Landlord policy claim for water damage after August 2019 storm partly declined as construction defect and failure to maintain

FirmSuncorp Group
Decided2020-05-18
ProductGeneral Insurance · Landlord
OutcomeFor the complainant in part
Amount awarded—
Non-financial loss—
Amount claimed—
SourceAFCA PDF

Summary

The complainant's landlord policy claim for water damage after an August 2019 storm was partly declined because the insurer said the ceiling damage was not from a single storm and the leaks were due to construction defects or failure to maintain. AFCA ordered the insurer to indemnify the resultant ceiling damage on receipt of repair invoices, with statutory interest, but not the cost of rectifying the leaks.

The policy covers resultant damage from an unknown defect the insured was not reasonably aware of, and the failure to maintain exclusion cannot apply to defects the landlord could not reasonably have known about.

Issues

Subjects and remedies

home or building damagenatural disasterpay claimpay interest

Related

All Suncorp Group determinations · Find similar determinations

Text of the determination

Determination Case number 675618 Financial firm AAI Limited Determination | Case number: 675618 Page 2 of 11 Case number: 675618 15 May 2020 1 Determination overview 1.1 Complaint The complainant claimed for water damage to his rental property under his landlord policy with the financial firm (insurer), following a storm around 9 – 11 August 2019 (August 2019 storm). The insurer accepted liability for water damage to a bedroom ceiling, but not for:  water damage to the property’s kitchen and garage ceiling  repairing the sources of the leaks into the property, said to be the balcony and roof. The insurer later said it would reconsider the kitchen ceiling damage as a separate claim, under the ‘Escape of liquid’ section of the policy. The insurer otherwise maintains denial of the garage ceiling damage and the leaks, saying they were:  not caused by an insured event or single storm event  due to a construction defect and/or a failure to maintain the property. The complainant believes he is entitled to indemnity for the cost of repairing all resultant water damage and the leaks, as he was unaware of the leaks. 1.2 Issue and key findings Is the insurer entitled to decline the claim for the disputed matters? The insurer is entitled to decline the cost of repair ing the property’s leaks, but not its resultant water damage. On the balance of probabilities:  the garage and bedroom ceiling were damaged by the August 2019 storm due to design or construction defects the complainant was unlikely aware of  the kitchen ceiling was damaged by water escaping a gutter box through a defect the complainant was unlikely reasonably aware of  the policy covers resultant damage when a person is unaware of such defects  the leaks into the property were not caused by an event the policy covers. 1.3 Determination This determination is partly in favour of the complainant. The insurer is to indemnify the complainant for the resultant ceiling damage to his property and take the steps outlined in section 2.1 of the determination. Determination | Case number: 675618 Page 3 of 11 2 Reasons for determination 2.1 Is the insurer entitled to decline the claim for the disputed matters? I have decided this case on its merits, having regard to the relevant law, good industry practice, codes of practice, previous AFCA decisions and fairness. I have considered all material submitted by the parties, before and after the preliminary assessment. I am satisfied the documentation I have relied on has been provided to both parties. The preliminary assessment concluded the insurer was responsible for the property’s resultant water damage, but not for the leaks in the property’s roof and balcony. The preliminary assessment was accepted by the complainant but rejected by the insurer. In rejecting the preliminary assessment, the insurer says the property’s garage ceiling damage and the bedroom ’s secondary ceiling damage was not caused by a single storm event. No new material was provided. Insurer is assumed to have declined part of the bedroom ceiling damage In its 6 December 2019 notice of response, the insurer said it had accepted liability for the relevant bedroom’s resultant water damage without indicating any exceptions. However, its post-preliminary assessment submission indicates it disputes liability for the be droom’s secondary ceiling damage. Accordingly, I assume the bedroom’s secondary ceiling damage is also in issue. Complainant must prove claim is covered and insurer must prove it is excluded The complainant must establish on the balance of probabilities he suffered a loss caused by an event to which the policy responds. This is known as a prima facie or valid claim. The