Text of the determination
Determination
Case number 677782
Financial firm Allianz Australia Insurance Limited
Determination | Case number: 677782 Page 2 of 16
Case number: 677782 31 August 2020
1 Determination overview
1.1 Complaint
The complainants hold a policy with the financial firm (insurer) to insure their home
and contents. The policy provides cover for loss or damage to the insured property
from listed insured events specified in the product disclosure statement (PDS),
subject to the limitations and exclusions also provided in the PDS.
On 31 May 2019, the complainants lodged a claim for extensive damage to the
insured building said to be caused by liquid leaking from a broken sewer pipe. The
insurer declined the claim, saying the complaints had not shown the damage claimed
was due to an insured event.
1.2 Issues and key findings
Is the insurer liable for the claim?
The complainants have established, on balance, the escape of liquid from the leaking
sewer pipe has caused some of the damaged claimed. This constitutes an insured
event under the policy. The insurer has not shown that exclusions apply to allow it to
decline liability for the full extent of the claim.
Is the insurer liable for the complainants’ professional costs?
The insurer is to cover the complainants for professional expenses incurred in
investigating and quantifying the cause of damage. However, this does not include
costs incurred in repairing the damaged sewer pipe.
Are the complainants entitled to compensation for non-financial loss?
The insurer’s overall management of this claim has resulted in an unusual and
unreasonable delay causing the complainants stress and inconvenience, and so it is
to pay the complainants $1,500 in non-financial loss compensation in line with the
AFCA Rules.
1.3 Determination
This determination is substantially in favour of the complainants.
The insurer is to cover the complainant for the cost of repairs associated with the rear
eastern section of the insured building. The insurer is to reimburse the professional
costs incurred by the complainants in line with this determination. Further, the insurer
is to pay the complainants $1,500 in compensation for non-financial loss.
Determination | Case number: 677782 Page 3 of 16
2 Reasons for determination
2.1 Is the insurer liable for the claim?
The complainants bear the onus to show the damage claimed is covered
It is established law, to seek cover under the policy the onus first rests on the claimant
to establish, on the balance of probabilities, the loss claimed is covered by the terms
of the policy.
Only once this has been established, will the onus shift to the insurer to establish, on
balance, that it is not responsible to cover the claimant for the loss in line with a policy
provision or exclusion.
The complainants have sought the assi stance of ‘DC’ in bringing this complainant
before AFCA. For this determination, reference to the complainant includes both the
complainants and DC.
The policy is an insured events contract of insurance
The policy covers the insured building and contents against loss or damage caused
by one or more of the listed insured events specified in the PDS. Cover under the
policy benefits are subject to the limitation and exclusion provisions also provided in
the PDS.
Relevant to the consideration of this complaint, the policy includes the insured event
Water or other liquid damage. Under this policy benefit the complainant is covered for
loss or damage which results directly from the bursting, leaking, discharging or
overflowing of various listed sources including fixed pipes.
The policy also extends to cover the reasonable costs incurred in locating the source
of damage to the insured property.
The complainant in around April 2019 noted internal and external cracking to the bri ck
walls and plaster at the insured property. In May 2019, the complainant noted the
cracking was getting increasingly worse and for which a claim was lodged under the
policy on or about 31 May 2019.
The complainant is of the view the damage is the result of a leaking sewer pipe
located by plumbing consultants ‘SS’ and supported by engineering consultants ‘ST’
appointed by the complainant.
The insurer, however, says it is entitled to decline the claim as it says the damage to
the insured building is not the result of an insured event. Therefore, in line with the
policy, the complainant has not established a prima facie claim. The insurer relies on
the evidence provide by engineering consultants ‘SG’, it appointed to the claim.
Determination | Case number: 677782 Page 4 of 16
Damage to the front western section of the building is excluded
The parties to this complaint do not dispute there exists extensive internal and
external cracking damage, which varies in severity, in most areas of the insured
building.
