Home / IAG / Determination 673049

Determination 673049

Insurer refused home damage claim from leaking pipes and soil movement, saying damage was gradual and not a single claimable event

FirmIAG
Decided2020-07-29
ProductGeneral Insurance · Home building and contents
OutcomeFor the complainant in part
Amount awarded$80,000
Non-financial loss—
Amount claimed$117,607
SourceAFCA PDF

Summary

The complainant claimed about $117,606.81 for structural damage to his home, which he attributed to a leaking neighbouring sewer and the insurer declined as gradual damage. AFCA found the damage accidental and not excluded, but limited the insurer's liability to two-thirds of the repair cost and ordered $80,000.

The insurer could not prove an exclusion applied or identify when the damage occurred, though damage that predated the policy inception could be excluded, justifying a two-thirds apportionment.

Issues

Subjects and remedies

home or building damagepay claim

Related

All IAG determinations · Find similar determinations

Text of the determination

Determination Case number 673049 Financial firm Insurance Australia Limited Determination | Case number: 673049 Page 2 of 13 Case number: 673049 21 July 2020 1 Determination overview 1.1 Complaint The complainant (broker and complainant will be referred to as complainant) lodged a claim on 3 September 2018 sunder his home and contents insurance policy held with the financial firm (insurer), for damage to his home caused by a leaking pipe. The insurer has denied the claim saying that the available information indicates the damage occurred over time and not due to a single claimable event under the policy. The complainant disputes the insurers decision and maintains the damage occurred due to a leaking pipe on a neighbouring property. 1.2 Issues and key findings Has the complainant established a claim within the terms of the policy? The complainant has established a claim within the terms of the policy as it is accepted that the damage was accidental damage in that it was unintended and unexpected. Is the insurer entitled to refuse payment of the claim? The insurer is not entitled to refuse the claim but can limit its liability as I am satisfied some of the damage occurred before commencement of the policy. It is fair in the circumstances that the insurer be entitled to limit its liability to two thirds of the cost of the assessed damage. 1.1 Determination This determination is in partially in favour of the complainant. The insurer is to pay the complainant $80,000 in discharge of its liability under the terms and conditions of the policy. Determination | Case number: 673049 Page 3 of 13 2 Reasons for Determination There has been a full exchange of all material information relied on for the purposes of this determination and each party has had the opportunity to address the issues raised. This determination follows consideration of all the relevant material. The determination is based on what is fair in all the circumstances, having regard to the relevant law, terms of the policy, good industry practice, codes of practice and previous decisions (which are not binding). While the parties have raised numerous issues in their submissions, for the purposes of this recommendation, commentary has been restricted to those issues which are considered directly relevant to the outcome only. 2.1 Has the complainant established a claim within the terms of the policy? Complainant has the onus to establish claim within the terms of the policy It is established insurance law that an insured has the initial onus to establish on the balance of probabilities (that is more likely than not) that the claim that falls within cover under the terms of the policy. This is called a prima facie claim. Once established the onus shifts to the insurer to show, on the balance of probabilities, it is entitled to otherwise deny the claim. The complainants Home and Contents policy was incepted on 19 February 2017 and provides cover for accidental loss or damage. The policy does not define accidental however it is generally accepted to mean damage that is unintended and unexpected. The complainants representative in a final submission has referred to a specific escape of liquid provision and policy wording. The PDS exchanged does not contain such wording. The policy is an accidental damage policy. Complainant has established a prima facie claim The complainant says he was first alerted to possible damage in July 2017 by a builder during a separate claim. He appointed a plumber (AM) who attended the property on 27 November 2017. AM identified several issues, saying the most prominent issue was a ‘gutter pop’ not sealed at a rain head and separated sealant is the fault of water ingress between brickwork and render causing the render to crack. Both parties now agree that a leak from underground sewer drain connected to an outside laundry on a neighbouring property had affected the soil moisture levels. The was on the western side of the dwelling. The complainant acknowledges there was some seasonal movement in the property but maintains the additional damage observed was most likely caused by the leaking sewer drain. Determination | Case number: 673049 Page 4 of 13 The insurers engineers, say the leak and damage was likely occurring over a period of several years although the complainant says he only became aware of the damage in July 2017. Google images indicate the laundry was removed between 22 May 2017 and 1 September 2017. It is likely the damage occurred as the soil dried out after the laundry was removed. That is, there is no evidence the damage was occurring prior to the inception. In the circumstances I am satisfied the complainant has established the damage falls within the terms of the policy as accidental damage. 