Home / Commonwealth Insurance Limited / Determination 673729

Determination 673729

Claim decline - cracking and movement damage to home

FirmCommonwealth Insurance Limited
Decided2020-07-17
ProductGeneral Insurance · Home building and contents
OutcomeFor the firm
Amount awarded—
Non-financial loss—
Amount claimed—
SourceAFCA PDF

Summary

The complainant claimed for cracking and movement damage to his home, attributing it to a broken stormwater drain. AFCA's panel found no sudden leak or accident was established and the damage was gradual, so the gradual damage exclusion applied and it ordered nothing.

The complainant must prove a sudden and unexpected escape of liquid or accident, and the insurer established the gradual loss exclusion because the cracking and movement developed over time.

Issues

Subjects and remedies

home or building damageno remedy

Related

All Commonwealth Insurance Limited determinations · Find similar determinations

Text of the determination

Determination Case number 673729 Financial firm Commonwealth Insurance Limited Determination | Case number: 673729 Page 2 of 13 Case number: 673729 17 July 2020 Determination overview 1.1 Complaint The complainant holds a home and contents insurance policy with the financial firm (insurer). He lodged a claim against his policy in August 2018 as his property had suffered damage due to cracking and movement, describing a storm water drain as the problem. The insurer obtained experts’ reports and deemed the cause of the damage to be general movement unrelated to any leak. It says the damage occurred over time and is excluded under the policy. The complainant obtained his own reports which indicated leaks from the stormwater drain were the cause of damage. On this basis he seeks for the insurer to pay the claim for cracking and movement damage in full. 1.2 Issues and key findings Is the insurer entitled to refuse the claim? The insurer is entitled to refuse the claim because the available information suggests the damage is not a result of a risk insured against by the policy. An event or series of events has not been identified which resulted in a sudden leak or otherwise caused the damage. Rather, the damage appears gradual in nature and is excluded under the policy. 1.3 Determination This determination is in favour of the insurer. The insurer is not required to take any further action. Determination | Case number: 673729 Page 3 of 13 2 Reasons for determination There has been a full exchange of all material information relied on for the purposes of this determination and each party has had the opportunity to address any issues raised by the other. This decision has been made by a Panel consisting of an Ombudsman, a representative with extensive experience in the insurance industry and another representative with extensive experience in consumer claims. The decision follows consideration of all the material exchanged. It is based on what is fair in all the circumstances having regard to the relevant legal principles, terms of the policy, good industry practice including codes of practice and previous decisions where applicable. While the parties have raised numerous issues in their submissions, for the purposes of this determination, commentary has been restricted to those issues considered directly relevant to the outcome. 2.1 Is the insurer entitled to refuse the claim? Policy covers accidental loss or damage and escape of liquid The complainant bears the onus of establishing a valid claim to which the policy responds. The policy covers damage resulting from certain insured events, including loss or damage caused by the sudden and unexpected escape of liquid. The policy also offers optional accidental damage cover, which provides cover for loss or damage to the building caused by an accident at the insured address. The policy does not define accident therefore the ordinary meaning applies, that is something sudden, unforeseen, unintended and unexpected. Of note, under accidental damage, where the cause of damage falls under an insured event, the claim is assessed under that event. This means if the cause of damage is the sudden and unexpected escape of liquid, the event specific conditions and exclusions apply. Complainant says cracking damage was caused by a broken stormwater drain The complainant is claiming for cracking damage to the home. He says the cause of damage is the escape of liquid from a damaged stormwater drain. The available information shows the property had previously undergone repairs, underpinning with resin injection, in 2013 designed to rectify movement related issues. Recent property inspection reports suggest movement damage was stable until July 2018 when ‘heavy signs of movement’ were noted. Determination | Case number: 673729 Page 4 of 13 While there is history of building movement at the insured property, the complainant maintains the more recent exacerbation of cracking was caused by an unexpected and unintended leaking storm water drain. Insurer says damage is a result of excluded causes The parties do not dispute the property has suffered damage in the form of cracking, typically associated with ground movement. The dispute is over the cause of the damage. The submissions include opinions and reports from forensic and geotechnical engineers, plumbers, and other experts associated with the building trade. A summary of these submissions is included in section 3 of this determination. The insurer’s builder (MC) assessed