There is no dispute that there exists a clear distinction in the proximate cause for the
damage to the front western half of the home compared to the rear eastern half of the
home.
Both parties to the complaint agreed the damage to the front western half of the
building is not covered as this is not the result of an insured event to which the policy
responds.
Rather, this damage is the result of ongoing gradual subsidence and resultant fall in
the floor levels. This is, on balance, related to vegetation located in close proximity to
the front of the insured building. These are not circumstances which trigger cover
under the policy.
This complaint relates to the damage noted to the rear eastern half of the insured
building. The parties differ in their opinion as to the proximate cause for this damage.
In saying that, both parties agree, the damage is the result of volumetric variation of
the underlying clay foundation soils (clay). This occurs with changes in the moisture
content of the clay, in this case introduction of moisture and resultant swelling of the
clay (heave).
Evidence shows, on balance, escape of liquid is the cause for the damage
The parties both heavily rely on the opinions put forward by their appointed
consultants, who have each provided multiple reports/communications in support of
their positions. The relevant information from these reports and communications has
been provided in section 3 of this determination.
As noted above, both parties accept the damage is the result of heave and this is due
to an introduction of moisture into the foundation clay located in the subfloor area of
the home. The complainant says this introduction of moisture is the result of a leaking
subsurface sewer pipe found to the southern side of the building next to the hot water
system.
The insurer, however, says the damage could not be the result of the leaking sewer
pipe and it may possibly be the result of overland stormwater run-off. It says the
complainant has not been successful in establishing the damage is the result of an
insured event and as such it is has declined the claim in its entirety.
Evidence relied on by the insurer
The insurer in seeking to decline the claim for the most part relies on information
provided by its appointed engineering consultants SG. I have considered the reports
Determination | Case number: 677782 Page 5 of 16
from SG and am satisfied, on balance, SG relies on the following findings and
opinions:
the ground at the insured property naturally slopes from south to north
it found a noticeable upward bulge to window sills and eave linings above bedroom
windows on the northern side of the building
there was a gap of around 30mm between the driveway concrete slab and the
northern external brick wall of the building
the subfloor clay presented with shrinkage cracks and was found to be dry at
surface level. The lowest point of the subfloor area is in the northern eastern corner
under bedroom 2
there were two damaged concrete stumps under bedroom 2 which appeared to
have been pushed out of the ground, consistent with clay heave
the clay heave has not been caused by any issues with the leaking sewer pipe
located on the southern side of the building. If it had been, SG would have
expected to notice moisture in the subfloor area at the time of its inspection
clay is relatively impermeable material and any instance of subsurface waterflow
through clay would be very slow. Gi ven this, any effects of heave would be
greatest near the leaking pipe itself, which was not the case in this instance
the variation in floor levels noted at the southern side of the building were normal
for a building constructed in the 1980’s and built on shallow footings
water leaking form the sewer pipe would have followed the path of least resistance,
which in this instance, would have been to follow the path of the pipe down the
southern side of the building towards the eastern boundary, not northwards
it would be impossible for vegetation located near to the southside external wall to
have absorbed excess moisture and prevent excessive heave, yet at the same
time allow moisture to travel towards the northern wall
it is possible, the moisture resulting in the heave is the result of stormwater run-off
entering the subfloor area through the southern brick wall due to the natural slope
of the property.
On this basis, the insurer says the complainant has not established the leaking sewer
pipe is the cause for the damage claimed. Further, that the complainant has not
shown the damage is the direct result of any of the listed insured everts. So, the
insurer maintains it is entitled to decline the claim.
Evidence relied on by the complainant
The complainant relies on information provided by his appointed plumbing and
engineering consultants. I note SS (plumbers), were appointed midway through the
claim and after SG and ST had attended to complete their investigations into the
cause and extent of the damage claimed.
Determination | Case number: 677782 Page 6 of 16
SS attended the insured property on 5 March 2020 to excavate and repair an existing
damaged sewer pipe, located on the south side of the building. While excavating the
location it found the soil surrounding the broken pipe to be considerably wetter than
the soil closer to the surface. It found the sewer PVC pipe had sheared all the way
around and had opened up approximately 1.5cm.
