinal alignment which it says is evidence of poor performance of the roof framing. IM found there was evidence of nailplate backout, which is a progressive failure of the roof trusses due to the nailplates withdrawing from the timber. IM explains that this occurs when the teeth or nails of the plate are progressively worked out of the timber because of the expansion and contraction of the timber due to variations in moisture content. This has weakened the trusses over time which has resulted in the cracking and dimpling of the ceiling and cornices. In IM ‟s opinion, the damage to the ceiling and cornices is unrelated to building movement because of the reactive foundation soils. Rather, it relates to the failure of the roof framing. The complainant has not provided any evidence to dispute this opinion. Based on the available information, I am not satisfied the damage to the ceiling and cornices is the result of an insured event. In my view, the damage was caused by wear and tear or gradual deterioration which is excluded under the policy. Insurer is entitled to limit its liability Accordingly, for the reasons considered above, and without information to the contrary, I determine the insurer is entitled to limit its liability under the terms of the policy to the damage in the kitchen/laundry area. Determination | Case number: 698721 Page 7 of 11 3 Supporting information 3.1 AFCA approach to this complaint This complaint has been determined based on what is fair in all the circumstances, having regard to the relevant law, good industry practice, codes of practice and previous decisions of AFCA or its predecessor schemes (which are not binding). A full exchange of the relevant information has taken place between the respective parties. Each party has had the opportunity of addressing any issues raised. All the provided material has been reviewed and considered. The parties have raised numerous issues in their submissions to AFCA. However, commentary in this determination is restricted only to those issues considered relevant to the outcome. 3.2 Consultants’ evidence Record Key points C 1 st Asse ssment Report  site attendance for 1 October 2019  f urther investigation by a plumber and engineer is required. PP Leak Investigation Report 9 October 2019  visible cracking and movement throughout h ouse  a test of all internal and external mains water pip e work recorded a static result  n o leaks were detected in the water supply pipework (including both hot and cold).  n umerous issues were found with the stormwater drainage around the home (mostly associated with installation issue s that are readily observable)  a blockage and a separate break were found in the stormwat er pipe in front of the home‟s south - western corner  a break in the stormwater pipe was found adjacent to the north - western corner  t he sewer was found to be in poor c ondition, with several breaks / misalignments of joints in the earthenware pipework that extends adjacent to the rear elevation  a ll waste pipes were broken where they exited the rear elevation‟s footing and before they connected to the main sewer drain. PP expect these pipes are leaking with each use of the servic es they drain.  PP believe the laundry waste pipe is leaking beneath the floor slab. IM Engineers Report 10 December 2019  attended 5 November 2019  IM provide d the following opinions. - t he cracking and distortion to this home has been caused by differential footing movement because of moisture fluctuations i n the reactive clay foundation - s easonal and environmental influences are the dominant cause of Determination | Case number: 698721 Page 8 of 11 Record Key points the damage causing movement identified in Item 1 - m ovement has been an ongoing problem for this home, and the home has been in the noted distorted shape f or an extended period (including prior to the complainant purchasing the home) - it is possible the kitchen waste leak has contributed to some of the damage (particularly around the kitchen/laundry) - IM does n ot believe the other leaks identified have caused movement to the home (rat her, the lea ks have been caus ed by the movement) - t he damage to the ceiling has been caused by progressive failure of the roof trusses from nailplat e backout and needs urgent attention IM Supplementary Report 4 August 2020  JC attended the site on 22 June 2020  carried out a second perimeter brick cours e levels survey  also carried out an internal floor levels survey  o ur position on this matter remains as outlined in IM‟s previous report. That is : - the gross movement to the home has been caused by a long - term sett lement trend towards the home‟s front, and - it is possible the leak in the laundry waste has caused a heave of the footings around the laundry / kitchen area, which has contribut ed to some of the cracking in these rooms – although IM consider s this possibi lity is less likely after most recent inspect ion  i n fact, in IM‟s opinion, the front lawn being reported as “dry” and shown as dry in some of the summer / autumn inspection reports supports its position that the foundation beneath this home (particularly at its front) has been subject to considerable seasonal and environmental changes in soil moisture, which exacerbates long - term drying settlements.  IM also reiterate that the brick course levels survey does not show a heave pattern of movement, which is w hat we would expect to observe if the leaks had caused the damage. In IM‟s opinion, the pattern is consistent with a drying settlement towards the home‟s front  this is also believe reflected in the internal floor levels survey, which shows a planar type ti lt down towards the southern (front) side of the house.  