Home / Suncorp Group / Determination 674632

Determination 674632

Claim denied for wall and ceiling cracking after water damage settlement

FirmSuncorp Group
Decided2020-05-25
ProductGeneral Insurance · Home building and contents
OutcomeFor the firm
Amount awarded—
Non-financial loss—
Amount claimed$39,720
SourceAFCA PDF

Summary

After a burst pipe claim was settled, the complainants sought a further $39,719.74 for plaster cracking they attributed to force-drying. AFCA found on expert evidence that the cracking was caused by ground movement, which the policy excludes, so the insurer may deny it.

The policy expressly excludes ground movement, and the engineer's evidence of long-term foundation settlement was preferred over the builder's drying theory.

Issues

Subjects and remedies

home or building damageno remedy

Related

All Suncorp Group determinations · Find similar determinations

Text of the determination

Determination Case number 674632 Financial firm AAI Limited Determination | Case number: 674632 Page 2 of 4 Case number: 674632 15 May 2020 1 Determination overview 1.1 Complaint The complainants hold a home and contents policy with the financial firm (insurer). They lodged a claim on 29 May 2019 for water damage to their home due to a burst water pipe in the kitchen ceiling. The insurer accepted and settled the claim ($47,590.65 for the building damage and $24,723.54 for the contents damage). On 19 July 2019 the complainants contacted the insurer again and advised cracks were appearing in the ceiling and wall plaster after the drying was complete. They believe the drying process may have caused the cracks. The insurer assessed and subsequently denied cover for the cracking, saying it was due to foundation movement occurring over time and the policy excludes ground movement. The complainants disagree and say the cracks only appeared after the property was force-dried. They seek a further payment of $39,719.74 plus allowances as outlined by their builder. The case manager provided the parties with a recommendation on the issues in dispute. The recommendation was in favour of the insurer. A copy of the recommendation is attached to this determination. 1.2 Issues and key findings Were the findings of the recommendation correct? The findings contained in the recommendation were correct and are adopted in this determination. Further submissions provided after the recommendation have been considered. I agree with the case analyst ‟s reasons for the recommendation and the recommended outcome. Is the insurer entitled to deny the cracking claim? The insurer is entitled to deny the claim for the cracking damage, because the evidence does not show, on balance, the proximate cause was the insured water leak and/or associated drying work. Instead, it is more likely than not the result of ground movement over time, which is a policy exclusion. 1.3 Determination This determination is in favour of the insurer. It is not required to take any further action. Determination | Case number: 674632 Page 3 of 4 2 Reasons for determination 2.1 Were the findings in the recommendation correct? I have decided this case based on what I consider is fair in the circumstances, having regard to the relevant law, good industry practice, codes of practice and previous AFCA decisions. I have taken into account all the material submitted by the parties, both before and after the recommendation. I am satisfied that the documentation I have relied on has been provided to both parties. I am satisfied that the case analyst ‟s recommendation contains an accurate summary of the complaint, the issues to be determined, any applicable paragraphs of the Rules and any relevant law. 2.2 Is the insurer entitled to deny the cracking claim? The policy provides cover for escape of liquids subject to exclusions There is no dispute between the parties an escape of liquid incident occurred. The insurer partially accepted and settled the claim. The issue in dispute is the cause of the hairline cracking of the plaster and cornices near the ceiling, above door frames, and at intersections of the walls. The complainants say the damage is due to the escape of liquid causing swelling of the timber base plates, which shrank during force-drying, leading to the cracks forming. The insurer says the damage is due to ground movement and settling of the foundation materials which damaged the plaster over time. The expert evidence does not support complainants’ position The complainants ‟ builder RR reported the damage was caused by drying the property after the water damage, given the rapid reduction of moisture inside the property which resulted in movement and shrinkage of plaster connections and joints throughout the ceiling plane. In other words, RR attributes the cracking back to the steps taken by the insurer to deal with the original insured event. However, the insurer ‟s builder AB says the damage is consistent with standard house movement over time, and not water running over the floor during the burst pipe event. AB does not address the possible effect of the drying process. The insurer ‟s engineer JH also concluded the cause of the damage (hairline/minor cracks) was long-term ground movement, as the property