There was some tree root intrusion, which by the amount, SS formed the view the
pipe may have broken within the last two years. If it had been earlier than this, SS
would have expected the pipe to have been overrun with tree roots and be blocked.
I have reviewed the report and communications from engineering consultants ST and
am satisfied, on balance, they came to the following opinions and conclusions:
ST attended on 2 October 2019, to complete its investigations at the insured
property
the soil conditions consisted of clay and were typically assessed as Class H2 to E.
The site sloped from south to north and then again from west to east
inspected the subfloor beneath the rear half of the building and noted the northeast
corner as being the lowest ground level
the area seemed dry and at the surface and had shrinkage cracks. ST noted
presence of efflorescence over most of the subfloor area and bottom one to three
courses of bricks of the external walls. This is indicative of water having been in the
area
ST excavated adjacent to bedroom 2 and 3 external wall, where most significant
heave was evident, and at a depth of 150-200mm found the clay to be wetter
it is possible water leaking from the sewer pipe has seeped through the subfloor
clays flowing with gravity to the northern external wall and strip footing. This will
have resulted in an abnormal moisture condition increasing the volumetric
variations
ST strongly holds the view that it is subsurface water that has caused the abnormal
moisture conditions. Further, that it is unlikely to be overland stormwater flo w as
suggested
the floor level survey completed shows the entire eastern half of the building has
higher floor levels including the southern side, with the highest levels noted under
bedroom 2 and 3. This shows a migration of water through the clay soils from the
southern side to northern side
if the site was flat, ST would have agreed with SG’s comments regarding the
leaking water following the path of the pipe, however, as established the site
slopes from south to north
there is an absence of any other source of moisture identified by all consultants
appointed to the claim, other than the leaking sewer pipe, and so ST supports the
source of the heave as being the leaking sewer pipe.
Determination | Case number: 677782 Page 7 of 16
Insurer’s evidence regarding cause of heave not persuasive
I have carefully considered the information provided by parties and their appointed
consultants. I am satisfied it clearly establishes the damage to the eastern rear half of
the insured building is the result of heave due to variation of moisture levels in the
subfloor foundation clay.
The parties’ experts differ on the way this moisture/water has entered the subfloor
area and caused the heave.
SG, does not accept it is possible for the water leaking from the sewer pipe to have
made its way across the subfloor area and caused heave of the foundation clay on
the northern side of the building. However, in refuting this as the cause, SG has not
provided any other reasonable and compelling alternative or source of the moisture.
I note reference to stormwater run-off as a possible cause, however, it is clear that
even SG is not reasonably confident of this suggestion. Further, it has not provided
any compelling information in support of this being a possible favourable alternative
cause.
I would think, it is reasonable to accept, if overland stormwater run-off was the cause
then it would have become evident much earlier in the life of the building, which is
estimated to have been constructed in the 1980’s. There is no evidence of this and it
is clear the damage subject of the claim is recent, as in became evident in April 2019.
The complainant confirms having monitored the subfloor area after periods of rainfall
and says there was no occasion of stormwater run-off entering the sub-floor area and
introducing moisture to the foundation clays.
I acknowledge SG’s reference to a lack of heave noted to the southern side of the
building and that it would have expected a greater degree of heave adjacent to the
leaking pipe. Given, this was not the case, SG says the leaking pipe is not the cause
for the damage to the rear eastern section of the building.
However, I am not convinced by this position. There is no dispute, and supported by
video footage, that there was an ongoing leak from the sewer pipe allowing a fairly
large volume of water to escape over an extended period of time (approximately two
years).
Given this, if SG’s position were to be accepted then the question arises as to why
there wasn’t significant heave adjacent to the leaking pipe. Further, why wasn’t there
more evidence of heave along the path of the pipe leading to the eastern boundary as
suggested by SG.
