Home / Allianz Australia / Determination 677782

Determination 677782

Foundation heave damage to home claim declined as not an insured event

FirmAllianz Australia
Decided2020-09-03
ProductGeneral Insurance · Home building and contents
OutcomeFor the complainant
Amount awarded—
Non-financial loss$1,500
Amount claimed—
SourceAFCA PDF

Summary

The complainants claimed for heave damage to their home caused by a leaking sewer pipe, and the insurer declined the whole claim. AFCA found the rear eastern half damage was an insured event and must be covered, excluded the front western damage both parties agreed was not covered, and ordered professional costs reimbursed plus $1,500 for non-financial loss.

The complainants established a prima facie insured event through the expert evidence, so the onus shifted to the insurer, which did not prove an exclusion applied to the rear eastern section.

Issues

Subjects and remedies

home or building damagepay claimpay non financial loss

Related

All Allianz Australia determinations · Find similar determinations

Text of the determination

Determination Case number 677782 Financial firm Allianz Australia Insurance Limited Determination | Case number: 677782 Page 2 of 16 Case number: 677782 31 August 2020 1 Determination overview 1.1 Complaint The complainants hold a policy with the financial firm (insurer) to insure their home and contents. The policy provides cover for loss or damage to the insured property from listed insured events specified in the product disclosure statement (PDS), subject to the limitations and exclusions also provided in the PDS. On 31 May 2019, the complainants lodged a claim for extensive damage to the insured building said to be caused by liquid leaking from a broken sewer pipe. The insurer declined the claim, saying the complaints had not shown the damage claimed was due to an insured event. 1.2 Issues and key findings Is the insurer liable for the claim? The complainants have established, on balance, the escape of liquid from the leaking sewer pipe has caused some of the damaged claimed. This constitutes an insured event under the policy. The insurer has not shown that exclusions apply to allow it to decline liability for the full extent of the claim. Is the insurer liable for the complainants’ professional costs? The insurer is to cover the complainants for professional expenses incurred in investigating and quantifying the cause of damage. However, this does not include costs incurred in repairing the damaged sewer pipe. Are the complainants entitled to compensation for non-financial loss? The insurer’s overall management of this claim has resulted in an unusual and unreasonable delay causing the complainants stress and inconvenience, and so it is to pay the complainants $1,500 in non-financial loss compensation in line with the AFCA Rules. 1.3 Determination This determination is substantially in favour of the complainants. The insurer is to cover the complainant for the cost of repairs associated with the rear eastern section of the insured building. The insurer is to reimburse the professional costs incurred by the complainants in line with this determination. Further, the insurer is to pay the complainants $1,500 in compensation for non-financial loss. Determination | Case number: 677782 Page 3 of 16 2 Reasons for determination 2.1 Is the insurer liable for the claim? The complainants bear the onus to show the damage claimed is covered It is established law, to seek cover under the policy the onus first rests on the claimant to establish, on the balance of probabilities, the loss claimed is covered by the terms of the policy. Only once this has been established, will the onus shift to the insurer to establish, on balance, that it is not responsible to cover the claimant for the loss in line with a policy provision or exclusion. The complainants have sought the assi stance of ‘DC’ in bringing this complainant before AFCA. For this determination, reference to the complainant includes both the complainants and DC. The policy is an insured events contract of insurance The policy covers the insured building and contents against loss or damage caused by one or more of the listed insured events specified in the PDS. Cover under the policy benefits are subject to the limitation and exclusion provisions also provided in the PDS. Relevant to the consideration of this complaint, the policy includes the insured event Water or other liquid damage. Under this policy benefit the complainant is covered for loss or damage which results directly from the bursting, leaking, discharging or overflowing of various listed sources including fixed pipes. The policy also extends to cover the reasonable costs incurred in locating the source of damage to the insured property. The complainant in around April 2019 noted internal and external cracking to the bri ck walls and plaster at the insured property. In May 2019, the complainant noted the cracking was getting increasingly worse and for which a claim was lodged under the policy on or about 31 May 2019. The complainant is