the damage in August 2018. MC says the extent of cracking, present in almost every room, indicates cracking has been occurring over time, most likely as a result of land movement. MC reports the tenant noticed cracking damage two years ago and says it has since worsened. MC also noted a rear downpipe was disconnected yet does not suggest this is a cause. The insurer also engaged an engineer (SF) for comment. SF arranged a floor level survey which showed a high level at the front of the home, with a fall towards other perimeter walls. SF says a leak would cause uplift, rather than fall, and concluded that a leak is not the cause of the cracking. SF says the damage is attributable to typical soil movements due to seasonal and climatic changes in moisture content, exacerbated by the soil drying impact of a large tree on the western side. SF was later invited to provide further comment following provision of plumbing reports. SF notes cracks in the stormwater drain do not correspond with localised heave, movement or damage. SF notes the complainant says the cracking suddenly increased in July 2018, yet cracks have not noticeably worsened. The insurer says it is entitled to refuse the claim as there is no insured event which caused the damage. It says there was no sudden and unexpected escape of liquid, and the damage is a result of excluded causes, including gradual damage or loss of any kind. The specific exclusions relied upon by the insurer are included in section 3 of this determination. Complainant provided a number of reports to support his position The complainant arranged a plumber (AL) to conduct an inspection of the condition of pipes. AL describes the northern stormwater drain as in poor condition, with misalignments and root intrusions. AL says a blockage will cause stormwater to back up in the drain and potentially leak into the ground. The complainant says the findings of the insurer’s expert , SF, are based on incorrect assumptions regarding the reactivity of soil. He says SF assumed the soil is moderately reactive clay, or a Class M site, whereas the soil is actually less reactive. Determination | Case number: 673729 Page 5 of 13 The complainant had engaged a geotechnical engineer, SG, to determine soil classification and moisture conditions. In an email dated 13 March 2020, SG say properties the area are typically Class S sites and are not susceptible to shrinkage or swell. SG say trees at such sites do not accentuate soil movement. However, in its initial report of 25 June 2019 SG classify the site as Class M, the same classification assumed by SF. This classification was made on the basis of soil testing at the site and is presumably more accurate than relying on regional norms. SG also noted a variance in soil moisture which it says is typical of damaged services. It says this would result in heave on the western and southern parts of the site and shrinkage elsewhere and considers this a factor in damage. SG also considers undersized footings to be a factor. The complainant also supplied the opinion of expert geologist IW. It is unclear if IW viewed all relevant reports, yet commentary appears suitably specific. IW says relatively high moisture content in boreholes near tall trees shows the soil dying impact of these trees is negligible. IW says heave occurs where minor soil moisture content develops relative to surrounding drier soils. IW notes where the accumulation of moisture is excessive, soil cohesiveness is weakened, and this results in subsidence. IW is of the view water migration from the north west has washed out fine soil particles, resulting in subsidence related damage to the building. IW also says the timeframe, with damage worsening into winter consistent with increased seasonal rainfall, supports this view. However, I note the increased movement in winter would also correspond with seasonal movement on clay soils as suggested by SF. Experts hold conflicting views on the impact of a leak and tree on western side The impact of a large tree on the western side of the property is disputed by the parties. SF suggests the impact is significant, while SG and IW suggest the impact would be minimal. I note this tree is located close to the south western corner of the property, an area largely unimpacted by movement. An engineer (IL) had been engaged in relation to an earlier leak, and subsequent repairs, in 2013. IL found water escaping from a broken pipe had reduced the shear capacity of soil, leading to localised subsidence. While relating to a different event, this is relevant as it describes a leak resulting in localised damage , which is not currently evident. SG do not comment on the specific leak yet says damaged services would result in heave on the western and southern parts of the site and shrinkage elsewhere. The Panel notes the western side of the property has seen settlement, rather than heave. Determination | Case number: 673729 Page 6 of 13 Finally, IW says water migration from a leak on the north western side of the property has washed our fine particles, causing the subsidence which is impacting the western side of the building. This view is not shared among other experts, and IL describes no similar action as a result of the 2013 leak. Information not sufficient to establish a leak or accident caused the damage While the experts mention the impact of a service leak on the soil and draw a link between the cracked drain pipe and a leak, there is no information to