2.2 Is the insurer entitled to refuse payment of the claim? To deny the claim the insurer will need to establish that a relevant exclusion applies. The insurer in denying the claim has said the damage occurred over time and not because of a single claimable event. It has subsequently said that it declined the claim based on exclusions within the policy although it has not clearly identified which of the specific general exclusions it is relying on. It is not AFCA’s role to work through the policy to identify an exclusion for the insurer. Based on the submissions made it would appear the insurer is relying on the following limitations or exclusions:  Cover for landslide and subsidence is only available if the loss or damage occurs within 72 hours of the liquid escaping from a fixed pipe  Loss or damage caused by settling, shrinkage or any earth movement  Any event that does not occur within the period of insurance Expert reports show several long-term water leaks The available information shows various cracking and movement damage to the entire property, i nternally and externally. The insurer appointed engineer AA first to assess the cause and notes the following:  Inherent volatility of the naturally occurring reactive clay founding soils (to change in moisture condition)  Historic sewer leakage originating within the western side neighbouring property, which was able to occur alongside the Insured's dwelling over a prolonged period of time before it was eventually rectified (recently).  Existing site landscape and drainage conditions allowing surface rainwater runoff to be directed toward and potentially migrate into the sub floor area of the dwelling along the western side of the property, during any significant rainfall event experienced in the region over the life of the dwelling.  Water leakage via the hydronic heating plant located to the external western side of the dwelling, which has potentially allowed water to permeate into the sub floor area of the dwelling locally. Determination | Case number: 673049 Page 5 of 13 The insurers second engineer IM attended and noted the above issues also, along with the following:  Plumbing testing undertaken for the insured in November 2017 concluded the sewer was sound (being suspended above ground and therefore visible beneath the floor), however it does not appear they have tested the pipework between the building and the street.  The dwelling is constructed well elevated from the street at the front, and therefore with adequate fall away from the dwelling, it is possible that this pipe work is leaking, especially given the apparent heave recorded on the floor level survey and the compression movement within the ensuite immediately above.  It is also possible that this apparent upward movement is due solely to removal of a relatively small, albeit mature and developed street tree.  Another likely factor contributing to movement on the insured site is the effect of tree removal at the rear prior to construction.  The binding kitchen cupboard door is a function of differing footing movement between the stiffer perimeter footings and the intermediate pad footings supporting the central concrete stumps.  The hairline cracking to the feature wall is not currently structurally significant and could be a result of minor footing movement or concrete shrinkage. I note IM’s report identifies the possibility of a further leak between the building and the street. The insurer has not investigated this, nor has it conducted its own leak detection test. The complainant provided reports from builders MM, DL who in summary say, the movement to the property was caused by the neighbours leaking outside laundry which has since been removed. The complainant also had an engineer CM do a desk top review of the reports from IM and AA. CM considered:  changes in moisture content in reactive clay soil can cause major differential movement.  AA’s report identified possible external factors namely : > leaking neighbouring pipework, > existing landscaping and site drainage, > water leaking from hydronic heating unit > trees  IM had too much emphasis on past removed trees Determination | Case number: 673049 Page 6 of 13 I accept IM’s report on the trees causing damage is not consistent with the other experts reports and it is suggested as a possibility, rather than a certainty. What does not appear to be disputed it that there are several water leaks including the leak from the neighbouring property which did disturb the moisture content over a period of several years. Policy excludes cover for damage not occurring within the terms of the policy. The insurer is not responsible for damage that occurred prior to 19 February 2017 when the period of insurance commenced. What the insurer has not proved is the extent of any damage that occurred prior to 19 February 2019. Damage developed over time due to leak It is not possible from the available information to identify when the damage first commenced or how soon after the