has settled rather than heaved (which means a sudden water inundation of the soil could not have caused the damage). JH presented evidence which showed the foundations of the home had moved significantly, floor levels vary throughout the property, cracking was remote from the Determination | Case number: 674632 Page 4 of 4 leak location, there was evidence of previous repair, and there was no obvious structural damage attributable to a single insurable event. The insurer is entitled to deny the claim The complainants‟ position is that the cause of the cracking was the swelling and then drying of the timber base plates, however that is not supported by the available evidence. JH also responded specifically to the information provided by the complainants and RR with regard to the possible effect of the drying process , and very clearly stated the cracking could not have been caused by rapid drying. JH explained the cracking was typical of that to be expected between different materials; there are no bottom plates under block walls; and there was no damage to the wall linings, floor finisher or skirtings. The complainants did not refute JH‟s explanation. I am not satisfied, on the available evidence, the cracking was a result of the insured water leak or the drying process conducted to deal with it. Instead, I consider it more likely than not to be caused by ground movement over time. The policy specifically excludes cover for any ground movement. The insurer is entitled to deny the claim for cracking damage. Recommendation Case number 674632 Financial firm AAI Limited Recommendation | Case number: 674632 Page 1 of 10 Case number: 674632 17 April 2020 3 Overview 3.1 Complaint The complainants hold a home and contents policy with the financial firm (insurer). The complainants lodged a claim on 29 May 2019 for water damage sustained to their home due a burst water pipe in the kitchen ceiling. The insurer accepted the water damage and settled the complainants $47,590.65 for the building damage and $24,723.54 for the contents damage. On 19 July 2019 the complainants contacted the insurer again and advised cracks were appearing in the ceiling and wall plaster after the drying was complete. The complainants also outlined their view the drying may have caused the cracks. The insurer assessed the cracking and subsequently denied cover for the cracking saying the damage is due to foundation movement which has occurred over time. The insurer says the policy excludes ground movement. The complainants disagree and say the cracks only appeared after the property was force dried. The complainants seek a further settlement payment of $39,719.74 plus allowances as outlined by their builder. 3.2 Issues and key findings Is the insurer entitled to deny the cracking claim? Yes. The insurer is entitled to partially deny the claim, this is because:  the policy provides cover for damage caused by escape of liquids  the insurer‟s liability is based on the pr oximate cause of the damage  the expert information disagrees on the proximate cause  the complainants have not established a valid claim for the damage  the complainants‟ arguments have not advanced their position 3.3 Recommendation This recommendation is in favour of the insurer. The insurer is entitled to partially deny the claim. The insurer is not required to take any further action. Recommendation | Case number: 674632 Page 2 of 10 4 Reasons for recommendation 4.1 Is the insurer entitled to deny the cracking claim? The policy provides cover for escape of liquids subject to exclusions The complainants holds the onus to show, on balance, she suffered a loss caused by a risk insured against under the policy. This is known as establishing a valid (Prima facie) claim. Once established the onus passes to the insurer to show, on balance:  the damage is excluded by the policy terms and conditions  it is otherwise entitled to deny the claim. The details of the policy can be found in the product disclosure statement and the policy schedule which were provided by the insurer. The policy provides cover for damage caused by the insured events listed in the policy (including escape of liquid), subject to the exclusions outlined in the policy. There is no dispute between the parties an escape of liquid incident occurred. The insurer partially accepted and settled the claim. Parties are in dispute about the cause of the hairline cracking of the plaster and cornices near the ceiling, above door frames, or at intersections of the walls. Each party holds a different view on the proximate cause. The complainants say the damage is due to the escape of liquid causing swelling of the timber base plates, which shrank during force drying causing the cracks to form. The insurer says the damage is due to ground movement and settling of the foundation materials which damaged the plaster over time. The expert information disagrees on the proximate cause Three expert views were given on the proximate cause of the damage. The complainants provided a report from their builder (RR). In his report RR says the damage was caused by drying the property after the water damage because:  it created a rapid reduction of moisture in the interior of the property whilst the