Home / Suncorp Group / Determination 674632
Determination 674632
Claim denied for wall and ceiling cracking after water damage settlement
Summary
After a burst pipe claim was settled, the complainants sought a further $39,719.74 for plaster cracking they attributed to force-drying. AFCA found on expert evidence that the cracking was caused by ground movement, which the policy excludes, so the insurer may deny it.
The policy expressly excludes ground movement, and the engineer's evidence of long-term foundation settlement was preferred over the builder's drying theory.
Issues
- Claim denial primary · not upheld“The insurer is entitled to deny the claim for cracking damage, because the evidence does not show the proximate cause was the insured water leak and/or associated drying work.”
Subjects and remedies
home or building damageno remedy
Related
All Suncorp Group determinations · Find similar determinations
Text of the determination
Determination
Case number 674632
Financial firm AAI Limited
Determination | Case number: 674632 Page 2 of 4
Case number: 674632 15 May 2020
1 Determination overview
1.1 Complaint
The complainants hold a home and contents policy with the financial firm (insurer).
They lodged a claim on 29 May 2019 for water damage to their home due to a burst
water pipe in the kitchen ceiling. The insurer accepted and settled the claim
($47,590.65 for the building damage and $24,723.54 for the contents damage).
On 19 July 2019 the complainants contacted the insurer again and advised cracks
were appearing in the ceiling and wall plaster after the drying was complete. They
believe the drying process may have caused the cracks.
The insurer assessed and subsequently denied cover for the cracking, saying it was
due to foundation movement occurring over time and the policy excludes ground
movement.
The complainants disagree and say the cracks only appeared after the property was
force-dried. They seek a further payment of $39,719.74 plus allowances as outlined
by their builder.
The case manager provided the parties with a recommendation on the issues in
dispute. The recommendation was in favour of the insurer. A copy of the
recommendation is attached to this determination.
1.2 Issues and key findings
Were the findings of the recommendation correct?
The findings contained in the recommendation were correct and are adopted in this
determination. Further submissions provided after the recommendation have been
considered. I agree with the case analyst ‟s reasons for the recommendation and the
recommended outcome.
Is the insurer entitled to deny the cracking claim?
The insurer is entitled to deny the claim for the cracking damage, because the
evidence does not show, on balance, the proximate cause was the insured water leak
and/or associated drying work. Instead, it is more likely than not the result of ground
movement over time, which is a policy exclusion.
1.3 Determination
This determination is in favour of the insurer. It is not required to take any further
action.
Determination | Case number: 674632 Page 3 of 4
2 Reasons for determination
2.1 Were the findings in the recommendation correct?
I have decided this case based on what I consider is fair in the circumstances, having
regard to the relevant law, good industry practice, codes of practice and previous
AFCA decisions. I have taken into account all the material submitted by the parties,
both before and after the recommendation. I am satisfied that the documentation I
have relied on has been provided to both parties.
I am satisfied that the case analyst ‟s recommendation contains an accurate summary
of the complaint, the issues to be determined, any applicable paragraphs of the Rules
and any relevant law.
2.2 Is the insurer entitled to deny the cracking claim?
The policy provides cover for escape of liquids subject to exclusions
There is no dispute between the parties an escape of liquid incident occurred. The
insurer partially accepted and settled the claim.
The issue in dispute is the cause of the hairline cracking of the plaster and cornices
near the ceiling, above door frames, and at intersections of the walls. The
complainants say the damage is due to the escape of liquid causing swelling of the
timber base plates, which shrank during force-drying, leading to the cracks forming.
The insurer says the damage is due to ground movement and settling of the
foundation materials which damaged the plaster over time.
The expert evidence does not support complainants’ position
The complainants ‟ builder RR reported the damage was caused by drying the
property after the water damage, given the rapid reduction of moisture inside the
property which resulted in movement and shrinkage of plaster connections and joints
throughout the ceiling plane. In other words, RR attributes the cracking back to the
steps taken by the insurer to deal with the original insured event.
However, the insurer ‟s builder AB says the damage is consistent with standard house
movement over time, and not water running over the floor during the burst pipe event.
AB does not address the possible effect of the drying process.
The insurer ‟s engineer JH also concluded the cause of the damage (hairline/minor
cracks) was long-term ground movement, as the property has settled rather than
heaved (which means a sudden water inundation of the soil could not have caused
the damage).