ongoing escape of liquid. The other leaks identified were unknown and went unchecked. That damage had occurred during the duration of the leaks. I accept the damage was most likely caused by a combination of the neighbour’s laundry leak, the hydronic heating unit leak and the lack of drainage around the water tanks allowing moisture to build in the highly reactive clay soul, causing movement at the property. The limitations within the policy have limited application as the insurer cannot say with any certainty when the loss or damage occurred. Although the policy limits cover to damage occurring within 72 hours of the liquid escaping, the leaks from the laundry were ongoing until at least 22 May 2017 while the other leaks were ongoing until at least they were identified. The policy does not say that the damage must occur within 72 hours of when the liquid first escapes as suggested in the report from AA. AA identifies that such damage typically develops over weeks or months. If this is the case it would have been occurring as the pipes were leaking. I accept that most likely some damage existed prior to commencement of the policy, to the western side of the property caused by the leaking pipe in the neighbouring property. I also accept that once the leak was repaired there would have been further damage commence within a short time due to the drying out of the soil. Determination | Case number: 673049 Page 7 of 13 Earth movement exclusion has limited application I accept the general exclusion for any earth movement applies to seasonal movement where the earth movement is the proximate cause of the damage. The proximate or dominant cause of at the least some of the damage, was most likely the escape of liquid as identified by the engineering reports. Such damage falls within cover under the policy as the earth movement was a consequence of the event covered under the terms of the policy. Fair in the circumstances that the Insurer contribute to the cost of repairs? The complainant has submitted a quotation for $117,606.81 for the structural and cosmetic repairs at the property from BBS. This includes an allowance for over $49,000 to relevel the property. There is a separate estimate of $180,000 to $220,000 from a builder although not details as to how that figure was reached. The insurer provided an early quote from M of $27,484.50. I accept the quote from BBS is a fairer representation of the likely cost of repairs at the property. The insurer must arrange a further leak detection as outlined in IM’s report from the front of the property to the street to determine if this sewer pipe is still problematic. The insurer is liable for any costs to investigate the leak. Otherwise I consider it fair in the circumstances that the insurer settles the claim by paying the complainant $80,000 representing approximately two thirds of the complainant’s quote. In determining this is a fair figure I have taken into account that most likely some of the damage was pre-existing due to the long-term nature of the leak from the neighbour’s property and some damage likely to be seasonal. Determination | Case number: 673049 Page 8 of 13 3 Supporting information 3.1 Relevant Law What is the proximate cause of a loss is a question of fact depending upon the circumstances of each case. Courts, in considering proximate cause, have clearly stated that it is not the first, or the last or the sole cause of a loss which is proximate: it is the effective or dominant or operative cause. If there are several causes of a loss operating contemporaneously, each must be examined for the qualities of reality, predominance and efficiency as the active, efficient cause that sets a relevant chain of events in action. If one cause would have caused the harm in any case, and the other would not have done so in the absence of the first, the first is the proximate cause. 3.2 Relevant extracts from expert reports Expert and date Key points FF engineer AA 3 October 2018  Determine the cause of damage  The damage that has occurred to the Insured's dwelling is consistent with differential footing movement.  The differential footing movement that has occurred due to Inherent volatility of the naturally occurring reactive clay founding soils (to change in moisture condition)  Historic sewer leakage originating within the western side neighbouring property, which was able to occur alongside the Insured's dwelling over a prolonged time before it was eventually rectified (recently).  Existing site landscape and drainage conditions allowing surface rainwater runoff to be directed toward and pot entially migrate into the sub floor area of the dwelling along the western side of the property, during any signific ant rainfall event experienced in the region over the lif e of the dwelling.  Water leakage via the hydronic heating plant located to the external western side of the dwelling, which has potentially allowed water to permeate into the sub floor area of the dwelling locally.  