of the view the damage is the result of a leaking sewer pipe located by plumbing consultants ‘SS’ and supported by engineering consultants ‘ST’ appointed by the complainant. The insurer, however, says it is entitled to decline the claim as it says the damage to the insured building is not the result of an insured event. Therefore, in line with the policy, the complainant has not established a prima facie claim. The insurer relies on the evidence provide by engineering consultants ‘SG’, it appointed to the claim. Determination | Case number: 677782 Page 4 of 16 Damage to the front western section of the building is excluded The parties to this complaint do not dispute there exists extensive internal and external cracking damage, which varies in severity, in most areas of the insured building. There is no dispute that there exists a clear distinction in the proximate cause for the damage to the front western half of the home compared to the rear eastern half of the home. Both parties to the complaint agreed the damage to the front western half of the building is not covered as this is not the result of an insured event to which the policy responds. Rather, this damage is the result of ongoing gradual subsidence and resultant fall in the floor levels. This is, on balance, related to vegetation located in close proximity to the front of the insured building. These are not circumstances which trigger cover under the policy. This complaint relates to the damage noted to the rear eastern half of the insured building. The parties differ in their opinion as to the proximate cause for this damage. In saying that, both parties agree, the damage is the result of volumetric variation of the underlying clay foundation soils (clay). This occurs with changes in the moisture content of the clay, in this case introduction of moisture and resultant swelling of the clay (heave). Evidence shows, on balance, escape of liquid is the cause for the damage The parties both heavily rely on the opinions put forward by their appointed consultants, who have each provided multiple reports/communications in support of their positions. The relevant information from these reports and communications has been provided in section 3 of this determination. As noted above, both parties accept the damage is the result of heave and this is due to an introduction of moisture into the foundation clay located in the subfloor area of the home. The complainant says this introduction of moisture is the result of a leaking subsurface sewer pipe found to the southern side of the building next to the hot water system. The insurer, however, says the damage could not be the result of the leaking sewer pipe and it may possibly be the result of overland stormwater run-off. It says the complainant has not been successful in establishing the damage is the result of an insured event and as such it is has declined the claim in its entirety. Evidence relied on by the insurer The insurer in seeking to decline the claim for the most part relies on information provided by its appointed engineering consultants SG. I have considered the reports Determination | Case number: 677782 Page 5 of 16 from SG and am satisfied, on balance, SG relies on the following findings and opinions:  the ground at the insured property naturally slopes from south to north  it found a noticeable upward bulge to window sills and eave linings above bedroom windows on the northern side of the building  there was a gap of around 30mm between the driveway concrete slab and the northern external brick wall of the building  the subfloor clay presented with shrinkage cracks and was found to be dry at surface level. The lowest point of the subfloor area is in the northern eastern corner under bedroom 2  there were two damaged concrete stumps under bedroom 2 which appeared to have been pushed out of the ground, consistent with clay heave  the clay heave has not been caused by any issues with the leaking sewer pipe located on the southern side of the building. If it had been, SG would have expected to notice moisture in the subfloor area at the time of its inspection  clay is relatively impermeable material and any instance of subsurface waterflow through clay would be very slow. Gi ven this, any effects of heave would be greatest near the leaking pipe itself, which was not the case in this instance  the variation in floor levels noted at the southern side of the building were normal for a building constructed in the 1980’s and built on shallow footings  water leaking form the sewer pipe would have followed the path of least resistance, which in this instance, would have been to follow the path of the pipe down the southern side of the building towards the eastern boundary, not northwards  it would be impossible for vegetation located near to the southside external wall to have absorbed excess moisture and prevent excessive heave, yet at the same time allow moisture to travel towards the northern wall  it is possible, the moisture resulting in the heave is the result of stormwater run-off entering the subfloor