JH presented evidence which showed the foundations of the home had moved
significantly, floor levels vary throughout the property, cracking was remote from the
Determination | Case number: 674632 Page 4 of 4
leak location, there was evidence of previous repair, and there was no obvious
structural damage attributable to a single insurable event.
The insurer is entitled to deny the claim
The complainants‟ position is that the cause of the cracking was the swelling and then
drying of the timber base plates, however that is not supported by the available
evidence.
JH also responded specifically to the information provided by the complainants and
RR with regard to the possible effect of the drying process , and very clearly stated the
cracking could not have been caused by rapid drying. JH explained the cracking was
typical of that to be expected between different materials; there are no bottom plates
under block walls; and there was no damage to the wall linings, floor finisher or
skirtings.
The complainants did not refute JH‟s explanation.
I am not satisfied, on the available evidence, the cracking was a result of the insured
water leak or the drying process conducted to deal with it.
Instead, I consider it more likely than not to be caused by ground movement over
time. The policy specifically excludes cover for any ground movement.
The insurer is entitled to deny the claim for cracking damage.
Recommendation
Case number 674632
Financial firm AAI Limited
Recommendation | Case number: 674632 Page 1 of 10
Case number: 674632 17 April 2020
3 Overview
3.1 Complaint
The complainants hold a home and contents policy with the financial firm (insurer).
The complainants lodged a claim on 29 May 2019 for water damage sustained to their
home due a burst water pipe in the kitchen ceiling.
The insurer accepted the water damage and settled the complainants $47,590.65 for
the building damage and $24,723.54 for the contents damage.
On 19 July 2019 the complainants contacted the insurer again and advised cracks
were appearing in the ceiling and wall plaster after the drying was complete. The
complainants also outlined their view the drying may have caused the cracks.
The insurer assessed the cracking and subsequently denied cover for the cracking
saying the damage is due to foundation movement which has occurred over time. The
insurer says the policy excludes ground movement.
The complainants disagree and say the cracks only appeared after the property was
force dried. The complainants seek a further settlement payment of $39,719.74 plus
allowances as outlined by their builder.
3.2 Issues and key findings
Is the insurer entitled to deny the cracking claim?
Yes. The insurer is entitled to partially deny the claim, this is because:
the policy provides cover for damage caused by escape of liquids
the insurer‟s liability is based on the pr oximate cause of the damage
the expert information disagrees on the proximate cause
the complainants have not established a valid claim for the damage
the complainants‟ arguments have not advanced their position
3.3 Recommendation
This recommendation is in favour of the insurer.
The insurer is entitled to partially deny the claim.
The insurer is not required to take any further action.
Recommendation | Case number: 674632 Page 2 of 10
4 Reasons for recommendation
4.1 Is the insurer entitled to deny the cracking claim?
The policy provides cover for escape of liquids subject to exclusions
The complainants holds the onus to show, on balance, she suffered a loss caused by
a risk insured against under the policy. This is known as establishing a valid (Prima
facie) claim.
Once established the onus passes to the insurer to show, on balance:
the damage is excluded by the policy terms and conditions
it is otherwise entitled to deny the claim.
The details of the policy can be found in the product disclosure statement and the
policy schedule which were provided by the insurer.
The policy provides cover for damage caused by the insured events listed in the
policy (including escape of liquid), subject to the exclusions outlined in the policy.
There is no dispute between the parties an escape of liquid incident occurred. The
insurer partially accepted and settled the claim.
Parties are in dispute about the cause of the hairline cracking of the plaster and
cornices near the ceiling, above door frames, or at intersections of the walls. Each
party holds a different view on the proximate cause.
The complainants say the damage is due to the escape of liquid causing swelling of
the timber base plates, which shrank during force drying causing the cracks to form.
The insurer says the damage is due to ground movement and settling of the
foundation materials which damaged the plaster over time.
The expert information disagrees on the proximate cause
Three expert views were given on the proximate cause of the damage.
The complainants provided a report from their builder (RR). In his report RR says the
damage was caused by drying the property after the water damage because:
it created a rapid reduction of moisture in the interior of the property whilst the
external conditions were still very humid
this has resulted in movement and shrinkage of plaster connections and joints
throughout the ceiling plane.
