Home / QBE / Determination 681794
Determination 681794
Denial of building damage claim for foundation cracking and movement after stormwater leak
Summary
The unit owner claimed for foundation cracking after stormwater leaks, and the insurer denied the claim as long-term footing movement caused by tree roots and reactive soil. AFCA agreed the claim was not established and made no order.
The policy covers only sudden and accidental damage, and the evidence showed long-term settlement from tree drying, which is excluded as normal settling.
Issues
- Claim denial primary · not upheld“Damage was from long-term footing movement, not a sudden and accidental cause; the normal settling exclusion applied.”
- Inadequate claim investigation secondary · not upheld“The insurer's engineer's investigation was persuasive despite criticisms that it did not consider the plumbing reports.”
Subjects and remedies
home or building damageno remedy
Related
Text of the determination
Determination
Case number 681794
Financial firm QBE Insurance (Australia) Limited
Determination | Case number: 681794 Page 1 of 12
Case number: 681794 10 July 2020
1 Determination overview
1.1 Complaint
The complainant is a beneficiary under a residential strata insurance policy issued by
the financial firm (insurer).
The complainant lodged a claim with the insurer for water damage to the foundations
after multiple cracks appeared around the insured property. The first being noticed in
the kitchen following a loud bang heard at the property in January 2019. Since this
event, the cracking has worsened.
The complainant appointed an engineer (MM) to inspect the property. MM advised the
complainant to engage a plumber (TM) to inspect the stormwater drains that run
under the garage slab. TM took CCTV footage of the stormwater pipes and identified
several issues that may be causing the movement.
The insurer appointed an engineer (LO) to report on the damage and provide a
causation report. LO says the proximate cause is due to long-term settlement of
reactive soils and an inadequate footing system. This is not covered by the policy.
The complainant disputes the insurer’s decision and see ks for the claim to be paid.
1.2 Issues and key findings
Can the insurer deny the claim?
Yes. The policy responds to damage from any sudden or accidental cause. The
available information shows the damage was due to long term footing movement. As
this is not a sudden cause, the insurer can deny the claim.
1.3 Determination
This determination is in favour of the insurer.
The insurer is entitled to deny the claim and is not required to take any further action.
Determination | Case number: 681794 Page 2 of 12
2 Reasons for determination
2.1 Can the insurer deny the claim?
Complainant must establish a valid claim within the terms of the policy
The onus is on the complainant to establish, on the balance of probabilities, a claim
within the terms of the policy. This is known as a valid ( prima facie ) claim. Once
established the onus shifts to the insurer to establish, on balance, it is entitled to:
rely upon a condition or an exclusion contained within the policy, or
otherwise entitled to deny the claim.
The complainant’s policy provides cover for ‘D amage ’ to the insured property that
occurs during the period of insurance and is not otherwise excluded under the policy.
The policy defines ‘D amage ’ to be any partial or total accidental physical loss of, or
destruction of, property from any sudden and accidental cause not otherwise
excluded by the policy.
The insurer denies the damage was caused by a sudden and accidental event. The
insurer also says the cause of damage is excluded under the policy.
Both parties engaged engineers to review the damage
In January 2019, the complainant heard a large bang and noticed cracks appearing
within the property, specifically on top of the kitchen window. The cracks worsened in
the following days internally and externally.
Both parties engaged engineers to review the damage.
The complainant engaged MM. MM inspected the property and noted there was an
established gum tree in the neighbouring property that could be influencing ground
moisture conditions. However, MM also noted that plumbing investigations revealed
problems with the drains near the affected area of the building. MM said excessive
ground water will reduce the clay bearing capacity.
The insurer engaged engineer LO. LO did not accept the leaks were the cause of
damage. LO concluded the cause was long term footing movement due to differential
moisture content variation as a result of one or more factors. These factors included
tree root drying effects and inadequately designed footings.
LO’s evidence is persuasive
Having carefully considered the available information, I am persuaded by LO’s report
that the damage is not consistent with the leaks. This is due to the following.