area through the southern brick wall due to the natural slope of the property. On this basis, the insurer says the complainant has not established the leaking sewer pipe is the cause for the damage claimed. Further, that the complainant has not shown the damage is the direct result of any of the listed insured everts. So, the insurer maintains it is entitled to decline the claim. Evidence relied on by the complainant The complainant relies on information provided by his appointed plumbing and engineering consultants. I note SS (plumbers), were appointed midway through the claim and after SG and ST had attended to complete their investigations into the cause and extent of the damage claimed. Determination | Case number: 677782 Page 6 of 16 SS attended the insured property on 5 March 2020 to excavate and repair an existing damaged sewer pipe, located on the south side of the building. While excavating the location it found the soil surrounding the broken pipe to be considerably wetter than the soil closer to the surface. It found the sewer PVC pipe had sheared all the way around and had opened up approximately 1.5cm. There was some tree root intrusion, which by the amount, SS formed the view the pipe may have broken within the last two years. If it had been earlier than this, SS would have expected the pipe to have been overrun with tree roots and be blocked. I have reviewed the report and communications from engineering consultants ST and am satisfied, on balance, they came to the following opinions and conclusions:  ST attended on 2 October 2019, to complete its investigations at the insured property  the soil conditions consisted of clay and were typically assessed as Class H2 to E. The site sloped from south to north and then again from west to east  inspected the subfloor beneath the rear half of the building and noted the northeast corner as being the lowest ground level  the area seemed dry and at the surface and had shrinkage cracks. ST noted presence of efflorescence over most of the subfloor area and bottom one to three courses of bricks of the external walls. This is indicative of water having been in the area  ST excavated adjacent to bedroom 2 and 3 external wall, where most significant heave was evident, and at a depth of 150-200mm found the clay to be wetter  it is possible water leaking from the sewer pipe has seeped through the subfloor clays flowing with gravity to the northern external wall and strip footing. This will have resulted in an abnormal moisture condition increasing the volumetric variations  ST strongly holds the view that it is subsurface water that has caused the abnormal moisture conditions. Further, that it is unlikely to be overland stormwater flo w as suggested  the floor level survey completed shows the entire eastern half of the building has higher floor levels including the southern side, with the highest levels noted under bedroom 2 and 3. This shows a migration of water through the clay soils from the southern side to northern side  if the site was flat, ST would have agreed with SG’s comments regarding the leaking water following the path of the pipe, however, as established the site slopes from south to north  there is an absence of any other source of moisture identified by all consultants appointed to the claim, other than the leaking sewer pipe, and so ST supports the source of the heave as being the leaking sewer pipe. Determination | Case number: 677782 Page 7 of 16 Insurer’s evidence regarding cause of heave not persuasive I have carefully considered the information provided by parties and their appointed consultants. I am satisfied it clearly establishes the damage to the eastern rear half of the insured building is the result of heave due to variation of moisture levels in the subfloor foundation clay. The parties’ experts differ on the way this moisture/water has entered the subfloor area and caused the heave. SG, does not accept it is possible for the water leaking from the sewer pipe to have made its way across the subfloor area and caused heave of the foundation clay on the northern side of the building. However, in refuting this as the cause, SG has not provided any other reasonable and compelling alternative or source of the moisture. I note reference to stormwater run-off as a possible cause, however, it is clear that even SG is not reasonably confident of this suggestion. Further, it has not provided any compelling information in support of this being a possible favourable alternative cause. I would think, it is reasonable to accept, if overland stormwater run-off was the cause then it would have become evident much earlier in the life of the building, which is estimated to have been constructed in the 1980’s. There is no evidence of this and it is clear the damage subject of the claim is recent, as in became evident in April 2019. The complainant confirms having monitored the subfloor area after periods of rainfall and says there was no occasion of stormwater run-off entering the sub-floor area and introducing moisture to the foundation clays. I acknowledge