Differential footing movement and consequ ential damage/distress that has occurred to the fabric of the dwelling is believed to have developed over a period of many years, i.e. over a period of at least 2 - 3 years  - If the escapes of liquid identified above are in fact insurable events, differential footing movement and consequential building superstructure damage/distress would not typically occur within 72 hours of the events (i.e. within 72 hours of the first discharges Determination | Case number: 673049 Page 9 of 13 Expert and date Key points of water associated with the ongoing and/or int ermittent water leakage events) . Differential building movement resulting from such events would typically occur after weeks or months (not hours/days) of the result ant wat er accumulating alongside the footings i.e. subject to various factions including and not limited to volume of wat er, FF’s engineer IM 17 June 2019  The site soil is reactive; however, we do not know how reactive. Three hand - augured boreholes were excavated to just 1500mm, as is required by AS2870 and recorded clay, however we do not know what happens below this dep th. Our experience indicates the clays found in the region are moderately to highly reactive.  There is also some variation bet ween the mat erial found centrally and towards the front of the site compared to that at the rear. We would expect the rear of t he site to respond to moisture change more significantly than elsewhere.  Reactive soils change volume with a change in moisture content. Therefore, as a reactive or ‘clay’ soil becomes moister it expands and heaves lifting the footing supported by it.  Alternatively, if a clay soil dries, it shrinks and allows a settlement of the footings supported by it.  Plumbing testing undert aken for the insured in November 2017 concluded the sewer was sound (being suspended above ground and therefore visible beneath the floor), however it does not appear they have tested the pipework between the building and the street.  The dwelling is constructed well elevated from the street at the front, and therefore with adequate fall away from the dwelling, it is possible th at this pipe work is leaking, It is also possible that this apparent upward movement is due solely to removal of a relatively small, albeit mature and developed street tree.  The plumbing report also reports sub - floor moisture, possibly due to the tanks on the western side of the dwelling preventing flow of any surface moisture in the vicinity . R ecommend these tanks be emptied and lifted or dec ommissioned from the area. At the time of writing this report the owner had not yet undertaken this work, however indicated he would do so.  The owner’s leak det ection report also reported a gutter pop being not sealed adjacent to a rain - head. We assume this is adjacent to the powder room and are unsure if this has been addressed. We do not believe this is a source of render cracking however other damage may arise if this has not yet been addressed.  CCTV of the stormwater pipework indicated poor grade and that it was holding water, had a build - up of leaf litter and tree root ingress. It is not clear where this root ingress was found, however the owner indicated it was near the garage, we assume Determination | Case number: 673049 Page 10 of 13 Expert and date Key points adjacent the downpipe at the garage’s nort h western corner.  it has been identified that an exterior WC situated immediately adjacent to the powder room was removed between 2 2 May 2017 and 1 September 2017. It has also been suggested that this was serviced by defective pipework. It is thought that this pipe was leaking for some years and its removal, or absence of a leak has caused a downward movement in that vicinity which has contribut ed to the cracking damage experienced.  It is unclear how often this outside toilet was used or indeed how much of the sewer was defective. Test site 2 hand - augured by Saunders Consulting Group in (winter) July 2007 appears to have been in pr oximity to the powder room, and recorded ‘moist and stiff’ conditions, which was like Test site 1, towards the front and remote from the neighbour’s WC.  Given the insured sites sewer entry point is situated adjacent to the western boundary, it is plausibl e that the neighbour’s sewer is also aligned on the western side, it would therefore follow that the decommissioned WC pipe work extended across the rear of neighbouring building away from the insured dwelling. This together with being at the top of the d rain, could possibly diminish the wetting effect on the insured’s side of the boundary.  We certainly would not expect leakage from this pipe work to extend to the other side of the newer (insured) dwelling, nor back towards the garage. There is a masonry chimney on the neighbouring (western) property near the removed exterior WC and insured laundry. The footing of which, is very close to the insured boundary, supporting the need for the exterior WC to be plumbed away from the insured dwelling rather than down the side, and therefore adjacent to the insured dwelling. There was also no discernible damage to this chimney, which also supports the determination that this leakage only affected the immediate vicinity.  Another likely factor cont ributing to mov ement on the insured site is the effect of tree removal at the rear prior to construction. Large native trees can result in long - term drying of the foundation soils. Their removal results in wetting up of the previously desiccated soils, and a return to wetter moisture regime.  