Text of the determination
Determination
Case number 695660
Financial firm Allianz Australia Insurance Limited
Determination | Case number: 695660 Page 1 of 7
Case number: 695660 2 September 2020
1 Determination overview
1.1 Complaint
The complainant is a lot owner and beneficiary under a strata insurance policy held
with the financial firm (insurer). The complainant lodged a claim for damage to the
floor tiles in her lot. The complainant says an earthquake caused the tiles to lift and
break.
The insurer assessed the damage and acknowledged the occurrence of the
earthquake, however, it says the proximate cause of the loss is poor workmanship. As
that is excluded from the policy, the insurer declined the claim.
The complainant believes her claim should be covered.
1.2 Issues and key findings
Is the insurer entitled to decline the claim?
The complainant established a valid claim for physical loss/damage to her floor tiles
following the earthquake. The insurer has not established, on balance, that exclusions
apply to entitle it to decline the claim. Even if the installation of the tile flooring was a
contributing factor in the damage, the proximate cause of the damage (that is, the
effective, dominant or operative cause) was, on balance, the earthquake; and the
policy is intended to cover a broad range of damage. The insurer is not entitled to
decline the claim.
Given the nature of the damage, that means it is also fair in the circumstances that
the insurer covers loss of rent while repairs were carried out, subject to the
complainant providing reasonable evidence of the weekly rental income received
before the tenant vacated.
1.3 Determination
This determination is in favour of the complainant.
The insurer is required to pay the complaina nt’s claim for replacement flooring
($20,267.50). It is also required to pay loss of rent from the date the tenant vacated
on 6 December 2019, to the date repairs were completed 17 January 2020,
calculated on the basis of a weekly rent of $620, subject to the complainant providing
evidence of that weekly rental income.
Interest is to be paid on the total settlement, less the policy excess, in accordance
with section 57 of the Insurance Contracts Act 1984 (Cth), calculated from 10
December 2019 until payment is made.
Determination | Case number: 695660 Page 2 of 7
2 Reasons for determination
I have decided this case on the basis of what I consider fair in all the circumstances,
having regard to the relevant law, good industry practice, codes of practice and
previous AFCA decisions.
I have taken into account all the material submitted by the parties, both before and
after the preliminary assessment. I am satisfied that the documentation I have relied
on has been provided to both parties. For the purposes of this determination, I will
deal with only those points considered relevant.
2.1 Is the insurer entitled to decline the claim?
Complainant has established a valid claim
The complainant’s policy provides broad cover for physical loss or damage to her lot.
When lodging a claim, the onus lies with the complainant to establish the claimed
damage arose from an event covered under the policy. This is known as a prima facie
or valid claim.
The complainant lodged a claim for lifting and cracking of floor tiles in the lot, which
she says was caused by an earthquake. It is not in dispute an earthquake occurred
on 24 June 2019. It is also not in dispute that the tiles have been damaged.
On this basis, I am satisfied the complainant has established a valid claim for cover
under her policy.
The onus then shifts to the insurer to show, on the balance of probabilities, it is
entitled to rely on a policy exclusion or is otherwise entitled to decline the claim.
The insurer says the damage was caused by faulty workmanship
The insurer does not accept the cause of the tiles lifting and breaking was the
earthquake. Instead it says the damage to the tiles was the result of faulty
workmanship, as well as gradual deterioration and developing flaws.
The policy excludes loss or damage caused by failure of design, faulty material or
faulty workmanship. It also excludes cover for gradual deterioration and developing
flaws.
The Body C orporate appointed engineer ‘AG’ to inspect the flooring. While AG’s
report of 11 July 2019 makes no explicit refere nce to the lot number inspected, I am
satisfied based on all supporting evidence that it does relate to Lot 5 (the
complainant’s). The photographs provided with AG’s report show very significant and
widespread lifting and cracking in Lot 5. AG concluded:
Determination | Case number: 695660 Page 3 of 7
It is likely that the tiles began to buckle and delaminate due to the lack of tile
expansion joints throughout the apartment. The earth tremor then further
exacerbated the problem which lead to widespread tile lifting/drumming. The
damaged floor coverings are not likely to have been caused by any major
structural problem.
I am not satisfied AG’s suggestion of the ‘likely’ influence of a lack of expansion joints,
is in itself sufficient to establish that was the proximate cause of the damage in this
case. The evidence also does not point to the tiles in the areas of significant damage
(the living room, kitchen, passageway, bedrooms 2 and 3) having begun to buckle or
delaminate prior to the earthquake.
The insurer appointed an assessor ‘CF’ and engineer ‘IC’ for an opinion on causation.