external conditions were still very humid  this has resulted in movement and shrinkage of plaster connections and joints throughout the ceiling plane. Recommendation | Case number: 674632 Page 3 of 10 This relates the damage to the escape of water as it set the chain of events in motion which lead to the drying and therefore the damage. The insurer supplied a report from its builder (AB) which says the damage is consistent with standard house movement and not water running over the floor during the burst pipe event. It supports this view by saying:  some of the cracked cornice is directly below expansion joints in the ceilings, which is normal, as the ceiling moves around the expansion joints it cracks the cornice  there are cracks in open plan ceilings that don‟t have the required amount of expansion joints.  some plaster cornice has separated from block walls due to failure of cornice cement over time. This relates the damage to normal movement of the property as it ages rather than water damage from a burst pipe event. Given the nature of damage, the insurer engaged an engineer (JH) to assess causation of the cracking damage. The report outlines the dwelling experienced cracking ranging from hairline to minor cracks. JH says the cause of the damage is ground movement because:  differential movement of the foundation throughout the dwelling was the primary cause of the differential cracking that had occurred  the foundations of the dwelling had moved with differences in levels of up to 20mm recorded  locations of cracking are remote from the leak location  some of the cracks displayed evidence of previous repair indicating historical movement  the largest area of saturation will be around the area of the leak and hence if significant heave has occurred, the majority of the damage would be localised in close vicinity of the pipe leak  there was no readily visible evidence of structural damage attributed to a single insurable event. Having reviewed the level survey, I note the entire property has experience different degrees of movement. This is showing their view the mechanism is caused by ground movement acting on the foundation material, which in turn has caused variations of the floor height throughout the property. JH considered whether the subject event has contributed to the claimed damage but concludes it could not be as the property has settled instead of heaved. This means a sudden water inundation of the soil could not cause the damage. Recommendation | Case number: 674632 Page 4 of 10 The complainants’ arguments have not advanced their position While I acknowledge t he complainants‟ argument the cause was the swelling and then drying of the timber base plates, none of the expert views support this as the mechanism of the damage. I also acknowledge the complainants‟ argument they first noticed the damage after the escape of water event. Unfortunately, this does not show the proximate cause was the escape of liquids in view of the other evidence. Lastly, I acknowledge the complainants‟ argument the property is kept at a constant irrigation level, is well maintained, and the engineer has said the movement has not exceeded the building standard. While these are all valid points to make, there is clear evidence showing there are variations in floor levelling throughout the property. No other explanation for how this is occurring has been presented, nor why the policy covers it. The complainants also refer to:  Queensland Building and Construction Commission (QBCC) publication „A Contractor‟s Guide to Rebuilding after a Flood - March 2015‟.  The local council‟s Mapping Service‟  Timber Queensland Technical Guide - Guide to Assessment and Repair of Flood Damaged Timber and Timber Framed Houses (Revised Feb 2015). However, we have not received a copy of these documents, nor any details on what parts are relevant to the complaint. The references also do not appear in the RR report. I note these publications refer to flood events rather than an escape of liquid event. The insurer is entitled to deny the claim After carefully considering all the material, the insurer‟s position on t he proximate cause is preferred. This is because the insurer‟s explanation of the damage is clearer and more consistent than the complainants‟ expert. The complainants rely on the report from RR, which clearly outlines their opinion on the cause. The explanation is plausible, but the report gives no evidence to support the opinion other than a hypothesis and the photos of the resulting damage. The insurer relies primarily on the findings in the JH report. This report is detailed and clearly establishes there is floor height differences which fluctuate throughout the property of up to 20mm. Recommendation | Case number: 674632 Page 5 of 10 The report clearly outlines the mechanism of the damage and why it is not related to the escape of water event. Specifically, the report points out the damage is caused by settling of the foundation, not heaving, which cannot be attributed to the burst pipe. The report also clearly notes there are signs of previous repair and cracking in sections of the house which are remote from where the leak occurred. While these are not definitive on their own, when added to the other information they do suggest there is long term damage occurring which is not attributable to the escape of liquid event. In a subsequent letter, JH also supplied a response to the information provided by the complainants and RR. They did not accept the drying was the cause because the:  property inspection records and photos show moisture and water stains in the ceiling lining at the inspection time which confirms that there was no rapid drying.  