This may explain the footing designers, (assumed) original design to include screw - in - piles across the entire rear boundary. It is also possible that the screw in piles were deemed necessary to prevent adjacent services wit hin Edw ard Street, undermining the garage footing,  This movement may have increased to noticeable levels following the removal of the tree on the neighbouring site to the east and construction of a garage on that site. Despite this occurring in 2013/2014, the re bounding effect is very slow and normally takes several wint ers to manifest.  It could additionally be argued that the absence of leakage Determination | Case number: 673049 Page 11 of 13 Expert and date Key points caused through removal of a WC serviced by a problematic sewer had contributed to some movement in the immediate vicin ity only. We would expect this to extend no further than the Powder room, Laundry and Rumpus room. Given the relatively minor damage on the periphery of this area, this damage is likely to be contained to that at the junction bet ween the Powder room and Laundry only.  In the absenc e of any pipe work fractures in - front of the dwelling, we would conclude that this upward trend was the result of the street tree removal and a wetter regime following landscaping. This is only affecting the minor cosmetic dis ruption in the ensuite.  The binding kitchen cupboard door is a function of differing footing movement between the stiffer perimeter footings and the intermediate pad footings supporting the central concrete stumps.  The hairline cracking to the feat ure wa ll is not currently structurally significant and could be a result of minor footing movement or concrete shrinkage.  The moisture differential due to moisture under the perimeter in this area needs to be addressed at the earliest convenience. We have not assessed the possibility of ceiling/ flooring sag in this area, however con do so if necessary.  The exterior render cracking and disruption adjacent to the laundry and powder room is in our opinion primarily resultant on the nearby change in environment, u pon removal of the adjacent WC and sewer pipework. Cosmetic repairs to this masonry could be considered, however we would not recommend this until the drainage issues due to the positioning of the tanks be addressed, and any affected soils completely dry.  Render cracking and compression of the window frames on the dwelling’ eastern side between the alfresco and the garage has been caused by the elevation of the garage structure. This has been a gradual process due to the removal of trees at the rear of the insured and neighbouring eastern site and the capping of that area with a continuous concrete slab. Complainant’s engineer CM 25 September 2019  Based on the background history and information presented in both the abovementioned reports, reviewed and considered by this office, it is my opinion that the AA Engineering Report provides the best summaris ed findings and most accurate assessment of the likely cause of damage observed to dwelling.  The IM engineers report placed emphasis on the presenc e and past removal of trees (many years ago) as a significant contribution to the damage &/or distress observed to dwelling.  Trees (both presence of, and removal of) can and do definitely cause abnormal moisture conditions in reactive clay soils. Determination | Case number: 673049 Page 12 of 13 Expert and date Key points  However, in this case, given the loc ation of damage &/or distress to dwelling, and given the location of past tree removal, it is my opinion that others external factors, in particular leaking neighbouring plumbing, have likely contributed more significantly to the observed damage &/or distress to dwelling. Complainant’s builder MM 21 August 2018  The home has been affected by a broken pipe event which has since been repaired.  The damage evident is typical of a Broken Pipe event.  There is a row of Ornamental Pear trees planted along the East Side boundary that will likely cause future damage to the home. These trees should be removed or isolated to limit the future impact .  There is an open garden bed adjacent to the East side wall of the residence and this should be sealed to prevent water affecting the footing system in line with CSIRO BTF18 Perimeter Protection recommendations. Complainant’s plumber AM 27 November 2017  Visual inspection of suspended sewer drain proved ok and in sound condition. CCTV inspection of the stormwater drain showed areas that had poor grade and holding water, build up of leaf litter and tree root ingress.  Also, one small puncture, although it is not believed that this is the issue contributing to cracked render and dampness sub floor. It is believed that no surface drainage and wat er tanks stopping the flow of stormwater is the fault of sub floor dampness. A gutter pop not sealed a t a rain head and separated silicon sealant is the fault of water ingress between brickwork and render, causing the render to crack.  Raise tanks off ground onto a stand. Surface drainage pits. Seal flashings and pop. Complainant’s builder DL 9 April 2020  The cause of the damage to property was from the west side neighbouring property which has since rectified the problem. Over a prolonged period of time water was escaping damaged earthenware piping from an old out house building leaking water into the abov e - mentioned property, and now the ground has had time to dry out it has sunken under the weight of the dwelling as the ground shrinks back and settles Determination | Case number: 673049 Page 13 of 13

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.