complainant holds what is commonly known as an insured events type of policy. This means he must show his property was damaged by either:  storm, or  water escaping from an item listed under the ‘Escape of liquid’ section of the policy. Once so established, the onus shifts to the insurer to prove on the balance of probabilities that an exclusion applies if it seeks to deny or limit its liability for the loss. Accordingly, the insurer must establish the damage was caused by:  a construction defect and damage arising from this is excluded  a failure to maintain the property and damage arising from this is excluded. The relevant policy extracts are set out in supporting section 3.1 of this determination. Determination | Case number: 675618 Page 4 of 11 Expert information says property damage was caused by three different leaks The property was inspected by the complainant’s plumber (MP) and the insurer’s builder (PP) on 12 August 2019 and 2 September 2019 respectively. MP’s report was somewhat inconclusive , saying:  there were ‘several issues’ that could have caused the leak into the property, such as, the size of the box gutter, the way the roof was laid, the flashings around the balcony, the sealant on the balcony corners and walls  it cannot determine the cause of the water damage to the property’s ceiling without cutting it open to trace where the water came from. PP ’s report was more detailed about the matter. PP identified water damage at two separate locations on the downstairs bedroom ceiling, and on the garage and kitchen ceiling. As to what caused these damages, PP believes:  the separate water damage to the bedroom ceiling were due to two separate causes, namely: > rainwater being forced under flashings and through sheet joins during a heavy downpour, because of what appears to be an improperly positioned downpipe spreader and inadequate flashing > the balcony being unsealed, in that there is a gap (between the balcony tiles and a folded flashing) which allowed water to seep through into the ceiling space.  the garage ceiling damage was due to water seeping through the same unsealed area of the balcony that contributed to one part of the bedroom ceiling damage  the kitchen ceiling damage was due to water escaping a box gutter above it, which was leaking due to a deteriorated silicone seal. In a later email, PP also clarified:  the gap between the balcony tiles and flashing at the balcony were never sealed from the time the property was constructed  the complainant was unlikely aware of this. PP’s findings were also supported by photos and the complainant has not produced any expert information to persuasively challenge PP’s findings. Accordingly, I accept PP’s findings as to the cause of water leaks and the resultant damage to the complainant’s property , save for one aspect which I will outline later. Determination | Case number: 675618 Page 5 of 11 Rainwater is likely to seep through balcony gap during heavy and intense rain The insurer has accepted liability for the bedroom ceiling damage that was caused by an improperly positioned downpipe spreader, so this determination will address the bedroom ceiling’s secondary damage and the garage ceiling damage. On review of the exchanged information, I am satisfied on the balance of probabilities these damages likely arose from the August 2019 storm. PP’s photo of the unsealed balcony gap shows it is located at the top of a channel running along the balcony’s side. PP called the channel a ‘box gutter’, and it appears to function as a drain to channel rainwater from the balcony floor. The balcony tiles also appear to overhang the flashing it sits on, which suggests rainwater from the balcony would naturally fall into the gutter first. Considering the depth of the gutter, rainwater is only likely to seep through the gap between the balcony tiles and the flashing beneath if the channel is full. This is likely to occur if the intensity of rainfall is greater than the rate the channel can drain rainwater away. That is, if rainwater is falling into the gutter at a greater rate than the rate the gutter is able to drain the water away, water would simply build up in the gutter until a point it starts to seep through the unsealed gap at the top. In short, rainwater is only likely to escape through the unsealed balcony gap during heavy and intense rain. Garage and bedroom secondary damage likely caused by August 2019 storm That the August 2019 storm was likely significant seems supported by the fact the ceiling damage in the garage, bedroom and kitchen happened at the same time. Further, while there may be evidence of prior water entry, there appears to be no reports or incidences of prior internal water damage to the property over its three-year life. The policy schedule says the property was apparently