show the type and nature of that leak. The insured event requires the complainant to establish a sudden and unexpected escape of liquid. The presence of a leak is an assumption based on the plumber’s report showing misaligned stormwater drainage that has been affected by tree roots. The Panel is not satisfied this alone establishes a leak was a possible cause of the damage. There is no information to show how much rain had fallen in 2018 or that water was actually escaping at that location at a sudden and unexpected rate. As noted above, the complainant also has cover for accidental damage, that is sudden, unexpected and unforeseen. The Panel accepts that the recent cracking would have been a surprise to the complainant, given the relatively recent resin injections carried out to prevent further movement. However, for the policy to respond to accidental damage it requires there to be a sudden and unexpected accident that caused the damage. The Panel is not satisfied the information establishes this. Even if I was, the Panel is satisfied the insurer has established an exclusion applies. Damage has occurred gradually Inspection reports from July 2018 onward report heavy signs of movement in the kitchen and bedrooms. Earlier reports reference cracks due to movement, and problems closing doors, but do not describe heavy movement. Of note, this heavy movement is widespread, impacting all bedrooms and the kitchen. The movement is not isolated to areas impacted by the leak. A report prepared by the insurer’s builder (MC) says the tenant advised cracking was noticed approximately two years earlier (in 2016) and has worsened over time. However, in the SF report tenants are noted as first observing cracks in late 2017. A tenant’s notice is not necessarily a n indication of when the cracking occurred however the available information does show it has been an ongoing problem for some time with no identifiable cause. The Panel noted MC photographed the western wall on 10 August 2018. The same wall was photographed by the insurer’s assessor (GD) in August 2019. Careful inspection of these photographs does not depict any change in the existing cracking. This supports the conclusion that the cracking has bee n gradual overtime. Determination | Case number: 673729 Page 7 of 13 The available information suggests cracking and movement has gradually occurred over time. The stormwater system is described as in an overall poor condition, with numerous root intrusions and misalignments. An event or series of specific events has not been identified which may have resulted in a sudden leak, or leak of heightened severity. The Panel considers the damage has occurred as a result of either a gradual leak, or some other gradual cause. In these circumstances the policy does not respond to the complainant’s loss. Determination | Case number: 673729 Page 8 of 13 3 Supporting information 3.1 Our Approach It is an accepted principle of general insurance law that the insured bears the onus to establish, on the balance of probabilities, that they have suffered a loss caused by an event to which the policy responds. This is known as a prima facie claim. Once so established, the onus shifts to the insurer to prove, on the balance of probabilities, that an exclusion applies if it seeks to deny or limit its liability for the loss 3.2 Case law and proximate cause Case law establishes: The proximate cause of the loss is the dominant or effective or operative cause of the loss whether that be the last in time or the sole cause. If there are several causes operating contemporaneously, each must be examined for the qualities of reality, predominance and efficiency as the active, efficient cause that sets a relevant chain of events in action. If one cause would have caused the harm in any case, and the other would not have done so in the absence of the first, the first is the proximate cause. A common-sense approach is taken to determine proximate cause. 3.3 Relevant policy terms Insured events - Escape of liquid What is covered: Your building and/or contents are covered for loss or damage caused by the sudden and unexpected escape of liquid from any: … • fixed water pipe (but not a garden hose); What is not covered You are not covered under this Insured Event for: … • loss or damage caus ed by any gradual escape of liquid; … Your building and/or contents are not covered under this Insured Event for loss or damage as described in the General Exclusions listed on pages 75 to 78. Accidental Damage Cover What is covered You are covered for loss or damage to your building and/or contents caused by an accident at your insured address. Determination | Case number: 673729 Page 9 of 13 What is not covered … If the cause of the loss or damage falls under an Insured Event in the policy, the loss or damage will be assessed under that Insured Event. Your building and/or contents are not covered under this Optional Cover for loss or damage as described in the General Exclusions listed on pages 75 to 78. General Exclusions Under this policy there is no cover provided for any loss, damage or liability caused directly or indirectly by or in any way connected with: … 4. wear and tear and lack of maintenance, including rust, corrosion and deterioration (except in some instanc es relating to the Insured Events ‘Escape of liquid’ and ‘Legal liability’ claims); … 13. mould, toxic mould, mildew, wet or dry rot, rising damp or dampness; … 35. gradual loss or damage of any