Insurer refused home damage claim from leaking pipes and soil movement, saying damage was gradual and not a single claimable event
Text of the determination
Determination
Case number 673049
Financial firm Insurance Australia Limited
Determination | Case number: 673049 Page 2 of 13
Case number: 673049 21 July 2020
1 Determination overview
1.1 Complaint
The complainant (broker and complainant will be referred to as complainant) lodged a
claim on 3 September 2018 sunder his home and contents insurance policy held with
the financial firm (insurer), for damage to his home caused by a leaking pipe.
The insurer has denied the claim saying that the available information indicates the
damage occurred over time and not due to a single claimable event under the policy.
The complainant disputes the insurers decision and maintains the damage occurred
due to a leaking pipe on a neighbouring property.
1.2 Issues and key findings
Has the complainant established a claim within the terms of the policy?
The complainant has established a claim within the terms of the policy as it is
accepted that the damage was accidental damage in that it was unintended and
unexpected.
Is the insurer entitled to refuse payment of the claim?
The insurer is not entitled to refuse the claim but can limit its liability as I am satisfied
some of the damage occurred before commencement of the policy.
It is fair in the circumstances that the insurer be entitled to limit its liability to two thirds
of the cost of the assessed damage.
1.1 Determination
This determination is in partially in favour of the complainant.
The insurer is to pay the complainant $80,000 in discharge of its liability under the
terms and conditions of the policy.
Determination | Case number: 673049 Page 3 of 13
2 Reasons for Determination
There has been a full exchange of all material information relied on for the purposes
of this determination and each party has had the opportunity to address the issues
raised.
This determination follows consideration of all the relevant material. The
determination is based on what is fair in all the circumstances, having regard to the
relevant law, terms of the policy, good industry practice, codes of practice and
previous decisions (which are not binding).
While the parties have raised numerous issues in their submissions, for the purposes
of this recommendation, commentary has been restricted to those issues which are
considered directly relevant to the outcome only.
2.1 Has the complainant established a claim within the terms of the policy?
Complainant has the onus to establish claim within the terms of the policy
It is established insurance law that an insured has the initial onus to establish on the
balance of probabilities (that is more likely than not) that the claim that falls within
cover under the terms of the policy. This is called a prima facie claim. Once
established the onus shifts to the insurer to show, on the balance of probabilities, it is
entitled to otherwise deny the claim.
The complainants Home and Contents policy was incepted on 19 February 2017 and
provides cover for accidental loss or damage. The policy does not define accidental
however it is generally accepted to mean damage that is unintended and unexpected.
The complainants representative in a final submission has referred to a specific
escape of liquid provision and policy wording. The PDS exchanged does not contain
such wording. The policy is an accidental damage policy.
Complainant has established a prima facie claim
The complainant says he was first alerted to possible damage in July 2017 by a
builder during a separate claim. He appointed a plumber (AM) who attended the
property on 27 November 2017. AM identified several issues, saying the most
prominent issue was a ‘gutter pop’ not sealed at a rain head and separated sealant is
the fault of water ingress between brickwork and render causing the render to crack.
Both parties now agree that a leak from underground sewer drain connected to an
outside laundry on a neighbouring property had affected the soil moisture levels. The
was on the western side of the dwelling. The complainant acknowledges there was
some seasonal movement in the property but maintains the additional damage
observed was most likely caused by the leaking sewer drain.
Determination | Case number: 673049 Page 4 of 13
The insurers engineers, say the leak and damage was likely occurring over a period
of several years although the complainant says he only became aware of the damage
in July 2017. Google images indicate the laundry was removed between 22 May 2017
and 1 September 2017. It is likely the damage occurred as the soil dried out after the
laundry was removed.
That is, there is no evidence the damage was occurring prior to the inception. In the
circumstances I am satisfied the complainant has established the damage falls within
the terms of the policy as accidental damage.
2.2 Is the insurer entitled to refuse payment of the claim?
To deny the claim the insurer will need to establish that a relevant exclusion applies.
The insurer in denying the claim has said the damage occurred over time and not
because of a single claimable event.