constructed around 2016. PP’s report also seems vague about whether previous incidences of rainwater entry had contributed to the garage and bedroom ceiling damage . The earlier part of its report says there were prior incidences of water entry without saying the garage ceiling and the bedroom ceiling secondary damage was contributed by previous water entry. This part of PP’s report was cited in the insurer’s 23 April 2020 submission. In a later part of its report, PP then suggests ‘the damage sustained to the garage… have occurred on multiple occasions’ . Ultimately, photos supplied by PP only seem to show some staining to some internal timbers over the water damaged garage ceiling. The timbers do not appear rotted or structurally damaged. This suggests that although the property may have had prior incidences water entry, no ceiling damage occurred until the August 2019 storm. Determination | Case number: 675618 Page 6 of 11 Considering these matters, I am on the balance of probabilities satisfied the garage and bedroom ceiling water damage probably occurred during the August 2019 storm. Policy responds to garage and ceiling damage under storm section The policy covers resultant storm damage, even if it was contributed by an unknown defect. As PP confirms the complainant would not have been reasonably aware of the unsealed gap in the balcony, I am satisfied the complainant is entitled to indemnity for the garage and ceiling damage. Policy also responds under ‘Escape of liquid’ section I am also satisfied the policy would respond to the damage even if previous leaking incidences may have contributed to the relevant ceiling damage. The policy ’s ‘Escape of liquid’ section covers loss or damage caused by:  water leaking or overflowing from a ny drain or gutter  a gradual process of leaking or overflowing from a drain or gutter over a period which the complainant could not have been reasonably aware of. As previously explained, the unsealed gap in the balcony is located at the top of a gutter that is meant to drain water away. This means water seeping through the gap is also water leaking or overflowing from the relevant gutter or drain. This attracts cover under ‘Escape of liquid’, since the damage would have been caused by a gradual leak and the complainant was not reasonably aware of the gap. ‘Escape of liquid’ section also covers kitchen ceiling damage The policy ’s ‘Escape of liquid’ section also responds to the kitchen ceiling damage for the same reason. PP’s unchallenged finding is that the kitchen ceiling damage was unlikely caused by a single storm event, so the storm section of the policy would not respond . However, the ceiling was in any event damaged by water escaping a box gutter above it because of a deteriorated silicone seal. There is also nothing to suggest the complainant was aware or should have been reasonably aware of the defect, until PP reported it after the August 2019 storm. Given that the property was also only about three years old, it does not appear unreasonable if the complainant did not anticipate the relevant silicone seal to have deteriorated so soon. Determination | Case number: 675618 Page 7 of 11 Exclusion for failure to maintain cannot fairly apply in the complainant’s case I am not satisfied the exclusion for a failure to maintain could fairly apply in the complainant’s situation . The complainant could not have reasonably known of the gap in the balcony or the deteriorated seal in the box gutter above the kitchen. PP confirmed the complainant was unaware of the balcony gap. The property was also only about three years old, so it is not reasonable to expect him to have known that the silicone seal in the relevant box gutter had deteriorated so soon. The complainant is also not the property’s occupier. The insurer also knows this since it issued him a landlord’s policy. This means the complainant:  only had limited access to property for inspections  would unlikely know of any issues with the property unless his tenant informs him. Finally, t he policy’s cover for resultant damage when a person is unaware of a defect essentially becomes meaningless, if the lack of maintenance exclusion were to apply to a defect a person is reasonably unaware of. For these reasons, I am satisfied the complainant is entitled to indemnity for the resultant water damage to his property’s garage, bedroom and kitchen ceiling. Policy does not cover the sources of the leaks However, I am not satisfied the complainant is entitled to indemnity for the cost of rectifying the identified leaks into his property. The available information suggests the leaks were not caused by an event the policy covers but rather, were essentially construction or premature wear and tear defects. Insurer is to reimburse cost of repairing resultant damage with interest