kind; … 3.4 Floor level survey – comparative summary Item Summary Prior claim expert (IL) Floor level survey (summary) 5 September 2013  0 datum (highest point) is front door (south side)  N/A south east corner of building  - 25 mm at north east corner of building  - 21 mm at north west corner of building  - 50 mm at south west corner of bedroom 3 , - 68 mm at north east corner of bedroom 4  - 53 mm at south west corner of building  - 10 mm at north east corner of master bedroom (central to home) Insurer’s expert (S) Floor level survey (summary) 14 December 2018  0 datum (highest point at 58 mm) is adjacent front door (south side) (58 mm)  - 15 mm at south east corner of building (43mm)  - 24 mm at north east corner of building (34 mm)  - 45 mm at north west corner of building (13 mm)  - 44 mm at west ext ension corner (12 mm)  - 53 mm at south west corner of building (5 mm)  - 10 mm at north east corner of master bedroom (central to home) (48 mm) Determination | Case number: 673729 Page 10 of 13 3.5 Summary of inspection reports Item Summary Summary of routine inspection reports 5 October 2 016  Property maintained in good condition.  Hallway and second bathroom doors do not close. 28 June 2017  Property is showing signs of age throughout.  Laundry door is not locking again. 23 January 2018  Property is showing signs of age throughout.  Cracks due to movement in entrance hall. 17 July 2018  Property is showing heavy signs of movement evident in visible movement cracks.  Movement cracks in kitchen and bedroom 2, 3 and 4 as per last inspection. 27 February 2019  Property is showing heavy signs of movement evident in visible movement cracks.  Movement cracks in kitchen and bedroom 2, 3 and 4 as per last inspection. 2 September 2019  Property is showing heavy signs of movement evident in visible movement cracks.  Movement cracks in kitchen as per last inspection. 3.6 Summary of expert reports Item Summary Prior claim expert (IL) Structural Inspection Report 17 September 2013  Along all elevations, differing colours and thicknesses of mort ar joints depicted repair works to past cracking.  Based on the visual inspection and information obt ained to date, we confirm all recorded cracking and movement within and local to the bedroom 3 and 4 areas is primarily attributable to a fracture within the stormwat er drainage system. Movement to the structure elsewhere is a result of natural settlement over a prolonged period of time only.  One trial pit excavated adjacent to the front elevation confirmed sand made up the first one metre of soil, with a clay layer situated below. When abnormally saturated, the bond (commonly referred to as “bridges) between the sand particles can fail. The shear capacity is in turn reduced and subsidence occurs. Water exiting the fractured stormwat er system below bedrooms 3 and 4 has therefore resulted in the significant drop in flooring level within the local area .  Based upon our trial pit, we envisage foundations to be bearing upon a sand layer. Insurer’s builder (MC) Damage assessment 10 August 2018 Caus e / Circumstances (How damage occurred and caus es)  According to the client damage occurred on 13/06/ 2018 as a result of Escape of Liquid. Determination | Case number: 673729 Page 11 of 13 Item Summary  Client has advis ed MC that Tenant advised he noticed cracking on many internal walls and external brick work approx. 2 years ago, cracks have gotten worse over time.  Cracking to internal wall was present in almos t every room of the d welling.  Extent of cracking indicates this has been occurring over an extended period of time, possibly over 2 - 3 years most probably due to land movement.  It was not ed rear down pipe does not appear to be connected correctly into the s torm water and area was wet at time of inspection. Insurer’s plumber (P B ) CCTV inspection 2 September 2019 Storm Water Drainage  1 x Tree root affecting the rear LHS.  1 x Minor misalignment affecting the rear.  1 x Fracture affecting the front RHS.  During our CCTV inspections we found garage gutters constantly overflow due to having no downpipes servicing them.  Large fracture at front RHS where earthenware drain meets 90mm PVC. Sewer Water Drainage System  During our CCTV inspections we found sewer drains ar e in a good condition. Complainant’s plumber (AL) CCTV inspection 18 February 2020  Stormwater piping along the no rth side of the hous e is run in ea rthenware and is in poor condition, with typical misalignments.  There is a complete blockage two metres back from the northwest corner of the house.  There is a broken fitting as the [ northwest corner ] downpipe drain conne cts with the drain running past.  There is a broken pipe and heavy root intrusion just past the gate. The piping is misaligned in several place s as it he ads down the yard towards W Avenue.  Attempted to trace the lower line, but it is completely blocked wit h dirt about 1 metre in from the inspection shaft towards the house.  