It has subsequently said that it declined the claim based on exclusions within the
policy although it has not clearly identified which of the specific general exclusions it is
relying on. It is not AFCA’s role to work through the policy to identify an exclusion for
the insurer. Based on the submissions made it would appear the insurer is relying on
the following limitations or exclusions:
Cover for landslide and subsidence is only available if the loss or damage occurs
within 72 hours of the liquid escaping from a fixed pipe
Loss or damage caused by settling, shrinkage or any earth movement
Any event that does not occur within the period of insurance
Expert reports show several long-term water leaks
The available information shows various cracking and movement damage to the
entire property, i nternally and externally. The insurer appointed engineer AA first to
assess the cause and notes the following:
Inherent volatility of the naturally occurring reactive clay founding soils (to change
in moisture condition)
Historic sewer leakage originating within the western side neighbouring property,
which was able to occur alongside the Insured's dwelling over a prolonged period
of time before it was eventually rectified (recently).
Existing site landscape and drainage conditions allowing surface rainwater runoff
to be directed toward and potentially migrate into the sub floor area of the dwelling
along the western side of the property, during any significant rainfall event
experienced in the region over the life of the dwelling.
Water leakage via the hydronic heating plant located to the external western side
of the dwelling, which has potentially allowed water to permeate into the sub floor
area of the dwelling locally.
Determination | Case number: 673049 Page 5 of 13
The insurers second engineer IM attended and noted the above issues also, along
with the following:
Plumbing testing undertaken for the insured in November 2017 concluded the
sewer was sound (being suspended above ground and therefore visible beneath
the floor), however it does not appear they have tested the pipework between the
building and the street.
The dwelling is constructed well elevated from the street at the front, and therefore
with adequate fall away from the dwelling, it is possible that this pipe work is
leaking, especially given the apparent heave recorded on the floor level survey and
the compression movement within the ensuite immediately above.
It is also possible that this apparent upward movement is due solely to removal of a
relatively small, albeit mature and developed street tree.
Another likely factor contributing to movement on the insured site is the effect of
tree removal at the rear prior to construction.
The binding kitchen cupboard door is a function of differing footing movement
between the stiffer perimeter footings and the intermediate pad footings supporting
the central concrete stumps.
The hairline cracking to the feature wall is not currently structurally significant and
could be a result of minor footing movement or concrete shrinkage.
I note IM’s report identifies the possibility of a further leak between the building and
the street. The insurer has not investigated this, nor has it conducted its own leak
detection test.
The complainant provided reports from builders MM, DL who in summary say, the
movement to the property was caused by the neighbours leaking outside laundry
which has since been removed.
The complainant also had an engineer CM do a desk top review of the reports from
IM and AA. CM considered:
changes in moisture content in reactive clay soil can cause major differential
movement.
AA’s report identified possible external factors namely :
> leaking neighbouring pipework,
> existing landscaping and site drainage,
> water leaking from hydronic heating unit
> trees
IM had too much emphasis on past removed trees
Determination | Case number: 673049 Page 6 of 13
I accept IM’s report on the trees causing damage is not consistent with the other
experts reports and it is suggested as a possibility, rather than a certainty.
What does not appear to be disputed it that there are several water leaks including
the leak from the neighbouring property which did disturb the moisture content over a
period of several years.
Policy excludes cover for damage not occurring within the terms of the policy.
The insurer is not responsible for damage that occurred prior to 19 February 2017
when the period of insurance commenced. What the insurer has not proved is the
extent of any damage that occurred prior to 19 February 2019.
Damage developed over time due to leak
It is not possible from the available information to identify when the damage first
commenced or how soon after the ongoing escape of liquid. The other leaks identified
were unknown and went unchecked. That damage had occurred during the duration
of the leaks.
I accept the damage was most likely caused by a combination of the neighbour’s
laundry leak, the hydronic heating unit leak and the lack of drainage around the water
tanks allowing moisture to build in the highly reactive clay soul, causing movement at
the property.
The limitations within the policy have limited application as the insurer cannot say with
any certainty when the loss or damage occurred. Although the policy limits cover to
damage occurring within 72 hours of the liquid escaping, the leaks from the laundry
were ongoing until at least 22 May 2017 while the other leaks were ongoing until at
least they were identified.