SG’s reference to a lack of heave noted to the southern side of the building and that it would have expected a greater degree of heave adjacent to the leaking pipe. Given, this was not the case, SG says the leaking pipe is not the cause for the damage to the rear eastern section of the building. However, I am not convinced by this position. There is no dispute, and supported by video footage, that there was an ongoing leak from the sewer pipe allowing a fairly large volume of water to escape over an extended period of time (approximately two years). Given this, if SG’s position were to be accepted then the question arises as to why there wasn’t significant heave adjacent to the leaking pipe. Further, why wasn’t there more evidence of heave along the path of the pipe leading to the eastern boundary as suggested by SG. Again, I note the evidence is clear in establishing there was an ongoing leak resulting in an escape of significant volumes of water into the foundation clays over an extended period of time. Determination | Case number: 677782 Page 8 of 16 In the absence of significant heave to the southern side, and considering SG says the moisture could not have migrated to the northern wall, I am left wondering where does SG suppose all this leaking water travelled to. I also note SG says the foundation clays are impermeable and any migration of water through the clays would be slow. In the absence of compelling information, I am not persuaded by SG’s position which rests on a lack of heave to the southern side of the building, the clay being impermeable and it not being possible for the water to travel to the northern side of the building. It is obvious, given the leaking pipe scenario before me, that it is not necessary that heave has to be most prominent adjacent to the leak. It is possible that other factors and circumstances may impact and result in different outcomes than what would normally be expected. It has been estimated the pipe broke approximately two years prior to claim lodgement and it had been leaking since then till discovered in March 2020. So, it is reasonable to accept the insured building did not start presenting with damage until quite some time after the escape of liquid from the pipe began. I am of the opinion this supports the SG’s opin ion that migration of water through the foundation clays would be slow, as it did take quite some time to travel towards the northern section of the building. Complainant’s evidence of cause for heave reasonably persuasive I am more persuaded by the information and opinions put forward by ST a nd SS. I accept ST has reasonably shown it is possible for sub-surface water from the leaking sewer pipe to migrate through the foundation clay. Further, that this movement of sub-surface water through the subfloor has resulted in volumetric variation of the foundation clay resulting in the heave and associated damage to the rear eastern half of the insured building. I am satisfied, in the absence of any other source of water being identified and considering the large volumes of leaking water over a long period, that it is more likely than not, the heave of the foundation soils is the result of the leaking sewer pipe. In line with ST’s statements and findings , given the natural slope of the property and associated gravity, I find it is reasonable to accept the leaking subsurface water has migrated from south to north and ended up at the point of the lowest ground level. Also, that this is a reasonable and compelling explanation why there is greater heave to the northern side of the building when compared to the southern side. The insurer has not established, on balance, the application of a policy exclusion to defeat the claim. I note there is a policy provision that excludes from cover damage caused because of a gradual escape of liquid over a period of time. Determination | Case number: 677782 Page 9 of 16 However, this exclusion is subject to consideration as to whether the claimant was or a reasonable person in the circumstances could be expected to have been aware of such gradual escape of liquid. I am not satisfied there is any evidence showing the complainant was aware of could have reasonably been aware of the leaking sewer pipe on this occasion. Accordingly, for these reasons, and considering what is fair in all the circumstances, I determine the i nsurer is to accept the complainant’s claim to the extent of the heave damage to the rear eastern section of the insured building only. I note the consultants appointed to the claim consistently hold the view that before repairs can be completed the subfloor foundation will first need time to settle, that is allow for the swelling of the foundation clay to settle. Given, this I determine the insurer is to arrange for an engineer to re -attend the insured property in 12 months, or what is considered a reasonable timeframe and agreed to between the parties. This engineer is to complete the necessary assessment of the foundation clay to determine if it suitable to commence repairs. The parties are to then work together to establish the most appropriate process of repairs and costs needed to restore the rear half eastern section of the building to its condition prior to this insured event causing the internal and external damage. 