Floor measurements were taken by both engineers. These show a pattern of fall
towards the southeast corner. This is towards the stormwater leak and the direction of
Determination | Case number: 681794 Page 3 of 12
trees. As LO noted, if the leak was the cause of the floor movements, there would be
expected heave in the area given the reactive clay, not settlement. Instead, the fact
there is settlement is consistent with the drying effects of the trees being the cause.
LO also conducted preliminary soil investigations near the leak. They indicate fill
material overlaying what appeared to be very stiff, dry clay/siltstone/sandstone to a
depth of 200mm and continuing to 700mm. There was no abnormal soil moisture or
saturation detected. This refutes the possibility that the cause of settlement was due
to the leak reducing the clay bearing capacity.
These points are significant and are not refuted by any other expert.
Complainant’s arguments do not assist her
The complainant has raised several arguments disputing LO’s report. This includ es
the following:
LO made no reference to MM ’s report
the trees are medium sized at most, with one large gum tree on the far side of the
neighbouring property
LO did not review the CCTV footage and only did one borehole
LO did not complete tests on the sewerage pipes or pressure test the plumbing
system
These arguments do not assist her. I do not accept LO ’s failure to consider the
plumbing investigations undermined his report. This is because he investigated the
foundation soil near the leak and did not find any abnormal moisture conditions. As
LO explained, if the leak caused the soil to reduce its bearing capacity, then it is
expected that the soil would be moist. The fact it was stiff and dry refutes this.
Regarding the trees, the floor survey shows a pattern of settlement towards them.
This shows they are a likely factor to the property’s settlement as tree roots will
reduce the moisture and cause the soils to shrink. This was also considered a
possibility by MM.
MM did not investigate the soil near t he leak. Given this, MM’s opinion that the soil
may have lost its bearing capacity has been refuted by LO’s investigation. Further,
MM’s floor survey measurements , and the possible influence of trees, was consistent
with LO ’s reasons .
The insurer can deny the claim
After carefully considering all the available information, I am not persuaded the
complainant has established a valid claim.
This is because I am not satisfied the cause of the damage was due to a sudden
event. Instead, the available information indicates the cause was long term foundation
movement, most likely caused by trees.
Determination | Case number: 681794 Page 4 of 12
Therefore, the insurer is entitled to deny the complainant’s claim.
Determination | Case number: 681794 Page 5 of 12
3 Supporting information
3.1 Relevant policy wording
Subject Terms
Policy 1 – Insured Property What We insure
If selected and shown in the Schedule, we will insure You up to the
Sum Insured shown for Policy 1 – Insured Property in the Schedule
against Damage to Your Insured Property which occurs during the
Period of Insurance.
Definitions
Page 8
Damage, Damaged
means any partial or total accident al physical loss of, or destruction
of property from any sudden and accident al cause not otherwise
excluded by this Policy .
Exclusions
Page 19
1. We will not pay for Damage caused by or arising directly or
indirect ly from:
…
l. normal settling, creeping, heaving, seepage, shrinkage, or
expansion in buildings, foundations/footings, walls, bridges,
roadways, kerbing, driveways, paths, garden borders and other
structural improvements;
…
2. We Will not pay for :
…
c . the cost of rectifying faulty or defective materials or faulty or
defective workmanship, design or specification;
3.2 Expert reports
Expert reports Key points
Complainant ’ s Plumbers
(TM) report
7 April 2020
Report on condition of stormwater drains
90mm stormwater drain camera inspected from the 300x300
stormwat er pit located at the rear of the driveway slab beside the
garden shed. Pipe heading to the rear right - hand side of the
property has a major break and dislodgment as seen in the start of
video 0 just beyond where the water is holding. This water will be
exiting the pipe out of the break and seeping in and around the
footings of the building.
Camera inspection of the line exiting the 300x300mm stormwater
Determination | Case number: 681794 Page 6 of 12
Expert reports Key points
pit to the right towards the garden shed has a dislodgment
immediat ely after the pit and water is not making it to the pit but
exiting out of the break. The line also has a major break and
dislodgment upstream to the down pipe on the side of the car port.
This drain is also holding water and doe s not have any fall what so
ever.
Camera inspection of the 150mm main shows there in insufficient
fall to the first pit in the drive way and the line is also holding water.