The policy does not say that the damage must occur within 72 hours of when the
liquid first escapes as suggested in the report from AA. AA identifies that such
damage typically develops over weeks or months. If this is the case it would have
been occurring as the pipes were leaking.
I accept that most likely some damage existed prior to commencement of the policy,
to the western side of the property caused by the leaking pipe in the neighbouring
property. I also accept that once the leak was repaired there would have been further
damage commence within a short time due to the drying out of the soil.
Determination | Case number: 673049 Page 7 of 13
Earth movement exclusion has limited application
I accept the general exclusion for any earth movement applies to seasonal movement
where the earth movement is the proximate cause of the damage.
The proximate or dominant cause of at the least some of the damage, was most likely
the escape of liquid as identified by the engineering reports. Such damage falls within
cover under the policy as the earth movement was a consequence of the event
covered under the terms of the policy.
Fair in the circumstances that the Insurer contribute to the cost of repairs?
The complainant has submitted a quotation for $117,606.81 for the structural and
cosmetic repairs at the property from BBS. This includes an allowance for over
$49,000 to relevel the property. There is a separate estimate of $180,000 to $220,000
from a builder although not details as to how that figure was reached. The insurer
provided an early quote from M of $27,484.50.
I accept the quote from BBS is a fairer representation of the likely cost of repairs at
the property.
The insurer must arrange a further leak detection as outlined in IM’s report from the
front of the property to the street to determine if this sewer pipe is still problematic.
The insurer is liable for any costs to investigate the leak.
Otherwise I consider it fair in the circumstances that the insurer settles the claim by
paying the complainant $80,000 representing approximately two thirds of the
complainant’s quote. In determining this is a fair figure I have taken into account that
most likely some of the damage was pre-existing due to the long-term nature of the
leak from the neighbour’s property and some damage likely to be seasonal.
Determination | Case number: 673049 Page 8 of 13
3 Supporting information
3.1 Relevant Law
What is the proximate cause of a loss is a question of fact depending upon the
circumstances of each case.
Courts, in considering proximate cause, have clearly stated that it is not the first, or
the last or the sole cause of a loss which is proximate: it is the effective or dominant
or operative cause.
If there are several causes of a loss operating contemporaneously, each must be
examined for the qualities of reality, predominance and efficiency as the active,
efficient cause that sets a relevant chain of events in action. If one cause would have
caused the harm in any case, and the other would not have done so in the absence of
the first, the first is the proximate cause.
3.2 Relevant extracts from expert reports
Expert and date Key points
FF engineer AA
3 October 2018
Determine the cause of damage
The damage that has occurred to the Insured's dwelling is
consistent with differential footing movement.
The differential footing movement that has occurred due to
Inherent volatility of the naturally occurring reactive clay founding
soils (to change in moisture condition)
Historic sewer leakage originating within the western side
neighbouring property, which was able to occur alongside the
Insured's dwelling over a prolonged time before it was eventually
rectified (recently).
Existing site landscape and drainage conditions allowing surface
rainwater runoff to be directed toward and pot entially migrate into
the sub floor area of the dwelling along the western side of the
property, during any signific ant rainfall event experienced in the
region over the lif e of the dwelling.
Water leakage via the hydronic heating plant located to the
external western side of the dwelling, which has potentially
allowed water to permeate into the sub floor area of the dwelling
locally.
Differential footing movement and consequ ential
damage/distress that has occurred to the fabric of the dwelling is
believed to have developed over a period of many years, i.e. over
a period of at least 2 - 3 years
- If the escapes of liquid identified above are in fact insurable
events, differential footing movement and consequential building
superstructure damage/distress would not typically occur within
72 hours of the events (i.e. within 72 hours of the first discharges
Determination | Case number: 673049 Page 9 of 13
Expert and date Key points
of water associated with the ongoing and/or int ermittent water
leakage events) . Differential building movement resulting from
such events would typically occur after weeks or months (not
hours/days) of the result ant wat er accumulating alongside the
footings i.e. subject to various factions including and not limited
to volume of wat er,
FF’s engineer IM
17 June 2019 The site soil is reactive; however, we do not know how reactive.
Three hand - augured boreholes were excavated to just 1500mm,
as is required by AS2870 and recorded clay, however we do not
know what happens below this dep th. Our experience indicates
the clays found in the region are moderately to highly reactive.