I understand the complainant has since attended to the repairs to his property. However, he did not appear to have provided the relevant invoice or receipt for this. Accordingly, the complainant is to forward the relevant repair invoice and/or receipt to the insurer within seven days of his acceptance of the determination, if he has not already done so. Determination | Case number: 675618 Page 8 of 11 On receipt of these documents, the insurer is to:  settle the claims for the bedroom and garage ceiling damage as storm damage  settle the claim for the kitchen ceiling damage as escape of liquid damage  reimburse the complainant for the cost of repairing the resultant water damage to his property only (less applicable excesses) within seven days, together with interest at the statutory rate: > from the date he paid for the repairs > until payment is made. For the avoidance of doubt, any period taken by the complainant in excess of seven days to supply the insurer with the relevant repair invoice and/or receipt is to be excluded from interest calculations. Determination | Case number: 675618 Page 9 of 11 3 Supporting information 3.1 Relevant policy wordings What you are covered for – Insured Events … Storm We cover We do not cover Loss or damage caused by a storm … … Escape of liquid We cover We do not cover Loss or damage caused by liquid leaking, overflowing or bursting from any of the following: …  any drain, fixed pipes, roof gutters or guttering and rainwater downpipes, drainage and sewage systems …  wear and tear, or loss or damage by the escape of liquid occurring as a result of a gradual process of leaking , splashing, dripping or overflowing over a period of time when you could reasonably be expected to be aware of this condition; … What we do not cover – general exclusions You are not covered under any section of the policy for damage, loss, cost or legal liability that is caused by, arises from or involves: … Failing to take care of the building or your landlord contents your failure to:  take reasonable care of the building or unit and your landlord contents;  keep the building or unit and your landlord contents well maintained and in good condition. For the meaning of ‘well maintained and in good condition’ see ‘What do you mean by that?’ section on 63 to 67;  fix faults and defects as soon as you or your agent become aware of them. … Building claims … Dealing with defects … Determination | Case number: 675618 Page 10 of 11 If an unknown defect is the cause of the damage If an incident covered by your policy damages the building and an unknown defect was the cause or part of the cause, we will pay for the resulting damage. If the unknown defective part of the building is also damaged by the same incident, we will fix this as well. … What do we mean by that? … Event or incident means a single event, accident or occurrence which you did not intend or expect to happen. … Insured events means the insured events on pages 18 to 27. In addition, an insured event is always a single event, accident or occurrence which you did not intend or expect to happen. … Well maintained and in good condition means the building or unit and landlord contents do not have any faults or defects that might cause loss or damage to the building and landlord contents, loss or damage to property of others or injury to people. This includes but is not limited to the following:  the roof does not leak when it rains;  there are no areas of the roof that are rusted through;  there is no wood rot, termite or white ant damage to the building or unit;  there are no holes in floors, walls, ceilings or any other parts of the building or unit (e.g. external wall, cladding, internal plaster, floorboards);  there are no boarded up or broken windows;  there are no steps, gutters, flooring, walls, ceiling or any other areas of the building or unit that are loose, falling down, missing or rusted through;  all previous damage including damage caused by flood has been repaired;  the building or unit is not infested with vermin;  there are no squatters or unauthorised persons occupying the building unit. 3.2 Relevant Macquarie dictionary definitions considered Word Meaning given in Macquarie dictionary Drain - noun 7 . that by which anything is drained, as a pipe or conduit. Determination | Case number: 675618 Page 11 of 11 Word Meaning given in Macquarie dictionary Gutter noun 1. a channel at the side (or in the middle) of a road or street, for leading off surface water 2. any channel, trough, or the like for carrying off fluid 3. Also, gully; Chiefly Victoria and Tasmania , spout. a channel at the eaves or on the roof of a building for carrying off rainwater, usually to the guttering. 4. a furrow or channel made by running water.

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.