cracks location above block walls contradict the Insured theory of the bottom plates swelling and shrinkage as block walls do not have any bottom plates  typical vertical cracks between (different materials) timber trims, block work and plasterboard ceiling and wall lining in the absence of a flexible sealant or gap filler joints.  absence of damage to the wall linings, floor finisher or skirtings. I find JHs‟ findings logical, persuasive, and conclusive. JH‟s view is supported by the variation in the floor levels. I note neither the complainants nor RR refuted JHs‟ comments regarding the mechanism of damage or the analysis of the evidence. I accept the proximate cause is ground movement for the reasons outlined above. I have carefully considered the insurer‟s polic y wording. The policy clearly and unequivocally excludes any ground movement. I am satisfied the insurer is entitled to deny the cracking claim. Recommendation | Case number: 674632 Page 6 of 10 5 Supporting information 5.1 AFCA Approach There has been a full exchange of the relevant material between the parties and each party has had the opportunity to address the issues raised. All material provided has been read and considered. For this recommendation, commentary is restricted to only materials considered relevant to the outcome 5.2 Summary of Reports Record Key points Complainants’ expert (RR) Builder‟s r eport 21 Feb 2020 Following the event, the home was force dried by use of evaporative fans provided by the insurer. This force drying has contribut ed to the rapid reduction of moisture in the interior of the home whilst the external conditions were still very humid. The rapid reduction in moisture content/humidity inside the home has resulted in movement and shrinkage of plaster connections and joints throughout the ceiling plane. This has caused cracking in areas throughout the home resultant from the forced drying of the home following the event. A visual inspection of the areas of c oncern was conducted by RR on Thursday, 13 February 2020. It was noted that there are areas within the home where significan t movement has occurred in cornices with cracks in mitred joints and connection to the masonry wall in the hallway. Timber mouldings also show significant movement. Conclusion : It is my opinion the forc ed (mechanical) drying of the home following the event as described in this report has produced the above resultant damage to the owner‟s property. The rapid decrease in the humidity levels in the home brought about by the forced (mechanical) drying has resulted in the plaster jointing compounds being unable to maintain their integrity as the moisture levels below the ceiling line dec reased to levels well below that which would have been occurring externally and in the ceiling cavity thus causing excess shrinkage and movement to occur in and around the ceiling linings. Insurer’s expert (AB) Builder‟s report 27 Jul 2019 In my opinion the cracking separation is consistent with standard house movement and would not be caused by water running over the floor during the burst pipe event. Some of the cracked cornice is directly below expansion joints in the ceilings, which is n ormal, as the ceiling moves around the ex pansion joints it cracks the cornice. There are also cracks in open plan ceilings that don‟t have Recommendation | Case number: 674632 Page 7 of 10 Record Key points the required amount of expansion joints, some plaster cornice has separated from block walls due to failure of cornic e cement over time. Insurer’s expert (JH) Engineer‟s report 16 Aug 2019 Possible foundation movement Cracking can be caused by differential foundation movement. To assess if the foundations had moved, a hydraulic level survey was undertaken throughout the interior floor of the dwelling. While it is recognised that all buildings move, it is the extent of the movement that determines if there is a fundamental structural problem. Results of electronic level survey (mm ) The results of the survey found the foun dations of the dwelling had moved with differences in levels of up to 20mm recorded. This was considered significant but not excessive. It is also expected for a dwelling constructed on this type of soil. The level variations were within the acceptable mov ement tolerances of the Australian Standard AS2870 performance provisions (excerpt attached). As can be seen, differential movement of the foundation throughout the dwelling was the primary cause of the differential cracking that had occurred. Locations of cracking are remote from the leak location, so it is not considered that moisture from the pipe leak has entered the plasterboard and affected cracking throughout the remainder of the dwelling. Cause of Settlement Structures