There is also some variation bet ween the mat erial found centrally
and towards the front of the site compared to that at the rear. We
would expect the rear of t he site to respond to moisture change
more significantly than elsewhere.
Reactive soils change volume with a change in moisture content.
Therefore, as a reactive or ‘clay’ soil becomes moister it expands
and heaves lifting the footing supported by it.
Alternatively, if a clay soil dries, it shrinks and allows a settlement
of the footings supported by it.
Plumbing testing undert aken for the insured in November 2017
concluded the sewer was sound (being suspended above ground
and therefore visible beneath the floor), however it does not
appear they have tested the pipework between the building and
the street.
The dwelling is constructed well elevated from the street at the
front, and therefore with adequate fall away from the dwelling, it
is possible th at this pipe work is leaking, It is also possible that
this apparent upward movement is due solely to removal of a
relatively small, albeit mature and developed street tree.
The plumbing report also reports sub - floor moisture, possibly due
to the tanks on the western side of the dwelling preventing flow of
any surface moisture in the vicinity . R ecommend these tanks be
emptied and lifted or dec ommissioned from the area. At the time
of writing this report the owner had not yet undertaken this work,
however indicated he would do so.
The owner’s leak det ection report also reported a gutter pop
being not sealed adjacent to a rain - head. We assume this is
adjacent to the powder room and are unsure if this has been
addressed. We do not believe this is a source of render cracking
however other damage may arise if this has not yet been
addressed.
CCTV of the stormwater pipework indicated poor grade and that
it was holding water, had a build - up of leaf litter and tree root
ingress. It is not clear where this root ingress was found,
however the owner indicated it was near the garage, we assume
Determination | Case number: 673049 Page 10 of 13
Expert and date Key points
adjacent the downpipe at the garage’s nort h western corner.
it has been identified that an exterior WC situated immediately
adjacent to the powder room was removed between 2 2 May
2017 and 1 September 2017. It has also been suggested that
this was serviced by defective pipework. It is thought that this
pipe was leaking for some years and its removal, or absence of a
leak has caused a downward movement in that vicinity which has
contribut ed to the cracking damage experienced.
It is unclear how often this outside toilet was used or indeed how
much of the sewer was defective. Test site 2 hand - augured by
Saunders Consulting Group in (winter) July 2007 appears to
have been in pr oximity to the powder room, and recorded ‘moist
and stiff’ conditions, which was like Test site 1, towards the front
and remote from the neighbour’s WC.
Given the insured sites sewer entry point is situated adjacent to
the western boundary, it is plausibl e that the neighbour’s sewer is
also aligned on the western side, it would therefore follow that the
decommissioned WC pipe work extended across the rear of
neighbouring building away from the insured dwelling. This
together with being at the top of the d rain, could possibly diminish
the wetting effect on the insured’s side of the boundary.
We certainly would not expect leakage from this pipe work to
extend to the other side of the newer (insured) dwelling, nor back
towards the garage. There is a masonry chimney on the
neighbouring (western) property near the removed exterior WC
and insured laundry. The footing of which, is very close to the
insured boundary, supporting the need for the exterior WC to be
plumbed away from the insured dwelling rather than down the
side, and therefore adjacent to the insured dwelling. There was
also no discernible damage to this chimney, which also supports
the determination that this leakage only affected the immediate
vicinity.
Another likely factor cont ributing to mov ement on the insured site
is the effect of tree removal at the rear prior to construction.
Large native trees can result in long - term drying of the foundation
soils. Their removal results in wetting up of the previously
desiccated soils, and a return to wetter moisture regime.
This may explain the footing designers, (assumed) original
design to include screw - in - piles across the entire rear boundary.
It is also possible that the screw in piles were deemed necessary
to prevent adjacent services wit hin Edw ard Street, undermining
the garage footing,
This movement may have increased to noticeable levels
following the removal of the tree on the neighbouring site to the
east and construction of a garage on that site. Despite this
occurring in 2013/2014, the re bounding effect is very slow and
normally takes several wint ers to manifest.