CF spoke with the tenant in the complainant’s unit , who confirmed that at the time of
the earthquake the tiles popped to the extent the tile pieces flew in the air hitting the
tenant.
IC, in their report of 31 July 2019, noted the extensive tenting failure in the damaged
areas of the lot noted above. IC found the floor tiles had been installed continuously
without any movement or expansion joints , and says the maximum run of continuous
400 x 400 floor tiles is 15 metres from the balcony to the back bedroom, and 9 metres
across the lounge/dining room.
IC explained that expansion forces from thermal and humidity changes over a long
period of time can cause dimensional growth. IC noted the tiles had lifted cleanly off
the concrete slab, and says this tends to support the long-term tile growth theory.
IC concludes by saying ‘ there may be some correlation with the earth tremor of 24
June 2019 and the explosive tenting which occurred after this event’; ‘the earth tremor
may have acted as a trigger to initiate the explosive debonding of already stressed
tiles ’ (my underlining). However, I consider the evidence is very clear that the
earthquake did at the very least ‘ trigger ’ the explosive tenting/debonding, and the
question then becomes (and is considered further below) whether that particular
damage would have occurred even without the earthquake.
The insurer subsequently obtained a further report dated 24 June 2020 from engineer
WS (formerly operating as IC), to comment on the tiled flooring and its compliance
with relevant building codes and practices. WS noted that the National Construction
Code (formerly BSA) does not prescribe the laying/installation of ceramic floor tiles;
although the Australian Standard AS3958.1 – 2007 (consistent with the 1991 version
in effect when the building was constructed ) provides a ‘guide to good tile laying’.
WS acknowledged that floor tenting failures following earth tremors (similar to the 24
June 2019 event) are not unknown in the area where the insured building is located;
and noted that an earth tremor can act as a trigger to initiate debonding of already
stressed tiles.
Determination | Case number: 695660 Page 4 of 7
WS summarised its view of the contributing factors to the tile debonding as:
failure to comply with AS3958.1 in that recommended movement and perimeter tile
joints were not installed
the adhesive being part cured when the tiles were laid (since the tiles lifted cleanly
off the adhesive which was still bonded to the concrete). WS said the tile failure
can be ‘partially attributed’ to that.
WS also noted the lounge room was subject to full sunlight on the floor for the early
part of the day, which can influence the flooring (although exposure to sunlight was
not mentioned as applying to the other affected areas).
I acknowledge the relevance of AS3958.1, but note it is a guide, not a prescribed
approach. So I am not persuaded a failure to strictly comply with that is, in itself,
sufficient to establish ‘faulty’ workmanship, nor to establish that was the reason for the
damage – particularly when the experts allow for at least partial contributions by both
the earthquake and the tile installation.
As well, I note there is no evidence to show that the presence of movement joints or
other adhesive would have prevented the damage. I consider a report from a qualified
and experienced tiler (in conjunction with the input of engineers) would have been
relevant in fully explaining the damage in the complainant’s lot.
Evidence shows some damage in other areas of the insured building
T he complainant’s lot was inspected by the property manager on 12 June 2019, just
11 days prior to the earthquake. The inspection report identifies no problems with the
flooring/tiles and the supporting photographs show the tiles to be in good condition. It
is also worth noting the tenancy in place at the time had commenced in April 2017,
and so it is reasonable to expect that if there had been any progressive issues with
the tiles becoming drummy or lifting over that time, that would have been noticed and
reported.
The only reference to flooring issues is an email from the tenant to the property
manager on 21 June 2019, to report some tiles in the master bedroom had lifted and
cracked. Relevantly, damage in the master bedroom is not recorded in the various
experts’ reports on the claim-related damage (and it is not included in the quote
obtained from HP by the Body Corporate for repairs); nor did the tenant report in that
email any damage in the areas subsequently affected when the earthquake occurred.
Flooring in other lots in the insured building had also been inspected by IC. In the
ground floor unit no drummy tiles were identified in the large living room area,
although a small crack was attributed to shrinkage in the concrete; in two larger top
floor units, one had isolated areas of drummy tiles (not attributed by IC to the
earthquake) but some movement in a ceiling sheet which was at least partly
attributable to the earthquake, and the other unit also had some areas of drummy
Determination | Case number: 695660 Page 5 of 7
tiles, with one area in a bedroom specifically identified by the lot owner as having
happened in the earthquake.
The building is on three levels. The complainant’s lot is on the middle level. It is worth
noting that the available information about the tiled flooring in the other units indicates
the damage there was considerably less severe than that in the complainant’s, even
though they too had large areas of tiled flooring, apparently also installed without
movement joints. (To be clear, I am not making any finding about the damage in
those other lots.)