Again, I note the evidence is clear in establishing there was an ongoing leak resulting
in an escape of significant volumes of water into the foundation clays over an
extended period of time.
Determination | Case number: 677782 Page 8 of 16
In the absence of significant heave to the southern side, and considering SG says the
moisture could not have migrated to the northern wall, I am left wondering where does
SG suppose all this leaking water travelled to. I also note SG says the foundation
clays are impermeable and any migration of water through the clays would be slow.
In the absence of compelling information, I am not persuaded by SG’s position which
rests on a lack of heave to the southern side of the building, the clay being
impermeable and it not being possible for the water to travel to the northern side of
the building.
It is obvious, given the leaking pipe scenario before me, that it is not necessary that
heave has to be most prominent adjacent to the leak. It is possible that other factors
and circumstances may impact and result in different outcomes than what would
normally be expected.
It has been estimated the pipe broke approximately two years prior to claim
lodgement and it had been leaking since then till discovered in March 2020. So, it is
reasonable to accept the insured building did not start presenting with damage until
quite some time after the escape of liquid from the pipe began.
I am of the opinion this supports the SG’s opin ion that migration of water through the
foundation clays would be slow, as it did take quite some time to travel towards the
northern section of the building.
Complainant’s evidence of cause for heave reasonably persuasive
I am more persuaded by the information and opinions put forward by ST a nd SS. I
accept ST has reasonably shown it is possible for sub-surface water from the leaking
sewer pipe to migrate through the foundation clay.
Further, that this movement of sub-surface water through the subfloor has resulted in
volumetric variation of the foundation clay resulting in the heave and associated
damage to the rear eastern half of the insured building.
I am satisfied, in the absence of any other source of water being identified and
considering the large volumes of leaking water over a long period, that it is more likely
than not, the heave of the foundation soils is the result of the leaking sewer pipe.
In line with ST’s statements and findings , given the natural slope of the property and
associated gravity, I find it is reasonable to accept the leaking subsurface water has
migrated from south to north and ended up at the point of the lowest ground level.
Also, that this is a reasonable and compelling explanation why there is greater heave
to the northern side of the building when compared to the southern side.
The insurer has not established, on balance, the application of a policy exclusion to
defeat the claim. I note there is a policy provision that excludes from cover damage
caused because of a gradual escape of liquid over a period of time.
Determination | Case number: 677782 Page 9 of 16
However, this exclusion is subject to consideration as to whether the claimant was or
a reasonable person in the circumstances could be expected to have been aware of
such gradual escape of liquid.
I am not satisfied there is any evidence showing the complainant was aware of could
have reasonably been aware of the leaking sewer pipe on this occasion.
Accordingly, for these reasons, and considering what is fair in all the circumstances, I
determine the i nsurer is to accept the complainant’s claim to the extent of the heave
damage to the rear eastern section of the insured building only.
I note the consultants appointed to the claim consistently hold the view that before
repairs can be completed the subfloor foundation will first need time to settle, that is
allow for the swelling of the foundation clay to settle.
Given, this I determine the insurer is to arrange for an engineer to re -attend the
insured property in 12 months, or what is considered a reasonable timeframe and
agreed to between the parties. This engineer is to complete the necessary
assessment of the foundation clay to determine if it suitable to commence repairs.
The parties are to then work together to establish the most appropriate process of
repairs and costs needed to restore the rear half eastern section of the building to its
condition prior to this insured event causing the internal and external damage.
2.2 Is the complainant entitled to the professional costs incurred?
The insurer is to reimburse the professional costs incurred by the complainant
I am satisfied the consultants’ services the complainant sourced from SS and ST
have been of great assistance in reviewing this claim as well as have clearly impacted
the outcome of this complaint.
Accordingly, I determine within 14 days of the complainant accepting this
determination, the insurer is to arrange reimbursement of all the complainant costs
incurred in sourcing these professional services.
In the interest of completeness, this does not include the costs incurred in repairing
the damage pipe itself.