It could additionally be argued that the absence of leakage
Determination | Case number: 673049 Page 11 of 13
Expert and date Key points
caused through removal of a WC serviced by a problematic
sewer had contributed to some movement in the immediate
vicin ity only. We would expect this to extend no further than the
Powder room, Laundry and Rumpus room. Given the relatively
minor damage on the periphery of this area, this damage is likely
to be contained to that at the junction bet ween the Powder room
and Laundry only.
In the absenc e of any pipe work fractures in - front of the dwelling,
we would conclude that this upward trend was the result of the
street tree removal and a wetter regime following landscaping.
This is only affecting the minor cosmetic dis ruption in the ensuite.
The binding kitchen cupboard door is a function of differing
footing movement between the stiffer perimeter footings and the
intermediate pad footings supporting the central concrete
stumps.
The hairline cracking to the feat ure wa ll is not currently
structurally significant and could be a result of minor footing
movement or concrete shrinkage.
The moisture differential due to moisture under the perimeter in
this area needs to be addressed at the earliest convenience. We
have not assessed the possibility of ceiling/ flooring sag in this
area, however con do so if necessary.
The exterior render cracking and disruption adjacent to the
laundry and powder room is in our opinion primarily resultant on
the nearby change in environment, u pon removal of the adjacent
WC and sewer pipework. Cosmetic repairs to this masonry could
be considered, however we would not recommend this until the
drainage issues due to the positioning of the tanks be addressed,
and any affected soils completely dry.
Render cracking and compression of the window frames on the
dwelling’ eastern side between the alfresco and the garage has
been caused by the elevation of the garage structure. This has
been a gradual process due to the removal of trees at the rear of
the insured and neighbouring eastern site and the capping of that
area with a continuous concrete slab.
Complainant’s engineer CM
25 September 2019 Based on the background history and information presented in
both the abovementioned reports, reviewed and considered by
this office, it is my opinion that the AA Engineering Report
provides the best summaris ed findings and most accurate
assessment of the likely cause of damage observed to dwelling.
The IM engineers report placed emphasis on the presenc e and
past removal of trees (many years ago) as a significant
contribution to the damage &/or distress observed to dwelling.
Trees (both presence of, and removal of) can and do definitely
cause abnormal moisture conditions in reactive clay soils.
Determination | Case number: 673049 Page 12 of 13
Expert and date Key points
However, in this case, given the loc ation of damage &/or distress
to dwelling, and given the location of past tree removal, it is my
opinion that others external factors, in particular leaking
neighbouring plumbing, have likely contributed more significantly
to the observed damage &/or distress to dwelling.
Complainant’s builder MM
21 August 2018 The home has been affected by a broken pipe event which has
since been repaired.
The damage evident is typical of a Broken Pipe event.
There is a row of Ornamental Pear trees planted along the East
Side boundary that will likely cause future damage to the home.
These trees should be removed or isolated to limit the future
impact .
There is an open garden bed adjacent to the East side wall of the
residence and this should be sealed to prevent water affecting
the footing system in line with CSIRO BTF18 Perimeter
Protection recommendations.
Complainant’s plumber AM
27 November 2017 Visual inspection of suspended sewer drain proved ok and in
sound condition. CCTV inspection of the stormwater drain
showed areas that had poor grade and holding water, build up of
leaf litter and tree root ingress.
Also, one small puncture, although it is not believed that this is
the issue contributing to cracked render and dampness sub floor.
It is believed that no surface drainage and wat er tanks stopping
the flow of stormwater is the fault of sub floor dampness. A gutter
pop not sealed a t a rain head and separated silicon sealant is the
fault of water ingress between brickwork and render, causing the
render to crack.
Raise tanks off ground onto a stand. Surface drainage pits. Seal
flashings and pop.
Complainant’s builder DL
9 April 2020 The cause of the damage to property was from the west side
neighbouring property which has since rectified the problem.
Over a prolonged period of time water was escaping damaged
earthenware piping from an old out house building leaking water
into the abov e - mentioned property, and now the ground has had
time to dry out it has sunken under the weight of the dwelling as
the ground shrinks back and settles
Determination | Case number: 673049 Page 13 of 13