2.2 Is the complainant entitled to the professional costs incurred? The insurer is to reimburse the professional costs incurred by the complainant I am satisfied the consultants’ services the complainant sourced from SS and ST have been of great assistance in reviewing this claim as well as have clearly impacted the outcome of this complaint. Accordingly, I determine within 14 days of the complainant accepting this determination, the insurer is to arrange reimbursement of all the complainant costs incurred in sourcing these professional services. In the interest of completeness, this does not include the costs incurred in repairing the damage pipe itself. 2.1 Is the complainant entitled to non-financial loss compensation? The insurer is to pay the complaint $1,500 in non-financial loss compensation I acknowledge the complainant raises issue with the insurer’s overall claim handling and the extent of time it has taken to finalise the claim. Determination | Case number: 677782 Page 10 of 16 The AFCA Rules allow for an award of up to $5,000 for non-financial loss compensation, if the insurer caused the complainant to suffer an unusual degree or extent of inconvenience, delay or interference. It is important to note such an award is based on an unusual degree or extent. This would not encompass the normal degree of inconvenience a person would suffer when lodging an insurance claim or in a dispute with their insurer. AFCA takes a conservative approach when considering any award of compensation. In this instance and considering AFCA’s conservative approach to compensation, I do accept the insurer’s over all management of the claim has contributed to an unreasonable extent of time taken to finalise the claim. Therefore, given AFCA’s approach to compensation and the available information, I determine the insurer is to arrange payment of $1,500 to the complainant by way of non-financial loss compensation. Determination | Case number: 677782 Page 11 of 16 3 Supporting information 3.1 Relevant consultants’ evidence Record Key points AL Leak Detection Report 15 June 2019  d ate of inspection was 15 June 2019  c ompleted a visual inspection of internal/external areas of the building as well as sub - floor area  i nternal areas of the home showed cracking in many areas  e xternal cracking to brick walls not ed to both nort hern and eastern sides of the building  s ub - floor area showed two cracked concrete pillars under the north east corner  r est of the sub - floor area was dry to the touch with no areas appearing to be wet around the foundations nor under suspended sewer lines  s tormwat er line that runs from south west downpipe out to the street was full of roots and had partia l blockage under the front retaining wall  s ewerage run in PVC piping and runs all along the south side of the building and discharges to the south east corner of the property. Noted a few issues: - root intrusions visible in the main line of sewer - the first was external to the hot wat er system on south side of building - second was inspected at south east corner of building  all lines of suspended sewer lines were found to be in good condition  recommended appointment of engineer to assess cause and extent of da mage noted to the building. SG Forensi c Engineering Inspection Report 24 July 2019  date of inspection 15 July 2019  inspection was visual only and not invasive investigation was undertaken, unless otherwis e stated in the report  natural ground of the property slopes from south to north (front of the property faces West and rear of property east)  noticeable upward bulge on window sill and eaves line above bedroom on north side of building  a gap, approximately 30mm, noted between concrete slab (driveway ) and nort hern wall of the building  concrete slab sloped away from the building  large shrinkage cracks noted in sub - floor surface  lowest point of the sub - floor is the north east corner of the house under bedroom 2  there was evidence of past wat er stainin g to northern wall at the lowest point, however, at time of inspection sub - floor was dry  noted failure of two concret e stumps under bedroom 2. The stumps appeared to have been pus hed out of the ground  a tall treed noted at front of the property and some sm aller shrubs. Determination | Case number: 677782 Page 12 of 16 Record Key points In SG’s opinion the roots from this vegetation have exacerbat ed the seasonal moisture changes in the natural clay inducing long term shrinkage and settlement at western side of the building resulting in lower floor levels  the cracked stumps i ndicate that they have been pushed up out of the ground due to clay heave  external/internal cracking and sticking of doors also indicate there has been heave at the rear of the building  plumbing investigations by AL found some issues with the underground sewer pipe at the south