Approximately 1.5m from the 300x 300 pit at the rear of the car port,
there is a jo in with no cleaners and no glue and seems to be just
touching the bell end of the pipe. This is a very suspicious join and
I would highly recommend it would be a cause of the damage to
the property.
The stormwater pit at the rear of the car port also has no sealant
between the walls of the pit and the pipe work ent ering the pit
therefore any water ent ering the pit very easily seeps straight out
into the ground surrounding the building.
These multiple issue cause for major conc ern surrounding the
water dam age to the property.
Highly recommend relining of 150mm main under concrete
driveway and the replacement of other outlined issues.
Insurer’s a sse ssor report
- DL
21 May 2019
We advise that movement is occurring to unit 3 at the situation of
risk and the investigations undertak en by the unit owner have
revealed that there may be issues with the storm water drainage
causing foundation movement.
We now recommend that an engineer be provided with the
information supplied by the unit owner and if required a further
inspection completed to confirm the cause of the damage to the
unit.
Insurer’s engineer report -
LO
22 June 2019
Floor level Survey summary
An arbitrary dat um point w as selected at the front entry to the
west side of unit 3.
A maximum floor level differential of 44 mm was recorded
across the ground floor of unit 3.
Differential movement of the footing system is discernible.
Floor surface level exhibit a pattern of fall toward the sout h side
and predominantly southeast corner of unit 3 in the direction of
the group of large and medium sized trees and det ected
stormwat er defect to the south side of unit
Soil profile and site reactivity
Determination | Case number: 681794 Page 7 of 12
Expert reports Key points
Site borehole testing indicates fill material overlaying
clay/siltstone/sandstone soils. It is therefore ex pected that the
foundation soils will consist of reactive clays.
Class M site classification is expected in the absence of
abnormal site moisture conditions, indicating moderat ely
reactive soils, with an associated characteristic surface
movement (ys) value of bet ween 20 mm – 40 mm.
The existing groups of large and medium sized trees is
expected to result in a site classification of class P (problem
site) due to expected abnormal site moisture conditions.
Reactive clay soils experience volumet ric changes with relative
changes in moisture content. An increase in moisture content
causes the soil to swell (res ulting in heave of the footings) and a
decrease in moisture content causes the soil to shrink (resulting
in settlement of footings).
Existing footings and borehole results
the vicinity of the greatest detected footing settlement and
detected stormwater leak, to a depth of 700 mm below ground
surface level. Preliminary soil analysis indicates fill material
overlaying what appears to be very stiff, dry
clay/siltstone/sandstone at a depth of 200 mm and continuing
borehole termination at 700 mm.
A footing probe confirms a concret e edge beam approximately
500 mm deep and founded approximat ely 200 mm below
ground surface level onto the very stiff, dry
clay/siltstone/sandstone.
Pr eliminary footing investigations indicate the footings have not
been suspended on piers.
No abnormal soil moisture or saturation was detected at BH1.
Leak detection
A plumbing investigation of the sewer and mains water line was
not undertak en during th e owner’s commissioned investigation.
However, based on the results of the building survey and
preliminary soil testing, it is advised further plumbing
investigations are not required.
Has an escape of liquid caused the observed building
damage?
Cause of building damage
5.7 Based on the geological composition of the footings foundation,
an increase in foundation moisture content of the clay material is
expected to result in a volumetric increase of the foundation. Given
the estimated soil pressur e due to building loads, swell pressure
from the expanding clay is expected to cause heaving of the footing
Determination | Case number: 681794 Page 8 of 12
Expert reports Key points
system.
5.8 An escape of water is expected to cause localised variations in
the foundation moisture content res ulting in localised building
movemen ts. Building survey results confirm no pattern of expected
footing heave localised and isolated to the south side of unit 3 in
the vicinity of the reported stormwater leak, consistent with a
localised increase in the moisture cont ent of the reactive clay
f oundation due to an escape of water.
5.9 Building survey results confirm a pattern of fall toward the south
side and predominantly southeast corner of unit 3 consistent with
footing settlement toward this area. It is noted the pattern of
predominant fall toward the southeast corner of unit 3 is in the
direction of the reported stormwater leak and group of large trees.