Inspected the drain out towards Wy Avenue and the barrel drain at the nat ure strip. Detected that the drain is brok en and with a very heavy root intrusion at the edge of the footpath. Insurer’s expert (S F ) Report 20 December 2018 Floor Level Survey  The patterns of the contours indicat e there is a high area along the south side of the house around the entry porc h area where the footings are protected from external garden / unsealed ground areas by the porch slab, and general fall towards the other perimeter walls of the house. The contours indicated a notable fall from the c ent re of the house towards the western side / wall of the house which is in the direction of trees along the west wall and the very large tree (over 20m high and overhanging the house) on the west street boundary of the property. The Event:  S note that giv en the reactive nature of the foundation soils at the subject site, we would have expected to have observed footing heave or uplift movements of the footings around the location where any stormwater Determination | Case number: 673729 Page 12 of 13 Item Summary pipes were damaged or leaking if water leaks were affecti ng the soils from an increase of the moisture content; and therefore swelling of the reactive foundation soils (refer to the Site Geology and Soil Reactivity section above) if any damage to the stormwat er drainage system was the cause of recent building mo vement and damage. Given that the observed floor / footing movement along the northern side of the house has been the opposite and a relative settlement, and that the largest building movement is a fall / settlement towards the western side of the house t hen is it S’s opinion that any damage or leaking of the stormwater system around the house is not the cause, nor has it contribut ed to the observed building movement and damage.  Further, it is S’s opinion that there is no specific rainfall / storm event th at has caused or contributed to the observed building movement and damage. Conclusions  That any damage or leaking of the stormwater system around the house is not the cause, nor has it contributed to the observed building movement and damage. There has bee n no specific rainfall / storm event nor any other event that has caused or contributed to the observed building movement and damage.  The observed building settlement movements and associated crack damage is historic and is attributable to typical and expe cted ongoing reactive soil movements due to seasonal and climatic moisture changes, greatly accentuated by the large trees in close proximity to the west perimeter footings of the house. Complainant’s expert (SG) Report 25 June 2019  We have received instruction to conduct a series of external test bores and footing probes to determine foundation substrate and soil moisture conditions.  This site is classified as Class M in accordance with AS2870 – 2011.  At 1.8m depth at the front and western sides of t he dwelling the soil moisture content is considered to be higher than normal and lower than normal elsewhere. This is typical of damaged services which in turn would be resulting in relative heave of the moderat ely reactive foundation zone clay soils on th e western and front parts of the site and relative shrinkage elsewhere. This is considered to be a factor in the existing damage.  The concrete strip footings supporting the dwelling (refer to FP1 - FP3) have overall founding depths of 550 - 800mm, depth of con crete of 200mm and are founded in natural silty sand. This compares to a minimum 400mm depth of conc rete for a masonry veneer dwelling on a site with this soil type (as stipulated by AS2870 – 2011). These relatively undersized footings are considered to be a factor in the existing damage . Insurer’s expert (S F ) Supplement ary report 27 September 2019 Comments  We have reviewed our Floor Level Survey which we took during our inspection in December 2018 and note that we do not see significant building footing movement or damage to the house around the locations where the earthenware pipes have been found to be lea king. As discussed in our report, the behaviour of the reactive foundation soils at the subject property would mean that we would expect to observe Determination | Case number: 673729 Page 13 of 13 Item Summary localised footing heave movements and loc alised damage to the internal linings and exterior cladding if wat er leaks from the pipes was causing building footing movements.  We have also reviewed the photographs of the current crack damage to the house in the G D and P B reports and have compared them with the photographs we took during our inspection in December 2018 (9 months ago). We note that the size and extent of the crack damage does not appear to have changed significantly over the past nine months . Conclusions  T he crack damage and leaking of the eart henware stormwat er pipes at the property has not suddenly occurred and has likely been occurring for a long period of time (years).  The building movement and damage has been gradually occurring. Complainant’s expert (SG) Supplement ary r eport 25 June 2019  W e can confirm that the Baxter Formation Sandstone and derived Sandy Soils in the F area are either non - reactive or subject to slight reactivity pending on minor proportions of clay cont ained within the sand  Sites in this area would generally be classified as ‘S’ and moisture changes would not result in significant g eometric shrinkage or swell.  The influence of trees is restricted to possible mechanical int erferenc e of root systems with footings or paving. Trees would will not accent uate the soil movement in a sandy soil profile. 3.7 Other relevant material considered and relied up  Parties submissions, summaries and correspondence  Photographs  Geological survey maps  Influence of trees on soil moisture, dwellings and pavements (report)  Comparison of plumber CCTV reports  Geologist review of evidence

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.