side of the building  however, SG says, if there was escape of liquid occurring from this pipe, it would have expected to have sighted moisture in the sub - floor at the time of inspection  therefore, SG provides opinion, that there had not been no escape of liquid from the sewer pipes that could have caused the damage noted to the building  SG says it is possible, given the natural slope of the property, that stormwat er flow has entered the sub - floor through the south side brick wall an d tracked ac ross the sub - floor to north east corner  given the driveway slopes away from the building, SG is of the view any water entering the gap between the driveway and building is not the cause of the clay heave on north side. ST Forensic Engineering Building Investigation Report 15 October 2019  date of inspection 2 October 2019  single storey home likely constructed in 1980’s  complainant advised large cracks to northern external wall first noticed approximately 6 months prior and have gotten wides sin ce then  noted vast number of int ernal cracks in various locations  soil conditions consisted of clay and typically assessed as Class H2 to E  site slopes from south to north and west to east  large Gum tree (around 12m high) located approximat ely 9 - 10m from the front of the building  a tree approximately 5m located around 2m from the kitchen external wall  inspected the sub - floor beneath the rear half of the building with north east corner not ed as being the lowest ground level  area inspected was dr y at the surface and had shrinkage cracks  efflorescence noted across surface of the sub - floor and 1 - 3 coursed of bricks to external walls  soil was excavat ed adjacent to bedrooms 2 and 3 external walls and it was noted to be wetter at a dept h of 150 - 200mm  n oted two stumps were cracked  survey indicated the pattern of floor/slab movement to indicate edge heave at the northern wall and edge drying at western wall  higher slab levels were noted in the laundry, WC, bedroom 2 and 3. This pattern co - relates with th e soil reactive response due to swell of the foundation clay  lower slab levels not ed in the kitchen, dining, entry, games and Determination | Case number: 677782 Page 13 of 16 Record Key points living room. This pattern co - relates with clay reactive res ponse due to shrinking of the foundation clay  volumetric variations of the underlying clay foundation is the main cause of observed damage. Volumetric variations of clay occurs with changes in moisture content. Clay soils shrink as a result of drying and swell when becomes moist  the pattern of cracking and floor levels indica te the north east side of the building has risen relative to the remainder of the residence, particularly at bedroom 2 and 3’s windows  the efflorescence noted on the ground under the floor indicates there has been water present in the area  it is possible water leaking from sewer pipe has seeped under the southern external wall and flowed with gravity to the nort hern external wall and strip footing  this subsurface wat er will have created an abnormal moisture condition inc reasing the volumetric variations  S T formed the opinion it was unlikely that the water creating the abnormal moisture conditions was from overland stormwater flow as suggested by SG  It is ST’s opinion that it is subsurface water that is causing the abnormal moisture condition. SG Forensi c Engineering Supplementary Report 11 November 2019  SG’s reference to stormwater run - off as being a cause in the first report was only put forward as a ‘possible’ scenario only  It is SG’s opinion that clay heave caused by an escape of liquid fro m an underground pipe occurs directly adjacent to the source of the escape  clay is relatively impermeable mat erial and subsurface waterflow through clay is slow  therefore, effects of heave would be great est around the source of the water leak and decrease as one goes further away from the source  therefore, SG says it is unlikely that some possible water seepage through a sewer pipe joint with tree root intrusion would result in subsurface water flow through relatively impermeable clay  therefore, continues t o maintain opinion that water leaking from the sewer pipe on southern side of the building is not the cause of clay heave on north side of the building. SS Plumbing Report/Invoice March 2020  attended 5 March 2020 to excavate and repair an existing damaged sewer pipe at southeast corner of the dwelling  whilst excavating found soil surrounding the broken pipe considerably wetter than soil closer to the surface  discovered the PVC pipe had sheared all the way around and opened up approximately 1.5cm  the re was a section of tree root intrusion  judging by the amount of tree root pres ent, SS believes that the pipe may have broken within the last two years  had it been earlier than this, SS says the sewer would have been overrun with tree roots and possibly bl ocked and overflowed. Determination | Case number: 677782 Page 14 of 16 Record Key points SG Forensi c Engi neering Supplementary Report – 2 2 April 2020  