Recommendation | Case number: 674632 Page 3 of 10
This relates the damage to the escape of water as it set the chain of events in motion
which lead to the drying and therefore the damage.
The insurer supplied a report from its builder (AB) which says the damage is
consistent with standard house movement and not water running over the floor during
the burst pipe event. It supports this view by saying:
some of the cracked cornice is directly below expansion joints in the ceilings, which
is normal, as the ceiling moves around the expansion joints it cracks the cornice
there are cracks in open plan ceilings that don‟t have the required amount of
expansion joints.
some plaster cornice has separated from block walls due to failure of cornice
cement over time.
This relates the damage to normal movement of the property as it ages rather than
water damage from a burst pipe event.
Given the nature of damage, the insurer engaged an engineer (JH) to assess
causation of the cracking damage. The report outlines the dwelling experienced
cracking ranging from hairline to minor cracks. JH says the cause of the damage is
ground movement because:
differential movement of the foundation throughout the dwelling was the primary
cause of the differential cracking that had occurred
the foundations of the dwelling had moved with differences in levels of up to 20mm
recorded
locations of cracking are remote from the leak location
some of the cracks displayed evidence of previous repair indicating historical
movement
the largest area of saturation will be around the area of the leak and hence if
significant heave has occurred, the majority of the damage would be localised in
close vicinity of the pipe leak
there was no readily visible evidence of structural damage attributed to a single
insurable event.
Having reviewed the level survey, I note the entire property has experience different
degrees of movement. This is showing their view the mechanism is caused by ground
movement acting on the foundation material, which in turn has caused variations of
the floor height throughout the property.
JH considered whether the subject event has contributed to the claimed damage but
concludes it could not be as the property has settled instead of heaved. This means a
sudden water inundation of the soil could not cause the damage.
Recommendation | Case number: 674632 Page 4 of 10
The complainants’ arguments have not advanced their position
While I acknowledge t he complainants‟ argument the cause was the swelling and
then drying of the timber base plates, none of the expert views support this as the
mechanism of the damage.
I also acknowledge the complainants‟ argument they first noticed the damage after
the escape of water event. Unfortunately, this does not show the proximate cause
was the escape of liquids in view of the other evidence.
Lastly, I acknowledge the complainants‟ argument the property is kept at a constant
irrigation level, is well maintained, and the engineer has said the movement has not
exceeded the building standard.
While these are all valid points to make, there is clear evidence showing there are
variations in floor levelling throughout the property. No other explanation for how this
is occurring has been presented, nor why the policy covers it.
The complainants also refer to:
Queensland Building and Construction Commission (QBCC) publication „A
Contractor‟s Guide to Rebuilding after a Flood - March 2015‟.
The local council‟s Mapping Service‟
Timber Queensland Technical Guide - Guide to Assessment and Repair of Flood
Damaged Timber and Timber Framed Houses (Revised Feb 2015).
However, we have not received a copy of these documents, nor any details on what
parts are relevant to the complaint. The references also do not appear in the RR
report. I note these publications refer to flood events rather than an escape of liquid
event.
The insurer is entitled to deny the claim
After carefully considering all the material, the insurer‟s position on t he proximate
cause is preferred. This is because the insurer‟s explanation of the damage is clearer
and more consistent than the complainants‟ expert.
The complainants rely on the report from RR, which clearly outlines their opinion on
the cause. The explanation is plausible, but the report gives no evidence to support
the opinion other than a hypothesis and the photos of the resulting damage.
The insurer relies primarily on the findings in the JH report. This report is detailed and
clearly establishes there is floor height differences which fluctuate throughout the
property of up to 20mm.
Recommendation | Case number: 674632 Page 5 of 10
The report clearly outlines the mechanism of the damage and why it is not related to
the escape of water event. Specifically, the report points out the damage is caused by
settling of the foundation, not heaving, which cannot be attributed to the burst pipe.
The report also clearly notes there are signs of previous repair and cracking in
sections of the house which are remote from where the leak occurred. While these
are not definitive on their own, when added to the other information they do suggest
there is long term damage occurring which is not attributable to the escape of liquid
event.