5.10 Given the geological composition of the foundations, the
detected pattern of footing settlement is not consistent with an
increase in foundation moisture content. Preliminary soil
investigations to the southeast corner of unit 3 in the vicinity of the
detected footing settlement and reported stormwater leak, confirms
the foundation soils into which the footings have been founded are
very stiff and dry with no signs of abnormal soil moisture or
saturation. Furthermore, preliminary soil testing indicates that the
foundation bearing pressure is adequate for the estimated building
loads, which indicates the detected footing settlement has not been
caused by soil bearing failure due to saturation of the foundation. It
is the opinion of LO that an escape of water from the reported
stormwat er leak has not caused a reduction in the foundation
bearing pressure to cause the detected footing settleme nt of the
building.
5.11 It is the opinion of LO that the det ected pattern of building
movement is not consistent with a localised increase in moisture
content of the reactive clay foundation caused by an escape of
water from a stormwater leak to the sou th side of unit
5.12 It is further noted that the natural site topography exhibits a
minor to moderate fall toward the south. The leak is located to the
south side of the building, and therefore any escape of water will be
redirected away from the struct ural footing system with the natural
site topography
5.13 It is, therefore, the opinion of LO that the duration and volume
of water discharged from the reported stormwater leak to the south
side of unit 3, has been insufficient to adversely affect the vi rtually
impermeable foundation soils into whic h the structural footings
have been founded. The subject site exhibits good drainage. It is
the opinion of LO that any escaped water has runoff through the
graded stormwater trench or through the upper fill lay ers with the
natural site topography and has not adversely affected the moisture
content of the virtually impermeable foundation soils into which the
structural footings have been founded.
5.14 It is the opinion of LO that an escape of water from the
repo rted stormwater leak is not the cause of building movement or
damages.
Determination | Case number: 681794 Page 9 of 12
Expert reports Key points
Cause of damage to building
5.15 Stresses in a structure that cause cracking of building
materials can be induced by one or more of the following
contributing factors:
5.16 Given the soil geology and expected moderate reactivity,
footing movements due to moisture content variations in the
reactive clay foundations are expected. The reactive clays have an
expected moderate shrink/swell pot ential and are expected to
experience volumetric changes due to normal seasonal variations
in the moisture content of the clay foundation in addition to other
contributing factors such as site and urban development and long -
term environmental influences. The foundation soils are not
homogenous and will ex perience differential rates of settlement
and moisture content variation causing differential movement of the
footing system.
5.17 Groups of large and medium sized trees exist on and adjacent
the subject site, within close proximity to the str ucture and within
the ‘influence zone’ defined in AS 2870 within which tree roots can
affect the moisture content of foundation soils causing associated
footing movements. The presence of tree roots can reduce the
moisture content of the reactive clay
i . Footing movements.
ii. Thermal movements.
iii. Deflections, shortening, shrinkage, creep and similar
deformations in adjacent or associated materials.
iv. Deformations due to construction loads or construction
sequence.
5.16 Given the soil geology a nd expected moderate reactivity,
footing movements due to moisture content variations in the
reactive clay foundations are expected. The reactive clays have an
expected moderate shrink/swell pot ential and are expected to
experience volumetric changes due t o normal seasonal variations
in the moisture content of the clay foundation in addition to other
contributing factors such as site and urban development and long -
term environmental influences. The foundation soils are not
homogenous and will ex perience dif ferential rates of settlement
and moisture content variation causing differential movement of the
footing system.
5.17 Groups of large and medium sized trees exist on and adjacent
the subject site, within close proximity to the structure and within
the ‘i nfluence zone’ defined in AS 2870 within which tree roots can
affect the moisture content of foundation soils causing associated
footing movements. The presence of tree roots can reduce the
moisture content of the reactive clay
foundations causing shrinkag e of the clays and associated footing
settlement. Removal of trees can result in an increase in the
Determination | Case number: 681794 Page 10 of 12
Expert reports Key points
moisture content of the reactive clay foundation causing swelling
and associated footing heave.