e vidence obtained during the most recent inspection also indicates it is less likely that the leak from the laun dry waste has caused any damage  a review of photos of the crack in the kitchen wall adj acent to the rangehood (which was one of the cracks that IM considered could have been caused by the leak) has narrowed since IM‟s original inspection. In IM‟s opinion, this is evidence that this cracking has more likely been caused by seasonal and environ mental influences – not the leak  t he complainant al so advised IM that he had not carried out any repairs to cracking to the home during his ownership. During IM‟s Determination | Case number: 698721 Page 9 of 11 Record Key points most recent inspection, it observed evidence of repairs to cracking above the laundry door (photo 3 below). Other evidence of past differential movement to and around the home i s shown in the photos  d espite the complainant‟s view that the home had not suffered from at least some form of damage causing differential footing movement prior to his o wnership, in IM‟s opinion, there is evidenc e that it had  t herefore, IM maintain s the opinion th at the movement evidenced in its levels survey has occurred over an extended period of time, and that differential footing movement has been a long - term problem for this home  in IM‟s opinion, the overall “slant” reported in the insp ection reports, and to which it believes is the insured‟s primary concern with the floor, has been dominantly caused by the same settlement mechanism described with regards to the super structure  IM un derstand s the area of primary concern is towards the floor‟s south - western corner, which is also the area that IM believed has suffered from the most severe settlemen t A  a ny contribution from the laundry waste (if such a contribution exists) , would be limited to the area around the laundry and kitchen, and would not have a noticeable influence on the floor‟s south - western corner . 3.3 Real Estate’s property inspection reports Inspection Report 17/09/ 2015 There are some Issues that have been brou ght up. They are ongoing but not a drama (as per previous report) Rusty rear gutter Drain pipe outlets not connected properly (images 1 and 2 of bathroom basin and kitchen sink external det ached pipes provided) Gap in corner back fence Report and images fu rther show cracking to kitchen wall near the ex haust though not mentioned in the report is clearly visible in Image 5 Inspection Report 13/04/ 2016 Kitchen - Issues with stove and cracking to wall near the exhaust Leaking in the pergola Rusty rear gutter Drain pipe outlets not connected properly (images of bathroom basin and kitchen sink external det ached pipes provided) Image 8 shows house is on a slant, but this has been mentioned for the first time only in 27/07/2017 report Inspection Report 16/08/ 2 016 Kitchen - Issues with stove and cracking to wall near the exhaust Determination | Case number: 698721 Page 10 of 11 Inspection Report 17/09/ 2015 There are some Issues that have been brou ght up. They are ongoing but not a drama (as per previous report) Rusty rear gutter Drain pipe outlets not connected properly (images 1 and 2 of bathroom basin and kitchen sink external det ached pipes provided) Gap in corner back fence Report and images fu rther show cracking to kitchen wall near the ex haust though not mentioned in the report is clearly visible in Image 5 Inspection Report 6/12/2016 Kitchen - Issues with stove and cracking to wall near the exhaust Crack in toilet S Bend Inspection Report 4/04/2017 Crack in toilet S Bend Inspection Report 27 /07/ 2017 Crack in toilet S Bend Kitchen - Issues with stove and cracking to wall near the exhaust Inspection Report 23/11/ 2017 Flooring of house always feels like it's on the slant Crack to toilet s bend Still waiting on plumber to look at leaking tap Property inspection report mentions cracks to: Kitchen cornices, ceiling near the exhaust and adjacent to the lounge room Lounge room wall Entrance hall wall above the door frame Inspection Report 19/07/ 2018 Back fence has cracks and gaps Tenant reports the bathroom basin hot tap leaking toilet cistern won't stop filling Flooring of house always feels like it's on the slant Property inspection report mentions cracks to: Kitchen cornices, ceiling near the exhaust and adjacen t to the lounge room Lounge room wall Entrance hall wall above the door frame Inspection Report 13/11/ 2018 It feels like house is dropping Kitchen tap is dripping Back fence has cracks and gaps Flooring of house always feels like it's on the slant Property inspection report mentions cracks to: Kitchen/ dining cornices, ceiling near the exhaust and adjacent to the lounge room Lounge room wall Determination | Case number: 698721 Page 11 of 11 Inspection Report 17/09/ 2015 There are some Issues that have been brou ght up. They are ongoing but not a drama (as per previous report) Rusty rear gutter Drain pipe outlets not connected properly (images 1 and 2 of bathroom basin and kitchen sink external det ached pipes provided) Gap in corner back fence Report and images fu rther show cracking to kitchen wall near the ex haust though not mentioned in the report is clearly visible in Image 5 Inspection Report 12/03/ 2019 Tenant reports the bathroom basin hot tap leaking toilet cistern won't stop filling Flooring of house always feels like it's on the slant Property inspection report mentions cracks to: Kitchen cornices, ceiling near the exhaust and adjacent to the lounge room Lounge room wall Entrance hall wall above the door frame Lots of movemen t and cracking in the driveway Rain water pipe in the air at the rear is broken and separated Inspection Report 9/07/2019 Flooring of house always feels like it's on the slant Lots of cracks noted too: Kitchen cornices, ceiling near the exhaust and adjacent to the lounge room Lounge room wall Entrance hall wall above the door frame Fencing to No.14 is on a lean

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.