In a subsequent letter, JH also supplied a response to the information provided by the
complainants and RR. They did not accept the drying was the cause because the:
property inspection records and photos show moisture and water stains in the
ceiling lining at the inspection time which confirms that there was no rapid drying.
cracks location above block walls contradict the Insured theory of the bottom plates
swelling and shrinkage as block walls do not have any bottom plates
typical vertical cracks between (different materials) timber trims, block work and
plasterboard ceiling and wall lining in the absence of a flexible sealant or gap filler
joints.
absence of damage to the wall linings, floor finisher or skirtings.
I find JHs‟ findings logical, persuasive, and conclusive. JH‟s view is supported by the
variation in the floor levels. I note neither the complainants nor RR refuted JHs‟
comments regarding the mechanism of damage or the analysis of the evidence.
I accept the proximate cause is ground movement for the reasons outlined above. I
have carefully considered the insurer‟s polic y wording. The policy clearly and
unequivocally excludes any ground movement. I am satisfied the insurer is entitled to
deny the cracking claim.
Recommendation | Case number: 674632 Page 6 of 10
5 Supporting information
5.1 AFCA Approach
There has been a full exchange of the relevant material between the parties and each
party has had the opportunity to address the issues raised.
All material provided has been read and considered. For this recommendation,
commentary is restricted to only materials considered relevant to the outcome
5.2 Summary of Reports
Record Key points
Complainants’ expert
(RR)
Builder‟s r eport
21 Feb 2020
Following the event, the home was force dried by use of
evaporative fans provided by the insurer. This force drying has
contribut ed to the rapid reduction of moisture in the interior of the
home whilst the external conditions were still very humid. The rapid
reduction in moisture content/humidity inside the home has
resulted in movement and shrinkage of plaster connections and
joints throughout the ceiling plane. This has caused cracking in
areas throughout the home resultant from the forced drying of the
home following the event.
A visual inspection of the areas of c oncern was conducted by RR
on Thursday, 13 February 2020. It was noted that there are areas
within the home where significan t movement has occurred in
cornices with cracks in mitred joints and connection to the masonry
wall in the hallway. Timber mouldings also show significant
movement.
Conclusion :
It is my opinion the forc ed (mechanical) drying of the home
following the event as described in this report has produced the
above resultant damage to the owner‟s property. The rapid
decrease in the humidity levels in the home brought about by the
forced (mechanical) drying has resulted in the plaster jointing
compounds being unable to maintain their integrity as the moisture
levels below the ceiling line dec reased to levels well below that
which would have been occurring externally and in the ceiling
cavity thus causing excess shrinkage and movement to occur in
and around the ceiling linings.
Insurer’s expert (AB)
Builder‟s report
27 Jul 2019
In my opinion the cracking separation is consistent with standard
house movement and would not be caused by water running over
the floor during the burst pipe event. Some of the cracked cornice
is directly below expansion joints in the ceilings, which is n ormal,
as the ceiling moves around the ex pansion joints it cracks the
cornice. There are also cracks in open plan ceilings that don‟t have
Recommendation | Case number: 674632 Page 7 of 10
Record Key points
the required amount of expansion joints, some plaster cornice has
separated from block walls due to failure of cornic e cement over
time.
Insurer’s expert (JH)
Engineer‟s report
16 Aug 2019
Possible foundation movement
Cracking can be caused by differential foundation movement. To
assess if the foundations had moved, a hydraulic level survey was
undertaken throughout the interior floor of the dwelling. While it is
recognised that all buildings move, it is the extent of the movement
that determines if there is a fundamental structural problem.
Results of electronic level survey (mm )
The results of the survey found the foun dations of the dwelling had
moved with differences in levels of up to 20mm recorded. This was
considered significant but not excessive. It is also expected for a
dwelling constructed on this type of soil. The level variations were
within the acceptable mov ement tolerances of the Australian
Standard AS2870 performance provisions (excerpt attached).
As can be seen, differential movement of the foundation throughout
the dwelling was the primary cause of the differential cracking that
had occurred. Locations of cracking are remote from the leak
location, so it is not considered that moisture from the pipe leak has
entered the plasterboard and affected cracking throughout the
remainder of the dwelling.
Cause of Settlement
Structures can, and often do, move. This movement can be up,
down, lateral or rotational. The fundamental cause of movement in
buildings and structures can usually be related to one or more
problems in the foundation soil. The types of soils usually present
under the topsoil in land zoned for res idential building can be split
into two approximate groups - granular soils and clay soils.