5.18 Expected abnormal site moisture conditions due to the
presence of groups of large and medium sized trees within close
proximity to the building can ex acerbate volumetric changes in the
reactive clay foundations and subsequent footing movements
beyond what is normally expected.
5.19 Building survey results indicate a general pattern of fall toward
the south side and predominantly southeast corner of unit 3 in the
direction of the group of large and medium sized trees. The
detected pattern of fall is consist ent with settlement of the footing
system due to a reduction in the moisture content of the reactive
clay foundation, contributed to by tree root drying effects, resulting
in clay shrinkage. Preliminary soil testing indicates the foundation
bearing pressur e and foundation material is adequate for the
imposed building loads. Settlement due to bearing failure or
inadequate founding material is not expected indicating settlement
has been caused by a reduction in the moisture content of the
reactive clay founda tion.
5.20 Site observations and crack pattern analysis also confirm a
pattern of settlement of the unit 2 garage toward the group of trees
to the north side of the garage structure, consistent with footing
settlement. This furt her confirms footing moveme nt due to site
reactivity and abnormal soil moisture caused by trees is a
wides pread issue at the site, and not a localised issue due to an
escape of water.
5.21 It is the opinion of LO that the det ected pattern of footing
settlement toward the south side of the building has been caused
by groups of trees to the south side of the building causing a
reduction in the moisture content of the reactive clay foundation.
5.22 Differential footing movement will induce stress in the
structure res ulting in cracking and structural movement. The
observed building cracking and movement is consistent with the
detected differential footing movement to the building. The detected
settlement to the south side of the building has caused movement
of the south wall resulting i n widening of the articulation joints and
gaps bet ween the window frames and brick veneer wall. The
pattern of cracking to the plaster and brick walls is consistent with
the detected settlement toward the south side.
5.23 Footing investigations indicate that the design and
construction of the footing system of the building has adequate
stiffness to alleviate the effects of expected foundation reactivity
due to normal moisture conditions but is of inadequate depth to
alleviate the effects of abnormal site moisture conditions caused by
the groups of trees. Footing probes confirm the footings have not
been deepened or suspended to alleviate the effects of the trees.
Given the inadequate depth of the structural footing system,
susceptibility to movement due to foundation reactivity and
abnormal site moisture conditions caused by the groups of trees is
increased and long - term footing movements are expected. The
detected pattern of differential footing movement and performance
Determination | Case number: 681794 Page 11 of 12
Expert reports Key points
of the building is consistent with t hat expected given the
inadequate design of the footing system, foundation reactivity and
abnormal site moisture conditions.
5.24 Review of the engineering drawings confirms the slab edge
beam was document ed as suspended to the southeast corner of
the bu ilding on 450 mm diameter bored piers to a depth of 2000
mm. The installation of thes e piers is to alleviate the effects of
abnormal soil moisture conditions due to the trees within close
proximity. However, footing probes to the southeast corner did not
d etect a pier, and it is therefore advised that the documented piers
may not have been installed or have been installed in the wrong
position. Not withstanding, after review of the footing design, it is the
opinion of LO that the depth and number of bored pi ers is
insufficient to alleviat e the effects of abnormal soil moisture
conditions caused by the trees.
5.25 It is the opinion of LO that the obs erved damages to the
building has been caused by stresses induced from building
movements due to one or more of the following contributing factors:
Tree root drying effects due to the group of large and medium
sized trees within close proximi ty to the structure. This is
considered the primary cause of footing settlement toward the
south side of the building and subsequent building damage.
Changes in soil moisture content due to seasonal and climatic
effects.
The ‘drought’ conditions in Victo ria bet ween 1997 and 2010,
followed by the return of ‘normal’ rainfall patterns.
Long term consolidation of the clay foundations.
Inadequate founding depth of the existing footing system to
alleviate the effects of abnormal site moisture conditions cause d
by the trees within close proximity to the building.
5.26 It is the opinion of LO that the obs erved building damage is
classified as ‘slight’ to ‘moderate’ in accordance with AS 2870 –
2011. It is the opinion of LO that these observed damages do not
compromise the structural integrity or stability of the building.
Determination | Case number: 681794 Page 12 of 12
3.3 Footing plan prepared by geotechnical engineers