2.1 Is the complainant entitled to non-financial loss compensation?
The insurer is to pay the complaint $1,500 in non-financial loss compensation
I acknowledge the complainant raises issue with the insurer’s overall claim handling
and the extent of time it has taken to finalise the claim.
Determination | Case number: 677782 Page 10 of 16
The AFCA Rules allow for an award of up to $5,000 for non-financial loss
compensation, if the insurer caused the complainant to suffer an unusual degree or
extent of inconvenience, delay or interference.
It is important to note such an award is based on an unusual degree or extent. This
would not encompass the normal degree of inconvenience a person would suffer
when lodging an insurance claim or in a dispute with their insurer.
AFCA takes a conservative approach when considering any award of compensation.
In this instance and considering AFCA’s conservative approach to compensation, I do
accept the insurer’s over all management of the claim has contributed to an
unreasonable extent of time taken to finalise the claim.
Therefore, given AFCA’s approach to compensation and the available information, I
determine the insurer is to arrange payment of $1,500 to the complainant by way of
non-financial loss compensation.
Determination | Case number: 677782 Page 11 of 16
3 Supporting information
3.1 Relevant consultants’ evidence
Record Key points
AL Leak Detection Report
15 June 2019
d ate of inspection was 15 June 2019
c ompleted a visual inspection of internal/external areas of the
building as well as sub - floor area
i nternal areas of the home showed cracking in many areas
e xternal cracking to brick walls not ed to both nort hern and eastern
sides of the building
s ub - floor area showed two cracked concrete pillars under the
north east corner
r est of the sub - floor area was dry to the touch with no areas
appearing to be wet around the foundations nor under suspended
sewer lines
s tormwat er line that runs from south west downpipe out to the
street was full of roots and had partia l blockage under the front
retaining wall
s ewerage run in PVC piping and runs all along the south side of
the building and discharges to the south east corner of the
property. Noted a few issues:
- root intrusions visible in the main line of sewer
- the first was external to the hot wat er system on south
side of building
- second was inspected at south east corner of building
all lines of suspended sewer lines were found to be in good
condition
recommended appointment of engineer to assess cause and
extent of da mage noted to the building.
SG Forensi c Engineering
Inspection Report
24 July 2019
date of inspection 15 July 2019
inspection was visual only and not invasive investigation was
undertaken, unless otherwis e stated in the report
natural ground of the property slopes from south to north (front of
the property faces West and rear of property east)
noticeable upward bulge on window sill and eaves line above
bedroom on north side of building
a gap, approximately 30mm, noted between concrete slab
(driveway ) and nort hern wall of the building
concrete slab sloped away from the building
large shrinkage cracks noted in sub - floor surface
lowest point of the sub - floor is the north east corner of the house
under bedroom 2
there was evidence of past wat er stainin g to northern wall at the
lowest point, however, at time of inspection sub - floor was dry
noted failure of two concret e stumps under bedroom 2. The
stumps appeared to have been pus hed out of the ground
a tall treed noted at front of the property and some sm aller shrubs.
Determination | Case number: 677782 Page 12 of 16
Record Key points
In SG’s opinion the roots from this vegetation have exacerbat ed
the seasonal moisture changes in the natural clay inducing long
term shrinkage and settlement at western side of the building
resulting in lower floor levels
the cracked stumps i ndicate that they have been pushed up out of
the ground due to clay heave
external/internal cracking and sticking of doors also indicate there
has been heave at the rear of the building
plumbing investigations by AL found some issues with the
underground sewer pipe at the south side of the building
however, SG says, if there was escape of liquid occurring from this
pipe, it would have expected to have sighted moisture in the sub -
floor at the time of inspection
therefore, SG provides opinion, that there had not been no escape
of liquid from the sewer pipes that could have caused the damage
noted to the building
SG says it is possible, given the natural slope of the property, that
stormwat er flow has entered the sub - floor through the south side
brick wall an d tracked ac ross the sub - floor to north east corner
given the driveway slopes away from the building, SG is of the
view any water entering the gap between the driveway and
building is not the cause of the clay heave on north side.