Review of Australian Soil Resource Information System
classi fies 40 - 60% clay content in the subsoils of the area
Clay soils are often called reactive soils. A soil is said to be reactive
or expansive when it undergoes appreciable volume change upon
changes in moisture content. The reactivity of a soil depends on
the size of the clay particle, the mineral composition and the
proportion of clay in the soil.
The movemen t that might occur on a site depends not only on the
reactivity of the clay but also on the depth and distribution of the
clay in the soil profile and on changes in moisture content. Moisture
changes usually occur slowly in clays and produce swelling upon
Recommendation | Case number: 674632 Page 8 of 10
Record Key points
wetting and shrinkage upon drying.
The evidence from the site inspection indic ates that the cause of
the cracking and movement to the dwelling was ground movement.
This ground movement had occurred as a res ult of long - t erm
seasonal swelling/shrinkage in th e founding soils due to the
reactive clay subsoils and not as a result of a pipe leak event.
Recommendations for foundation maintenance are provided in the
attached CSIRO document on Foundation Maintenanc e in Reactive
Soil sites. This may assist the owner in minimising further cracking
and damage to the dwelling.
Is the damage caused by the pipe leak?
It is not unreasonable to expect that a certain level of heave would
be experienced at the location if the reactive clay soil experienced
a high saturation ev ent (e.g. from a pipe leak). The CSIRO
Foundation Maintenance and Footing Performance: A
Homeowner‟s Guide states “the swelling of soil creates an upward
force on the footings of the building” after exposure to water and
moisture from a pipe leak incident.
The largest area of saturation will be around the area of the leak
and hence if significant heave has occurred, the majority of the
damage would be localis ed in close vicinity of the pipe leak.
Cracking in the brick walls closest to the pipe leak would sh ow
signs of any possible heaving or damage. The site inspection found
cracking damage scattered throughout the house. The evidence
indicates that the soil did not result in any observed evidence of
heave. The building had settled, not heaved.
The evidence was not consistent that the water leak had resulted in
heave of the natural soils.
CONCLUSION
The dwelling experienced cracking ranging from hairline to minor
cracks. The insured advised a pipe leak occurred in the roof of the
rear LHS of the dwelling at t he kitchen area. The Insured
suspected the cracking sustained throughout the house may have
been caused by the pipe leak.
The available evidence indicates that the damage was caused by a
long - term and ongoing issue attributed to significant foundation
move ment. Some of the cracks displayed evidence of previous
repair indicating historic al movement. The movement had caused
the hairline to minor cracking damage throughout
the dwelling.
Recommendation | Case number: 674632 Page 9 of 10
Record Key points
There was no readily visible evidence of structural damage
attributed to a single insurable event.
Insurer’s expert (JH)
Supplement ary report
2 Mar 2020
RESPONSE TO REQUEST FOR ADDITIONAL INFORMATI ON
The email dated 21st February 2020 from Customer Relations had
requested:
“to confirm whether the crack ing identified in the above report could
have been caused from rapid drying as suggested above. Or
alternatively, whether to the best of your k nowledge this has been
seen before or the possibility this could occur in the area’s the
crack ing has occurred. ”
1. Whether the cracking i dentified in the above report
could have been caused from rapid drying as
sugge sted above?
No, the cracking identified in the report could not have been
caused from rapid drying as outline in the Insured complaint, the
property inspection records and phot os show many evidences of:
- Moisture and water stains in the ceiling lining at the inspection
time confirms that there was no rapid drying.
- Cracks location above block walls contradict the Insured theory of
the bottom plates swelling and shrinkage as bloc k walls do not
have any bottom plates.
- Typical vertical cracks between (different materials) timber trims,
block work and plasterboard ceiling and wall lining in the absence
of a flexible sealant or gap filler joints.
- No damage on the wall linings, floor finisher or skirtings
Referring to Queensland Building and Construction Commission
(QBCC)
“ A CONTRACTOR‟S GUIDE TO REBUILDING AFTER A
FLOOD”
March 2015 – Page 4, rapid drying is recommended by QBCC for
such events.
5.3 Additional information relied on
The parties‟ respective submissions.
The relevant terms of the policy and certificate of insurance
Recommendation | Case number: 674632 Page 10 of 10