None of the expert commentary considers how the acknowledged earthquake might
have impacted a unit in that middle level in that type of building differently from other
levels or areas of the building; nor does it otherwise attempt to explain why the
damage in the complainant’s unit was so much more severe.
Insurer has not established, on balance, exclusions apply
For the reasons above, I am not satisfied the insurer has shown, on balance, that
exclusions for faulty workmanship, gradual deterioration or developing flaws apply to
the circumstances of this claim.
Proximate cause of damage needs to be identified
While relying on the exclusions of faulty workmanship, gradual deterioration and
developing flaws to decline the claim, the insurer ’s experts do also acknowledge the
likely impact of the earthquake on the damage. That is despite the insurer saying that
the intensity rating of the earthquake in the relevant location was ‘light’ and not
expected to have caused damage.
For the insurer to be entitled to rely on a policy exclusion to decline the claim, it first
needs to establish the exclusion applies to the circumstances of the claim and it then
must show the excluded factor was the proximate cause of the damage.
For completeness, I will consider the issue of proximate cause, even though I am
already satisfied the insurer has not established exclusions apply in any case; and I
consider it clear the policy is intended to cover a broad range of loss and damage.
Determining the proximate cause of a loss is a question of fact, depending on the
circumstances in the particular case. It is well established law that a proximate cause
is not necessarily the first or the last or the sole cause of the loss. It is the effective or
dominant or operative cause of the loss.
If there are several causes of a loss operating contemporaneously, each must be
examined for the qualities of reality, predominance and efficiency as the active,
efficient cause that sets a relevant chain of events in action. If one cause would have
caused the harm in any case, and the other would not have done so in the absence of
the first, the first is the proximate cause.
Determination | Case number: 695660 Page 6 of 7
If it is not possible to identify which of two or more causes is the proximate cause then
they will be regarded as concurrent proximate causes. Concurrent causes can occur
where there are two or more events, each of which is independently capable of
causing the loss, or where there are two events each of which, without the other,
could not have caused the loss. In either case they are only concurrent if of equal
efficiency; and if they are equal, and one of those causes was an insured event, and
the other an excluded event, then the excluded event would prevail.
The insurer submits the Wayne Tank principle applies to the circumstances of this
claim. In the Wayne Tank case from which that principle derives, the causes of loss
were interdependent. In other words, one would not have caused the loss without the
other. In that situation, where one of the causes is a policy exclusion, then the
exclusion prevails to entitle the insurer to decline the claim.
However, as already noted, I am not persuaded the insurer has shown the exclusions
for faulty workmanship, gradual deterioration or developing flaws apply to the
significant damage in the complainant’s lounge room, passage and bedrooms one
and two. I am also not satisfied that the installation/condition of the flooring was a
factor equal to the impact of the earthquake.
I am satisfied, on the available evidence, it is more likely than not that the damage in
this claim would have arisen from the earthquake irrespective of any issues with the
tiling installation; and so the earthquake is, on balance, the proximate cause.
Insurer required to pay complainant’s costs of flooring repairs
The complainant has provided an invoice/receipt dated 5 December 2019 for
$20,267.50 for the cost of tiled flooring repairs. (That is not inconsistent with the HP
quote for $22,572 for the flooring, which did not include the master bedroom.)
I am satisfied it is fair and appropriate in the circumstances that the insurer pay the
complainant $20,267.50, together with statutory interest on that amount, calculated
from 10 December 2019 when it declined the claim, to the date of settlement.
Loss of rent applies
The policy also covers loss of rent where an insured loss or damage renders a unit
unfit to be occupied for their intended purpose.
The complainant has said her tenants vacated on 6 December 2019 and the property
could not be re-let because of the damage, which the complainant said was then
completed on 17 January 2020. However, the damage occurred in June 2019 and the
tenants appear to have remained in the property for a further 6 months , so it is not
immediately clear that the property was unfit to be occupied in the intervening period,
despite the obvious significant floor damage.
Determination | Case number: 695660 Page 7 of 7
At the same time, I do consider the property should be regarded as being unfit to be
occupied for its intended purpose, and could not reasonably be re-let , after the
tenants vacated and until the damage was repaired.
I am satisfied it is fa ir in the circumstances that the insurer pay the complainant’s loss
of rent for the period from 6 December 2019 to 17 January 2020, based on a rental of
$620 per week (together with statutory interest on that amount). That is subject to the
complainant providing any reasonably requested evidence of that having been their
rental income up to the point of the tenant vacating.
Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.