ST Forensic Engineering
Building Investigation
Report
15 October 2019
date of inspection 2 October 2019
single storey home likely constructed in 1980’s
complainant advised large cracks to northern external wall first
noticed approximately 6 months prior and have gotten wides sin ce
then
noted vast number of int ernal cracks in various locations
soil conditions consisted of clay and typically assessed as Class
H2 to E
site slopes from south to north and west to east
large Gum tree (around 12m high) located approximat ely 9 - 10m
from the front of the building
a tree approximately 5m located around 2m from the kitchen
external wall
inspected the sub - floor beneath the rear half of the building with
north east corner not ed as being the lowest ground level
area inspected was dr y at the surface and had shrinkage cracks
efflorescence noted across surface of the sub - floor and 1 - 3
coursed of bricks to external walls
soil was excavat ed adjacent to bedrooms 2 and 3 external walls
and it was noted to be wetter at a dept h of 150 - 200mm
n oted two stumps were cracked
survey indicated the pattern of floor/slab movement to indicate
edge heave at the northern wall and edge drying at western wall
higher slab levels were noted in the laundry, WC, bedroom 2 and
3. This pattern co - relates with th e soil reactive response due to
swell of the foundation clay
lower slab levels not ed in the kitchen, dining, entry, games and
Determination | Case number: 677782 Page 13 of 16
Record Key points
living room. This pattern co - relates with clay reactive res ponse
due to shrinking of the foundation clay
volumetric variations of the underlying clay foundation is the main
cause of observed damage. Volumetric variations of clay occurs
with changes in moisture content. Clay soils shrink as a result of
drying and swell when becomes moist
the pattern of cracking and floor levels indica te the north east side
of the building has risen relative to the remainder of the residence,
particularly at bedroom 2 and 3’s windows
the efflorescence noted on the ground under the floor indicates
there has been water present in the area
it is possible water leaking from sewer pipe has seeped under the
southern external wall and flowed with gravity to the nort hern
external wall and strip footing
this subsurface wat er will have created an abnormal moisture
condition inc reasing the volumetric variations
S T formed the opinion it was unlikely that the water creating the
abnormal moisture conditions was from overland stormwater flow
as suggested by SG
It is ST’s opinion that it is subsurface water that is causing the
abnormal moisture condition.
SG Forensi c Engineering
Supplementary Report
11 November 2019
SG’s reference to stormwater run - off as being a cause in the first
report was only put forward as a ‘possible’ scenario only
It is SG’s opinion that clay heave caused by an escape of liquid
fro m an underground pipe occurs directly adjacent to the source of
the escape
clay is relatively impermeable mat erial and subsurface waterflow
through clay is slow
therefore, effects of heave would be great est around the source of
the water leak and decrease as one goes further away from the
source
therefore, SG says it is unlikely that some possible water seepage
through a sewer pipe joint with tree root intrusion would result in
subsurface water flow through relatively impermeable clay
therefore, continues t o maintain opinion that water leaking from
the sewer pipe on southern side of the building is not the cause of
clay heave on north side of the building.
SS Plumbing Report/Invoice
March 2020
attended 5 March 2020 to excavate and repair an existing
damaged sewer pipe at southeast corner of the dwelling
whilst excavating found soil surrounding the broken pipe
considerably wetter than soil closer to the surface
discovered the PVC pipe had sheared all the way around and
opened up approximately 1.5cm
the re was a section of tree root intrusion
judging by the amount of tree root pres ent, SS believes that the
pipe may have broken within the last two years
had it been earlier than this, SS says the sewer would have been
overrun with tree roots and possibly bl ocked and overflowed.