can, and often do, move. This movement can be up, down, lateral or rotational. The fundamental cause of movement in buildings and structures can usually be related to one or more problems in the foundation soil. The types of soils usually present under the topsoil in land zoned for res idential building can be split into two approximate groups - granular soils and clay soils. Review of Australian Soil Resource Information System classi fies 40 - 60% clay content in the subsoils of the area Clay soils are often called reactive soils. A soil is said to be reactive or expansive when it undergoes appreciable volume change upon changes in moisture content. The reactivity of a soil depends on the size of the clay particle, the mineral composition and the proportion of clay in the soil. The movemen t that might occur on a site depends not only on the reactivity of the clay but also on the depth and distribution of the clay in the soil profile and on changes in moisture content. Moisture changes usually occur slowly in clays and produce swelling upon Recommendation | Case number: 674632 Page 8 of 10 Record Key points wetting and shrinkage upon drying. The evidence from the site inspection indic ates that the cause of the cracking and movement to the dwelling was ground movement. This ground movement had occurred as a res ult of long - t erm seasonal swelling/shrinkage in th e founding soils due to the reactive clay subsoils and not as a result of a pipe leak event. Recommendations for foundation maintenance are provided in the attached CSIRO document on Foundation Maintenanc e in Reactive Soil sites. This may assist the owner in minimising further cracking and damage to the dwelling. Is the damage caused by the pipe leak? It is not unreasonable to expect that a certain level of heave would be experienced at the location if the reactive clay soil experienced a high saturation ev ent (e.g. from a pipe leak). The CSIRO Foundation Maintenance and Footing Performance: A Homeowner‟s Guide states “the swelling of soil creates an upward force on the footings of the building” after exposure to water and moisture from a pipe leak incident. The largest area of saturation will be around the area of the leak and hence if significant heave has occurred, the majority of the damage would be localis ed in close vicinity of the pipe leak. Cracking in the brick walls closest to the pipe leak would sh ow signs of any possible heaving or damage. The site inspection found cracking damage scattered throughout the house. The evidence indicates that the soil did not result in any observed evidence of heave. The building had settled, not heaved. The evidence was not consistent that the water leak had resulted in heave of the natural soils. CONCLUSION The dwelling experienced cracking ranging from hairline to minor cracks. The insured advised a pipe leak occurred in the roof of the rear LHS of the dwelling at t he kitchen area. The Insured suspected the cracking sustained throughout the house may have been caused by the pipe leak. The available evidence indicates that the damage was caused by a long - term and ongoing issue attributed to significant foundation move ment. Some of the cracks displayed evidence of previous repair indicating historic al movement. The movement had caused the hairline to minor cracking damage throughout the dwelling. Recommendation | Case number: 674632 Page 9 of 10 Record Key points There was no readily visible evidence of structural damage attributed to a single insurable event. Insurer’s expert (JH) Supplement ary report 2 Mar 2020 RESPONSE TO REQUEST FOR ADDITIONAL INFORMATI ON The email dated 21st February 2020 from Customer Relations had requested: “to confirm whether the crack ing identified in the above report could have been caused from rapid drying as suggested above. Or alternatively, whether to the best of your k nowledge this has been seen before or the possibility this could occur in the area’s the crack ing has occurred. ” 1. Whether the cracking i dentified in the above report could have been caused from rapid drying as sugge sted above? No, the cracking identified in the report could not have been caused from rapid drying as outline in the Insured complaint, the property inspection records and phot os show many evidences of: - Moisture and water stains in the ceiling lining at the inspection time confirms that there was no rapid drying. - Cracks location above block walls contradict the Insured theory of the bottom plates swelling and shrinkage as bloc k walls do not have any bottom plates. - Typical vertical cracks between (different materials) timber trims, block work and plasterboard ceiling and wall lining in the absence of a flexible sealant or gap filler joints. - No damage on the wall linings, floor finisher or skirtings Referring to Queensland Building and Construction Commission (QBCC) “ A CONTRACTOR‟S GUIDE TO REBUILDING AFTER A FLOOD” March 2015 – Page 4, rapid drying is recommended by QBCC for such events. 5.3 Additional information relied on  The parties‟ respective submissions.  The relevant terms of the policy and certificate of insurance Recommendation | Case number: 674632 Page 10 of 10

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.