the video from the complainant confirms crack/gap in the sewer pipe on southern side of the building  conclusions in previous reports remain unchanged i.e. water leaking on the south side of the building has not caused the clay heave at northern side under bedrooms 2 and 3  SG says ST did not say there was water under the house. The pit excavated adjacent to the northern wall shows no sign of water at the base of the pit  the soil colour is darker at the base which indicates increased moisture compared to the dry surface conditions  however, it is normal for increased moisture in the soil with dept hs. ST Letter of response 24 April 2020  the floor level survey shows entire e astern half of the building has higher floor levels when compared to the datum point  the highest levels are located along the northern wall  regarding SG’s comments about lack of damage to south side of the building, ST notes cracking in external brickwork and internal plaster was observed throughout the building including the southern side  maintains the opinion, slow migration of water through the clay soil from southern side to the northern side is possible. Further, it is subsurface water causing the abno rmal moisture conditions  there have not been any other source(s) of water identified by any of the consultants appointed to the claim  efflorescence was noted to surface of most of the subfloor soil, including the southern side of the house, indicating wat er is or has been present  there is a tree outside the southern wall of bedroom 1 and other trees close to the fence line with neighbouring property. It is possible these trees are drawing moisture from the soil on the southern side resulting in less heave  as no other source, ST says it is likely water from the leaking sewer pipe is the source of the heave and resultant damage to the eastern half of the building. SG Forensi c Engineering Supplementary Report – 3 5 May 2020  SG disagrees with ST’s reference to trees on south side of the building. Says it is impossible for trees to absorb excess moisture on the southern side yet at the same time allowing moisture to pass through the same clay that is said to be causing substantial heave on northern side  regard ing ST’s reference to internal and external cracking to the southern side, SG says this damage on the southern side is typical for a 1980’s build house on shallow footings  the floor levels to the southern side do not indicate substantial movement in this s ector and are within normal tolerances for and typical for an 80’s house with shallow footings  SG is of the opinion, that water leaking from the sewer pipe would have followed the path of least resistance and followed the path of the pipe towards the east ern boundary and not north. Determination | Case number: 677782 Page 15 of 16 Record Key points ST Email response 15 May 2020  ST says if the site was flat, then it would agree with SG. However, the site slopes from south to north  It is possible for wat er to migrate beneath the shallow southern footing to the northern footings  if the house was built today, it would have had 850mm footings and articulation joints in the brickwork  the fact remains, there has not been any other source of moisture identified by SG or any other consultant appointed to the claim. 3.2 Relevant policy wording 11. Water or other liquid damage (Applicable whether you have buildings and/or contents cover) We will pay for loss or damage which results directly from the bursting, leaking, discharging or overflowing of: • fixed apparatus, • dishwash ers, • washing machines, • fixed tanks, • fixed pipes, • waterbeds, or • aquariums designed to hold more than 20 litres of water. If you have buildings cover and we have agreed to pay a claim for water or other liquid damage, we will also pay the reasonable cost of locating the source of the damage. We will not pay: a. for loss or damage caused as a result of the gradual escape of liquid over a period of time: • where you or a reasonable person in the circumstances could be expected to have been aware of such gradual escape of liquid, Determination | Case number: 677782 Page 16 of 16 … When we will not pay a claim under your policy … 2. Unless we state differently in your policy, we will not pay for: … b. any loss or damage which is not caused directly by one of the insured events 3.3 AFCA’s approach to this complaint This complaint has been determined based on what is fair in all the circumstances, having regard to the relevant law, good industry practice, codes of practice and previous decisions of AFCA or its predecessor schemes (which are not binding). A full exchange of the relevant information has taken place between the respective parties. Each party has had the opportunity of addressing any issues raised. All the provided material has been reviewed and considered. The parties have rai sed numerous issues in their submissions to AFCA. However, commentary in this determination is restricted only to those issues considered relevant to the outcome.

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.