Determination | Case number: 677782 Page 14 of 16
Record Key points
SG Forensi c Engi neering
Supplementary Report – 2
2 April 2020
the video from the complainant confirms crack/gap in the sewer
pipe on southern side of the building
conclusions in previous reports remain unchanged i.e. water
leaking on the south side of the building has not caused the clay
heave at northern side under bedrooms 2 and 3
SG says ST did not say there was water under the house. The pit
excavated adjacent to the northern wall shows no sign of water at
the base of the pit
the soil colour is darker at the base which indicates increased
moisture compared to the dry surface conditions
however, it is normal for increased moisture in the soil with dept hs.
ST Letter of response
24 April 2020
the floor level survey shows entire e astern half of the building has
higher floor levels when compared to the datum point
the highest levels are located along the northern wall
regarding SG’s comments about lack of damage to south side of
the building, ST notes cracking in external brickwork and internal
plaster was observed throughout the building including the
southern side
maintains the opinion, slow migration of water through the clay soil
from southern side to the northern side is possible. Further, it is
subsurface water causing the abno rmal moisture conditions
there have not been any other source(s) of water identified by any
of the consultants appointed to the claim
efflorescence was noted to surface of most of the subfloor soil,
including the southern side of the house, indicating wat er is or has
been present
there is a tree outside the southern wall of bedroom 1 and other
trees close to the fence line with neighbouring property. It is
possible these trees are drawing moisture from the soil on the
southern side resulting in less heave
as no other source, ST says it is likely water from the leaking
sewer pipe is the source of the heave and resultant damage to the
eastern half of the building.
SG Forensi c Engineering
Supplementary Report – 3
5 May 2020
SG disagrees with ST’s reference to trees on south side of the
building. Says it is impossible for trees to absorb excess moisture
on the southern side yet at the same time allowing moisture to
pass through the same clay that is said to be causing substantial
heave on northern side
regard ing ST’s reference to internal and external cracking to the
southern side, SG says this damage on the southern side is typical
for a 1980’s build house on shallow footings
the floor levels to the southern side do not indicate substantial
movement in this s ector and are within normal tolerances for and
typical for an 80’s house with shallow footings
SG is of the opinion, that water leaking from the sewer pipe would
have followed the path of least resistance and followed the path of
the pipe towards the east ern boundary and not north.
Determination | Case number: 677782 Page 15 of 16
Record Key points
ST Email response
15 May 2020
ST says if the site was flat, then it would agree with SG. However,
the site slopes from south to north
It is possible for wat er to migrate beneath the shallow southern
footing to the northern footings
if the house was built today, it would have had 850mm footings
and articulation joints in the brickwork
the fact remains, there has not been any other source of moisture
identified by SG or any other consultant appointed to the claim.
3.2 Relevant policy wording
11. Water or other liquid damage
(Applicable whether you have buildings and/or contents cover)
We will pay for loss or damage which results directly from the bursting, leaking,
discharging or overflowing of:
• fixed apparatus,
• dishwash ers,
• washing machines,
• fixed tanks,
• fixed pipes,
• waterbeds, or
• aquariums designed to hold more than 20 litres of water.
If you have buildings cover and we have agreed to pay a claim for water or other
liquid damage, we will also pay the reasonable cost of locating the source of the
damage.
We will not pay:
a. for loss or damage caused as a result of the gradual escape of liquid over a
period of time:
• where you or a reasonable person in the circumstances could be expected to
have been aware of such gradual escape of liquid,
Determination | Case number: 677782 Page 16 of 16
…
When we will not pay a claim under your policy
…
2. Unless we state differently in your policy, we will not pay for:
…
b. any loss or damage which is not caused directly by one of the insured events
3.3 AFCA’s approach to this complaint
This complaint has been determined based on what is fair in all the circumstances,
having regard to the relevant law, good industry practice, codes of practice and
previous decisions of AFCA or its predecessor schemes (which are not binding).
A full exchange of the relevant information has taken place between the respective
parties. Each party has had the opportunity of addressing any issues raised.
All the provided material has been reviewed and considered. The parties have rai sed
numerous issues in their submissions to AFCA. However, commentary in this
determination is restricted only to those issues considered relevant to the outcome.
Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.